PowMr POW-HVM7K-48V

Contents

PowMr Hybrid Solar Inverter User Manual

Model: POW-HVM7K-48V

This manual provides detailed instructions for the safe and efficient use of your PowMr Hybrid Solar Inverter.

1. Introduction

This is a multi-function inverter/charger, combining functions of inverter, MPPT solar charger and battery charger to offer uninterruptible power support with portable size. Its comprehensive LCD display offers user-configurable and easy-accessible button operation such as battery charging current, AC/solar charger priority, and acceptable input voltage based on different applications.

1.1 Features

  • Pure sine wave inverter
  • Maximizes solar energy harvest through advanced MPPT technology.
  • Supports flexible charging from PV, utility, and generator sources.
  • Supports flexible power supply from PV, battery, utility, and generator.
  • Supports load operation without battery connection.
  • Provides a wide input voltage and frequency range for unstable grids.
  • Features a lightweight design for easy installation and maintenance.
  • Provides a large LCD display for clear system monitoring.
  • Supports both lithium and lead-acid batteries.
  • Supports remote monitoring via WiFi mobile APP.

1.2 Basic System Architecture

The following illustration shows basic application for this inverter/charger. It also includes following devices to have a complete running system: Generator or Utility, PV modules (option). Consult with your system integrator for other possible system architectures depending on your requirements. This inverter can power all kinds of appliances in home or office environment, including motor-type appliances such as tube light, fan, refrigerator and air conditioner.

Hybrid Power System Diagram
Figure 1: Basic Hybrid Power System Architecture. Shows connections between PV modules, inverter, battery, generator/utility, and various loads.

2. Safety Instructions

WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.

  1. Before using the unit, read all instructions and cautionary markings on the unit, the batteries and all appropriate sections of this manual.
  2. CAUTION - To reduce the risk of injury, only rechargeable batteries such as deep cycle lead-acid or lithium batteries can be charged. Other types of batteries may burst, causing personal injury and damage.
  3. Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
  4. To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
  5. CAUTION - Only qualified personnel can install this device with battery.
  6. NEVER charge a frozen battery.
  7. For optimum operation of this inverter/charger, please follow required spec to select appropriate cable size. It's very important to correctly operate this inverter/charger.
  8. Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts and could cause an explosion.
  9. Please strictly follow installation procedure when you want to disconnect AC or DC terminals. Please refer to INSTALLATION section of this manual for the details.
  10. GROUNDING INSTRUCTIONS - This inverter/charger should be connected to a permanent grounded wiring system. Be sure to comply with local requirements and regulation to install this inverter.
  11. NEVER cause AC output and DC input short circuited. Do NOT connect to the mains when DC input short circuits.
  12. Warning! Only qualified service persons are able to service this device. If errors still persist after following troubleshooting table, please send this inverter/charger back to local dealer or service center for maintenance.

3. Installation

3.1 Unpacking and Inspection

Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. You should have received the following items inside of package:

  • The unit x 1
  • User manual x 1 (Refer to this document)
  • Fixed bracket x 2
  • Screws x 4
  • WIFI module x 1

3.2 Mounting the Unit

Consider the following points before selecting where to install:

  • Do not mount the inverter on flammable construction materials.
  • Mount on a solid surface.
  • Install this inverter at eye level in order to allow the LCD display to be read at all times.
  • The ambient temperature should be between 0°C and 55°C to ensure optimal operation.
  • The recommended installation position is to be adhered to the wall.
  • Be sure to keep other objects and surfaces as shown in the figure below to ensure sufficient heat dissipation and adequate space for cable removal.
Mounting dimensions and clearances
Figure 2: Recommended mounting clearances (500mm top/bottom, 200mm sides).

SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.

Install the unit by screwing four screws. It's recommended to use M4 or M5 screws.

Inverter mounting diagram
Figure 3: Inverter mounting to a wall using screws.

3.3 Wiring

3.3.1 Preparation

Before connecting all wirings, please take off the bottom cover by removing four screws as shown below.

Removing bottom cover for wiring access
Figure 4: Inverter with bottom cover removed, showing internal wiring terminals.

3.3.2 Grounding

Before making any electrical connections, connect the inverter grounding terminal to a reliable protective earth (PE) conductor in accordance with local electrical regulations. The grounding terminal is located on the side panel of the inverter. Ensure that the grounding connection is completed before connecting photovoltaic modules, batteries, utility power, or loads.

