1. Introduction
This manual provides detailed instructions for the assembly, installation, operation, and troubleshooting of your DATOUBOSS 48V 5500W Solar Hybrid Inverter. Please read this manual carefully before installation and operation, and keep it for future reference.
The DATOUBOSS 48V 5500W Solar Hybrid Inverter is a versatile, all-in-one energy storage solution that integrates an inverter, solar charger, and battery charger. It provides uninterruptible power support in a compact size, featuring a comprehensive LCD display for user-configurable settings such as battery charging current, AC/solar charger priority, and acceptable input voltage ranges.
Important Note on Branding:
Our brand utilizes two logos: DATOUBOSS and MFUZOP. While DATOUBOSS is our classic version, new orders may be shipped with the MFUZOP logo due to stock availability. Both logo variants feature identical internal hardware, specifications, performance, warranty, and after-sales service. They are genuine official products with no differences in quality or grade. If the logo appearance is a concern, please consider this before placing an order.

Image: Comparison of DATOUBOSS and MFUZOP branded solar inverters, showing identical design apart from the logo.
2. Safety Instructions
WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.
- Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
- CAUTION: To reduce risk of injury, charge only deep-cycle lead-acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
- Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
- To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
- CAUTION: Only qualified personnel can install this device with battery.
- NEVER charge a frozen battery.
- For optimum operation of this inverter/charger, please follow required specifications to select appropriate cable size. It's very important to correctly operate this inverter/charger.
- Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts and could cause an explosion.
- Please strictly follow installation procedure when you want to disconnect AC or DC terminals. Refer to the INSTALLATION section of this manual for details.
- One piece of 150A fuse is provided as over-current protection for the battery supply.
- GROUNDING INSTRUCTIONS: This inverter/charger should be connected to a permanent grounder wiring system. Be sure to comply with local requirements and regulations to install this inverter.
- NEVER cause AC output and DC input short circuited. Do NOT connect to the mains when DC input short circuits.
- Warning! Only qualified service persons are able to service this device. If errors still persist after following troubleshooting table, please send this inverter/charger back to local dealer or service center for maintenance.
3. Product Overview and Features
The DATOUBOSS 48V 5500W Solar Hybrid Inverter is designed for high performance and reliability in home energy systems. It integrates multiple functions to provide a seamless power solution.
Key Features:
- Pure sine wave output for sensitive electronics.
- Configurable input voltage range for home appliances and personal computers.
- Configurable battery charging current based on application needs.
- Configurable AC/Solar Charger priority.
- Compatibility with mains voltage or generator power.
- Auto-restart function when AC is recovering.
- Comprehensive protection: Overload, Over-temperature, Short-circuit.
- Smart battery charger design for optimized battery performance.
- Cold start function.

Image: Front view of the DATOUBOSS 48V 5500W Solar Hybrid Inverter highlighting MPPT Solar Charge Controller, 5500W Pure Sine Wave Inverter, and UPS Uninterruptible Power Supply features.

Image: Diagram illustrating the comprehensive security protection system, including low-voltage, overcurrent, short-circuit, overload, overvoltage, overcharge, over-temperature, and reverse connection protection.
Video: A brief overview of the DATOUBOSS 48V 5500W Solar Hybrid Inverter, showcasing its features and design.
4. Setup (Installation)
4.1 Unpacking and Inspection
Before installation, carefully inspect the unit. Ensure that nothing inside the package is damaged. The package should contain: The inverter unit x 1, User manual x 1.
4.2 Preparation
Before connecting any wires, remove the bottom cover of the inverter by unscrewing the two retaining screws.
4.3 Mounting the Unit
Consider the following points when selecting an installation location:
- Do not mount the inverter on flammable construction materials.
- Mount on a solid surface.
- Install at eye level for easy LCD display readability.
- Allow approximately 20 cm clearance on the sides and 50 cm above and below for proper air circulation and heat dissipation.
- Ambient temperature should be between 20°C and 35°C for optimal operation.
- Adhere to vertical wall mounting.
- Ensure sufficient space for heat dissipation and wire routing.
SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.
Install the unit by screwing three screws:
- Use M6*80mm expansion bolts for two mounting points.
- Use M4 or M5 for the third mounting point.

