Hcalory HBS-3S, HBH-3S

Contents

Hcalory Smart Diesel Heater User Manual

Models: HBS-3S, HBH-3S

Hcalory Smart Diesel Heater models HBS-3S and HBH-3S
Hcalory Smart Diesel Heater (HBS-3S and HBH-3S)

1. Introduction

Please read this manual carefully before use to understand the function and operation requirements of the product.

Diesel heaters are on-board heating devices independent of the automobile engine, featuring their own fuel lines, circuits, combustion heating devices, and control systems. Originally used to preheat car engines and cabs in cold environments to prevent cold start wear, these heaters now have broader applications. They serve as space heating equipment in tents, indoors, and RVs, enhancing comfort for users during living and travel.

Video: Hcalory Diesel Heater Product Overview

1.1 Principles of Operation

Heat Source

Upon starting, the ignition plug heats for 1-3 minutes. The fan then activates to supply air to the combustion chamber, and the diesel pump injects diesel. The atomized diesel mixes with air and ignites upon contact with the high-temperature ignition plug, generating significant heat. High-temperature exhaust gases are discharged through the exhaust outlet.

Heating Process

Heat from the combustion chamber is rapidly transferred to an aluminum heat exchanger and dissipated into the warm air duct via aluminum fins. An external fan circulates air around the heat exchanger, and the heated air is expelled through the warm air outlet.

Control System

The device features an embedded controller. Users can operate the heater via a connected switch panel to monitor status, adjust settings, and schedule operations. Remote control and a dedicated Hcalory mobile application are also available for remote management.

1.2 Internal Key Parts Terminology

Familiarize yourself with the internal components before attempting any repairs.

Diagram of internal components including control box, ignition plug, safety plug, air inlet, air fan, flame retardant impeller, combustion chamber, heating zone, and air outlet.
Figure 1: Internal Components Diagram
  • Control Box: Houses the main electronics.
  • Ignition Plug: Initiates combustion.
  • Safety Plug: Safety mechanism.
  • Air Inlet: Where air enters the system.
  • Air Fan: Circulates air.
  • Flame Retardant Impeller: Part of the fan assembly.
  • Combustion Chamber: Where fuel is burned.
  • Heating Zone: Area where heat is transferred.
  • Air Outlet: Where heated air exits.

2. Safety Instructions (Read Before Use)

Failure to follow these safety warnings and instructions may result in electric shock, fire, or serious injury.

  1. Do not replace important parts of the diesel heater without authorization. For repairs or part replacements, contact customer service for correct product specifications and models. Using incorrect specifications can damage the combustion system.
  2. The heater must not be used in locations where flammable vapors or dust may be present, such as:
    • Fuel depots, carbon depots, timber depots, granaries, and similar locations.
    • Diesel/gas stations. Keep away from fuel tanks, compression tanks, fire extinguishers, clothing, and other flammable items.
  3. Use the machine safely and understand its hazards. Children are not allowed to play with this machine. Cleaning and maintenance must not be carried out unsupervised by children.
  4. Do not approach flammable materials (the exhaust pipe operates at very high temperatures)! During installation, use, maintenance, and disposal, ensure no flammable or explosive materials are near the exhaust pipe. Take care to prevent ignition of flammable materials and fire.
  5. Ensure proper ventilation and keep pipes unobstructed. When installing, using, maintaining, and disposing of this equipment, ensure a ventilated area around it to prevent carbon monoxide poisoning. Position the metal exhaust pipe outdoors to prevent exhaust gases from entering the room.
  6. Do not use the heater in an enclosed or unventilated place.
  7. The heater should be turned off when adding diesel.
  8. Do not cut off the power supply directly! After turning off the heating program, the equipment requires a 3-5 minute extinguishing and cooling process. Do not cut off power directly during normal operation! (Direct power cutoff can cause abnormal shutdown, negatively impacting the next start).
  9. If the fuel system is leaking, contact after-sales personnel for parts and repair guidance.
  10. Place the exhaust port outdoors to prevent exhaust gases from entering the room.
  11. During operation, it is strictly forbidden to cut off the power supply directly to stop the heater.
  12. When installing the pipeline, ensure it is unblocked, not squeezed or blocked.
  13. After overheating protection, the machine stops heating. Do not turn off the power. It can be restarted once it has cooled down naturally and shut down.
  14. Do not disconnect the power supply immediately after turning off the machine. It takes 3-5 minutes for the machine to stop working completely.
  15. The first 3-5 minutes after turning on is the preheating and ignition stage, during which the ignition plug, oil pump, and fan operate according to the preset program. Hot air will blow out from the warm air duct after a few minutes; please be patient.
  16. When starting the heater, the ignition plug requires a relatively large current to heat. An adapter with a voltage of 12V and a current of 12A or greater is needed. After successful ignition, the equipment only needs 1-4A to operate continuously.