WARNING: Failure to properly ground the inverter may result in electric shock, equipment damage, or improper system operation.

3.3.3 Battery Connection

For safety operation and regulation compliance, it's requested to install a separate DC over-current protector or disconnect device between battery and inverter. It may not be requested to have a disconnect device in some applications, however, it's still requested to have over-current protection installed. Please refer to the table for the recommended fuse or circuit breaker size.

Recommended Battery Cable and Circuit Breaker Size (7KW Model)
ModelWire SizeCable (mm²)Torque valueRecommended Circuit Breaker Size
7KW1*2AWG385 Nm200A

WARNING:

  • All wiring must be performed by qualified personnel.
  • It's very important for system safety and efficient operation to use appropriate cable for battery connection. To reduce risk of injury, please use the proper recommended cable and terminal size.

Please follow below steps to implement battery connection:

  1. Assemble battery ring terminal based on recommended battery cable and terminal size.
  2. The 7KW model supports a 48V battery system. The connection is shown in the diagram below.
Battery connection diagram for 7KW model
Figure 5: Battery connection diagram showing inverter, battery, and BMS connection.
  1. Insert the battery wires flatly into battery connectors of inverter and make sure the bolts are tightened with torque of 2 Nm in clockwise direction. Make sure polarity at both the battery and the inverter/charge is correctly connected and conductors are tightly screwed into the battery terminals.
Detailed battery terminal connection
Figure 6: Close-up view of battery terminal connections on the inverter.

WARNING: Shock Hazard - Installation must be performed with care due to high battery voltage in series.

CAUTION: Before making the final DC connection or closing DC breaker/disconnector, be sure positive (+) must be connected to positive (+) and negative (-) must be connected to negative (-).

3.3.4 AC Input/Output Connection

Before connecting to AC input power source, please install a separate AC breaker between inverter and AC input power source. This will ensure the inverter can be securely disconnected during maintenance and fully protected from over current of AC input. There are two terminal blocks with "IN" and "OUT" markings. Please do NOT mis-connect input and output connectors.

Recommended AC Cable and Circuit Breaker Size (7KW Model)
ModelGaugeTorque ValueRecommended Circuit Breaker Size
7KW10 AWG1.4~1.6 Nm63A

Please follow below steps to implement AC input/output connection:

  1. Before making AC input/output connection be sure to open DC protector or disconnector first.
  2. Remove insulation sleeve 10 mm for six conductors. And shorten phase L and N 3 mm.
  3. Insert AC input wires according to polarities indicated on terminal block and tighten the terminal screws. (L→LINE (brown or black); N→Neutral (blue))
AC input wiring diagram
Figure 7: AC input wiring connections to the inverter terminals.

WARNING: Be sure that AC power source is disconnected before attempting to hardwire it to the unit.

  1. Insert AC output wires according to polarities indicated on terminal block and tighten the terminal screws. (L→LINE (brown or black); N→Neutral (blue))
  2. Make sure the wires are securely connected.
AC output wiring diagram
Figure 8: AC output wiring connections to the inverter terminals.

CAUTION: Appliances such as air conditioner are required at least 2~3 minutes to restart because it's required to have enough time to balance refrigerant gas inside of circuits. If a power shortage occurs and recovers in a short time, it will cause damage to your connected appliances. To prevent this kind of damage, please check manufacturer of air conditioner if it's equipped with time-delay function before installation. Otherwise, this inverter/charger will trig overload fault and cut off output to protect your appliance but sometimes it still causes internal damage to the air conditioner.

3.3.5 PV Connection

Before connecting to PV modules, please install separately a DC circuit breaker between inverter and PV modules.

Recommended PV Cable and Circuit Breaker Size (7KW Model)
ModelGaugeTorque ValueRecommended Circuit Breaker Size
7KW12 AWG1.4~1.6 Nm32A

PV module selection:

Before selecting a suitable solar module, please refer to the following requirements:

  1. The open circuit voltage (Voc) of the solar module shall not exceed the maximum open circuit voltage of the inverter (<450VDC).
  2. The open circuit voltage (Voc) of the solar module should be higher than the minimum input voltage of the inverter PV (>150VDC).

The following is an example of a 380Wp solar panel configuration system. After considering the above two parameters, the recommended configuration is shown in the table below. For other specifications of components, the number of series and parallel connections is determined based on the open circuit voltage not exceeding 450V and the optimal working voltage of 360V.

