Sunster TP B1

Contents

Sunster TP B1 8KW All-in-one Diesel Air Heater User Manual

Models: TP B1 / TP G1

1. General Information

Sunster is a proprietary brand dedicated to providing superior heating systems. Our products are certified by authoritative bodies such as CE, WEEE, FCC, EAC, and UKCA.

This manual applies to the following models: TP B1 / TP G1.

Please read all instructions carefully before operating. The product complies with relevant standards and regulations. Installation and operation must comply with all applicable regulations and should only be performed in well-ventilated areas.

Always check the product for abnormalities before use. If any abnormality is detected, discontinue use immediately.

Use the product only for its intended purpose. Misuse can lead to potential injury.

2. Safety Warnings

WARNING: Read all safety warnings, instructions, illustrations, and specifications provided with this diesel heater. Failure to follow all instructions may result in electric shock, fire, and/or serious injury.

⚠ General Precautions:

  • Do not modify important components of the diesel heater.
  • Do not use spare parts from other manufacturers without permission.
  • Always follow instructions and guidelines during installation and operation.
  • Only use original attachments and spare parts for installation and maintenance.

🔥 Flammable Material Warning:

  • Heaters must not be used in areas with flammable vapor or dust (e.g., fuel depots, carbon/timber storehouses, granaries, diesel/petrol stations).
  • Keep the heater away from fuel tanks, compression tanks, fire extinguishers, clothes, or other flammable objects.
  • Do not use a cigarette lighter for startup.
  • Turn off the heater when refueling.
  • The exhaust pipe temperature can reach up to 400°C. Keep away from children, pets, and flammable materials.
  • During operation, keep flammable or explosive substances away from the exhaust pipe area to prevent ignition.

☠ Toxic Material Warning:

  • Do not use the heater in closed and/or unventilated places.
  • Install the appliance with space for ventilation to prevent carbon monoxide poisoning.
  • Place the exhaust outlet outdoors to prevent exhaust gas infiltration.

⚡ Electrical & Power Warnings:

  • Do not cut off the electric power directly during operation. The machine requires 3-5 minutes to stop completely after being turned off.
  • If there is a fuel leak or discharge from the fuel system, contact Sunster for repair.
  • The power supply must be 12-24V DC with a current of 12A or greater.
  • When extending the power cable, the wire diameter should be >2 mm². Use insulating tape to protect connections.
  • Do not charge the battery while using the heater, as insufficient current can cause malfunction.
  • If the heater stops due to over-temperature protection, do not power off immediately. Allow it to cool naturally.

FCC Information

CAUTION: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This product may cause harmful interference. (2) This product must accept any interference received, including interference that may cause undesired operation.

If this product causes harmful interference to radio or television reception, try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the distance between the product and the receiver.
  • Connect the product to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

3. Product Overview & Specifications

3.1 Product Overview

The Sunster TP B1 diesel heater operates independently of the vehicle's engine system, powered by a 12-24V DC supply. It offers automatic and manual control modes. Using light diesel fuel, it operates normally at temperatures above -40°C. Fresh air is drawn in, heated via a heat exchanger, and delivered to the desired location. Key advantages include a compact structure, lightweight design, high thermal efficiency, energy conservation, environmental friendliness, and ease of installation.

How it Works:

  1. Heat Source: Upon startup, the glow plug heats up (1-3 minutes). The fan supplies air to the combustion chamber, and the diesel pump delivers fuel. Atomized diesel mixes with air and ignites, generating heat. High-temperature exhaust gases are discharged through the bottom exhaust outlet.
  2. Heating: Heat is rapidly transferred to an aluminum heat exchanger and dissipated via aluminum fins into warm air ducting. An external fan blows air across the heat exchanger, and the heated air is discharged through the warm air outlet.
  3. Control: The controller is integrated into the unit, allowing for direct operation via a switch panel or a dedicated mobile application for remote control.

3.2 Internal Structure & Parts

The diagram below illustrates the internal components and connections of the diesel air heater.

Diagram of the diesel air heater with labeled components and accessories.

Figure 1: Sunster TP B1 Diesel Air Heater with included accessories.