Important Note: The ignition point of cotton and sponge is 150°C, paper is 130°C, cloth is 270°C, and diesel oil is 220°C. The hot air outlet can reach over 150°C, and the exhaust pipe outlet can exceed 270°C. Ensure proper clearance from flammable materials.

3. Setup and Installation

3.1 Parts List Confirmation

Before installation, please ensure all parts are present and undamaged. The compact design simplifies installation, primarily requiring connection of the exhaust pipe and power.

Image showing all included parts: Host, power adapter, 12/24V DC wire harness, exhaust silencer, exhaust pipe, intake pipe, air outlet pipe, air filter, vents, manual, fixture accessories set, LCD switch, remote control, controller extension cord, exhaust heat wrap, 90° welded elbow pipe.
Figure 2: Included Parts
  • 1 × Air Diesel Heater (Host)
  • 1 × ACDC Power Adapter
  • 1 × 12/24V DC Wire Harness
  • 1 × Exhaust Silencer
  • 1 × Exhaust Pipe
  • 1 × Intake Pipe
  • 1 × Air Outlet Pipe
  • 1 × Air Filter
  • 1 × Vents
  • 1 × User Manual (PDF)
  • 1 × Fixture Accessories Set
  • 1 × LCD Switch
  • 1 × Remote Control
  • 1 × Controller Extension Cord
  • 1 × Exhaust Heat Wrap
  • 1 × 90° Welded Elbow Pipe

3.2 Installation Diagram

The installation process is straightforward. Connect the exhaust pipe and power adapter/DC wire harness. Ensure the exhaust pipe extends outdoors to expel combustion gases safely.

Installation diagram showing the heater unit connected to an exhaust pipe with a silencer, an intake pipe, and an air outlet pipe. Power connections are also shown.
Figure 3: Installation Diagram

Caution: The discharged exhaust gas can reach temperatures as high as 400°C. Keep it away from pets and children, and ensure sufficient clearance from the ground to prevent damage to flooring or lawn.

4. Operating Instructions

4.1 Control Panel Overview

The LCD control panel allows direct interaction with the heater. Below is a diagram of the panel and a table explaining the icons.

LCD Control Panel showing various icons and display areas for temperature, voltage, altitude, and operational status.
Figure 4: LCD Control Panel
IconMeaning
FanFan operation
Sensor failureIndicates a sensor malfunction
Power failureIndicates a power supply issue
Ignition plugIgnition plug status
Oil pumpOil pump status
Bluetooth symbolBluetooth connectivity status
High altitude stateHigh altitude mode active
Timed alarm clockTimer function active
High temperature alarmOverheating warning
Fault promptGeneral fault indication
Automatic start/stopAuto start/stop function active
Ventilation stateVentilation mode active
Manual modeManual heating mode active
Constant temperature modeConstant temperature mode active

4.2 Basic Operations

Power On/Off

  • Start Up: In shutdown state, long press the power key (usually the "on/off" button) for 2 seconds to start the device.
  • Shutdown: In the on state, long press the power key for 2 seconds. The device will enter a shutdown cooling process and display "OFF". Wait until the machine displays the shutdown status before disconnecting power. Forcing power off prematurely can damage components.

Heating Modes

  • Manual Mode: Offers 10 gears (H1-HH10), with HH10 being maximum power. Use the "add" or "reduce" buttons to adjust gears.
  • Constant Temperature Mode: Press "add" or "reduce" to set the desired temperature (0-40°C). Long press the "set" button for 2 seconds to switch between manual and constant temperature modes.
  • Automatic Start/Stop: When in constant temperature mode, short-press the "on/off" key to enable/disable auto start/stop. The icon (A) indicates activation. Default turn-on is -2°C, turn-off is +3°C (e.g., set to 24°C, shuts off at 27°C, turns on at 22°C).

Ventilation Operation

  • In shutdown state, hold down the "set" key for 2 seconds to enter ventilation mode.
  • Use "add" or "reduce" buttons to adjust fan speed.
  • Long press the "set" or "on/off" key for 2 seconds to exit ventilation mode.

