OUKITEL EP2500E

Contents

OUKITEL EP2500 Balcony Power Station User Manual

All-in-One Balcony Solar Storage System

1. Safety Precautions

When using this product, basic safety precautions should be followed:

  • Read all instructions before using this product.
  • If this product is used near children, continuous supervision is required to reduce risks.
  • Using accessories not recommended or sold by the professional manufacturer may cause a risk of electric shock.
  • Turn off the product when not in use.
  • Do not disassemble the product, as this may lead to unforeseen risks such as fire, explosion, or electric shock.
  • If the cable, plug, or output cord is damaged, do not use the product to avoid electric shock.
  • Please charge the product in a well-ventilated environment.
  • The product should be placed in a ventilated and dry environment to avoid electric shock caused by rain or moisture.
  • Do not expose the product to fire sources or high-temperature environments (such as direct sunlight or inside a hot vehicle), as this may result in fire or explosion.

Warning Symbols

SymbolMeaning
Danger symbol DANGERHigh voltage inside. Do not open. Risk of electric shock.
Warning symbol WARNINGNever touch the enclosure of an operating battery. Disposal according to local regulations!
Caution symbol CAUTIONKeep the product stable during handling and use. Avoid tilting to prevent danger.
Caution symbol with text CAUTIONRead instructions carefully before performing any operation on the battery.
Do not touch heat sink symbolDo Not Touch Heat Sink During Operation.
Li-ion battery symbol Li-ionThis symbol indicates that the product contains a lithium-ion (Li-ion) battery and should be properly handled or recycled in accordance with relevant regulations.
Waste electrical and electronic equipment symbolThis symbol indicates that this product shall not be disposed of as household waste and should be taken to a designated recycling point for recycling or disposal. Proper recycling and disposal help protect the environment. For more information on the disposal and recycling of this product, please contact your local government, waste disposal authority, or the product retailer.
Battery disposal symbolBatteries and accumulators must not be disposed of with household waste. According to legal requirements, consumers are required to take all batteries and accumulators to designated collection points for disposal, regardless of whether they contain hazardous substances.

2. Device Overview

The OUKITEL EP2500E integrates a bidirectional inverter and a high-reliability battery system into one unit. It is suitable for outdoor environments and various residential scenarios such as garages, balconies, courtyards, and patios, providing users with a green energy lifestyle.

Key Features:

  • Bidirectional AC Grid Connection: Supplies power to the home and draws electricity from the household grid. Manages energy flow for self-consumption and can be quickly charged in custom mode.
  • PV Input: Supports a maximum solar input power of 4000W via four independent MPPT trackers, each supporting up to 1000W PV input. Connects to common rigid or flexible solar panels via standard MC4 connectors or EP2500E portable solar panels with an adapter cable.
  • Microinverter: Equipped with an AC socket for grid-connected (up to 2500W) and off-grid (up to 2500W) modes. Integrates with existing balcony PV systems; power output prioritizes home use, with excess stored in the battery.
  • Stackable Expansion: Supports stacking up to seven EP2000 expansion batteries, scaling storage from 2048Wh to 16384Wh.
  • Remote / Local Control: Supports both remote and local control. When connected to Wi-Fi, monitor operating status in real-time via the app.
  • Operating Modes: Supports grid-priority mode and backup power mode.
  • Standby State: Screen turns off after 30 minutes, light strip enters breathing-light standby mode, other functions remain normal.

Components:

Front and side view of EP2500E with labels

Front View: LCD, Power button, Status LED bar.
Right View: RS485/CAN, Release Valve, AC I/O Socket (grid-connected), AC Output Interface (230V~50Hz, 2500W Max), Ground Terminal.

Right and bottom view of EP2500E with labels

Right View: WLAN antenna, DC Input Interface (PV1/2/3/4: 12-60V, 28A Max, 1000W each, 4*1000W total).
Bottom View: Battery expansion interface (51.2V, 70A Max).

NOTE: Under no circumstances touch these AC and DC interfaces or their connecting parts, otherwise there is a risk of electric shock.

3. Setup

3.1. Packaging List

Ensure all items are present in the box:

EP2500E unit

1. EP2500E Unit

AC power cord

2. AC Power Cord

Solar cable removal tool

3. Solar Cable Removal Tool

Screws and expansion screws

4. Screws *5, Expansion Screws *3

Locking fixings

5. Locking Fixings *3

User Manual and Warranty Card

6. User Manual, Warranty Card

3.2. Pre-Installation

To install and configure the complete system for home use, follow these general procedures:

  1. Prepare the installation location.
  2. Install the solar panels (refer to the user manual of purchased solar panels).
  3. (Optional) Stack expansion batteries.
  4. Connect to the grid.
  5. Connect the solar panels.
  6. Connect AC loads or to an existing microinverter.
  7. Turn on the EP2500E.
  8. Configure the EP2500E via the App.

