Sunster TR B1

Contents

Sunster TR B1 2KW Diesel Air Heater User Manual

Model: TR B1

1. About This Manual

This manual provides comprehensive instructions for the Sunster TR B1 2KW Diesel Air Heater. It covers installation, operation, maintenance, and troubleshooting. Please read all instructions carefully before operating the device.

This manual applies to models: TP B3, TR B1, TR B2.

For any issues, please contact the customer service team via the sales platform or email: cs@sunster.tech.

2. Safety Warnings

WARNING: Read all safety warnings, instructions, illustrations, and specifications provided with this diesel heater. Failure to follow all instructions may result in electric shock, fire, and/or serious injury.

2.1 General Safety Precautions

  • Do not modify any important components of the diesel heater.
  • Do not use spare parts from other manufacturers without permission.
  • Always follow instructions and guidelines during installation and operation.
  • Only use original attachments and spare parts for installation and maintenance.
  • Do not use the heater in areas with flammable vapor or dust (e.g., fuel depots, carbon storehouses, timber storehouses, granaries, diesel/petrol stations).
  • Keep away from fuel tanks, compression tanks, fire extinguishers, clothes, or other flammable objects.
  • Do not use a cigarette lighter for startup.
  • Do not use the heater in closed and/or unventilated places.
  • Turn off the heater when refueling.
  • Do not cut off the electric power during operation.
  • If there is a fuel leak or discharge, contact Sunster for repair.
  • Place the exhaust outlet outdoors to prevent exhaust gas infiltration.
  • Do not directly cut off power to stop the heater while it is working.
  • Seal all gaps between the mounting plate and the car body.
  • The machine will stop heating after over-temperature protection. Do not power off immediately; allow it to cool naturally before turning off.

2.2 Flammable Material Warning

During installation, use, service, and disposal, ensure no flammable substances are near the exhaust pipe. The exhaust pipe's temperature can reach up to 400°C when operating. Avoid fire hazards.

2.3 Toxic Material Warning

Install the appliance with adequate ventilation to prevent carbon monoxide poisoning. Place the exhaust outlet outdoors to prevent exhaust gas from seeping in.

2.4 Fuel Tank Requirements

  • If a leak occurs, fuel should be discharged to the ground and not contact hot parts of the vehicle or load.
  • Fuel tanks containing gasoline must have an effective flame arrester at the filling port or a sealing device to completely seal the opening.

2.5 FCC Information

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This product may cause harmful interference, and (2) this product must accept any interference received, including interference that may cause undesired operation.

CAUTION: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

If interference occurs, try the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the distance between the product and the receiver.
  • Connect the product to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

3. Product Introduction

3.1 Product Overview

The Sunster diesel heater operates independently of the vehicle's engine system, powered by a 12-24V DC supply. It supports automatic and manual control modes. It uses light diesel fuel and operates normally above -40°C. Fresh air is drawn in, heated via a heat exchanger, and delivered to the desired location. Key features include a compact structure, lightweight design, high thermal efficiency, energy conservation, environmental friendliness, and ease of installation.

3.2 Explanation of Principles

3.2.1 Heat Source

Upon startup, the glow plug heats up (1-3 minutes). The fan then supplies air to the combustion chamber, and the diesel pump delivers fuel. Atomized diesel mixes with air and ignites on contact with the hot glow plug, producing heat. High-temperature exhaust gases are discharged through the bottom exhaust outlet.

3.2.2 Heating

Heat from the combustion chamber is quickly transferred to the aluminum heat exchanger and dissipated via aluminum fins into the warm air ducting. An external fan blows air across the heat exchanger, and the heated air is discharged through the warm air outlet.

3.2.3 Control

The controller is integrated into the unit for direct operation. The switch panel allows monitoring status, adjusting settings, and scheduling operations. Remote control is also possible via a dedicated application.

3.3 Internal Structure Diagram

Internal structure diagram of the diesel air heater with numbered components.
Figure 1: Internal Structure of the Sunster Diesel Air Heater
Table 1: Component List
No.Part NameNo.Part Name
1Fuel Tank2Fuel Filter
3Fuel Pump4Motor Assembly
5Combustion Chamber6Heat Exchanger
7Main Control Board8Glow Plug
9Plastic Housing10Warm Air Duct
11Air Outlet12Double-end Screw
13Fuel Line14Clamp
15Air Filter16Air Intake Pipe
17Exhaust Pipe18Muffler
19Power Cord Plug20Fuse
21LCD Control Panel22Remote Controller
23Fan Assembly Gasket24Combustion Chamber Gasket
25Glow Plug Atomization Mesh26Temperature Sensor
27Wiring Harness

4. Setup Instructions

This compact heater is designed for easy installation. You primarily need to install the exhaust pipe and connect the AC/DC power supply. Ensure the exhaust pipe is extended outdoors to vent combustion gases.

