DATOUBOSS DT-3U-48100

Contents

DATOUBOSS 51.2V 100Ah LiFePO4 Lithium Battery User Manual

Model: DT-3U-48100

1. Introduction

This manual describes in detail the requirements and procedures for safe installation and operation of the DATOUBOSS 51.2V 100Ah LiFePO4 Lithium Battery. This battery, model DT-3U-48100, is a lithium iron phosphate battery designed with a standard 3U rack-mount form factor. It features A-grade cells, a rated energy of 5.12 kWh, and a maximum charge/discharge current of 100 A. The unit includes a built-in smart Battery Management System (BMS) and supports RS485, CAN, and RS232 communication interfaces, as well as Bluetooth and WiFi for app monitoring. Its modular design allows for flexible expansion, supporting up to 15 units connected in parallel to achieve a total capacity of 76.8 kWh. With a cycle life exceeding 15,000 cycles, it offers high safety and a long service life, making it suitable for various applications including home energy storage, off-grid backup power, RVs, and light electric vehicles.

Please read this manual carefully before installation, operation, and maintenance. Only qualified persons are permitted to install, operate, and maintain the system to prevent product damage or personal safety risks.

2. Safety Information

2.1 General Safety Precautions

DANGER:
  • Do not impact the battery with heavy objects.
  • Do not squeeze or pierce the battery pack.
  • Do not throw the battery pack into fire.
  • Do not connect the battery in series.
WARNING (Fire Risk):
  • Do not expose the battery pack to conditions over 80°C.
  • Do not place the battery near a heat source, such as a fireplace.
  • Do not expose the battery pack to direct sunlight or rain.
WARNING (Electric Shock Risk):
  • Do not allow non-qualified persons to disassemble the battery pack.
  • Do not touch the battery pack with wet hands.
  • Do not expose the battery pack to moisture or liquid environments.
NOTICE (Damage Risk):
  • Do not short-circuit or reverse connect the battery.
  • Do not use chargers or charging devices unapproved by the manufacturer to charge the battery.
  • Do not mix batteries from different manufacturers or different types or brands.
  • For safety, it is not recommended to use the battery near the ocean.

2.2 Safety Instructions

The battery has been designed and tested in accordance with international safety requirements (UL, IEC, UN38.3, etc.). However, due to various factors during its lifetime, DATOUBOSS cannot guarantee absolute safety. To prevent personal and property damage and ensure long-term operation, please read and follow the instructions carefully.

2.3 Safety Gear

When installing and handling the battery pack, it is required to wear the following safety gear:

  • Insulated gloves

    Insulated Gloves

  • Safety glasses

    Safety Glasses

  • Safety shoes

    Safety Shoes

2.4 Emergency Safety Measures

Water Invasion: Cut off the AC power supply of the system first, then disconnect all switches under the premise of ensuring safety.

Electrolyte or Gas Leakage: If the battery pack leaks electrolyte, avoid contact with the liquid or gas. If exposed, immediately perform the following actions:

  • Gas Inhalation: Evacuate people from the contaminated area and seek medical aid immediately.
  • Eye Contact: Flush eyes with clean, flowing water for 15 minutes, then seek medical aid immediately.
  • Skin Contact: Thoroughly rinse the exposed area with soap and water to ensure no chemicals remain, then seek medical aid immediately.
  • Ingestion: Induce vomiting and seek medical help immediately.
WARNING: In case of fire, use a carbon dioxide fire extinguisher rather than liquid to put out fires.

2.5 Other Tips

  • All products are strictly inspected before shipment. Contact support for replacement if you notice any defects such as swelling.
  • Do not disassemble batteries and components. Unauthorized disassembly or repair voids warranty and manufacturer responsibility for damage.
  • Ensure the battery is safely grounded before use for safe and normal system operation.
  • Verify that the electrical parameters of all connected devices are mutually compatible.
  • Consider environmental factors carefully. The environment and storage methods impact the service life and reliability of this product.