Image: Dimensions of the inverter: 49.5cm (Height), 31.2cm (Width), 12.5cm (Depth), and weight 11.46kg.
4.4 Battery Connection
CAUTION: For safety and compliance, install a separate DC over-current protector or disconnect device between the battery and inverter.
WARNING: All wiring must be performed by qualified personnel. Use appropriate cable for battery connection to reduce risk of injury.
Recommended Battery Cable and Terminal Size:
| Rated Capacity | Typical Amperage | Battery Capacity | Wire Size | Cable (mm²) | Ring Terminal D (mm) | Ring Terminal L (mm) | Torque Value |
|---|---|---|---|---|---|---|---|
| 5.5KVA | 127A | 200AH | 1*2AWG | 34 | 6.4 | 39.2 | 2~3 Nm |
| 2*6AWG | 14 | 6.4 | 33.2 |
Battery Connection Steps:
- Assemble battery ring terminals based on the recommended cable and terminal size.
- Insert the battery wires flatly into the inverter's battery connectors. Ensure bolts are tightened with a torque of 2 Nm in a clockwise direction. Verify correct polarity at both the battery and the inverter/charger, and ensure conductors are tightly screwed into the battery terminals. Recommended tool: #2 Pozi Screwdriver.
4.5 AC Input/Output Connection
CAUTION: Before connecting to the AC input power source, install a separate AC breaker between the inverter and the AC input power source. This protects the inverter during maintenance and from over-current.
CAUTION: There are two terminal blocks labeled "IN" and "OUT". Do NOT mis-connect input and output connectors.
WARNING: All wiring must be performed by qualified personnel. Use appropriate cable for AC input connection to reduce risk of injury.
Suggested Cable Requirement for AC Wires:
| Rated Capacity | Gauge | Torque Value |
|---|---|---|
| 5.5KVA | 8AWG | 1.4~1.6Nm |
AC Input/Output Connection Steps:
- Before making AC input/output connections, ensure the DC protector or disconnector is open.
- Remove 10mm of insulation sleeve for six conductors. Shorten phase L and neutral conductor N3 mm.
- Insert AC input wires according to indicated polarities on the terminal block and tighten the terminal screws. Connect the PE protective conductor (Ground) first.
- Ensure all wires are securely connected.
4.6 PV Connection (Solar Charger Model Only)
CAUTION: Before connecting to PV modules, install a separate DC circuit breaker between the inverter and PV modules.
WARNING: All wiring must be performed by qualified personnel. Use appropriate cable for PV module connection to reduce risk of injury.
Recommended PV Module Cable Size:
| Typical Amperage | Gauge | Torque Value |
|---|---|---|
| 30A | 12AWG | 1.4~1.6Nm |
PV Module Selection:
When choosing PV modules, consider these requirements:
- The open circuit voltage (Voc) of the PV modules must not exceed the maximum PV array open circuit voltage of the inverter.
- The maximum supply voltage of the PV modules should be close to the optimal PV access voltage range of the inverter for best performance.
- If one PV module cannot meet requirements, connect multiple PV modules in series.
| Parameter | Value (DT4855U) |
|---|---|
| PV Charging Mode | MPPT |
| MAX. PV Input Power | 8500W |
| MPPT Tracking Range | 60-500Vdc |
| Best Voltage | 360-430V |
| MAX. PV Input Voltage | 500Vdc |
| PV Max Input Current | 27A |
| MAX. PV Charging Current | 100A |
| MAX. AC Charging Current | 40A |
| MAX. Charging Current | 100A |
PV Module Wire Connection Steps:
- Remove 10 mm of insulation sleeve for positive and negative conductors.
- Use bootlace ferrules on the ends of positive and negative wires with a proper crimping tool.
- Fix the wire cover to the inverter with supplied screws.
- Check correct polarity from PV modules and PV input connectors. Connect positive to positive and negative to negative. Screw wires tightly in a clockwise direction. Recommended tool: 4mm blade screwdriver.
4.7 Final Assembly
After connecting all wirings, replace the bottom cover by screwing the two retaining screws.

Image: Detailed diagram of the inverter's back panel showing all connection points: 1. AC Input, 2. AC Output, 3. Communication Port, 4. BMS/RS485 Communication Port, 5. Dry Contact, 6. Battery Input, 7. Power On/Off Switch, 8. PV Input, 9. Input Circuit Breaker, 10. Cooling Fan, 11. Battery Terminal (+), 12. Battery Terminal (-), 13. Solar Panel Input, 14. AC Main/Secondary Output, 15. Output Ground Terminal, 16. CT Signal Port.

