DATOUBOSS DT-4855U

Contents

DATOUBOSS 48V 5500W Solar Hybrid Inverter

Model: DT-4855U

Brand: DATOUBOSS

1. Introduction

This manual provides detailed instructions for the assembly, installation, operation, and troubleshooting of your DATOUBOSS 48V 5500W Solar Hybrid Inverter. Please read this manual carefully before installation and operation, and keep it for future reference.

The DATOUBOSS 48V 5500W Solar Hybrid Inverter is a versatile, all-in-one energy storage solution that integrates an inverter, solar charger, and battery charger. It provides uninterruptible power support in a compact size, featuring a comprehensive LCD display for user-configurable settings such as battery charging current, AC/solar charger priority, and acceptable input voltage ranges.

Important Note on Branding:

Our brand utilizes two logos: DATOUBOSS and MFUZOP. While DATOUBOSS is our classic version, new orders may be shipped with the MFUZOP logo due to stock availability. Both logo variants feature identical internal hardware, specifications, performance, warranty, and after-sales service. They are genuine official products with no differences in quality or grade. If the logo appearance is a concern, please consider this before placing an order.

DATOUBOSS and MFUZOP branded inverters side-by-side

Image: Comparison of DATOUBOSS and MFUZOP branded solar inverters, showing identical design apart from the logo.

2. Safety Instructions

WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.

  1. Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
  2. CAUTION: To reduce risk of injury, charge only deep-cycle lead-acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
  3. Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
  4. To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
  5. CAUTION: Only qualified personnel can install this device with battery.
  6. NEVER charge a frozen battery.
  7. For optimum operation of this inverter/charger, please follow required specifications to select appropriate cable size. It's very important to correctly operate this inverter/charger.
  8. Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts and could cause an explosion.
  9. Please strictly follow installation procedure when you want to disconnect AC or DC terminals. Refer to the INSTALLATION section of this manual for details.
  10. One piece of 150A fuse is provided as over-current protection for the battery supply.
  11. GROUNDING INSTRUCTIONS: This inverter/charger should be connected to a permanent grounder wiring system. Be sure to comply with local requirements and regulations to install this inverter.
  12. NEVER cause AC output and DC input short circuited. Do NOT connect to the mains when DC input short circuits.
  13. Warning! Only qualified service persons are able to service this device. If errors still persist after following troubleshooting table, please send this inverter/charger back to local dealer or service center for maintenance.

3. Product Overview and Features

The DATOUBOSS 48V 5500W Solar Hybrid Inverter is designed for high performance and reliability in home energy systems. It integrates multiple functions to provide a seamless power solution.

Key Features:

  • Pure sine wave output for sensitive electronics.
  • Configurable input voltage range for home appliances and personal computers.
  • Configurable battery charging current based on application needs.
  • Configurable AC/Solar Charger priority.
  • Compatibility with mains voltage or generator power.
  • Auto-restart function when AC is recovering.
  • Comprehensive protection: Overload, Over-temperature, Short-circuit.
  • Smart battery charger design for optimized battery performance.
  • Cold start function.
DATOUBOSS 48V 5500W Solar Hybrid Inverter with key features

Image: Front view of the DATOUBOSS 48V 5500W Solar Hybrid Inverter highlighting MPPT Solar Charge Controller, 5500W Pure Sine Wave Inverter, and UPS Uninterruptible Power Supply features.

Comprehensive Security Protection System of the inverter

Image: Diagram illustrating the comprehensive security protection system, including low-voltage, overcurrent, short-circuit, overload, overvoltage, overcharge, over-temperature, and reverse connection protection.

Video: A brief overview of the DATOUBOSS 48V 5500W Solar Hybrid Inverter, showcasing its features and design.

4. Setup (Installation)

4.1 Unpacking and Inspection

Before installation, carefully inspect the unit. Ensure that nothing inside the package is damaged. The package should contain: The inverter unit x 1, User manual x 1.

4.2 Preparation

Before connecting any wires, remove the bottom cover of the inverter by unscrewing the two retaining screws.

4.3 Mounting the Unit

Consider the following points when selecting an installation location:

  • Do not mount the inverter on flammable construction materials.
  • Mount on a solid surface.
  • Install at eye level for easy LCD display readability.
  • Allow approximately 20 cm clearance on the sides and 50 cm above and below for proper air circulation and heat dissipation.
  • Ambient temperature should be between 20°C and 35°C for optimal operation.
  • Adhere to vertical wall mounting.
  • Ensure sufficient space for heat dissipation and wire routing.

SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.

Install the unit by screwing three screws:

  • Use M6*80mm expansion bolts for two mounting points.
  • Use M4 or M5 for the third mounting point.
Dimensions of the DATOUBOSS 48V 5500W Solar Hybrid Inverter

Image: Dimensions of the inverter: 49.5cm (Height), 31.2cm (Width), 12.5cm (Depth), and weight 11.46kg.

4.4 Battery Connection

CAUTION: For safety and compliance, install a separate DC over-current protector or disconnect device between the battery and inverter.

WARNING: All wiring must be performed by qualified personnel. Use appropriate cable for battery connection to reduce risk of injury.

Rated CapacityTypical AmperageBattery CapacityWire SizeCable (mm²)Ring Terminal D (mm)Ring Terminal L (mm)Torque Value
5.5KVA127A200AH1*2AWG346.439.22~3 Nm
2*6AWG146.433.2

Battery Connection Steps:

  1. Assemble battery ring terminals based on the recommended cable and terminal size.
  2. Insert the battery wires flatly into the inverter's battery connectors. Ensure bolts are tightened with a torque of 2 Nm in a clockwise direction. Verify correct polarity at both the battery and the inverter/charger, and ensure conductors are tightly screwed into the battery terminals. Recommended tool: #2 Pozi Screwdriver.

4.5 AC Input/Output Connection

CAUTION: Before connecting to the AC input power source, install a separate AC breaker between the inverter and the AC input power source. This protects the inverter during maintenance and from over-current.

CAUTION: There are two terminal blocks labeled "IN" and "OUT". Do NOT mis-connect input and output connectors.

WARNING: All wiring must be performed by qualified personnel. Use appropriate cable for AC input connection to reduce risk of injury.

Suggested Cable Requirement for AC Wires:

Rated CapacityGaugeTorque Value
5.5KVA8AWG1.4~1.6Nm

AC Input/Output Connection Steps:

  1. Before making AC input/output connections, ensure the DC protector or disconnector is open.
  2. Remove 10mm of insulation sleeve for six conductors. Shorten phase L and neutral conductor N3 mm.
  3. Insert AC input wires according to indicated polarities on the terminal block and tighten the terminal screws. Connect the PE protective conductor (Ground) first.
  4. Ensure all wires are securely connected.

4.6 PV Connection (Solar Charger Model Only)

CAUTION: Before connecting to PV modules, install a separate DC circuit breaker between the inverter and PV modules.

WARNING: All wiring must be performed by qualified personnel. Use appropriate cable for PV module connection to reduce risk of injury.

Typical AmperageGaugeTorque Value
30A12AWG1.4~1.6Nm

PV Module Selection:

When choosing PV modules, consider these requirements:

  • The open circuit voltage (Voc) of the PV modules must not exceed the maximum PV array open circuit voltage of the inverter.
  • The maximum supply voltage of the PV modules should be close to the optimal PV access voltage range of the inverter for best performance.
  • If one PV module cannot meet requirements, connect multiple PV modules in series.
ParameterValue (DT4855U)
PV Charging ModeMPPT
MAX. PV Input Power8500W
MPPT Tracking Range60-500Vdc
Best Voltage360-430V
MAX. PV Input Voltage500Vdc
PV Max Input Current27A
MAX. PV Charging Current100A
MAX. AC Charging Current40A
MAX. Charging Current100A

PV Module Wire Connection Steps:

  1. Remove 10 mm of insulation sleeve for positive and negative conductors.
  2. Use bootlace ferrules on the ends of positive and negative wires with a proper crimping tool.
  3. Fix the wire cover to the inverter with supplied screws.
  4. Check correct polarity from PV modules and PV input connectors. Connect positive to positive and negative to negative. Screw wires tightly in a clockwise direction. Recommended tool: 4mm blade screwdriver.

4.7 Final Assembly

After connecting all wirings, replace the bottom cover by screwing the two retaining screws.