3. Product Overview

3.1 General Schematic

The DATOUBOSS battery functions as a storage unit in photovoltaic systems. Below is a general schematic of an AC-coupled system:

General schematic of an AC-coupled system showing PV panels, combiner box, PV inverter, battery inverter, battery, meter, grid, general load, and backup load.

Figure 1: General Schematic of an AC-Coupled System

3.2 Features

  • High Safety: Made from LiFePO4 chemistry, complying with international safety and transport standards.
  • Modular and Flexible: Supports connecting up to 15 batteries in parallel to expand system energy.
  • Built-in Pre-charge Circuit: Avoids rush current when connecting with different inverters/chargers.
  • Automatic Dynamic Addressing: For multiple batteries connected together.
  • High DOD: Supports a maximum of 96% Depth of Discharge (DOD) under off-grid and backup applications.
  • Smart BMS: Provides warning and protection functions including over-discharging, over-charging, over-current, short-circuit, and high/low temperature protection.
  • Automatic Balancing: LiFePO4 is equipped with an automatic balancing function for long cycle life. New batteries require approximately 10 charge-discharge cycles to reach maximum capacity.
  • Compact Size and Light Weight: For easy installation and maintenance.
  • Communication Ports: CAN/RS485 port for external communication.

3.3 Specifications

3.3.1 Dimensions

Battery dimension diagram showing length 521mm/20in, width 483mm/19in, height 110mm/4.3in.

Figure 2: Battery Dimensions

Table 1: Physical Dimensions and Weight
ItemValue
Dimension22.09*19.02*5.24in / 56.1*48.3*13.3cm
Weight94.8lb / 43kg

3.3.2 Electrical Parameters

Table 2: Electrical Parameters (DT-3U-48100)
ItemValue
Rated voltage51.2V
Max. voltage range40.5~54.75V
Charge voltage58.4V
Low voltage cut-off40.0V
Nominal energy5.12kWh
Usable energy5.12kWh
Nominal capacity100Ah
Standard charge current≤50A
Max. charge current100A
Max. discharge current100A (initial temp. ≤35°C)
Communication portRS485/CAN/RS232
Max. parallel number15pcs
Operating temperature (Charge)0~55°C
Operating temperature (Discharge)-20~55°C
Storage temperature (-20~25°C)Less than 1 year
Storage temperature (20~40°C)Less than 3 months
Environment at shipment state60±25% R.H.

3.3.3 BMS Parameters

Table 3: BMS Parameters (Charge)
Charge ParameterSpecDelayRecovery
Cell Voltage Protection3600mV3000mS3400mV
Module Voltage Protection58.4V3000mS54.4V
Charge Over Current 1105A2000mS
Charge Over Current 2120A2000mS
Temperature Protection<32°F/0°C or >149°F/65°C
Table 4: BMS Parameters (Discharge)
Discharge ParameterSpecDelayRecovery
Cell Voltage Protection2500mV3000mS3000mV
Module Voltage Protection40.0V3000mS48.0V
Discharge Over Current 1105A2000mS
Discharge Over Current 2120A2000mS
Short Circuit1200A400uS
Temperature Protection<-4°F/-20°C or >149°F/65°C
Table 5: BMS Communication and Power Consumption
BMS ParameterParameterCondition
PCB Temperature Protection>221°F/105°C
Cell Balance60mV charging equalization
Temperature Accuracy±3°C
Cell Voltage Accuracy±10mVFor Cells
Current Accuracy±2%
SOC5%
Power Consumption (Off Mode)≤20uAStorage/Transport
Power Consumption (Sleep Mode)≤200uASleeping
Power Consumption (Operating Mode)≤60mACharging/Discharging
Communication PortsRS485, CAN, RS232
Bluetooth & WiFi Signal Distance≥49 feet/15m
NOTICE: The optimum operating temperature range is from 15°C to 30°C. Frequent exposure to harsh temperatures may worsen the performance of the battery pack and its cycle life.