Recommended PV Panel Configurations (Example for 7KW Model)
Panel PowerRated Voltage/Rated CurrentOpen-Circuit Voltage / Short-Circuit CurrentNumberTotal rated power / Total rated voltage
380Wp40.10V/9.49A48.82V/9.99A8 pieces in series and 2 pieces in parallel6080Wp/321V
500Wp40.08V/12.48A47.28V/12.18A9 pieces in series4500Wp/361V
550Wp40.05V/13.73A46.30V/13.50A9 pieces in series4950Wp/360V
590Wp39.09V/15.09A47.30V/15.85A9 pieces in series5310Wp/352V
615Wp39.96V/15.39A48.30V/16.10A9 pieces in series5535Wp/360V
660Wp38.10V/17.33A45.70V/18.42A9 pieces in series5940Wp/343V
710Wp40.69/17.4548.94V/18.45A9 pieces in series6390Wp/366V

Please follow below steps to implement PV modules connection:

  1. Remove insulation sleeve 10 mm for positive and negative conductors.
  2. Insert PV input wires according to polarities indicated on terminal block and tighten the terminal screws.
  3. Check correct polarity of wire from PV modules and PV input connectors. Then, connect positive pole (+) of connection wire to positive pole (+) of PV input connector. Connect negative pole (-) of connection wire to negative pole (-) of PV input connector.
PV module wiring diagram
Figure 9: PV module wiring connections to the inverter terminals.

3.4 Final Assembly

After connecting all wirings, please put the bottom cover back by screwing four screws.

4. Operation

4.1 Power ON/OFF

Once the unit has been properly installed and the batteries are connected, follow the power-on sequence below to start the inverter safely:

  1. Close the battery circuit breaker.
  2. Press the On/Off switch (located on the bottom of the case) to turn on the unit. Wait until the inverter starts up and enters normal operation (inverting).
  3. Close the PV, AC input and AC output circuit breaker.

To shut down the system, turn off the circuit breakers in the reverse order.

Power ON/OFF switch location
Figure 10: Location of the On/Off switch on the inverter.

4.2 Operation and Display Panel

The inverter features an LCD display and buttons for operation and monitoring.

LCD display and control panel
Figure 11: Inverter front panel with LCD display and control buttons.

4.2.1 Function Keys

Function Keys Description
Function KeyDescription
PRG/ESCTo enter setting mode or exit setting mode
UPTo go to next selection
DOWNTo go to previous selection
ENTERTo confirm the selection in setting mode

4.2.2 LED Indicator

LED Indicator Messages
LED IndicatorMessages
CHGGreen Solid OnBattery is fully charged.
FlashingBattery is charging.
AC/INVGreen Solid OnOutput is powered by utility in Line mode.
FlashingOutput is powered by battery or PV in battery.

Note: When a fault occurs, the device displays only the fault code and does not indicate a fault via an LED indicator. For detailed descriptions of fault codes, please refer to Section 5.

4.2.3 LCD Display Icons

The LCD display uses various icons to convey system status and information.

LCD display icons overview
Figure 12: Overview of LCD display icons and their arrangement.
LCD Display Icons and Descriptions
IconFunction description
PV input iconIndicates the PV input
AC input iconIndicates the AC input
8.8.8VCA%Indicate input voltage, input current, PV voltage, battery voltage and charger current. When "dxx" is displayed, it indicates that the system has entered the settings mode.
8.8Indicates the fault codes
8.8.8VHzAKWIndicate output voltage, output frequency, load in Watt.
Battery charging label iconBattery charging label
OVER LOADIndicates overload
Load indicator iconIndicates the load (with percentage segments)
PV panel connection iconIndicates unit connects to the PV panel.
Utility/MPPT charger circuit iconIndicates the utility /MPPT charger circuit is working.
DC/AC inverter circuit iconIndicates the DC/AC inverter circuit is working.

4.2.4 LCD Settings (d01-d25)

After pressing and holding the PRG button for 1 second, the unit will enter setting mode. Press "UP" or "DOWN" button to select setting programs. And then, press "ENTER" button to confirm the selection or ESC button to exit.

