1. Safety Precautions
When using this product, basic safety precautions should be followed:
- Read all instructions before using this product.
- If this product is used near children, continuous supervision is required to reduce risks.
- Using accessories not recommended or sold by the professional manufacturer may cause a risk of electric shock.
- Turn off the product when not in use.
- Do not disassemble the product, as this may lead to unforeseen risks such as fire, explosion, or electric shock.
- If the cable, plug, or output cord is damaged, do not use the product to avoid electric shock.
- Please charge the product in a well-ventilated environment.
- The product should be placed in a ventilated and dry environment to avoid electric shock caused by rain or moisture.
- Do not expose the product to fire sources or high-temperature environments (such as direct sunlight or inside a hot vehicle), as this may result in fire or explosion.
Warning Symbols
| Symbol | Meaning |
|---|---|
| High voltage inside. Do not open. Risk of electric shock. | |
| Never touch the enclosure of an operating battery. Disposal according to local regulations! | |
| Keep the product stable during handling and use. Avoid tilting to prevent danger. | |
| Read instructions carefully before performing any operation on the battery. | |
| Do Not Touch Heat Sink During Operation. | |
| This symbol indicates that the product contains a lithium-ion (Li-ion) battery and should be properly handled or recycled in accordance with relevant regulations. | |
| This symbol indicates that this product shall not be disposed of as household waste and should be taken to a designated recycling point for recycling or disposal. Proper recycling and disposal help protect the environment. For more information on the disposal and recycling of this product, please contact your local government, waste disposal authority, or the product retailer. | |
| Batteries and accumulators must not be disposed of with household waste. According to legal requirements, consumers are required to take all batteries and accumulators to designated collection points for disposal, regardless of whether they contain hazardous substances. |
2. Device Overview
The OUKITEL EP2500E integrates a bidirectional inverter and a high-reliability battery system into one unit. It is suitable for outdoor environments and various residential scenarios such as garages, balconies, courtyards, and patios, providing users with a green energy lifestyle.
Key Features:
- Bidirectional AC Grid Connection: Supplies power to the home and draws electricity from the household grid. Manages energy flow for self-consumption and can be quickly charged in custom mode.
- PV Input: Supports a maximum solar input power of 4000W via four independent MPPT trackers, each supporting up to 1000W PV input. Connects to common rigid or flexible solar panels via standard MC4 connectors or EP2500E portable solar panels with an adapter cable.
- Microinverter: Equipped with an AC socket for grid-connected (up to 2500W) and off-grid (up to 2500W) modes. Integrates with existing balcony PV systems; power output prioritizes home use, with excess stored in the battery.
- Stackable Expansion: Supports stacking up to seven EP2000 expansion batteries, scaling storage from 2048Wh to 16384Wh.
- Remote / Local Control: Supports both remote and local control. When connected to Wi-Fi, monitor operating status in real-time via the app.
- Operating Modes: Supports grid-priority mode and backup power mode.
- Standby State: Screen turns off after 30 minutes, light strip enters breathing-light standby mode, other functions remain normal.
Components:

Front View: LCD, Power button, Status LED bar.
Right View: RS485/CAN, Release Valve, AC I/O Socket (grid-connected), AC Output Interface (230V~50Hz, 2500W Max), Ground Terminal.

Right View: WLAN antenna, DC Input Interface (PV1/2/3/4: 12-60V, 28A Max, 1000W each, 4*1000W total).
Bottom View: Battery expansion interface (51.2V, 70A Max).
NOTE: Under no circumstances touch these AC and DC interfaces or their connecting parts, otherwise there is a risk of electric shock.
3. Setup
3.1. Packaging List
Ensure all items are present in the box:

1. EP2500E Unit

2. AC Power Cord

3. Solar Cable Removal Tool

4. Screws *5, Expansion Screws *3

5. Locking Fixings *3

6. User Manual, Warranty Card
3.2. Pre-Installation
To install and configure the complete system for home use, follow these general procedures:
- Prepare the installation location.
- Install the solar panels (refer to the user manual of purchased solar panels).
- (Optional) Stack expansion batteries.
- Connect to the grid.
- Connect the solar panels.
- Connect AC loads or to an existing microinverter.
- Turn on the EP2500E.
- Configure the EP2500E via the App.
Installation Site Preparation
Install the device on a dry, well-ventilated, stable, and level surface. The floor slope must not exceed 5°.
For long-term home use, ensure the device is kept away from fire sources, out of direct sunlight, and protected from rain or snow accumulation.
- Place the device out of reach of children.
- To ensure optimal operation and extend service life, the ambient temperature must not exceed 55°C and relative humidity must not exceed 95%.
- Do not use this device at altitudes above 2000m.
- Do not place the device near flammable materials.
- Do not place objects on top of the device or cover it.
- Do not install the inverter near a TV antenna, other antennas, or antenna cables.
Installation Spacing
Sufficient space should be reserved to ensure good heat dissipation of the device. Maintain at least 300mm clearance on the sides and 20mm on top.

Recommended clearances for proper ventilation.
Network Connection
To fully utilize the smart functions of the device, select a location with an internet connection so that the device can be connected to the EP2500E App.
- If the home WLAN signal is weak or unavailable, it is recommended to install a Wi-Fi repeater or signal extender to boost the signal.
- Ensure the antenna is not obstructed so that the device can receive a stable signal.
3.3. Stacking Installation (Battery System)
Up to 7 EP2000 expansion batteries can be stacked below the EP2500E to meet user demands for higher energy storage capacity. If you have purchased the EP2000 battery separately, read this section carefully to ensure correct installation and proper operation with the EP2500E.
NOTE: During installation, ensure the device is turned off.
- Remove the dust cap and bottom protective cover: Carefully remove the top and bottom connector covers from the EP2500E and expansion batteries. Keep these covers for future use if the device is stored separately.
- Align and Connect the Battery Packs in Sequence: Align the battery expansion connection ports and stack the expansion batteries with the EP2500E in sequence. Ensure the bottom protective cover of the lowest expansion battery is installed in place.
- Secure the Main Unit and Battery Pack with Curved Fixing Plates: Use the provided screws and curved fixing plates to secure the main unit to the top battery pack.
- Attach the Wall Mounting Pads: If wall mounting, attach the wall mounting pads to the sides of the stacked units.
- Secure the Battery Pack with Flat Fixing Plates: Use the provided screws and flat fixing plates to secure the battery packs to each other.
- Install the anti-tip bracket on the wall: Install the wall mounting brackets on both sides of the expansion batteries and secure them to the wall to prevent the device from tipping over.
- Secure EP2500E and expansion batteries: Use the interlocking fasteners to connect and secure EP2500E with the adjacent expansion batteries.
Video: EP2500 Installation & App Setup Guide. This video demonstrates the physical stacking of battery units and initial app setup.
4. Wiring
NOTE: During wiring, ensure the device is turned off.
4.1. Connecting to the Grid
The EP2500E supports a long-term connection to the building's grid access point.
- Use the AC power cord included in the package to connect the grid-connected interface to a wall outlet.
- If higher output power is required, contact a certified electrician to inspect your electrical system to ensure compliance with local and national safety standards.
- After confirmation by the electrician, you can apply to increase the device's output power to 2500W via the EP2500E App.

Diagram: Plug & Play Simplicity - Grid connection.
NOTE: When using EP2500E, ensure the device is properly grounded. Also confirm that the grounding of your home electrical system complies with regulations.
Disconnecting AC Power Cord
To remove the AC power cord, follow these steps:
- Power off the device.
- Rotate the connector body to the left, then pull out the plug.
- Reattach the waterproof protective cap to the plug.
4.2. Connecting Solar Panels
The EP2500E is equipped with 4 MPPT trackers, each supporting up to 1000W PV input, with a total PV input power of up to 4000W. Each MPPT supports up to 60V / 28A solar input. Solar panels can be connected in series, in parallel, or directly to the device.
NOTE: When the device receives power from the solar panels, it will automatically start up and begin operation.
If you purchased OUKITEL EP2500E rigid or flexible solar panels, you can connect them directly to the EP2500E, or first connect the solar panels in parallel before connecting to the device. Refer to the wiring diagrams for detailed connection methods.