3.3.4 Panel Interface

Battery panel interface diagram with labeled components: Handles, Grounding, Negative terminal, Positive terminal, 125A breaker, Power switch, ON/OFF indicator, Reset, ADS, RUN, ALM, Dry contact, SOC, RS485-1, CAN, RS232, RS485 IN/OUT, Mounting ear.

Figure 3: Battery Panel Interface

Table 6: Panel Interface Description
NO.ItemUsage Description
AHandlesFor handling, installation and disassembly of battery
BGroundingUsed to connect battery with ground
CNegative terminalUsed to connect the inverter/charger
DPositive terminalUsed to connect the inverter/charger
E125A breakerOver-current protection
FPower switchUsed to Power on/off battery
GON/OFF indicatorIndicates whether the battery is turned on or off
HResetUsed to reset the BMS
IADSUsed to set the address of the battery in the battery pack
JRUNUsed to show battery is in running status when lighting or flashing
KALMUsed to show battery Alarm/Protection status
LDry contact2 channels output signal, 1 channel input signal (Pin1 on the left)
MSOCUsed to show battery real-time SOC
NRS485-1Connect to host computer/inverter
OCANConnect to inverter
PRS232Connect to host computer/inverter
QRS485 IN / RS485 OUTFor communication between batteries
RMounting earUsed to fix with rack

3.3.5 Communication Interface Pin Diagram

Communication interface pin diagram for RS485-1, CAN, RS232, ADD_IN, ADD_OUT, and RS485-2 ports.

Figure 4: Communication Interface Pin Diagram

Table 7: Communication Port Pin Descriptions
Communication PortFunctional DescriptionPINDescription
RS485-1Connect to host computer/inverter1,8RS485-B1
2,7RS485-A1
4NC
5NC
CANConnect to host computer/inverter4CANH1
5CANL1
3,6GND
RS232Connect to host computer1,2,6NC
3TX
4RX
5GND
RS485-2*2Parallel communication*21,8RS485-B2
2,7RS485-A2
4,5NC
3N(L)/OUT(R)
6GND

3.3.6 Communication Protocols/Devices Supported by Each Port

Table 8: Supported Communication Protocols and Devices
PortUsageSupported Protocols/Devices
RS485-1Connect to the inverter or upper computerPYLON-LV RS485 V3.5 2019/08/07 (9600)
Growatt BMS-V1.09(1)-20201022
VOLTRONIC-485-V1.0.3-200325
LXP-485-V1.0.0-210625
Deye-485 Modbus Protocol(4)-deye -V1.30-20160801
SRNE WOW PACE BMS Modbus_Protocol for RS485 V1.3(2020-11-24)
CANConnect to the inverterPylon-CAN-V1.2-180408-lowVoltage
Growatt BMS CAN-Bus-protocol-low-voltage-V1.04
Victron-CAN-V1.00-210107
Luxpowertek Battery CAN Protocol-V1.0-20200211
SMA-CAN-V1.0.0-210630-FSS-ConnectingBat-TIen--20W
Sofar-CAN-V1.00-211117-Rev6
PV1800F-CAN communication Protocol1.04.04
RS232Connect to the upper computerJBD-UP
Solar Assistant
Overkill

3.3.7 LED Indicator Light Description

Table 9: LED Indicator Light Description
State of SystemEventMOS (LED9)Run (LED8)Alarm (LED7)SOC (LED6-1)Description
Power offSleepOFFOFFOFFOFF OFF OFF OFF OFF OFFAll LEDs turn off
Static stateNormalOFFFlash1OFFRefer to table(4-11-2)
AlarmOFFONFlash3The over voltage alarm does not flash
ChargingOV protectONONONON ON ON ON ON ON
Temperature, Over-current, fail-safeONOFFONOFF OFF OFF OFF OFF OFF
NormalOFFFlash 3OFFRefer to table(4-11-2)
DischargingUV protectONFlash2OFFOFF OFF OFF OFF OFF OFF
Over-current, short circuit, temperature, fail-safeONOFFONOFF OFF OFF OFF OFF OFF
AlarmOFFFlash 3Flash 3