4.1 Installation Diagram

Installation diagram showing the heater unit, AC-DC adapter, air outlet pipe, hose hoops, drill nail, fixed clamp, exhaust silencer, and exhaust pipe.
Figure 2: General Installation Diagram

Note: The exhaust gas temperature can reach up to 400°C. Keep it away from pets and children, and ensure sufficient clearance from the ground to avoid damaging flooring or lawn.

4.2 Installation Precautions

4.2.1 No Side Installation

Side installation can lead to oil leaks, smoke, and carbon monoxide poisoning over time. Ensure a 10cm space around the heater for good ventilation.

If installing indoors, make holes in the wall for the exhaust pipe to be placed outdoors.

If installing outdoors, extend the exhaust pipe to prevent exhaust gases from being drawn back into the building through the rear fan, which could cause carbon monoxide poisoning.

4.2.2 Exhaust Pipe and Air Inlet

  • The air inlet must not be blocked; keep it open and clear.
  • Keep the exhaust pipe clear. The exhaust pipe outlet must be kept away from flammable materials to prevent heating and ignition of goods.
  • For optimal combustion, the smoke exhaust pipe must be placed horizontally or downward, not upward.
Diagram showing correct and incorrect installation directions for the exhaust pipe. Correct shows horizontal or downward, incorrect shows upward.
Figure 3: Correct and Incorrect Exhaust Pipe Installation

4.3 Power Supply Precautions

  • The power supply must be 12-24V DC with a current of ≥12A.
  • Do not charge the battery while using the heater if it's powered by a battery, as insufficient current can cause malfunction.
  • Ensure a firm and secure connection to the battery. Poor contact can result from using clamps for fixation.
  • If extending the power cable, the wire diameter should be >2 mm². Thin wires can lead to insufficient current. Use insulating tape to protect connections and prevent electrical leakage.
  • Do not disconnect power when the heater is operating at high temperatures to avoid backfire and permanent damage.
  • If power is cut and you immediately turn on the heater, wait until the internal heat has dissipated.
  • If the heater is turned on after a long power cut, incomplete combustion may produce smoke. Wait for the smoke to clear before normal operation.
  • Use high-grade diesel fuel. Do not use kerosene, vegetable oil, gasoline, waste oil, etc., as this can cause unpleasant odors and malfunctions.

4.4 Installation Video Guide

Video: Sunster TR B1 All-in-One Series Installation Guide. This video demonstrates the step-by-step installation process for the air intake pipe, muffler, exhaust pipe, air outlet pipe, power circuit, and remote/app control setup.

Key Installation Steps from Video:

  1. Install the Air Intake Pipe: Connect the air intake pipe and secure it with a clamp.
  2. Install the Air Intake Pipe and Main Body: Attach the air intake pipe to the main heater body and secure the connection.
  3. Install the Muffler: Connect the muffler to the exhaust pipe and tighten the clamp.
  4. Install the Exhaust Pipe and Main Body: Attach the exhaust pipe to the main heater body and secure it.
  5. Install the Air Outlet Pipe: Connect the air outlet pipe and secure it with a clamp.
  6. Install the Air Outlet Pipe and Main Body: Attach the air outlet pipe to the main heater body and secure the connection.
  7. Install the Power Circuit: Connect the power supply, paying attention to positive and negative poles. Secure the connections to the battery terminals.
  8. Heater Starts Normally After Installation: Power on the heater and observe normal startup.
  9. Control the Heater Remotely with the Remote Controller: Pair the remote controller by long-pressing the 'up' key on the heater's LCD panel while in power-on status, then press any button on the remote.
  10. Connect to the App via Mobile Bluetooth: Scan the QR code in the manual to download the Sunster App, then connect via Bluetooth.

Important Installation Instructions from Video:

  1. The exhaust outlet temperature can reach up to 400°C. Keep away from children, pets and flammable materials.
  2. Place the exhaust outlet outdoors to prevent exhaust gas infiltration.
  3. During operation, keep flammable or explosive substances away from the exhaust pipe area to prevent ignition of combustibles and potential fire hazards.

