1. Introduction
Thank you for choosing the PowMr LVM4K-SP / LVM6K-SP Split Phase All-In-One Solar Inverter. This device integrates a pure sine wave inverter, an MPPT solar charger, and a battery charger into a single unit, offering uninterruptible power support for your home or office. Designed for split-phase 110V/220V or 120V/240V applications, it provides stable output, efficient solar charging, and compatibility with lithium battery systems.
This manual provides essential information for the safe and efficient operation of your inverter. Please read it thoroughly before installation and use, and keep it for future reference.
2. Safety Instructions
WARNING! Please read all instructions and cautionary markings on the unit and in this manual before installation and operation.
- Installation must be performed by qualified personnel.
- Ensure all wiring is correctly polarized and securely connected to prevent damage to the inverter or connected devices.
- Do not disassemble the inverter. There are no user-serviceable parts inside. Refer servicing to qualified personnel.
- Keep the inverter away from flammable materials, moisture, and direct sunlight. Ensure adequate ventilation.
- Always disconnect all power sources (PV, battery, AC input) before performing any maintenance or wiring.
- This inverter is equipped with multiple intelligent protections including overload, overvoltage, undervoltage, overtemperature, short circuit, and battery reverse polarity protection. However, proper installation and usage are still critical.
3. Product Overview
The PowMr LVM4K-SP / LVM6K-SP inverter is a robust unit designed for off-grid solar applications. It features a user-friendly display and multiple connection ports for comprehensive system integration.
Key Features:
- High Efficiency: Converts solar energy into stable power efficiently.
- Split-phase Output: Supports 110V/220V or 120V/240V applications.
- Pure Sine Wave Inverter: Provides clean power suitable for sensitive electronics.
- Integrated MPPT Solar Charger: Maximizes power harvest from solar panels.
- Dual Communication Ports: RS232 for monitoring and RS485/BMS for lithium battery management.
- Multiple Charging Modes: User-selectable charging priorities.
- Comprehensive Protections: Overload, overvoltage, undervoltage, overtemperature, short circuit, and battery reverse polarity.
Product Appearance:

Figure 3.1: Front view of the PowMr Split Phase Solar Inverter, showing the display screen and branding.

Figure 3.2: Angled view of the PowMr Split Phase Solar Inverter, highlighting its compact design.
4. Setup and Installation
Proper installation is crucial for the safe and efficient operation of your inverter. It is highly recommended that installation be performed by a certified electrician or solar professional.
4.1 Unpacking and Inspection
- Carefully unpack the inverter and inspect it for any shipping damage. If any damage is found, contact your dealer immediately.
- Ensure all accessories are present.
4.2 Mounting the Inverter
- Choose a suitable mounting location: indoors, away from direct sunlight, heat sources, and moisture.
- Ensure the mounting surface is strong enough to support the inverter's weight.
- Allow sufficient clearance (at least 20 cm) around the inverter for proper ventilation and heat dissipation.
- Mount the inverter vertically on a wall using appropriate screws and anchors.
4.3 Wiring Connections
CAUTION: All wiring must comply with local and national electrical codes. Ensure all circuit breakers are OFF before making any connections.
While detailed wiring diagrams are not provided in the available documentation, general connection points for this type of inverter typically include:
- Battery Connection: Connect the battery bank to the DC input terminals. Ensure correct polarity (+ to + and - to -). Use appropriately sized cables and fuses.
- PV Array Connection: Connect the solar panel strings to the PV input terminals. Observe maximum input voltage (500Vdc) and current (18A) specifications. This inverter supports up to 9000W Max PV Input Power.
- AC Input (Grid/Generator): If connecting to a utility grid or generator, connect the AC input to the designated terminals.
- AC Output (Load): Connect your household or load circuits to the AC output terminals. This inverter provides split-phase 110V/220V or 120V/240V output.
- Grounding: Connect the inverter's chassis to a reliable earth ground.
4.4 Communication Connections
The inverter offers multiple communication interfaces for enhanced system integration:
- RS232 Port: For communication with host computers or monitoring devices. This enables remote parameter configuration and data retrieval. A WiFi module can be connected via this interface for mobile app monitoring.
- RS485/BMS Port: Integrated port for communication with lithium battery systems. This allows for battery data acquisition and charge/discharge management, ensuring optimal battery health and performance.