Back panel connections diagram of the inverter

Image: Detailed diagram of the inverter's back panel showing all connection points: 1. AC Input, 2. AC Output, 3. Communication Port, 4. BMS/RS485 Communication Port, 5. Dry Contact, 6. Battery Input, 7. Power On/Off Switch, 8. PV Input, 9. Input Circuit Breaker, 10. Cooling Fan, 11. Battery Terminal (+), 12. Battery Terminal (-), 13. Solar Panel Input, 14. AC Main/Secondary Output, 15. Output Ground Terminal, 16. CT Signal Port.

RS232 and RS485 communication ports and pin assignments

Image: Close-up of RS232 and RS485 communication ports. RS485 pin assignments are shown: Pin 1 to 485B, Pin 2 to 485A.

5. Operating

5.1 Power On/Off

Once the unit is properly installed and batteries are connected, press the On/Off switch (located on the bottom of the case) to turn on the unit.

Steps to Start Up:

  1. Connect the battery (voltage needs to be beyond 23V) or AC (AC needs to confirm suitable input range).
  2. Mains Power On: Connect to normal AC power, press the switch. The system will automatically turn on. If AC output power priority is set, the panel will display AC mode after a period, indicating successful startup.
  3. Battery Boot: Connect to battery, press the power-on switch. The system will automatically turn on. If battery mode is set, the panel will display battery mode after a period, indicating successful startup.

Shutdown Steps:

When the system is in battery mode or AC mode output, press the switch again to turn off the system.

5.2 Operation and Display Panel

The front panel features three indicators, four function keys, and an LCD display to show operating status and input/output power information.

LCD display and control buttons of the inverter

Image: Close-up of the inverter's LCD display and control panel. Labels: 1. LCD display, 2. Status indicator, 3. Charging indicator, 4. Fault indicator, 5. ESC button, 6. UP button, 7. DOWN button, 8. ENTER button.

LED Indicators:

IndicatorColorStatusMessage
AC/INVGreenSolid OnOutput powered by utility (Line mode)
FlashingOutput powered by battery or PV (Battery mode)
CHGYellowSolid OnBattery fully charged
FlashingBattery is charging
FAULTRedSolid OnFault occurs in the inverter
FlashingWarning condition occurs in the inverter

Function Keys:

KeyDescription
ESCTo exit setting mode
UPTo go to previous selection
DOWNTo go to next selection
ENTERTo confirm selection in setting mode or enter setting mode

5.3 LCD Setting

To enter setting mode, press and hold the ENTER button for 3 seconds. Use the "UP" or "DOWN" buttons to select setting programs. Press "ENTER" to confirm a selection or "ESC" to exit.

Setting Programs (Examples):

  • Program 00: Exit Setting Mode
  • Program 01: Output Source Priority Selection (e.g., Solar first, Solar and Utility, Solar only, Solar residual, etc.)

5.4 Operating Mode Description

The inverter operates in various modes depending on power availability and settings:

Standby Mode:

The inverter is not yet turned on, but can charge the battery without AC output. It can also enter a "Power Swing Mode" where output is off if the connected load is very low.

Line Mode:

When utility power is available, the inverter can charge the battery, power loads, and even feed excess solar energy back to the grid, depending on configuration.

6. Maintenance

To ensure optimal performance and longevity of your inverter, regular maintenance is recommended:

  • Keep the inverter's ventilation openings clear of dust and debris to prevent overheating.
  • Periodically check all wiring connections for tightness and signs of corrosion.
  • Ensure the battery terminals are clean and free from corrosion.
  • Inspect the unit for any visible damage or unusual noises.
  • If the unit is installed in a dusty environment, consider occasional cleaning of the exterior with a soft, dry cloth.

7. Troubleshooting

This section provides guidance for common issues. If problems persist, contact customer support.