5. Operating Instructions

5.1 2602B Controller

5.1.1 Panel Labeling Description

Diagram of the 2602B controller panel with numbered labels for knob, setting button, and power button.
Figure 4: 2602B Controller Panel Layout
Table 2: 2602B Controller Panel Elements
No.Description
1Knob
2Setting Button
3Power Button

5.1.2 Operating Procedures

  1. Power On: In standby, press the Power Button. The display will show current operating status.
  2. Power Off: In power-on mode, press the Power Button. The display will turn off after the shutdown sequence.
  3. Mode Switching: Press the Setting Button once to switch between Temperature Control Mode, Ventilation Mode, and High Heat Mode.

    Note: Ventilation Mode and High Heat Mode require a specific mainboard. Otherwise, "Err" will be displayed, and it will revert to Temperature Control Mode.

  4. Constant Temperature Mode: This mode must be configured in the settings menu. Once configured, it replaces Temperature Control Mode.
  5. Parameter Adjustment: Rotate the knob to adjust the target gear level or temperature.

5.1.3 Functional Settings Operation Guide (2602B)

In power-on mode, press and hold the Setting Button for 3 seconds to enter settings. Rotate the knob to select items. Press Setting Button to modify/confirm.

Table 3: 2602B Controller Settings
ItemFunction NameDescription
1Current Time SettingPress Setting Button, rotate knob to modify, press again to confirm.
2Timed On SettingPress Setting Button, rotate knob to modify, press again to confirm.
3Timed Off SettingPress Setting Button, rotate knob to modify, press again to confirm.
4Timer Function On/Off SettingPress Setting Button to modify ("OF" for Off, "ON" for On), press again to confirm.
5Voice Prompt Language SettingPress Setting Button, rotate knob to modify ("EN" for English, "GE" for German, "rU" for Russian, "OF" for Off), press again to confirm.
6Ambient Temperature Compensation SettingAdjusts for deviation between displayed and actual ambient temperature. Range: -27°C to 27°C. Default: 0°C.
7Constant Temperature Function Setting"ON" to enable, "OF" to disable. Replaces Temperature Control Mode when enabled.
8Temperature Unit Switch SettingSwitch between Fahrenheit (°F) and Celsius (°C).
9Screen Brightness After Inactivity SettingAdjust brightness (0-10). After 1 minute of inactivity, controller changes to set brightness.
10Bluetooth Password Modification SettingEnter password modification mode, view local Bluetooth ID. Modify via APP.
11Altitude Unit Switch SettingSwitch between meters (m) and thousand feet (Kft).
12Constant Temperature Mode Auto-On Temperature DifferenceDefault 4°C. Range 2°C to 18°C.
13Constant Temperature Mode Auto-Off Temperature DifferenceDefault 2°C. Range 0°C to 18°C.
14Carbon Monoxide (CO) Alarm Value SettingDefault 50 PPM. Range 0-500. Requires smart remote. Alarm triggers when value reached. (0 disables alarm).
15Carbon Monoxide (CO) Shutdown Value SettingDefault 100 PPM. Range 10-500. Requires smart remote. Heater automatically powers off when value reached.

5.1.4 Remote Control Pairing (2602B)

  • Universal Remote Control Pairing / Clearing: In power-off mode, long-press the knob. "rtE" will display. Press any button on the remote to pair. For clearing, continue holding the knob until "C L r" appears.
  • Smart Remote Control Pairing / Clearing: In power-off mode, long-press the Power Button. "ADD" will display. Put the smart remote into pairing mode. For clearing, continue holding the Power Button until "C L r" appears.

5.1.5 Forced Fuel Priming

For first-time use or when the fuel line is not full, use forced fuel priming. Disconnect power for >10 seconds, reconnect, then long-press the Setting Button. The fuel pump will operate at a higher frequency, and a 300s countdown will begin. If ignition is successful, it returns to normal operation. If not, it exits priming mode after countdown.

5.1.6 Bluetooth Connection and APP Binding

Open the APP and add the device via Bluetooth. The APP will search automatically. Press and hold both the knob and Setting Button on the switch to enter Engineering Mode. Rotate to Item 9 to view the local Bluetooth ID. Find this ID in the APP to bind.

To modify the Bluetooth password: Bind the device via APP, go to "More Settings" > "Property Settings" > "Password Settings". The controller needs to be in pairing mode (Item 10 in settings). Modify the password in the APP; it will sync to the controller.