LCD Setting Parameters
NO.Setting PageSelection Information
d01Output Source PrioritySUB (default): Solar → Utility → Battery Mode: Solar power is prioritized for load supply. When PV power is insufficient, utility power supplements the loads. If utility power is unavailable, the loads are powered by PV and the battery. With utility available, the inverter enters battery discharge mode after the battery voltage reaches the d12 setting for 10 minutes, and returns to charging mode when the battery voltage drops 2 V below d12. Without utility power, the inverter supplies the loads from PV and the battery and stops AC output when the battery voltage falls below the d11 setting. When sufficient PV power is available, the battery charging voltage can reach the maximum value set by d15.
UFI: Utility First Mode: Utility power is prioritized to supply the loads, while PV power or utility power keeps the battery fully charged at all times. In the event of a utility power failure, the inverter immediately switches to inverter mode to supply the loads. When utility power is available, the inverter enters battery discharge mode after the battery voltage reaches the value set by parameter d15 for 10 minutes; when the battery voltage falls 2 V below the d15 setting, the inverter switches to battery charging mode.
ONI: Inverter Priority Mode: The inverter enters battery discharge mode after the battery voltage reaches the value set by parameter d15 and remains at this level for 10 minutes. When the battery voltage falls below the value set by parameter d11, the inverter switches to battery charging mode.
NBU: Battery-Free AC-Coupling Mode: In this mode, the inverter can operate without a battery. The load is powered by both the PV array and the utility grid. For example, if the PV array generates 1 kW while the load requires 2 kW, the remaining 1 kW is supplied by the utility grid. If the load decreases to 500 W, the utility grid will no longer supply power, and the load will be powered entirely by the PV array. Any excess PV power (500 W in this example) will not be exported to the utility grid, ensuring zero-export operation.
d02Utility Input Voltage RangeWID: Wide input voltage range: 90-270VAC
NOR (default): Normal input voltage range: 160-240VAC
d03AC Output Voltage220V (default), 230V, 240V: AC output voltage: adjustable 220/230/240V.
d04AC Output Frequency50Hz (default), 60Hz: AC output frequency: 50 Hz or 60 Hz.
d05SOC Charge/Discharge Control EnableOFF (default): Disable SOC Charge/Discharge Control
ON: Enable SOC Charge/Discharge Control (Note: This parameter must be enabled for d19 and d20 to take effect.)
d06Charging Source PriorityCSO: Solar priority charging
CUT: Utility priority charging
SNU (default): Solar and utility charge the battery together
OSO: Solar only charges the battery
d07Battery TypePb: Operate with lead-acid batteries (this setting enables float charging mode)
Li (default): Operate with lithium batteries (this setting disables float charging mode, and the maximum battery cutoff voltage is limited by parameter d15)
d08Maximum Inverter Output Power7KW (default): This parameter is factory-set according to the 7 kW unit specification and is not user-adjustable.
d09Rated Battery Voltage48V (default): This parameter is factory-set according to the 48V system specification and is not user-adjustable.
d10Restore Factory Default SettingsOFF (default): Do not restore factory default settings
ON: Restore factory default settings
d11Utility Mode Voltage Point Setting46.0V (default): When the inverter is operating in inverter mode, if the battery voltage falls below the set threshold, the system will automatically switch to grid mode. In this case, the load is supplied by the utility grid, and the inverter enters standby mode. The battery will no longer discharge energy to external loads. Setting range: 44-52V, with 0.1V increment per adjustment.
d12Battery Mode Voltage Point Setting53.0V (default): When the inverter is in standby mode, although the load is supplied by the grid, if solar MPPT charging or grid charging raises the battery voltage above the set threshold, the system will automatically switch back to inverter mode. In this case, the load is powered by the inverter, and both the battery and solar energy will supply power to the load. Any excess solar energy will be stored in the battery. Setting range: 48-56V, with 0.1V increment per adjustment. (Note: Parameters d11 and d12 are linked to the Output Source Priority settings. The SUB and SBU modes selected in parameter d01 operate according to the values of d11 and d12. To prevent improper configuration, the inverter verifies these parameter settings automatically. The voltage difference between d11 and d12 must be maintained at 4-5 V; otherwise, the inverter may switch repeatedly between inverter power and utility power.)
d13Utility Charging Current for Battery30A (default): Setting range: 0.5-60A, with 1A increment per adjustment. Note: Must be lower than the inverter's rated current.
d14Solar Charging Current for Battery80A (default): Setting range: 0-100A, with 1A increment per adjustment. Note: Must be lower than the inverter's rated current.
d15Bulk Charging Voltage56.0V (default): This parameter defines the final constant voltage level after the battery is fully charged. It is used to control the voltage maintenance level during the constant-voltage charging stage and is applicable to both lithium and lead-acid batteries. When parameter d07 is set to lead-acid battery mode, this value serves as the equalization charging voltage. The float charging voltage will follow a preset value of 13.8V per cell and operate automatically (the float voltage can be adjusted separately via the app). When parameter d07 is set to lithium battery mode, this value serves as the final equalization charging voltage. The battery voltage will be maintained at this set level to ensure cell balancing management. This parameter can be adjusted according to different battery specifications to meet actual system requirements. Setting range: 51-59V, with 0.1V increment per adjustment.
d16Zero Export Mode (Anti-backflow)ON (default): When Zero-Export Mode is enabled, the inverter supplies only the power required by the load. If the load demand exceeds the inverter's output capacity, the utility grid supplies the remaining power.
OFF: When Zero-Export Mode is disabled, surplus PV power can be exported to the utility grid.
d17System Power ON/OFF StatusON (default): The system is currently powered ON.
OFF: The system is currently powered OFF.
d18Maximum Output Current15.0A (default): This parameter defines the maximum AC output current of the inverter and must be set below the inverter's rated output current. For example, if the maximum output current is set to 15A at 220V, the corresponding maximum output power is approximately 3.3 kW (15A × 220V). In grid-connected anti-backflow (zero export) operation, this parameter is used to indirectly limit the inverter's output power by restricting the AC output current.
d19Charge SOC Threshold50% (default): When the battery SOC falls below the set threshold, the battery will start charging. The setting range is 0-100%, and the set value must be lower than the Discharge SOC. In general, it is recommended to set it 10% lower than the Discharge SOC. (Note: If the inverter is operating in discharge mode, battery discharging will stop when the battery SOC falls below this value.)
d20Discharge SOC Threshold100% (default): When the battery SOC exceeds the set threshold, the battery will start discharging. The setting range is 0-100%.
d21Battery Charge/Discharge Control0 (default): After the charging or discharging process is completed, this parameter will automatically reset to zero.
1: The system enters charging mode.
2: The system enters discharging mode.
d22Factory Test Mode SwitchOFF (default): This setting is reserved for factory use and cannot be changed by the user.
d23Zero-Export Activation Threshold70W (default): When the inverter detects that the load power exceeds 70W, the zero-export function is activated. If the load power is below 70W, the zero-export function remains inactive. In other words, zero-export control is applied only when the load power exceeds the configured activation threshold. Purpose: Allows users to adjust the zero-export activation threshold to compensate for sensor accuracy errors, thereby minimizing unintended power export to the utility grid.
d24External CT Zero-Export SwitchOFF (default): This model does not support an external CT. The load connected to the backup (off-grid) output must not exceed the inverter's rated output power. The built-in CT monitors the load power, allowing the inverter to regulate its output and provide hybrid power from both the utility grid and the inverter at the backup (off-grid) output. Setting range: 20-200W, with 10W increment per adjustment.
d25Parallel Power Balancing Parameter50 (default): When operating in parallel, if the output power among the inverters is unbalanced, this parameter can be adjusted to achieve more even load sharing.