Figure 4.1: Diagram illustrating the RS232 and RS485/BMS communication ports and their functions.
5. Operating Instructions
5.1 Initial Power-Up
- After all connections are made and verified, switch on the battery breaker first.
- Then, switch on the PV array breaker.
- Finally, switch on the AC input breaker (if connected) and then the AC output breaker.
- The inverter display will light up, showing system status.
5.2 Display and Settings
The inverter features an intuitive display for monitoring system status and configuring settings. Refer to the on-screen menu for navigation and parameter adjustments. Common settings include output voltage, frequency, and charging parameters.
5.3 Charging Modes
The inverter offers three user-selectable charging modes to optimize solar utilization and charging efficiency:
- Solar First: Solar energy will charge the battery as the first priority. Utility power will charge the battery only when solar energy is not available.
- Solar and Utility: Both solar energy and utility power will charge the battery at the same time.
- Only Solar: Solar energy will be the only charger source, no matter if utility power is available or not.

Figure 5.1: Visual representation of the three available battery charging modes.
5.4 Real-Time Monitoring via APP
By connecting a WiFi module through the RS232 interface, the inverter can communicate with mobile devices for real-time data transmission. The app provides a device overview, operating status, real-time energy flow monitoring, and a summary of key power data.

Figure 5.2: Screenshot of the mobile application interface showing device overview, energy flow, and power data summary.
6. Maintenance
Regular maintenance ensures the longevity and optimal performance of your PowMr inverter.
- Cleaning: Periodically clean the inverter's exterior with a dry cloth. Ensure ventilation openings are free from dust and debris. Do not use liquid cleaners.
- Connections: Annually check all electrical connections for tightness and corrosion. Re-tighten if necessary.
- Ventilation: Ensure the area around the inverter remains clear and well-ventilated to prevent overheating.
- Battery Inspection: Follow the battery manufacturer's maintenance guidelines for your battery bank.
7. Troubleshooting
This section outlines common issues and potential solutions. For problems not listed here, please contact technical support.
| Problem | Possible Cause | Solution |
|---|---|---|
| Inverter not turning on | No battery power; Battery polarity reversed; Loose connections | Check battery voltage; Verify battery connections and polarity; Tighten all connections. |
| No AC output | Overload; Short circuit; Overtemperature; Output breaker tripped | Reduce load; Check for short circuits in wiring; Allow inverter to cool; Reset output breaker. |
| Battery not charging | PV input too low/high; PV polarity reversed; Charger settings incorrect; Battery fault | Check PV voltage/current; Verify PV polarity; Adjust charger settings; Inspect battery. |
| Error code on display | Specific system fault | Refer to the inverter's display for the specific error code and consult the full manual (if available) or contact support. |
7.1 Multiple Intelligent Protections
The inverter is equipped with advanced protection features to ensure system safety and longevity:
- Overload Protection: Shuts down output if connected load exceeds inverter capacity.
- Overvoltage Protection: Protects against excessively high input voltages.
- Undervoltage Protection: Protects against excessively low input voltages, especially from batteries.
- Overtemperature Protection: Shuts down if internal temperature exceeds safe limits.
- Short Circuit Protection: Protects against output short circuits.
- Battery Reverse Polarity Protection: Prevents damage from incorrect battery connection.

Figure 7.1: Icons representing the various intelligent protection features of the inverter.
8. Specifications
| Feature | Specification |
|---|---|
| Model Numbers | POW-LVM4K-SP / POW-LVM6K-SP |
| Rated Power | 4 kW / 6 kW (depending on model) |
| Input Voltage (DC) | 24VDC / 48VDC (depending on model) |
| Output Voltage (AC) | 110VAC/220VAC, 120/240Vac (Split Phase) |
| Output Frequency | 50Hz/60Hz (Auto sensing) |
| Output Type | Pure Sine Wave |
| Max PV Input Power | 9000W (4500W*2) |
| Max PV Input Voltage | 500Vdc |
| MPPT Tracking Range | 80~450Vdc |
| Maximum PV Input Current | 18A |
| Max Charge Current | 120A |
| Dimensions (L x W x H) | 403x352x118mm |
| Certification | CE |
| Communication Ports | RS232, RS485/BMS |

Figure 8.1: Overview of key specifications for the 6000W model.
9. User Tips
- Optimize Charging: Experiment with the three charging modes (Solar First, Solar and Utility, Only Solar) to find the best balance for your energy consumption patterns and solar availability.
- Monitor Performance: Utilize the mobile app monitoring feature to keep track of your system's performance, energy generation, and consumption. This helps in identifying potential issues early and optimizing usage.
- BMS Integration: If using lithium batteries, ensure proper integration with the inverter's RS485/BMS port for enhanced battery management and protection.
10. Warranty and Support
PowMr products are designed for reliability and performance. For warranty information, please refer to the warranty card included with your product or contact your point of purchase.
For technical support, troubleshooting assistance, or any questions regarding your PowMr LVM4K-SP / LVM6K-SP inverter, please contact PowMr customer service or your authorized dealer. Please have your model number and purchase details ready when contacting support.
Contact Information:
WhatsApp: +86 16633953613
Email: jinpin14@163.com