1. Introduction
The DIGITEN G2" Water Flow Hall Sensor Switch Meter (Model FL-1608) is designed for monitoring liquid flow rates. It is primarily composed of a plastic valve body, a water flow rotor assembly, and a Hall sensor. This device is typically installed at the water inlet end of a water heater or similar system to measure the water flow.
As water passes through the rotor assembly, the magnetic rotor rotates, and its speed changes proportionally with the flow rate. The integrated Hall sensor then outputs a corresponding pulse signal, which can be fed back to a controller for flow rate judgment and adjustment.
Key Features:
- Lightweight, compact, and easy to install.
- Impeller inlaid with stainless steel beads for wear resistance.
- Sealing ring designed with an up and down force structure to prevent leaks.
- Hall element imported from Germany, encapsulated with potting glue for water resistance and durability.
- Constructed with raw materials meeting ROSH testing standards.
- Waterproof, heat-resistant, pressure-resistant, and cold-resistant design.
2. Specifications
| Parameter | Value |
|---|---|
| Model Number | FL-1608 |
| Inlet / Outlet Size | BSP G2" |
| Rate Work Voltage | DC 5V ~ 24V |
| Max Work Current | 15mA (DC 5V) |
| Operating Voltage Range | DC 5V ~ 18V |
| Load Capacity | ≤10mA (DC 5V) |
| Operating Temperature Range | ≤80°C |
| Operating Humidity Range | 35% ~ 90%RH (No Frosting) |
| Allowable Pressure | Below 1.75Mpa |
| Storage Temperature | -25°C ~ +80°C |
| Storage Humidity | 25% ~ 95%RH |
| Output Pulse High Level | >DC 4.5 V (Input Voltage DC 5 V) |
| Output Pulse Low Level | |
| Accuracy (Flow Rate - Pulse Output) | 10 ~ 200L/min ±5% |
| Output Pulse Duty Cycle | 50 ±10% |
| Output Rise Time | 0.04µS |
| Output Fall Time | 0.18µS |
| Flow-Pulse Characteristics | Horizontal Test Pulse Frequency (Hz) = [0.2 * Q] ±5% (Q is flow rate L/min) |
| Sensor Type | Hall effect |
| Cable Length | 480mm |
| Max Size (Approx.) | 92mm x 68mm |
3. Package Contents
- G2" Flowmeter x 1
4. Setup and Installation
4.1 Installation Guidelines:
- The sensor can be installed either horizontally or vertically.
- Ensure the flow direction arrow on the sensor body aligns with the actual water flow.
4.2 Wiring Instructions:
Connect the sensor to your control system using the following wiring scheme:
- Red Wire (IN): Connect to VCC (+) (JST PIN 1#)
- Yellow Wire (OUT): Connect to Signal Output (JST PIN 2#)
- Black Wire (GND): Connect to Ground (JST PIN 3#)
5. Operation
Once installed and wired correctly, the sensor will begin to output a pulse signal proportional to the water flow rate. This pulse signal is a square wave, with a duty cycle typically between 40% and 60%.
The frequency of the output pulse can be used by a connected controller to calculate the precise flow rate (Q in L/min) using the formula: Frequency (Hz) = [0.2 * Q] ±5%.
6. Maintenance and Precautions
- Avoid severe impact and chemical erosion to the sensor.
- Do not throw or subject the sensor to collision.
- Ensure the temperature of the medium flowing through the sensor does not exceed 120°C.
- Regularly inspect the sensor for any signs of wear or damage, especially the sealing ring, to prevent leaks.
- Keep the flow path clear of debris to ensure accurate readings and proper operation of the impeller.
7. Troubleshooting
- No Output/Incorrect Readings:
- Verify all wiring connections are secure and correct (Red to VCC, Yellow to Signal, Black to GND).
- Check for any blockages or debris within the sensor's flow path that might impede the impeller's rotation.
- Ensure the operating voltage is within the specified DC 5V-18V range.
- Confirm the water flow direction matches the arrow on the sensor body.
- Leaking:
- Check the tightness of the threaded connections.
- Inspect the sealing ring for damage or improper seating.
8. User Tips
- Always double-check the wiring before applying power to prevent damage to the sensor or control unit.
- For precise flow measurement, ensure the sensor is installed in a straight section of pipe, away from bends or valves that could cause turbulence.
- Consider using thread sealant tape on the G2" threads to ensure a watertight connection.
9. Warranty and Support
For technical assistance, warranty claims, or further product information, please contact the DIGITEN Official Store or your original point of purchase. Please refer to the official user manual (PDF) for additional details and specific warranty terms.
A detailed user manual in PDF format is available for download. You can find it by searching for 'FL-1608 Water Flow Sensor Manual' on the manufacturer's website or by referencing the product page where you purchased the item.