Display Data & Settings

  • Switch Display Data: In the on state, short press the "OK" key to cycle through display data: housing temperature -> working voltage -> ambient temperature -> current gear (or current set temperature).
  • Switch Temperature Units: Hold down the "on/off" and "add" keys simultaneously for 2 seconds to switch between °C/°F.
  • Manual Oiling: In shutdown state, press "add" and "reduce" keys simultaneously for 2 seconds to manually control the oil pump. Release to stop. Use with caution.
  • Altitude Enabling: Hold "set" and "OK" keys simultaneously for 2 seconds to activate plateau mode (icon A appears). This adjusts the air-fuel ratio for high altitudes (1000M-5000M). Repeat to disable.
  • Timed On/Off: Hold "OK" and "reduce" keys simultaneously for 2 seconds to enter timer settings. "CLOS" indicates shutdown time, "OPEN" indicates startup time. Use "add/reduce" to adjust time, "on/off" to switch digits, "OK" to save.
  • Clock Synchronization: Long press "OK" for 2 seconds to enter clock adjustment. Use "add/reduce" for time, "on/off" to switch digits, "OK" to confirm.
  • Remote Control Pairing: In shutdown state, hold "on/off" and "reduce" keys simultaneously for 2 seconds to display "HFA1". Use "add/reduce" to select remote ID (1-4). Press any button on the remote to pair. Press "OK" to exit. (Frequency band 433MHZ, 24-bit code).
  • Screen Brightness: In on state, long press "add" and "reduce" keys simultaneously for 2 seconds. "AIRHEATER" icon flashes. Use "add/reduce" to adjust brightness. Repeat to confirm.
  • Bluetooth Password: Press "OK" and "add" simultaneously to view the 4-digit Bluetooth connection password (initial: "0000").
  • Bluetooth Password Initialization: In shutdown state, press "OK" and "on/off" simultaneously for 2 seconds. Enter "3333" using "add/reduce" and "on/off" to confirm with "OK".
  • Oil Pump Frequency Adjustment: In shutdown state, press "OK" and "set" simultaneously for 2 seconds. Enter "3638". Adjust frequency using "add/reduce", switch gears with "on/off", confirm with "OK". Use with caution.
  • Oil Pump Frequency Initialization: In shutdown state, press "OK" and "on/off" simultaneously for 2 seconds. Enter "6666".

4.3 App Operation

If your heater has Bluetooth, you can control it via the Hcalory app. Download the app by scanning the QR codes below or from your app store.

QR code for Android app download
For Android
QR code for iOS app download
For iOS

Upon first launch, click the "+" sign to add a device. Ensure Bluetooth is enabled and precise location information is authorized for device discovery.

App Control Modes

  • Start Heating: Initiate normal heating mode. Choose between temperature mode (intelligent control based on target temp) or gear mode (fixed gear, suitable for open areas).
  • Fan Mode: Fan operates independently without combustion, useful for ventilation.
  • Plateau Mode: Activates high-altitude operation, adjusting air-fuel ratio for stable combustion at 2000-5000 meters. Not recommended for prolonged use above 4000 meters without spare parts.
  • Scheduled Timing: Set multiple timers for on/off functions. The heater must remain powered for timers to execute.
  • One-Click Carbon Deposit Removal: Initiates a 20-minute self-cleaning cycle to remove carbon deposits. Recommended every 1-2 weeks, especially at high altitudes or with prolonged low-power use.

5. Maintenance

5.1 One-Touch Carbon Clean

Long-term operation in low-oxygen environments can lead to carbon deposits in the combustion chamber, reducing efficiency, causing ignition failures, black smoke, high fuel consumption, or component damage.

Operation: In standby mode, press and hold the "set" and "reduce" keys simultaneously for 2 seconds until the screen displays "CLEA" and the Max icon flashes. A 20-minute self-cleaning cycle will start and stop automatically.

Recommendation: Perform carbon cleaning once every 1-2 weeks if using at high altitudes (>1,000m), running at low gears for extended periods, or if symptoms of carbon buildup occur. To cancel mid-cycle, press and hold the power button to turn off.

Diagram illustrating the built-in maintenance mode for one-touch carbon cleaning, showing carbon buildup and the cleaning process.
Figure 5: Built-In Maintenance Mode

6. Troubleshooting (Fault List)

The digital display shows fault codes (e.g., "E-21") and corresponding icons. Refer to the table below for fault meanings and disposition methods.