3.3.8 LED Flash Description

Table 10: LED Flash Description
Flash ModeON DurationOFF Duration
Flash10.25S3.75S
Flash20.5S0.5S
Flash30.5S1.5S

3.3.9 Protection Mechanisms

Table 11: Battery Protection Mechanisms
ItemDescriptionRemark
Charge End Cell/PACK high-voltageBMS stops charging if any cell or PACK voltage reaches protection value. Auto-released when both Pack and cell voltage return to release range or efficient discharge current is present.
Discharge End Cell/PACK low-voltageBMS stops discharging if any cell or PACK voltage is under protection value. Auto-released when all cell voltages return to release range or efficient charge current is present.Automatically recovers. Charge timely to avoid over-discharge into Low-power mode.
High temperatureBMS halts charging, discharging, or both if any cell, environment, or MOSFET temperature falls outside acceptable range.Automatic recovery
Low temperatureBMS stops charging or discharging or both if any cell/environment/MOS temperature is under range.Automatic recovery
Charge over-currentBMS stops charging when current is higher than protection value. Releases when system delay time is met.Automatically recovers. If locked after three consecutive times, manual intervention is required.
Discharge over-current/OverloadBMS stops discharging when current is higher than protection value. Releases when system delay time is met.Automatically recovers. If locked after three consecutive times, manual intervention is required.
Short-circuit/ReversedShort-circuit and Reversed polarity protection occurred.Charge to release Manual reset
Temperature, Voltage, Current sensor failureEntering failure mode requires manual intervention; no charging and discharging.Manual intervention
Dormancy modeAfter reaching a certain condition, it enters dormancy mode.Recoverable

4. Installation

4.1 Preparation

4.1.1 Safety Compliance

The system installation must be performed by qualified person(s). During the entire installation process, strictly follow local safety regulations and related operating procedures.

4.1.2 Environment Requirements

Table 12: Environmental Requirements
CategoryDescription
Working temperature-20°C~55°C (maximum operating range)
15°C~30°C (optimal temperature)
Relative humidity5%~90%, No condensation
Altitude<3000m
Safety requirement
  • Do not expose the battery to direct sunlight, rain and snow.
  • Do not place the battery within children/pet touchable area.
  • Do not place the battery near heat source and flammable material.
  • Do not place the battery in a closed place where ventilation is not available.
  • Do not drop, deform, impact, cut or spear with a sharp object.
  • Do not put heavy things on battery.
  • Do not disassemble the battery without Manufacturer's permission.
  • No conductive dust and water or other liquid to contact battery.
  • Follow emergency measures if there is water invasion or electrolyte/gas leakage.
  • Contact your supplier within 24 hours if any product failure happens.

4.1.3 Tools Required

Table 13: Required Tools
ToolPurpose
Screwdriver (slot, cross)General fastening
Multi-meterElectrical measurements
WrenchTightening fasteners
Clamp metersMeasuring current
Diagonal pliersCutting wires
Insulating tapeInsulating connections
Needle nose pliersHolding and bending wires
ThermometerObserving installation environment temperature
Clamping pliersSecuring components
Anti-static braceletPreventing electrostatic discharge
Wire stripperStripping wire insulation
Cable tiesOrganizing cables

4.2 Inspection

4.2.1 Unpack Precautions

  • Load and unload the equipment according to specified requirements to prevent sun and rain damage.
  • Check and confirm the goods (quantity, appearance, etc.) against the 'scope of delivery' before unpacking.
  • Handle with care during unpacking to protect the surface coating.
  • Record and contact the manufacturer if the inner packing is damaged after unpacking.
General materials included: Battery Pack, Manual, Communication cable.