Installation Site Preparation

Install the device on a dry, well-ventilated, stable, and level surface. The floor slope must not exceed 5°.

For long-term home use, ensure the device is kept away from fire sources, out of direct sunlight, and protected from rain or snow accumulation.

  • Place the device out of reach of children.
  • To ensure optimal operation and extend service life, the ambient temperature must not exceed 55°C and relative humidity must not exceed 95%.
  • Do not use this device at altitudes above 2000m.
  • Do not place the device near flammable materials.
  • Do not place objects on top of the device or cover it.
  • Do not install the inverter near a TV antenna, other antennas, or antenna cables.

Installation Spacing

Sufficient space should be reserved to ensure good heat dissipation of the device. Maintain at least 300mm clearance on the sides and 20mm on top.

Diagram showing recommended installation spacing for heat dissipation

Recommended clearances for proper ventilation.

Network Connection

To fully utilize the smart functions of the device, select a location with an internet connection so that the device can be connected to the EP2500E App.

  • If the home WLAN signal is weak or unavailable, it is recommended to install a Wi-Fi repeater or signal extender to boost the signal.
  • Ensure the antenna is not obstructed so that the device can receive a stable signal.

3.3. Stacking Installation (Battery System)

Up to 7 EP2000 expansion batteries can be stacked below the EP2500E to meet user demands for higher energy storage capacity. If you have purchased the EP2000 battery separately, read this section carefully to ensure correct installation and proper operation with the EP2500E.

NOTE: During installation, ensure the device is turned off.

  1. Remove the dust cap and bottom protective cover: Carefully remove the top and bottom connector covers from the EP2500E and expansion batteries. Keep these covers for future use if the device is stored separately.
  2. Align and Connect the Battery Packs in Sequence: Align the battery expansion connection ports and stack the expansion batteries with the EP2500E in sequence. Ensure the bottom protective cover of the lowest expansion battery is installed in place.
  3. Secure the Main Unit and Battery Pack with Curved Fixing Plates: Use the provided screws and curved fixing plates to secure the main unit to the top battery pack.
  4. Attach the Wall Mounting Pads: If wall mounting, attach the wall mounting pads to the sides of the stacked units.
  5. Secure the Battery Pack with Flat Fixing Plates: Use the provided screws and flat fixing plates to secure the battery packs to each other.
  6. Install the anti-tip bracket on the wall: Install the wall mounting brackets on both sides of the expansion batteries and secure them to the wall to prevent the device from tipping over.
  7. Secure EP2500E and expansion batteries: Use the interlocking fasteners to connect and secure EP2500E with the adjacent expansion batteries.

Video: EP2500 Installation & App Setup Guide. This video demonstrates the physical stacking of battery units and initial app setup.

4. Wiring

NOTE: During wiring, ensure the device is turned off.

4.1. Connecting to the Grid

The EP2500E supports a long-term connection to the building's grid access point.

  1. Use the AC power cord included in the package to connect the grid-connected interface to a wall outlet.
  2. If higher output power is required, contact a certified electrician to inspect your electrical system to ensure compliance with local and national safety standards.
  3. After confirmation by the electrician, you can apply to increase the device's output power to 2500W via the EP2500E App.
Diagram showing grid connection

Diagram: Plug & Play Simplicity - Grid connection.

NOTE: When using EP2500E, ensure the device is properly grounded. Also confirm that the grounding of your home electrical system complies with regulations.

Disconnecting AC Power Cord

To remove the AC power cord, follow these steps:

  1. Power off the device.
  2. Rotate the connector body to the left, then pull out the plug.
  3. Reattach the waterproof protective cap to the plug.

4.2. Connecting Solar Panels

The EP2500E is equipped with 4 MPPT trackers, each supporting up to 1000W PV input, with a total PV input power of up to 4000W. Each MPPT supports up to 60V / 28A solar input. Solar panels can be connected in series, in parallel, or directly to the device.

NOTE: When the device receives power from the solar panels, it will automatically start up and begin operation.

If you purchased OUKITEL EP2500E rigid or flexible solar panels, you can connect them directly to the EP2500E, or first connect the solar panels in parallel before connecting to the device. Refer to the wiring diagrams for detailed connection methods.