5.1.7 Engineering Mode

In power-on mode, press and hold both the knob and Setting Button to enter Engineering Mode to view operating status. Rotate the knob to cycle through items.

Table 4: 2602B Engineering Mode Parameters
Parameter CodeParameter Meaning
En00Heater Mainboard Firmware Version
En01Fault Code
En02Combustion Chamber Temperature
En03Supply Voltage
En04Current Operating Gear
En05Local Ambient Temperature
En06Current Altitude
En07Signal Strength of Remote Control Connection
En08Local Bluetooth ID

5.2 2200BSH Controller

5.2.1 Panel Labeling Description

Diagram of the 2200BSH controller panel with numbered labels for increase button, setting button, power button, and decrease button.
Figure 5: 2200BSH Controller Panel Layout
Table 5: 2200BSH Controller Panel Elements
No.Description
1Increase button
2Setting button
3Power button
4Decrease button

5.2.2 Operating Modes (2200BSH)

  • Ventilation Mode: Fan only, no heating. Fan speed 1-10.
  • Temperature Control Mode: Operating level adjusts automatically based on set vs. ambient temperature. Min level 1 (continuous operation). Temp range: 8-36°C.
  • Constant Temperature Mode: Similar to Temperature Control Mode, but heating stops and unit enters standby when ambient temp exceeds set temp by 2°C. Resumes when ambient temp drops 2°C below set temp.
  • Heating Mode: Heating at set level (1-10 levels).
  • High-Heat Mode: Max output power, max 2 hours continuous runtime.

5.2.3 Functional Settings Operation Guide (2200BSH)

Basic Settings: In power-on state, press and hold the setting button for 3 seconds to enter settings. Use increase/decrease buttons to switch items. Press mode button to confirm/enter. Hold mode button for 3 seconds to save and exit.

Table 6: 2200BSH Controller Settings
ItemFunction
1Current time setting
2Scheduled start time setting
3Setting the running time after scheduled start
4Timing function on or off setting
5Ambient temperature compensation setting
6Bluetooth function switch setting
7Remote control function switch settings
8Constant temperature mode function setting
9Temperature unit switch setting
10Adjust screen brightness after no operation
11Receive smart carbon monoxide alarm shutdown settings

5.2.4 Remote Control Operation (2200BSH)

  • Remote Control Pairing/Clearing: With device powered on, press and hold the Add button to enter pairing mode ("P-1" displayed). Press any remote button to pair. For clearing, power off, hold Power button until "CLr" or "SUC" appears.
  • Broadcast Language Switch: With device powered on, hold Setting and Decrease buttons for 3 seconds to switch languages (ru, en, GE, OF).
  • Forced Fuel Pumping: Disconnect power for >10s, reconnect. After self-check, hold decrease button for ~7s. Fuel pump operates at higher frequency. Press power off to exit.
  • Connecting and Binding with Bluetooth in the App: Open app, add device via Bluetooth. With device powered on, hold Increase and Decrease buttons to enter Engineering Mode. Adjust to item 10 to view Bluetooth ID. Bind in app.
  • Restoring to Factory Settings: With device powered on, hold Increase and Decrease buttons for 3 seconds to enter Engineering Mode. Adjust to Item 11 (Reset). Hold Set button until self-test completes.

5.2.5 Carbon Monoxide Alarm (2200BSH)

If CO level exceeds set alarm value, remote will sound an alarm. Press buzzer switch to silence. If CO exceeds 500 PPM, remote automatically shuts down device and displays fault code 11.

6. Maintenance

  • If black smoke is observed during operation or in the second year of use, it indicates carbon accumulation in the combustion chamber. This requires timely cleaning.
  • If any of the above situations occur, replace the Air Filter and Fuel Filter.