Image: Close-up of RS232 and RS485 communication ports. RS485 pin assignments are shown: Pin 1 to 485B, Pin 2 to 485A.
5. Operating
5.1 Power On/Off
Once the unit is properly installed and batteries are connected, press the On/Off switch (located on the bottom of the case) to turn on the unit.
Steps to Start Up:
- Connect the battery (voltage needs to be beyond 23V) or AC (AC needs to confirm suitable input range).
- Mains Power On: Connect to normal AC power, press the switch. The system will automatically turn on. If AC output power priority is set, the panel will display AC mode after a period, indicating successful startup.
- Battery Boot: Connect to battery, press the power-on switch. The system will automatically turn on. If battery mode is set, the panel will display battery mode after a period, indicating successful startup.
Shutdown Steps:
When the system is in battery mode or AC mode output, press the switch again to turn off the system.
5.2 Operation and Display Panel
The front panel features three indicators, four function keys, and an LCD display to show operating status and input/output power information.

Image: Close-up of the inverter's LCD display and control panel. Labels: 1. LCD display, 2. Status indicator, 3. Charging indicator, 4. Fault indicator, 5. ESC button, 6. UP button, 7. DOWN button, 8. ENTER button.
LED Indicators:
| Indicator | Color | Status | Message |
|---|---|---|---|
| AC/INV | Green | Solid On | Output powered by utility (Line mode) |
| Flashing | Output powered by battery or PV (Battery mode) | ||
| CHG | Yellow | Solid On | Battery fully charged |
| Flashing | Battery is charging | ||
| FAULT | Red | Solid On | Fault occurs in the inverter |
| Flashing | Warning condition occurs in the inverter |
Function Keys:
| Key | Description |
|---|---|
| ESC | To exit setting mode |
| UP | To go to previous selection |
| DOWN | To go to next selection |
| ENTER | To confirm selection in setting mode or enter setting mode |
5.3 LCD Setting
To enter setting mode, press and hold the ENTER button for 3 seconds. Use the "UP" or "DOWN" buttons to select setting programs. Press "ENTER" to confirm a selection or "ESC" to exit.
Setting Programs (Examples):
- Program 00: Exit Setting Mode
- Program 01: Output Source Priority Selection (e.g., Solar first, Solar and Utility, Solar only, Solar residual, etc.)
5.4 Operating Mode Description
The inverter operates in various modes depending on power availability and settings:
Standby Mode:
The inverter is not yet turned on, but can charge the battery without AC output. It can also enter a "Power Swing Mode" where output is off if the connected load is very low.
Line Mode:
When utility power is available, the inverter can charge the battery, power loads, and even feed excess solar energy back to the grid, depending on configuration.
6. Maintenance
To ensure optimal performance and longevity of your inverter, regular maintenance is recommended:
- Keep the inverter's ventilation openings clear of dust and debris to prevent overheating.
- Periodically check all wiring connections for tightness and signs of corrosion.
- Ensure the battery terminals are clean and free from corrosion.
- Inspect the unit for any visible damage or unusual noises.
- If the unit is installed in a dusty environment, consider occasional cleaning of the exterior with a soft, dry cloth.
7. Troubleshooting
This section provides guidance for common issues. If problems persist, contact customer support.
7.1 Trouble Removal
| Problem | LCD/LED/Buzzer | Explanation/Possible Cause | What to Do |
|---|---|---|---|
| Unit shuts down automatically during startup | LCD/LEDs and buzzer active for 3s, then off | Battery voltage too low (<1.91V/Cell) | 1. Re-charge battery. 2. Replace battery. |
| No response after power on | No indication | 1. Battery voltage too low (<1.4V/Cell). 2. Internal fuse tripped. | 1. Contact repair center for fuse replacement. 2. Re-charge battery. |
| Input voltage 0 on LCD, green LED flashing | Input protector tripped | 3. Replace battery. Check AC breaker and wiring. | |
| Mains exist but unit works in battery mode | Green LED flashing | Insufficient quality of AC power | 1. Check AC wires (too thin/long). 2. Check generator/input voltage range setting. |
| Green LED flashing | Set "Solar First" as output priority | Change output source priority to Utility first. | |
| When unit turns on, internal relay switches on/off repeatedly | LCD display and LEDs flashing | Battery disconnected | Check battery wires. |
| Buzzer beeps continuously, red LED on | Fault code 07 | Overload error / PV input voltage too high | Reduce connected load / Reduce PV modules in series. |
| Fault code 05 | Output short circuited | Check wiring, remove abnormal load. | |
| Fault code 02 | Internal converter component over-temperature | Check airflow, ambient temperature. | |
| Fault code 03 | Battery over-charged / voltage too high | Return to repair center / Check battery specs. | |
| Fault code 01 | Fan fault | Replace the fan. | |
| Fault code 06/58 | Output abnormal (Inverter voltage out of range) | 1. Reduce connected load. 2. Return to repair center. | |
| Fault code 08/09/53/57 | Internal components failed | Return to repair center. | |
| Fault code 51 | Over current or surge | Restart unit, if error persists, return to repair center. | |
| Fault code 52 | Bus voltage too low | Restart unit, if error persists, return to repair center. | |
| Fault code 55 | Output voltage unbalanced | Restart unit, if error persists, return to repair center. | |
| Fault code 59 | PV input voltage beyond specification | Reduce number of PV modules in series. |
7.2 Fault and Alarm Descriptions
Faults:
When a fault occurs, the inverter enters fault mode, the red LED light is always on, and the LCD displays a fault code. Refer to the manual's fault reference code table for specific codes and their meanings.
Alarms:
When an alarm occurs, the red LED flashes, and the LCD displays an alarm code. The inverter does not enter failure mode during an alarm. Refer to the manual's alarm indicator table for specific codes, audible alarms, and flashing icons.
Code Reference:
Related information codes may be displayed on the LCD screen. Consult the manual's code reference section for detailed explanations of these codes.
8. Specifications
Detailed technical specifications for the DATOUBOSS 48V 5500W Solar Hybrid Inverter.