Diagram showing series and parallel solar panel connections

Diagram: Series and Parallel Solar Panel Connection options.

NOTE:

  • When connecting multiple solar panels to one PV input, ensure that each string uses solar panels of the same model and quantity to avoid device damage or charging abnormalities caused by string voltage mismatch.
  • Do not mix the positive and negative terminals of PV1, PV2, PV3, and PV4.

To disconnect an MC4 connector from EP2500E, use the supplied solar cable removal tool.

4.3. Connecting AC Loads

Plug electrical devices directly into the AC socket.

NOTE: To avoid risk of electric shock, do not use this socket in rainy weather.

Backup Power System

This socket supports up to 2500W AC output in grid-connected operation (bypass mode) and up to 2500W output in off-grid operation (with at least one expansion battery connected). You can use the AC socket to power devices.

In the event of a sudden power outage, EP2500E can automatically switch to battery power mode within 10ms.

As this function is not a professional UPS (uninterruptible power supply) function, the system does not support 0ms seamless switching.

NOTE:

  • Do not connect devices that require extremely high uninterrupted power supply, such as data servers or workstation computers.
  • Test the compatibility of connected devices multiple times before use.
  • To avoid triggering overload protection, connect only one device at a time.
  • Failure to comply with the above instructions may result in device damage or data loss, for which OUKITEL assumes no responsibility.

5. Operating

5.1. Power On

If the device is not connected to any power source, press and hold the POWER button for more than 3 seconds; the device will start when the indicator lights up.

The device will also automatically start when it receives power from solar panels or the utility grid.

Diagram showing power on process

Diagram: Power On via button or automatic startup from solar/grid.

After startup, the EP2500E operates in grid-priority mode by default (when first power-on).

5.2. Power Off

Press and hold the POWER button for more than 3 seconds until the display goes off and the indicator flashes three times; the device then powers off.

During operation, if there is no operation for 30 minutes, the display will enter screen-off (sleep) mode and the indicator will enter breathing light mode.

NOTE: If the device is not to be used for an extended period, turn it off and disconnect the AC cable and PV cable.

5.3. Button Control

ButtonOperationFunction
PowerPress and hold for 3 secondsTurn system on/off
Single click (when the device is on)Turn LCD on/off
Press it 4 times consecutively to enter Wi-Fi configurationWi-Fi icon flashes

5.4. LED Indicators

LEDStatusProduct Status
PowerOffPress Power button to turn off the screen and the LED
Normally onDevice enters sleep mode after 30 min, screen off, LED breathes

5.5. LCD Display

The LCD display provides real-time information about the system's status. It automatically turns off after no operation. Press the Power button to turn on the screen. After 30 minutes of inactivity, the device enters sleep mode, and the display turns off.

No.Icon/IndicatorMeaning
1On GridGrid-connected status: System connected to mains
2ON GRIDGrid status: Charging/discharging between system and grid
3OFF GRIDGrid status: No charging/discharging between system and grid
4PVSolar input status: Displaying external solar input to PV
5×8Parallel operation status: Number indicates how many battery packs are connected
6HOMESystem discharge status: System is powering home appliances
7Battery statusIcon on during both battery charging and discharging
8High temperature iconIcon on: indicates high battery temperature
9WIFI 1Normally on: WLAN connected. Flashing: Waiting for WLAN connection
10WIFI 2Normally on: WLAN connected. Flashing: Waiting for WLAN connection
11ALMError Messages: Device detects a system fault. See "Troubleshooting" section for details.
12Low temperature iconIcon on: indicates low battery temperature
13Output power (W)Displays output power (unit: W)
14Battery percentage (%)Displays current remaining battery percentage
15Input power (W)Displays input power (unit: W)
16AC OutputIndicates that the device is supplying power externally from the off-grid port

6. APP Control

The OUKITEL EP2500 can be controlled and monitored via a mobile application. This allows for real-time energy data viewing and customization of settings.

6.1. App Installation

Search for "Smart Life - Smart Home" in the Google Play Store or Apple App Store to download and install the App. After installation, you can register and log in.

Download on the App StoreGet it on Google Play

Alternatively, scan the QR code below to download and install the App:

QR code for app download

Scan to download the Smart Life App.