Diagram: Series and Parallel Solar Panel Connection options.
NOTE:
- When connecting multiple solar panels to one PV input, ensure that each string uses solar panels of the same model and quantity to avoid device damage or charging abnormalities caused by string voltage mismatch.
- Do not mix the positive and negative terminals of PV1, PV2, PV3, and PV4.
To disconnect an MC4 connector from EP2500E, use the supplied solar cable removal tool.
4.3. Connecting AC Loads
Plug electrical devices directly into the AC socket.
NOTE: To avoid risk of electric shock, do not use this socket in rainy weather.
Backup Power System
This socket supports up to 2500W AC output in grid-connected operation (bypass mode) and up to 2500W output in off-grid operation (with at least one expansion battery connected). You can use the AC socket to power devices.
In the event of a sudden power outage, EP2500E can automatically switch to battery power mode within 10ms.
As this function is not a professional UPS (uninterruptible power supply) function, the system does not support 0ms seamless switching.
NOTE:
- Do not connect devices that require extremely high uninterrupted power supply, such as data servers or workstation computers.
- Test the compatibility of connected devices multiple times before use.
- To avoid triggering overload protection, connect only one device at a time.
- Failure to comply with the above instructions may result in device damage or data loss, for which OUKITEL assumes no responsibility.
5. Operating
5.1. Power On
If the device is not connected to any power source, press and hold the POWER button for more than 3 seconds; the device will start when the indicator lights up.
The device will also automatically start when it receives power from solar panels or the utility grid.

Diagram: Power On via button or automatic startup from solar/grid.
After startup, the EP2500E operates in grid-priority mode by default (when first power-on).
5.2. Power Off
Press and hold the POWER button for more than 3 seconds until the display goes off and the indicator flashes three times; the device then powers off.
During operation, if there is no operation for 30 minutes, the display will enter screen-off (sleep) mode and the indicator will enter breathing light mode.
NOTE: If the device is not to be used for an extended period, turn it off and disconnect the AC cable and PV cable.
5.3. Button Control
| Button | Operation | Function |
|---|---|---|
| Power | Press and hold for 3 seconds | Turn system on/off |
| Single click (when the device is on) | Turn LCD on/off | |
| Press it 4 times consecutively to enter Wi-Fi configuration | Wi-Fi icon flashes |
5.4. LED Indicators
| LED | Status | Product Status |
|---|---|---|
| Power | Off | Press Power button to turn off the screen and the LED |
| Normally on | Device enters sleep mode after 30 min, screen off, LED breathes |
5.5. LCD Display
The LCD display provides real-time information about the system's status. It automatically turns off after no operation. Press the Power button to turn on the screen. After 30 minutes of inactivity, the device enters sleep mode, and the display turns off.
| No. | Icon/Indicator | Meaning |
|---|---|---|
| 1 | On Grid | Grid-connected status: System connected to mains |
| 2 | ON GRID | Grid status: Charging/discharging between system and grid |
| 3 | OFF GRID | Grid status: No charging/discharging between system and grid |
| 4 | PV | Solar input status: Displaying external solar input to PV |
| 5 | ×8 | Parallel operation status: Number indicates how many battery packs are connected |
| 6 | HOME | System discharge status: System is powering home appliances |
| 7 | Battery status | Icon on during both battery charging and discharging |
| 8 | High temperature icon | Icon on: indicates high battery temperature |
| 9 | WIFI 1 | Normally on: WLAN connected. Flashing: Waiting for WLAN connection |
| 10 | WIFI 2 | Normally on: WLAN connected. Flashing: Waiting for WLAN connection |
| 11 | ALM | Error Messages: Device detects a system fault. See "Troubleshooting" section for details. |
| 12 | Low temperature icon | Icon on: indicates low battery temperature |
| 13 | Output power (W) | Displays output power (unit: W) |
| 14 | Battery percentage (%) | Displays current remaining battery percentage |
| 15 | Input power (W) | Displays input power (unit: W) |
| 16 | AC Output | Indicates that the device is supplying power externally from the off-grid port |
6. APP Control
The OUKITEL EP2500 can be controlled and monitored via a mobile application. This allows for real-time energy data viewing and customization of settings.
6.1. App Installation
Search for "Smart Life - Smart Home" in the Google Play Store or Apple App Store to download and install the App. After installation, you can register and log in.
Alternatively, scan the QR code below to download and install the App:

Scan to download the Smart Life App.
6.2. Connecting to the App
- Press the Power Button more than 4 times quickly on the EP2500E. When the light flashes, the device has entered pairing mode.
- Open the Smart Life App on your smartphone.
- Click the "+" icon in the upper right corner to add devices.
- The app should detect "Balcony Energy Storage". Click "Add" to pair.
- Select your Wi-Fi Network from the list and enter the password.
- Wait for connection. Upon successful connection, the indicator light on the EP2500E will flash slowly.
- Once connected, you can view real-time energy data by tapping "Storage" and customize settings by tapping "Function Name".
Video: EP2500 Installation & App Setup Guide. This video demonstrates the physical stacking of battery units and initial app setup.
7. Maintenance
NOTE: Before performing maintenance, disconnect the device from external power sources and turn off the device.
7.1. Heat Dissipation Inspection
If the device frequently reduces grid-connected output power due to excessive temperature, improve the heat dissipation conditions of the device.
- Check whether objects are blocking the front or rear of the device.
- Clean the heat sink of the device.
7.2. Inspection of Cables and Connectors
Inspect connectors and cables for externally visible damage once a year. If obvious damage is found on connectors or cables, replace them promptly.
7.3. Periodic Full Charging
If the battery has not been fully charged for a long time, it is recommended to perform a complete charge once a month to extend battery service life.
7.4. Storage
Store the device in a dry, clean, and well-ventilated environment. Storage temperature and humidity requirements are as follows:
- 1 month: -20°C to 45°C (0-65% RH)
- 3 months: 0°C to 45°C (0-65% RH)
- 12 months: 0°C to 45°C (0-65% RH)
If the device needs to be stored for 3 to 6 months, perform the following routine maintenance steps:
- Open the EP2500E App and enable Custom Mode. Fully charge the battery, then let it stand for 30 minutes.
- Set Grid-Priority mode, set the discharge power to 800W, and discharge the battery until the battery SOC reaches 60%.
- Turn off the device, disconnect all cables, and store the device under the recommended environmental conditions.
8. Troubleshooting
8.1. Error Messages
If the following error codes are displayed, take the corresponding corrective actions. If the problem persists, contact the manufacturer's customer service personnel.
| Error Code | Cause | Solution | Hardware Related |
|---|---|---|---|
| F001 | BMS communication lost | Check if communication cable is loose | Main control error |
| F002 | Microinverter communication lost | Check if communication cable is loose | |
| F003 | Wi-Fi communication lost | Check if antenna is disconnected | |
| F004 | Meter communication lost | Check if antenna is disconnected | |
| F101 | Low discharge temperature | Fault clears when temperature returns to recovery point | BMS protection info |
| F102 | Low charging temperature | Fault clears when temperature returns to recovery point | |
| F103 | High discharge temperature | Fault clears when temperature returns to recovery point | |
| F104 | High charging temperature | Fault clears when temperature returns to recovery point | |
| F105 | Cell or module overvoltage | Check if fault clears after restart | |
| F106 | Cell or module undervoltage | Check if fault clears after restart | |
| F107 | Discharge overcurrent | Check if fault clears after restart | |
| F108 | Charging overcurrent | Check if fault clears after restart | |
| F109 | Battery high voltage fault | Check if fault clears after restart | |
| F110 | Battery low voltage fault | Check if fault clears after restart | |
| F111 | System abnormality | Check if fault clears after restart | |
| FE01 | Battery overvoltage | Check if fault clears after restart | Inverter fault |
| FE02 | Battery undervoltage | Check if fault clears after restart | |
| FE03 | Inverter overtemperature | Fault clears when temperature returns to recovery point | |
| FE04 | Abnormal grid voltage | Fault clears when voltage returns to normal | |
| FE05 | Abnormal grid frequency | Fault clears when frequency returns to normal | |
| FE06 | Abnormal output voltage | Check if fault clears after restart | |
| FE07 | Output short circuit | Fault clears after restart | |
| FE08 | Output overload | Fault clears after restart | |