4.2.5 Main Display Screen

Press the "Up" or "Down" buttons to preview the main display screens.

Main display screen example 1
Figure 13: Main Display Screen showing AC input voltage (0V), current page (Page 0), AC output voltage (219V), PV MPPT charging, and float charging mode.
Main display screen example 2
Figure 14: Main Display Screen showing current inverter AC output current (6.4 A), current page (Page 1), current output power (1.4KW), and charging in progress.

Additional display screens show:

  • Page 2: Current inverter temperature (e.g., 31.3°C), inverter output frequency (e.g., 50Hz), and indication of load supplied by battery power.
  • Page 3: Current battery voltage (e.g., 28.2V), battery DC current, and indication of constant-voltage equalization charging mode.
  • Page 4: Current PV voltage (e.g., 58.2V), displayed PV current value (e.g., 1.1A), and indication of constant-voltage equalization charging mode.
  • Page 5: Current MPPT temperature (e.g., 29.3°C), current solar power generation (e.g., 33.3Wh), and indication of constant-voltage equalization charging mode.
  • Page 6: Current internal high voltage of the inverter (e.g., 419V), accumulated power generation (e.g., 20.3Wh, switches to kWh if >1kWh), and indication of float charging mode.
  • Page 7: Current battery SOC display, current battery SOH display, and indication of float charging mode.