Figure 5: General Materials Included

4.2.2 External Cable Kits (Optional, not included)

Cables connected to the inverter or junction box are external cable kits and are NOT included in the battery carton. Customers need to purchase them separately. Information is provided below:

Table 14: Optional External Cable Kits
TypeDetailQty.
Battery to Battery Communication CableStandard communication cable (200mm length)1PCS
Parallel CablesBattery to Battery positive cable (2AWG 2000mm RED)1PCS
Battery to Battery negative cable (2AWG 2000mm BLACK)1PCS
Grounding CableGrounding cable (0T1.5-5, 200mm length)1PCS
Cables (Inverter Connection)Battery to Inverter positive cable (2/0AWG 2000mm RED)1PCS
Battery to Inverter negative cable (2/0AWG 2000mm BLACK)1PCS
NOTICE: Keep unused cable pins NULL to avoid affecting closed loop communication.
NOTICE: A ground connection of the communication cable may be required for some inverters. Follow the rules from the inverter manufacturer.

4.3 Installation Procedures

CAUTION: Injuries may result if the product is lifted incorrectly or dropped while being transported or mounted. Wear suitable personal protective equipment for all work on the product.
CAUTION: Ensure no lines are laid in the wall which could be damaged when drilling holes.

4.3.1 Pre-installation Reminders

Before installation, re-check the following conditions and equipment:

  • Sufficient space for installation, and that the bracket or cabinet's load-bearing capacity meets weight requirements.
  • Power cable pair(s) meet the maximum current requirement for operation.
  • Overall layout of power supply equipment and batteries at the construction site is reasonable.
  • Installer is wearing an anti-static wristband.
  • Two people are present for installation work.
  • No potential risks at the installation site, such as flooding, sun exposure, corrosion, or salt spray.

4.3.2 Install the Battery into the Rack Slot

Carefully insert the battery into the designated rack slot.

Image showing a hand inserting the DATOUBOSS battery into a rack slot.

Figure 6: Inserting Battery into Rack Slot

NOTICE: For any other installations, avoid direct contact between the battery and the ground, and avoid high salinity or humidity to prevent rusting and corrosion.

4.3.3 Set the Inverter Communication Protocol

To set up communication with your inverter:

  1. Turn on the battery:
    • Open the 125A Circuit Breaker.
    • Press the POWER button.
  2. Use the mobile app to set the communication protocol:
    • Scan the QR code below to download the software.
    • Open the software and search for nearby devices (ensure Bluetooth is on and permissions are granted).
    • Modify the Inverter Protocol on the Parameter page (refer to APP-Quick Start for detailed information).
    Image showing the battery connected to an inverter and a mobile phone displaying the monitoring app. The image also lists various compatible inverter brands.

    Figure 7: Communication with Inverter and App Monitoring

4.3.4 Connect the Battery to the Inverter

  1. Battery-inverter power connection:
    Note: Turn off the POWER button and the breaker before connecting cables. Use the cables required by the inverter to connect the battery pack to the BAT input terminal of the inverter.
  2. Battery-inverter communication connection:
    Use a standard Ethernet cable to connect the battery's RS485-1 or CAN port to the BMS communication port of the inverter.
CAUTION: Confirm inverter AC input and PV input are disconnected before wiring connection, and the DC/signal switch of the inverter/charger is in the off status.
Image showing a hand connecting a blue communication cable to the battery's communication port and red/black power cables to the terminals. An inverter is visible in the background.

Figure 8: Connecting Battery to Inverter

4.3.5 Important Notes for Connection

NOTE: Choose a suitable disconnection breaker considering the inverter power/current, rated voltage, and tripping characteristics.
NOTICE: The maximum communication cable length is 15m between the inverter/charger and battery. The maximum power cable length is 10m between the inverter/charger and battery.
CAUTION: The maximum tolerance current for each power cable and terminal is 125A, with 100A suggested for continuous operation. Use the corresponding number of power cable pairs according to the field configuration and local connection requirements, standards, and directives.

5. Operation

5.1 Turning On/Off

To turn on the battery, ensure the 125A circuit breaker is open, then press the POWER button on the front panel. To turn off, press the POWER button again and close the 125A circuit breaker.