6.2. Connecting to the App

  1. Press the Power Button more than 4 times quickly on the EP2500E. When the light flashes, the device has entered pairing mode.
  2. Open the Smart Life App on your smartphone.
  3. Click the "+" icon in the upper right corner to add devices.
  4. The app should detect "Balcony Energy Storage". Click "Add" to pair.
  5. Select your Wi-Fi Network from the list and enter the password.
  6. Wait for connection. Upon successful connection, the indicator light on the EP2500E will flash slowly.
  7. Once connected, you can view real-time energy data by tapping "Storage" and customize settings by tapping "Function Name".

Video: EP2500 Installation & App Setup Guide. This video demonstrates the physical stacking of battery units and initial app setup.

7. Maintenance

NOTE: Before performing maintenance, disconnect the device from external power sources and turn off the device.

7.1. Heat Dissipation Inspection

If the device frequently reduces grid-connected output power due to excessive temperature, improve the heat dissipation conditions of the device.

  • Check whether objects are blocking the front or rear of the device.
  • Clean the heat sink of the device.

7.2. Inspection of Cables and Connectors

Inspect connectors and cables for externally visible damage once a year. If obvious damage is found on connectors or cables, replace them promptly.

7.3. Periodic Full Charging

If the battery has not been fully charged for a long time, it is recommended to perform a complete charge once a month to extend battery service life.

7.4. Storage

Store the device in a dry, clean, and well-ventilated environment. Storage temperature and humidity requirements are as follows:

  • 1 month: -20°C to 45°C (0-65% RH)
  • 3 months: 0°C to 45°C (0-65% RH)
  • 12 months: 0°C to 45°C (0-65% RH)

If the device needs to be stored for 3 to 6 months, perform the following routine maintenance steps:

  1. Open the EP2500E App and enable Custom Mode. Fully charge the battery, then let it stand for 30 minutes.
  2. Set Grid-Priority mode, set the discharge power to 800W, and discharge the battery until the battery SOC reaches 60%.
  3. Turn off the device, disconnect all cables, and store the device under the recommended environmental conditions.

8. Troubleshooting

8.1. Error Messages

If the following error codes are displayed, take the corresponding corrective actions. If the problem persists, contact the manufacturer's customer service personnel.

Error CodeCauseSolutionHardware Related
F001BMS communication lostCheck if communication cable is looseMain control error
F002Microinverter communication lostCheck if communication cable is loose
F003Wi-Fi communication lostCheck if antenna is disconnected
F004Meter communication lostCheck if antenna is disconnected
F101Low discharge temperatureFault clears when temperature returns to recovery pointBMS protection info
F102Low charging temperatureFault clears when temperature returns to recovery point
F103High discharge temperatureFault clears when temperature returns to recovery point
F104High charging temperatureFault clears when temperature returns to recovery point
F105Cell or module overvoltageCheck if fault clears after restart
F106Cell or module undervoltageCheck if fault clears after restart
F107Discharge overcurrentCheck if fault clears after restart
F108Charging overcurrentCheck if fault clears after restart
F109Battery high voltage faultCheck if fault clears after restart
F110Battery low voltage faultCheck if fault clears after restart
F111System abnormalityCheck if fault clears after restart
FE01Battery overvoltageCheck if fault clears after restartInverter fault
FE02Battery undervoltageCheck if fault clears after restart
FE03Inverter overtemperatureFault clears when temperature returns to recovery point
FE04Abnormal grid voltageFault clears when voltage returns to normal
FE05Abnormal grid frequencyFault clears when frequency returns to normal
FE06Abnormal output voltageCheck if fault clears after restart
FE07Output short circuitFault clears after restart
FE08Output overloadFault clears after restart
FE09Inverter faultCheck if fault clears after restart
FE10PV overvoltageFault clears when voltage returns to normal
F111PV faultCheck if fault clears after restart

8.2. Frequently Asked Questions (FAQ)

The following table lists common problems you may encounter while using this product. For the latest FAQ information, please visit our official website.