4.3 Communication Wiring Between the Inverter and BMS

The inverter supports communication with a Battery Management System (BMS).

4.3.1 Inverter Communication Port Pin Definition (RJ45)

RJ45 Pin Definitions for BMS Communication
RJ45 PinDefinition
Pin 1/
Pin 2/
Pin 3/
Pin 4CAN-H (Internal BMS Communication)
Pin 5CAN-L (Internal BMS Communication)
Pin 6/
Pin 7/
Pin 8/

4.3.2 Communication Wiring Between the Inverter and BMS

  1. Inverter communication board network port pin4 (CAN-H) connects to network interface board BMS port pin x (CAN-H);
  2. Inverter communication board network port pin5 (CAN-L) connects to network interface board BMS port pin x (CAN-L);
BMS communication wiring diagram
Figure 15: Diagram showing BMS communication wiring from the inverter's BMS port to an external BMS CAN port.

5. Fault Codes and Troubleshooting

When a fault occurs, the device displays a fault code. Refer to the table below for detailed descriptions of fault codes, their causes, and recommended solutions.

Fault Codes, Causes, and Solutions
Fault CodeFault StatusCause and DescriptionSolution
E0Input undervoltage protectionUtility input voltage is too low.If a wider utility voltage range is required, set d02 to WID. If the problem still cannot be resolved after setting d02 to WID, check whether the input voltage is too low.
E1Input overvoltage protectionUtility input voltage is too high.If a wider utility voltage range is required, set d02 to WID. If the problem still cannot be resolved after setting d02 to WID, check whether the input voltage is too high.
E2Input over-frequency protectionInput frequency exceeds the preset frequency range.For 50Hz systems, the acceptable input frequency range is 45Hz-55Hz. For 60Hz systems, the acceptable input frequency range is 55Hz-65Hz. If the system frequency exceeds 65Hz, an over-frequency fault will be triggered. Check the utility grid frequency.
E3Input Underfrequency ProtectionThe input frequency is outside the preset operating range.For 50Hz systems, the acceptable input frequency range is 45Hz-55Hz. For 60Hz systems, the acceptable input frequency range is 55Hz-65Hz. If the system frequency falls below 45Hz, an over-frequency fault alarm will be triggered. Please check the utility grid frequency.
E4Frequent Grid SwitchingExcessive switching between utility mode and inverter mode is one of the most common issues encountered in energy storage applications. The root cause is usually poor battery performance.1. Battery-related causes: When the battery is supplying a heavy load and the battery voltage drops below the d11 setting, the inverter automatically transfers to utility mode. If PV charging continues, the battery voltage may recover quickly and exceed the d12 setting, causing the inverter to switch back to inverter mode. This repeated transition can result in more than 8 switching events within one hour.
2. Poor battery performance: If the battery has limited performance (such as a lead-acid battery) while supplying a high load, it is recommended to use SBU/SUB mode, set d11 to the lowest value, and set d12 to the highest value in order to reduce the switching frequency.
3. Use a higher-performance battery: Replacing the battery with a higher-performance lithium battery can effectively resolve this issue. After this fault code is triggered, the inverter will lock the current operating state for one hour and then automatically recover. During this period, the inverter may stop operating.
4. Battery voltage rebound effect: Users often assume the battery still has sufficient capacity because the displayed voltage appears normal. However, this may only be a temporarily elevated voltage with little actual capacity available. When a load is applied, the battery voltage can drop rapidly and trigger inverter protection.
E5Inverter Short CircuitThe inverter has detected a short-circuit fault.Please disconnect the load from the inverter and carefully inspect the load for any short-circuit points. It is recommended to connect the inverter output to the load through a circuit breaker, as the circuit breaker also provides protection.
E6Inverter OverloadThe inverter has encountered an overcurrent/overload fault.1. When the inverter is operating in off-grid mode, please check whether the load is overloaded or whether the load current is too high.
2. When the inverter is operating in charging mode, please check whether the charging current is set too high, or whether a short-circuit condition exists on the battery side.
3. When the inverter is operating in grid-tied mode, please check whether the grid-tied current setting is too high.
E7Inverter Bus OvervoltageAbnormal utility grid voltage.Please check the external AC input voltage. Excessively high utility voltage may cause inverter faults. Disconnect the inverter from the external AC power source if the utility voltage is abnormal.
E8PV1 Input OvervoltageThe operating voltage of the solar panels connected to the PV1 terminal is too high.Please check the operating voltage of the solar panels. A recommended open-circuit voltage of approximately 400V is considered optimal.
E9PV2 Input OvervoltageThe operating voltage of the solar panels connected to the PV2 terminal is too high.Please check the operating voltage of the solar panels. A recommended open-circuit voltage of approximately 400V is considered optimal.
EAPV1 Overcurrent ProtectionAn overcurrent condition has occurred at the PV1 input terminal.Please check the operating voltage of the solar panels. A recommended open-circuit voltage of approximately 400V is considered optimal. Also check whether the PV terminals have been incorrectly connected or damaged.
EBPV2 Overcurrent ProtectionAn overcurrent condition has occurred at the PV2 input terminal.Please check the operating voltage of the solar panels. A recommended open-circuit voltage of approximately 400V is considered optimal. Also check whether the PV terminals have been incorrectly connected or damaged.
ECCharging Overcurrent ProtectionDuring charging, the battery current exceeds the inverter's rated current.Please check whether the battery is damaged or whether a short circuit exists at the battery terminals.
EDCharging Overvoltage ProtectionThe battery terminal voltage is too high.Please check whether parameter D15 is set too high, or whether the battery terminal voltage is excessively high.
EEBattery Voltage ProtectionThe battery voltage has exceeded the preset parameter value, or the battery is fully discharged.1. The battery may have been disconnected from the inverter. Please check the battery wiring and grounding connections. For lithium batteries, the BMS may have disconnected the battery.
2. The battery may already be fully discharged or unable to support heavy loads. In this case, it is recommended to replace it with a higher-performance battery.
EFINV Overtemperature ProtectionThe inverter temperature has exceeded 85°C.Please ensure proper ventilation and heat dissipation, use the correct installation method, and wait for the inverter to cool down and recover automatically.
EGMPPT1 Overtemperature ProtectionThe MPPT1 temperature has exceeded 85°C.Please ensure proper ventilation and heat dissipation, use the correct installation method, and wait for the inverter to cool down and recover automatically.
EHMPPT2 Overtemperature ProtectionThe MPPT2 temperature has exceeded 85°C.Please ensure proper ventilation and heat dissipation, use the correct installation method, and wait for the inverter to cool down and recover automatically.
EIBMS FaultA fault has occurred in the battery BMS.The BMS connection has been disconnected. Please reconnect it.