Fault CodeFailure CauseMethod of Disposition
E021The power supply voltage is too low1) Check whether the battery connection wire is damaged and whether the plug is secure. 2) Check whether the fuse is aging.
E022The power supply voltage is too highCheck the battery output voltage range.
E023Abnormal power supply voltageCheck the battery output voltage range.
E031The ignition plug is open1) Check whether the ignition plug connection wire and plug are loose or broken. 2) Check whether the ignition plug connection plug is loose. 3) Give the ignition plug a separate power connection to check whether it is damaged.
E032The ignition plug is short circuit1) Check whether the ignition plug connection wire is short circuit. 2) Ignition plug is damaged or the motherboard reads wrong.
E041The oil pump is open1) Check whether the connecting wires and connectors of the oil pump are damaged, loose or broken. 2) Check whether the oil pump is damaged.
E042Oil pump short circuit1) Check whether the connection line of the oil pump is short circuit. 2) Check whether the oil pump is blocked and damaged.
E05High temperature alarm (case > 230°C)1) Check whether the cold air intake is blocked. 2) Check whether the hot air outlet pipe is bent or blocked. 3) Check whether the fan is running normally. 4) Check whether the sensor is damaged.
E061Motor open circuit1) Check whether the motor connection wire is broken. 2) Check whether the motor connection wire plug is loose. 3) Connect the motor to the power supply separately and check whether it rotates.
E062Motor short circuit1) Check whether the connecting wire of the motor is short circuit. 2) Motor damage or motherboard read error.
E063Fan speed is abnormal1) Check whether the impeller is stuck. 2) The gap between the magnet on the wind wheel and the Hall sensor on the controller is too large.
E07The master board communicates abnormally with the remote control switchboard1) Check whether the connection port of the remote control switch is loose. 2) Check whether the connection line (blue) of the remote control switch is broken.
E08Flameout1) Check for oil shortage, low temperature solidification of oil, oil line blockage, bent oil pipe, too many steam drums in the oil pipe, and oil pump jam. 2) Check whether the oxygen intake and exhaust air duct is smooth. 3) Check whether the housing temperature sensor is in full contact with the housing and whether the pressure spring is strong. 4) Check whether the sensor is damaged.
E091The temperature sensor is open1) Check whether the temperature sensor connection wire and plug are damaged or loose. 2) Check whether the sensor is damaged.
E092The temperature sensor is short circuit1) Check whether the temperature sensor connection line is short circuit. 2) Check whether the sensor is damaged.
E10The startup was unsuccessful1) The housing temperature is too high, and the housing cannot be cooled after 3 minutes of starting. 2) There is a lot of white smoke at the exhaust port. 2.1) Check whether the filter screen next to the ignition plug is clean, and clean or replace it if not clean. 2.2) Check whether the oil pump is spraying fuel effectively. 2.3) Check whether the ignition plug is aging. 3) There is a small amount of white smoke or no smoke in the waste gas. 3.1) Check whether the oil is missing, the oil line is frozen or blocked. 3.2) Check whether the oil pump is stuck or damaged and unable to pump oil. 3.3) Check whether the combustion intake and exhaust channels are smooth. 3.4) Check whether the ignition plug is damaged. 3.5) Whether the gap of the inner wind wheel is too large. 4) Ignition is normal but still reports ignition failure fault. Check whether the housing temperature sensor is in full contact with the housing and whether the pressure spring is strong. Whether the sensor is normal.

7. Specifications

FeatureDetail
Brand NameHcalory
ModelHBS-3S, HBH-3S
Peak Power8KW
Diesel Consumption0.12 L/h ~ 0.51 L/h
Voltage12V DC / 24V DC / 220~240V AC
MaterialMetal and Plastic
Built-in Fuel Tank Capacity (HBS-3S)3.5L
Built-in Fuel Tank Capacity (HBH-3S)5L
Fuel TypeDiesel
Product Packaging Length48 cm
Product Packaging Width29 cm
Product Packaging Height41 cm
Product Packaging Weight10.0 kg
External Testing CertificationCE, RoHS, FCC
Operating Temperature-40℃ ~ 40℃ (40℉ ~ 104℉)
Auto Start / StopSupported
Bluetooth APP ControlSupported
Remote ControlSupported
LCD Panel ControlSupported
Automatic Altitude Adaptation Mode1000M ~ 5000M
Heating Range20-25㎡
Noise Level (Quiet Fuel Pump)45.2 dBA

8. User Tips

  • For optimal performance and longevity, regularly perform the one-touch carbon cleaning cycle, especially after extended use at low power or high altitudes.
  • When using the heater in constant temperature mode, ensure the area is well-insulated for the most stable and efficient heating experience.
  • If operating in high-altitude environments, remember to activate the "Plateau Mode" to ensure stable combustion and prevent smoke.
  • Utilize the Bluetooth app for convenient remote control, timer scheduling, and monitoring of the heater's status.
  • Always ensure the exhaust pipe is properly routed outdoors and clear of any obstructions to prevent exhaust gas buildup and maintain safety.
  • For cold starts, be patient during the initial 3-5 minute preheating and ignition phase. The heater is designed for reliable operation even in extreme cold.

9. Warranty and Support

Thank you for your support and trust in Hcalory products. Parking heater structures can be complex, and you may encounter unexpected situations during use in various outdoor or indoor environments. If you experience difficulties that you cannot resolve, please contact us for guidance on adjustments or repairs.

For after-sales technical support or any questions about Hcalory products, you can send an email to hcalory@hcalory.com or contact our after-sales personnel through the sales platform where you purchased the product. We will provide you with detailed instructions or operational videos.

The company shall not be responsible for any loss or liability caused by failure to install and use the product according to the provided instructions.

10. FCC Statement

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Note:

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.