5.2 LED Indicators

The front panel features LED indicators (MOS, Run, Alarm, SOC) that provide real-time status information. Refer to Table 9: LED Indicator Light Description and Table 10: LED Flash Description in the Specifications section for detailed interpretation of these indicators during various states (Power off, Static state, Charging, Discharging).

5.3 Communication

The battery supports RS485, CAN, and RS232 ports for communication with inverters and upper computer systems. Bluetooth and WiFi capabilities allow for wireless monitoring via a mobile application. Ensure proper cable connections and protocol settings as detailed in the Installation section.

5.4 Parallel Operation

The DATOUBOSS battery supports connecting up to 15 units in parallel for increased capacity. When operating in parallel, the system can use either automatic addressing or manual DIP switch settings. If all DIP switches are dialed to OFF, the manual DIP address function is enabled. Otherwise, the default automatic addressing function is used. Refer to the 'ADS' section in the Product Overview for detailed DIP switch configurations.

NOTICE: For automatic coding method wiring, after wiring is completed, the main unit must be the last one to be turned on.

6. Maintenance

6.1 Storage Guidelines

  • Store the battery in a dry, clean, dark, and well-ventilated indoor environment.
  • The recommended long-term storage temperature range is 15°C to 30°C.
  • Ensure no harmful gases, flammable and explosive products, or corrosive chemical substances are present in the storage location.
  • Batteries should be stored and transported at approximately 50% State of Charge (SOC). Do not store over 80% SOC for extended periods.
  • If the battery is not used for a long time, it needs to be charged every 6 months.
  • Do not drop the battery, pile it up over 6 layers, and always keep it face up.

6.2 Optimal Operating Temperature

The optimal operating temperature range for the battery is 15°C to 30°C. Frequent exposure to extreme temperatures outside this range may negatively impact the battery's performance and shorten its cycle life.

7. Troubleshooting

Table 15: Troubleshooting Guide
ItemSolutionMeasure
Unable to start1. Switch on battery and press RESET for 6s to observe whether the battery can be started.
2. Charge the battery with a charger or inverter to provide 54-57.6V voltage and observe whether it can be started.
Unable to charge1. Check whether the cable connection between the battery and the inverter/charger is correct.
2. Check whether the inverter/charger setting is correct.
3. Check whether the battery is in charge protection mode; if yes, try to discharge the battery.
If the abnormal status is still present after these steps, please contact your supplier.
Unable to discharge1. Check whether the cable connection between the battery and the inverter/charger is correct.
2. Check whether the battery occurs short circuit, reverse connection, pre-charge failure during connection inverter etc.
3. Check whether the battery is in discharge protection mode; if yes, try to charge the battery.
High/Low temperature1. Stop the battery system for a while, and check whether the installation location temperature meets the requirement.
2. Avoid continuous full charging and discharging.
High currentCheck whether the configuration and parameters setting on the inverter/charger is correct.If there is any other situation(s) not listed in this table, turn off the faulty battery, and contact your supplier.
ALM ONTurn off all the batteries, and remove the fault battery from the system.
Communication fail1. Check whether the communication cable type is correct and is contacted well.
2. Check whether the DIP switch setting is correct.
3. Check whether the inverter protocol related setting is correct.
4. Check whether both battery and inverter are working properly.
NOTICE: Please restart after software is upgraded.

8. User Tips

  • Familiarize yourself with LiFePO4 battery characteristics and system integration before installation for a smoother setup.
  • Always double-check all connections and settings, especially communication protocols, to ensure proper functionality and avoid issues.

9. Disposal of Battery

Disposal of the battery must comply with local applicable regulations for electronic waste and used batteries. Please review your local battery recycling or management regulations or contact DATOUBOSS for more information.

10. Support

If you are experiencing technical problems and cannot find a solution in this manual, please contact DATOUBOSS for further assistance:

  • Email: Manager@xdatou.com
  • Website: www.xdatou.com
  • Phone/Wechat/Whatsapp/LINE: +8613783531376