Note: Displaying "99" indicates normal status.

6. Maintenance

To maintain optimum and long-lasting working performance, we recommend that the following items are checked twice a year.

  1. Ensure that the airflow around the inverter is not blocked and remove any dirt or debris from the radiator.
  2. Check that all exposed conductors are not damaged by sunlight, friction with other surrounding objects, dry rot, insect or rodent damage, etc. The conductors need to be repaired or replaced if necessary.
  3. Verify that the indications and displays are consistent with the operation of the equipment, note any faults or incorrect displays and take corrective action if necessary.
  4. Check all terminals for signs of corrosion, insulation damage, high temperatures or burning/discoloration and tighten terminal screws.
  5. Check for dirt, nesting insects and corrosion, clean as required, Clean the insect screen regularly.
  6. If the lightning arrester has failed, replace the failed arrester in time to prevent lightning damage to the inverter or other equipment of the user.

DANGER: Before conducting any inspection or operation, please ensure that the inverter is disconnected from all power sources and that the capacitor is fully discharged to avoid the risk of electric shock.

7. Specifications

PowMr Hybrid Solar Inverter Specifications (Model: POW-HVM7K-48V)
CategoryParameterValue
AC InputRated voltage230Vac
Voltage range170-270Vac (UPS); 90-280Vac (APL)
Maximum input voltage280VAC
Rated input frequency50Hz/60Hz (Adaptive)
Frequency range40-65Hz
Transfer range10ms (UPS); 20ms (APL)
Maximum AC charging current60A
AC OutputRated output capacity7KW
Rated output voltage220/230/240Vac
Voltage accuracy±5%
Rated output frequency50Hz/60Hz
Frequency accuracy±2%
Output waveform distortion (THD)≤3% (100% linear load)
Power factor1
Maximum conversion efficiency94.2%
Grid-connected output overload current50A
Off-grid Load Capacity110% < Load < 150% (±10%)Alarm and shutdown after 10 seconds
150% < Load < 200% (±10%)Alarm and shutdown after 5 seconds
Load > 200% (±10%)Immediate alarm and shutdown
BatteryBattery typeLead-acid / Lithium battery
Rated input voltage48VDC
Battery voltage range46.4-58.8V
Maximum charging current135A
Float charging voltage53.5V (Lead-acid); User-defined for Lithium Battery
Equalization charging voltage56.5V (Lead-acid); User-defined for Lithium Battery
PV InputMaximum PV input power7000W
Maximum PV input current25A
Nominal operating voltage360Vdc
PV input voltage range100-450VDC
Maximum PV input voltage450VDC
Maximum PV charging current120A
General ParametersDimensions385*320*105mm
Net Weight7.7kg
Noise≤48dB
Operating temperature range-20°C~+50°C
Storage temperature-15°C~+65°C
Operating humidity range0~90% (Non-condensing)
Operating altitude≤6000m
ProtectionBattery overvoltage protectionYes
Overload protectionYes
Output short-circuit protectionYes
Over-temperature protectionYes