ProblemSolution
EP2500E App network connection failed
  • Confirm that the router is a 2.4 GHz network, as the device only supports 2.4 GHz Wi-Fi.
  • Check whether the device has already been paired with another network. If so, cancel the pairing first, then reconnect.
EP2500E App shows the device offline
  • Check whether the home network is abnormal; if so, restart the router.
  • Check whether the home network has internet access.
  • If the home network is normal, but the App still does not display device information, please contact the dealer or the technical support personnel.
Parallel operation fault (failed connection between main unit and battery pack)
  • After parallel connection, the power icon indicates successful communication; after a moment, it indicates successful parallel connection. The device can only be used normally after successful parallel connection.
  • In case of parallel connection failed, verify that the connections are secure and reinstall the main unit and battery pack. Hardware problems are generally unlikely.
Device disconnected from the grid and discharge failed
  • Check the stop-discharge SOC set in the App. When the SOC is below the setting, the device cannot discharge.
  • Check whether the device has a fault such as overload or overtemperature. If a fault exists, the device cannot discharge.
Ground fault indicated after device startupCheck whether the grid-connected interface is properly grounded and verify that the ground connection is in good condition. If grounding is poor, the device may not function correctly.
Low device grid output power
  • Check whether the device is overheating. Overheating causes the system to automatically limit output power.
  • If none of the above conditions exist, contact the dealer or the technical support personnel.
PV voltage exceeding allowable input range
  • Check whether the actual output voltage of the solar panels exceeds the device's PV input range.
  • If the voltage is within the allowable range but the problem persists, contact the dealer or technical support personnel.
Expansion battery fault and SOC below 5%
  • Power off the device.
  • Wait 5 minutes, then restart the device. The system will automatically charge the expansion battery at the minimum power.
  • If the problem persists after restarting, contact the dealer or technical support personnel.

9. Technical Specifications

9.1. General Information

ItemSpecification
ModelEP2500E
Weight27.2 kg
Dimensions490 × 276 × 287 mm
IP RatingIP65
Pollution DegreeIII
Protection LevelI
Overvoltage CategoryII (DC); III (AC)
Inverter TopologyIsolated
Communication ModeWi-Fi

9.2. Battery Information

ItemSpecification
IEC CodeEP2000
Battery Chemical SystemLiFePO4
Rated Energy2048 Wh
Total Capacity40 Ah
Rated Voltage51.2 V d.c.
Voltage Range40-58.4 V d.c.
Charge and Discharge Current58 A/70 A Max.
Service Life4000 Cycles, 90% DOD, ≥70% SOH

9.3. DC Input (PV1/2/3/4)

ItemSpecification
Maximum Input Power1000 W * 4
Maximum Input Voltage60 V d.c.
Maximum Input Current28 A * 4
Voltage Range12-60 V d.c.

9.4. AC Input/Output (Grid-Connected)

ItemSpecification
Maximum AC Input Power2500 W
Maximum AC Input Apparent Power2500 VA
Maximum AC Input Current16 A
Maximum AC Output Power2500 W
Maximum AC Output Apparent Power2500 VA
Maximum AC Output Current16 A
Grid VoltageL+N+PE, 230 Va.c., 50 Hz
Power Factor Range0.8 leading...0.8 lagging
Maximum AC Output Power (bypass)2500 W
Maximum AC Output Current (bypass)16 A

9.5. AC Input/Output (AC Socket)

ItemSpecification
Maximum AC Input Power2500 W ①
Maximum AC Input Apparent Power2500 VA
Maximum AC Input Current16 A
Maximum AC Output Power2500 W ②
Maximum AC Output Apparent Power2500 VA
Maximum AC Output Current16 A
Grid VoltageL+N+PE, 230 Va.c., 50 Hz
Power Factor Range0.8 leading...0.8 lagging
Maximum AC Output Power (bypass)2500 W
Maximum AC Output Current (bypass)16 A

①: When the product is connected to one or more expansion batteries, this socket supports an input power of up to 2500 W. If no expansion battery is connected, the maximum input power of the internal battery through this AC socket is 2500 W.

②: When the product is connected to one or more expansion batteries, this socket can provide an output power of up to 2500 W. If no expansion battery is connected, the maximum output power of the internal battery through this AC socket is 2500 W.

9.6. Environmental Requirements

ItemSpecification
Environmental Temperature-20°C ~ 40°C
Ambient Humidity5% ~ 95% RH

10. User Tips

  • Grounding for Off-Grid Use: When using the inverter off-grid, with or without charging, it is essential to ensure proper grounding. Refer to local electrical codes and regulations for specific grounding requirements to ensure safety and optimal performance.
  • Maximize Solar Savings: Utilize the app's customization features to set optimal charging and discharging times based on your electricity rates and solar generation patterns to maximize savings.
  • Regular Checks: Periodically check all connections and cables for wear and tear, especially if the unit is exposed to outdoor elements.

11. Warranty & Support

For detailed warranty information, please visit the official OUKITEL website:

https://oukitel.com/pages/oukitel-power

If you encounter any issues not covered in this manual or require further assistance, please contact OUKITEL customer support or your product retailer.

© 2023 OUKITEL. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.