7.1 Trouble Removal

ProblemLCD/LED/BuzzerExplanation/Possible CauseWhat to Do
Unit shuts down automatically during startupLCD/LEDs and buzzer active for 3s, then offBattery voltage too low (<1.91V/Cell)1. Re-charge battery. 2. Replace battery.
No response after power onNo indication1. Battery voltage too low (<1.4V/Cell). 2. Internal fuse tripped.1. Contact repair center for fuse replacement. 2. Re-charge battery.
Input voltage 0 on LCD, green LED flashingInput protector tripped3. Replace battery. Check AC breaker and wiring.
Mains exist but unit works in battery modeGreen LED flashingInsufficient quality of AC power1. Check AC wires (too thin/long). 2. Check generator/input voltage range setting.
Green LED flashingSet "Solar First" as output priorityChange output source priority to Utility first.
When unit turns on, internal relay switches on/off repeatedlyLCD display and LEDs flashingBattery disconnectedCheck battery wires.
Buzzer beeps continuously, red LED onFault code 07Overload error / PV input voltage too highReduce connected load / Reduce PV modules in series.
Fault code 05Output short circuitedCheck wiring, remove abnormal load.
Fault code 02Internal converter component over-temperatureCheck airflow, ambient temperature.
Fault code 03Battery over-charged / voltage too highReturn to repair center / Check battery specs.
Fault code 01Fan faultReplace the fan.
Fault code 06/58Output abnormal (Inverter voltage out of range)1. Reduce connected load. 2. Return to repair center.
Fault code 08/09/53/57Internal components failedReturn to repair center.
Fault code 51Over current or surgeRestart unit, if error persists, return to repair center.
Fault code 52Bus voltage too lowRestart unit, if error persists, return to repair center.
Fault code 55Output voltage unbalancedRestart unit, if error persists, return to repair center.
Fault code 59PV input voltage beyond specificationReduce number of PV modules in series.

7.2 Fault and Alarm Descriptions

Faults:

When a fault occurs, the inverter enters fault mode, the red LED light is always on, and the LCD displays a fault code. Refer to the manual's fault reference code table for specific codes and their meanings.

Alarms:

When an alarm occurs, the red LED flashes, and the LCD displays an alarm code. The inverter does not enter failure mode during an alarm. Refer to the manual's alarm indicator table for specific codes, audible alarms, and flashing icons.

Code Reference:

Related information codes may be displayed on the LCD screen. Consult the manual's code reference section for detailed explanations of these codes.

8. Specifications

Detailed technical specifications for the DATOUBOSS 48V 5500W Solar Hybrid Inverter.

Product Specifications label on the inverter

Image: Close-up of the product specification label on the inverter, detailing model, power, voltage, temperature range, and other electrical parameters.

CategoryParameterValue (DT4855U)
InputInput SourcesL+N+PE
Rated Input Voltage110/120VAC
Voltage Range65-145VAC±3V
Frequency50/60Hz±0.1%
OutputRated Power (Battery Invert)5500W
Rated Power (Photovoltaic Invert)5500W
Output Voltage110/120VAC±5%
Output Frequency50/60Hz±0.1%
Grid-Connected OperationWaveformPure Sine Wave
Transfer Time (adjustable)Computers (UPS Mode) 10ms, Appliance (APL Mode) 20ms
Peak Power11000VA
Overload CapacityBattery mode: 11s@105%~150% Load; 2s@150%~200% Load; 400ms@>200% Load
Nominal Output Current50A
Maximum Conversion Efficiency (DC/AC)98%
BatteryBattery Voltage48Vdc
Constant Charging Voltage (Adjustable)56.4Vdc
Float Charging Voltage (Adjustable)54Vdc
ChargersPV Charging ModeMPPT
MAX. PV Input Power8500W
MPPT Tracking Range60-500Vdc
Best Voltage360~430Vdc
MAX. PV Input Voltage500Vdc
MAX. PV Charging Current100A
MAX. AC Charging Current40A
InterfaceRS232Baud Rate 2400
Extend Socket Communication InterfaceLithium Battery BMS Communication Card, Wifi Card, Dry Contact
EnvironmentOperating Temperature-10-50°C
Humidity20%-95% (Non-condensing)
Storage Temperature-15-60°C
Noise≤50db
Dimensions & WeightSize (L*W*H) / Weight49.5cm × 31.2cm × 12.5cm / 11.46kg

9. User Tips

  • Always thoroughly read the entire user manual before attempting installation or operation to ensure proper setup and avoid potential issues.
  • Double-check all wiring connections, especially polarity for batteries and PV modules, to prevent damage to the inverter and connected components.
  • Ensure your battery bank and PV array specifications (voltage, current) are compatible with the inverter's requirements to optimize performance and prevent overloading.

10. Warranty and Support

The DATOUBOSS 48V 5500W Solar Hybrid Inverter comes with a 3-year warranty from the date of purchase.

For technical support, warranty claims, or if you encounter issues not covered in the troubleshooting section, please contact your authorized DATOUBOSS dealer or the seller directly. Provide your product model number and purchase details for faster service.

© 2023 DATOUBOSS. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.