7. Troubleshooting (Fault Code Table)

Table 7: Fault Code Explanations and Solutions
Fault CodeFault ReasonSolution
E01Voltage Abnormality1. Check if heater supply voltage matches vehicle voltage. 2. For 24V: Check if voltage is >32V or <18V. 3. For 12V: Check if voltage is >18V or <9V. 4. Check if main wiring harness connector is loose or has poor contact.
E03Glow Plug Abnormality1. Check if glow plug connector has poor contact. 2. Glow plug is faulty; replace. 3. Main control board is faulty; replace.
E04Fuel Pump Abnormality1. Check if fuel pump connector is loose or has poor contact. 2. Check if main wiring harness is open-circuited. 3. Fuel pump is faulty; replace.
E05Overheat Protection1. Check if heater air inlet is blocked. 2. Check if heater air outlet is blocked.
E06Fan Abnormality1. Check if fan impeller is stuck. 2. Check if fan connector is loose or has poor contact. 3. Fan is faulty; replace. 4. Check if fan wheel induction magnet is missing or has wrong polarity. 5. Main control board is faulty; replace.
E07Air Intake Sensor Abnormality1. Main control board is faulty; replace.
E08Fuel shortage and flameout1. Fuel tank is out of fuel.
E09Overheat sensor abnormality1. Check if temperature sensor connector is loose or poorly connected. 2. Sensor fault; replace. 3. Mainboard fault; replace.
E10Startup failure1. Check if fuel pump is working. 2. Check if each oil circuit interface is waxed or blocked.
E11Carbon monoxide exceeding standard1. Environmental CO concentration exceeds standard. Open window for ventilation, evacuate environment immediately.

8. Specifications

Table 8: Product Specifications (Model TR B1)
FeatureDetail
ModelTR B1 (2KW All-in-one Unit 2200BH + 4-Gear Remote)
Heating Power2KW (Max Combustion Power)
Voltage SystemDual Power Supply - 12V/24V DC & 110-240V AC (Home Adapter Included)
Control MethodsLCD Screen / Remote Controller / Bluetooth APP
Fuel Consumption0.1 - 0.26 L/H (Ultra-Low)
Fuel Tank5L Built-in Tank (Up to 40 Hours Continuous Heating)
Noise Level≤35dB (Silent Oil Pump & Upgraded Quick-Connect Silencer, No Ticking Sound)
Safety ProtectionOverheat / Low Voltage / Short-Circuit Protection
Item Weight7.1kg
Item Height37cm
Item Width13cm
Item Length36.5cm
MaterialAluminum + Plastic
CertificationRoHS, CE, UKCA, ETL, ECE R122 & R10

8.1 Package Contents

Image showing all components included in the package: Air Diesel Heater, Air Filter, Air Outlet Grid, Fixed Plate, Air Outlet Pipe, Intake Pipe, Exhaust Pipe, Manual, Battery Power Cord, Fixture Accessories Set, Silencer, LCD Switch, Remote Control.
Figure 6: Package Contents

The complete kit includes:

  • 1 x 2KW Air Diesel Heater (12V/24V Auto + 110-240V AC Adapter)
  • 1 x 5L (1.3GAL) Fuel Tank
  • 1 x LCD Switch & Remote Control
  • 1 x AC-DC Power Adapter & Battery Power Cord
  • 1 x Silent Oil Pump & Silencer
  • 1 x Air Outlet Pipe, Intake Pipe, Exhaust Pipe
  • 1 x Fixed Plate, Fixture Accessories Set & Manual

9. Warranty and Support

Sunster is a proprietary brand with a mature technical team and established production lines. All products hold certifications from authoritative bodies such as CE, WEEE, FCC, EAC, and UKCA.

If you encounter any issues, please contact the store's customer service team directly via the sales platform or reach out via email: cs@sunster.tech.

Business Inquiries: sunster@sunster.tech.

Sunster reserves the right of final interpretation of the user manual. The appearance of the product is subject to the actual item received. Products are subject to technical or software updates without prior notice.

9.1 App Download

The Sunster App allows for Bluetooth control of the heater. Scan the QR codes below or search "Sunster" in your app store.

QR code for Android App download.
Android App
QR code for iOS App download.
iOS App

10. User Tips

  • Optimal Fuel: Always use high-grade diesel fuel for best performance and to avoid unpleasant odors or malfunctions.
  • Ventilation is Key: Ensure proper ventilation, especially when operating indoors, and always direct exhaust gases outdoors to prevent carbon monoxide buildup.
  • Secure Connections: Double-check all pipe and power connections during installation to prevent leaks and ensure safe operation.
  • Remote Control Pairing: If you have trouble pairing the remote, ensure the heater is in the correct pairing mode (power-on status, long-press 'up' key for 2602B; power-off status, long-press Power Button for smart remote).
  • App Connectivity: If the Bluetooth app connection fails, verify the connection password in the controller's settings (Item 10 for 2602B) matches the app.
  • Cool-down Cycle: Do not immediately disconnect power after turning off the heater; allow it to complete its cool-down cycle (3-5 minutes) to prevent damage.