Image: Close-up of the product specification label on the inverter, detailing model, power, voltage, temperature range, and other electrical parameters.
| Category | Parameter | Value (DT4855U) |
|---|---|---|
| Input | Input Sources | L+N+PE |
| Rated Input Voltage | 110/120VAC | |
| Voltage Range | 65-145VAC±3V | |
| Frequency | 50/60Hz±0.1% | |
| Output | Rated Power (Battery Invert) | 5500W |
| Rated Power (Photovoltaic Invert) | 5500W | |
| Output Voltage | 110/120VAC±5% | |
| Output Frequency | 50/60Hz±0.1% | |
| Grid-Connected Operation | Waveform | Pure Sine Wave |
| Transfer Time (adjustable) | Computers (UPS Mode) 10ms, Appliance (APL Mode) 20ms | |
| Peak Power | 11000VA | |
| Overload Capacity | Battery mode: 11s@105%~150% Load; 2s@150%~200% Load; 400ms@>200% Load | |
| Nominal Output Current | 50A | |
| Maximum Conversion Efficiency (DC/AC) | 98% | |
| Battery | Battery Voltage | 48Vdc |
| Constant Charging Voltage (Adjustable) | 56.4Vdc | |
| Float Charging Voltage (Adjustable) | 54Vdc | |
| Chargers | PV Charging Mode | MPPT |
| MAX. PV Input Power | 8500W | |
| MPPT Tracking Range | 60-500Vdc | |
| Best Voltage | 360~430Vdc | |
| MAX. PV Input Voltage | 500Vdc | |
| MAX. PV Charging Current | 100A | |
| MAX. AC Charging Current | 40A | |
| Interface | RS232 | Baud Rate 2400 |
| Extend Socket Communication Interface | Lithium Battery BMS Communication Card, Wifi Card, Dry Contact | |
| Environment | Operating Temperature | -10-50°C |
| Humidity | 20%-95% (Non-condensing) | |
| Storage Temperature | -15-60°C | |
| Noise | ≤50db | |
| Dimensions & Weight | Size (L*W*H) / Weight | 49.5cm × 31.2cm × 12.5cm / 11.46kg |
9. User Tips
- Always thoroughly read the entire user manual before attempting installation or operation to ensure proper setup and avoid potential issues.
- Double-check all wiring connections, especially polarity for batteries and PV modules, to prevent damage to the inverter and connected components.
- Ensure your battery bank and PV array specifications (voltage, current) are compatible with the inverter's requirements to optimize performance and prevent overloading.
10. Warranty and Support
The DATOUBOSS 48V 5500W Solar Hybrid Inverter comes with a 3-year warranty from the date of purchase.
For technical support, warranty claims, or if you encounter issues not covered in the troubleshooting section, please contact your authorized DATOUBOSS dealer or the seller directly. Provide your product model number and purchase details for faster service.