| FE09 | Inverter fault | Check if fault clears after restart | |
| FE10 | PV overvoltage | Fault clears when voltage returns to normal | |
| F111 | PV fault | Check if fault clears after restart |
8.2. Frequently Asked Questions (FAQ)
The following table lists common problems you may encounter while using this product. For the latest FAQ information, please visit our official website.
| Problem | Solution |
|---|---|
| EP2500E App network connection failed |
|
| EP2500E App shows the device offline |
|
| Parallel operation fault (failed connection between main unit and battery pack) |
|
| Device disconnected from the grid and discharge failed |
|
| Ground fault indicated after device startup | Check whether the grid-connected interface is properly grounded and verify that the ground connection is in good condition. If grounding is poor, the device may not function correctly. |
| Low device grid output power |
|
| PV voltage exceeding allowable input range |
|
| Expansion battery fault and SOC below 5% |
|
9. Technical Specifications
9.1. General Information
| Item | Specification |
|---|---|
| Model | EP2500E |
| Weight | 27.2 kg |
| Dimensions | 490 × 276 × 287 mm |
| IP Rating | IP65 |
| Pollution Degree | III |
| Protection Level | I |
| Overvoltage Category | II (DC); III (AC) |
| Inverter Topology | Isolated |
| Communication Mode | Wi-Fi |
9.2. Battery Information
| Item | Specification |
|---|---|
| IEC Code | EP2000 |
| Battery Chemical System | LiFePO4 |
| Rated Energy | 2048 Wh |
| Total Capacity | 40 Ah |
| Rated Voltage | 51.2 V d.c. |
| Voltage Range | 40-58.4 V d.c. |
| Charge and Discharge Current | 58 A/70 A Max. |
| Service Life | 4000 Cycles, 90% DOD, ≥70% SOH |
9.3. DC Input (PV1/2/3/4)
| Item | Specification |
|---|---|
| Maximum Input Power | 1000 W * 4 |
| Maximum Input Voltage | 60 V d.c. |
| Maximum Input Current | 28 A * 4 |
| Voltage Range | 12-60 V d.c. |
9.4. AC Input/Output (Grid-Connected)
| Item | Specification |
|---|---|
| Maximum AC Input Power | 2500 W |
| Maximum AC Input Apparent Power | 2500 VA |
| Maximum AC Input Current | 16 A |
| Maximum AC Output Power | 2500 W |
| Maximum AC Output Apparent Power | 2500 VA |
| Maximum AC Output Current | 16 A |
| Grid Voltage | L+N+PE, 230 Va.c., 50 Hz |
| Power Factor Range | 0.8 leading...0.8 lagging |
| Maximum AC Output Power (bypass) | 2500 W |
| Maximum AC Output Current (bypass) | 16 A |
9.5. AC Input/Output (AC Socket)
| Item | Specification |
|---|---|
| Maximum AC Input Power | 2500 W ① |
| Maximum AC Input Apparent Power | 2500 VA |
| Maximum AC Input Current | 16 A |
| Maximum AC Output Power | 2500 W ② |
| Maximum AC Output Apparent Power | 2500 VA |
| Maximum AC Output Current | 16 A |
| Grid Voltage | L+N+PE, 230 Va.c., 50 Hz |
| Power Factor Range | 0.8 leading...0.8 lagging |
| Maximum AC Output Power (bypass) | 2500 W |
| Maximum AC Output Current (bypass) | 16 A |
①: When the product is connected to one or more expansion batteries, this socket supports an input power of up to 2500 W. If no expansion battery is connected, the maximum input power of the internal battery through this AC socket is 2500 W.
②: When the product is connected to one or more expansion batteries, this socket can provide an output power of up to 2500 W. If no expansion battery is connected, the maximum output power of the internal battery through this AC socket is 2500 W.
9.6. Environmental Requirements
| Item | Specification |
|---|---|
| Environmental Temperature | -20°C ~ 40°C |
| Ambient Humidity | 5% ~ 95% RH |
10. User Tips
- Grounding for Off-Grid Use: When using the inverter off-grid, with or without charging, it is essential to ensure proper grounding. Refer to local electrical codes and regulations for specific grounding requirements to ensure safety and optimal performance.
- Maximize Solar Savings: Utilize the app's customization features to set optimal charging and discharging times based on your electricity rates and solar generation patterns to maximize savings.
- Regular Checks: Periodically check all connections and cables for wear and tear, especially if the unit is exposed to outdoor elements.
11. Warranty & Support
For detailed warranty information, please visit the official OUKITEL website:
https://oukitel.com/pages/oukitel-power
If you encounter any issues not covered in this manual or require further assistance, please contact OUKITEL customer support or your product retailer.