8. Appendix: Parallel Connection

The inverter supports up to 6 units of single-phase parallel connection for expanded output power, without the need for external parallel communication cables.

8.1 Cautions for Parallel Connection

  1. PV wiring: In parallel connection, the PV array of each inverter must be independent.
  2. Battery wiring: In a parallel system, all solar inverters may be connected to a common battery bank or to separate battery banks. Ensure that the battery polarity is connected correctly (BAT+ to BAT+ and BAT- to BAT- where applicable). Before power-on and start-up, verify that all battery connections, cable lengths, and cable sizes are correct and properly matched to prevent abnormal operation of the parallel system.
  3. AC OUT wiring: In single-phase parallel connection, all solar inverters must be connected in the manner of L-to-L, N-to-N, and PE-to-PE, and before power on and start-up, it is necessary to check and ensure correct connection, wiring length, and cable size, so as to avoid the abnormal operation of parallel system output caused by wrong connection.
  4. AC IN wiring: In single-phase parallel connection, all solar inverters must be connected in the manner of L-to-L, N-to-N, and PE-to-PE, and before power on and start-up, it is necessary to check and ensure correct connection, wiring length, and cable size, so as to avoid the abnormal operation of parallel system output caused by wrong connection. Meanwhile, it is not allowed to have multiple different AC source inputs to avoid damage to the external equipment of the inverter. The AC source input shall be consistent and unique.
  5. Before and after connecting the system, please carefully refer to the following system wiring diagrams to ensure that all wiring is correct and reliable before power on.
  6. After the system is correctly wired, powered on, and in normal operation, if a new inverter needs to be connected, make sure to disconnect the battery input, PV input, AC input and AC output, and that all solar inverters are powered off before reconnecting into the system.

8.2 Single-Phase Parallel System Diagram

Two inverters in parallel:

Two inverters parallel connection diagram
Figure 16: Wiring diagram for two inverters connected in parallel, showing battery, utility, and load connections.

Three inverters in parallel:

Three inverters parallel connection diagram
Figure 17: Wiring diagram for three inverters connected in parallel.

Four inverters in parallel:

Four inverters parallel connection diagram
Figure 18: Wiring diagram for four inverters connected in parallel.

Five inverters in parallel:

Five inverters parallel connection diagram
Figure 19: Wiring diagram for five inverters connected in parallel.

Six inverters in parallel:

Six inverters parallel connection diagram
Figure 20: Wiring diagram for six inverters connected in parallel.

9. User Tips

  • Check Package Contents: Some users noted that cables might not be included, so verify all necessary components upon arrival.
  • Wi-Fi Module: The Wi-Fi functionality is provided via a separate module, not built-in. Ensure it is properly connected if remote monitoring is desired.
  • Battery Compatibility: The inverter supports both 12V, 24V, and 48V battery systems depending on the model (e.g., 2.5KW 12V, 3.5KW 24V, 7KW 48V, 13.2KW 48V). Ensure your battery voltage matches the inverter model.
  • Charging Options: The inverter supports charging from solar, utility grid, and generators. Configure the charging source priority (d06 setting) according to your needs.
  • System Sizing: When considering solar panels, ensure the open circuit voltage (Voc) does not exceed 450VDC and is above 150VDC for optimal performance.

10. Warranty and Support

For technical support, warranty claims, or further assistance, please contact PowMr customer service:

  • Email: support@powmr.com
  • Website: www.powmr.com
  • Address: Henggang Street, Longgang District, Shenzhen, Guangdong, China