DIGITEN FL-808

Contents

G1" Water Flow Hall Effect Sensor Switch Flow Meter FL-808 User Manual

Model: FL-808

1. Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of the DIGITEN G1" Water Flow Hall Effect Sensor Switch, Model FL-808. This sensor is designed to measure water flow rate by converting it into a pulse signal, suitable for various applications requiring flow monitoring.

Front view of the DIGITEN FL-808 G1 inch water flow sensor
Figure 1: Front view of the FL-808 Water Flow Sensor

2. Features

  • Compact and lightweight design for easy installation.
  • Impeller inlaid with stainless steel beads for wear resistance.
  • Reliable sealing ring structure to prevent leakage.
  • Hall element imported from Germany, encapsulated with potting glue for water ingress protection and durability.
  • Constructed with raw materials meeting ROSH testing standards.
  • Waterproof, heat resistance, pressure resistance, and cold resistance.
  • Outputs a square wave pulse signal proportional to flow rate.

3. Specifications

ParameterValue
Inlet / Outlet SizeBSP G1"
Rate Work VoltageDC 4.5V-12V
Max Work Current15mA (DC 5V)
Operating VoltageDC 4.5V-12V
Load Capacity≤10mA (DC 5V)
Operating Temperature Range≤80℃
Operating Humidity Range35%~90%RH (No Frosting)
Allowable PressureBelow 1.75Mpa
Storage Temperature-25~+80℃
Storage Humidity25%~95%RH
Output Pulse High Level>DC 4.5 V (Input Voltage DC 5 V)
Output Pulse Low Level<DC 0.5 V (Input Voltage DC 5 V)
Accuracy (Flow Rate - Pulse Output)1~60L/min Within ±5%
Output Pulse Duty Cycle50±10%
Output Rise Time0.04μS
Output Fall Time0.18μS
Characteristics of Flow-PulseHorizontal Test Pulse Frequency (Hz)=[4.8* Q]±3% (Q is flow rate L/min)
Cable length15cm
Diagram showing output square wave and physical dimensions of the FL-808 sensor
Figure 2: Output Waveform and Dimensions

4. Installation

4.1 Physical Installation

  • The sensor can be installed either horizontally or vertically.
  • Ensure the flow direction matches the arrow indicated on the sensor body.
  • Use appropriate G1" fittings for connection to your water system.
Angled view of the FL-808 sensor showing the wiring connection point
Figure 3: Sensor with wiring

4.2 Wiring Instructions

The sensor features a 3-wire connection. Connect as follows:

Top view of the FL-808 sensor showing the product label with wiring details
Figure 4: Product label with wiring information
Wire ColorFunctionJST Pin
RedVCC (+)1#
BlackGND3#
YellowSignal Output2#
Close-up view of the 3-pin JST connector for the water flow sensor
Figure 5: JST Connector Detail

5. Operation

The water flow sensor operates by monitoring the rotation of an internal magnetic rotor. As water passes through the sensor, the rotor spins, and the Hall sensor detects these rotations, generating a corresponding pulse signal. The frequency of this pulse signal is directly proportional to the water flow rate.

This pulse signal can then be fed to a microcontroller or other control system to measure and adjust the water flow as needed. The output waveform is a square wave with a duty cycle of 40%~60%.

Diagram showing the square wave output of the sensor
Figure 6: Output Square Wave

6. Maintenance and Cautions

  • Severe impact and chemical erosion are strictly prohibited.
  • Avoid throwing or collision with the sensor.
  • The temperature of the medium (water) should not exceed 120°C.
  • Regularly check connections for tightness and ensure no leaks are present.

7. Troubleshooting

  • No Signal Output: Check wiring connections (Red to VCC, Black to GND, Yellow to Signal). Ensure power supply is within the specified operating voltage range (DC 4.5V-12V). Verify water flow through the sensor.
  • Inaccurate Readings: Ensure the sensor is installed correctly with the flow direction arrow aligned. Check for any blockages or debris inside the sensor that might impede the impeller. Verify the calculation formula for flow rate (Hz = [4.8 * Q] ±3%).
  • Leakage: Re-check all plumbing connections and ensure they are properly sealed. The sensor's internal sealing ring is designed to prevent leaks, but external connections must be secure.

8. User Tips

  • For optimal performance and longevity, avoid installing the sensor in locations subject to extreme vibrations or direct impact.
  • Consider using a filter upstream of the sensor to prevent debris from entering and affecting the impeller's rotation.
  • When integrating with microcontrollers, ensure proper signal conditioning if necessary, especially for long cable runs.

9. Package Contents

  • 1 x FL-808 Water Flow Hall Effect Sensor

10. Warranty and Support

For any technical assistance or warranty inquiries, please contact the seller or manufacturer directly. Please refer to the official product page or included documentation for specific warranty terms and conditions.

An additional user manual in PDF format is available for download: View User Manual (PDF)

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.