Table 1: Parts List
No.Part NameNo.Part Name
1Fuel Tank2Fuel Filter
3Fuel Pump4Motor Assembly
5Combustion Chamber6Heat Exchanger
7Main Control Board8Glow Plug
9Plastic Housing10Warm Air Duct
11Air Outlet12Double-end Screw
13Fuel Line14Clamp
15Air Filter16Air Intake Pipe
17Exhaust Pipe18Muffler
19Power Cord Plug20Fuse
21LCD Control Panel22Remote Controller
23Fan Assembly Gasket24Combustion Chamber Gasket
25Glow Plug Atomization Mesh26Temperature Sensor
27Wiring Harness

3.3 Technical Specifications (Model: TP B1)

Table 2: Technical Specifications
AttributeValue
Heater Power8KW
Switch TypeLCD Switch
Fuel TypeDiesel
Special FeaturesHeating & Ventilation mode, Bluetooth APP Function, Automatic Start & Stop (constant temperature), Turbo Heat Mode, Ventilation Function, Display Altitude, Timer Switch
Item Weight10 kg
Item Dimensions (L x W x H)42cm x 25cm x 30cm
Brand NameSunster
OriginMainland China
CertificationRoHS, CE
Supply VoltageDC12V / DC24V / AC110-240V
Operating Voltage Range10.5-16V / 21-32V
Power Adapter InputAC110-240V 50-60Hz
Control MethodLCD + Remote Control + Bluetooth
Startup Current13A
Rated Current3A
Applicable Range215-269ft² / 20-25m²
Power Consumption0.036KW/H
Fuel Consumption0.16-0.45 (L/H)
Tank Capacity5L / 1.3 gal
Adjustable Temp. Range8℃-35℃ / 46℉-95℉
Heater Working Temperature-40℃~+20℃ / -40℉~+68℉
Oil Pump Working Temperature-40℃~+20℃ / -40℉~+68℉
Air Outlet Pipe Inner Diameter2.95inch / 75mm

4. Setup (Installation Instructions)

This compact heater is designed for relatively easy installation. The main steps involve installing the exhaust pipe and connecting the AC/DC power supply. Ensure the exhaust pipe is extended outdoors to vent combustion gases safely.

4.1 Installation Diagram

Installation diagram showing the heater, AC-DC adapter, air outlet pipe, exhaust pipe, and various connections.

Figure 2: General installation overview of the Sunster TP B1 heater.

4.2 Installation Steps (Video Guide)

For a detailed step-by-step installation guide, please watch the official video:

Video 1: Sunster TP B1 All-in-one Series Installation Guide. This video demonstrates the assembly of the foot brackets, intake pipe, exhaust pipe, air outlet pipe, power wiring, and initial startup.

Key steps shown in the video:

  1. Install the foot bracket: Press firmly down to the bottom.
  2. Install the intake pipe: Connect the intake pipe to the intake filter and secure with a clamp.
  3. Install the intake pipe to the main body: Attach the assembled intake pipe to the heater's main body and secure.
  4. Install the exhaust pipe and muffler: Connect the muffler to the exhaust pipe and secure with a clamp.
  5. Install the exhaust pipe to the machine: Attach the assembled exhaust pipe to the heater's main body.
  6. Install the air outlet pipe to the main body: Connect the air outlet pipe to the heater's main body and secure with a clamp.
  7. Install the power wiring: Connect the red wire to the positive terminal and the black wire to the negative terminal of the power supply (e.g., a 12V/24V battery). Ensure secure connections.
  8. Heater starts normally after installation: Power on the unit and observe normal operation.
  9. Control the heater with the remote controller: Demonstrate basic remote control functions.
  10. Connect to the App via mobile Bluetooth: Scan the QR code from the manual to download the app, then connect via Bluetooth.

4.3 Installation Precautions

4.3.1 No Side Installation

Side installation of the diesel heater can lead to oil leaks inside the machine over time, resulting in smoke and carbon monoxide poisoning. Always ensure a minimum of 10cm space around the heater for good ventilation.

4.3.2 Exhaust Pipe Placement

  • Indoor Placement: If the heater is placed indoors, drill holes in the wall to route the exhaust pipe outdoors. Insulate the exhaust pipe as it can become very hot and pose a fire hazard.
  • Outdoor Placement: If the heater is placed outdoors, extend the exhaust pipe sufficiently to prevent exhaust gases from being drawn back into the building through the heater's rear fan, which can cause carbon monoxide poisoning.
  • The exhaust pipe outlet must be kept clear and away from any flammable materials.
  • To ensure optimal combustion, the smoke exhaust pipe must be placed horizontally or downward, never upward.

4.3.3 Power Supply Precautions

  • The power supply for the diesel heater must meet the following requirements: Voltage: 12-24V; Current: ≥12A.
  • If using a battery, do not charge the battery while the heater is in operation, as insufficient current can cause malfunction.
  • Ensure a firm and secure connection to the battery. Loose clamps can result in poor contact.
  • When extending the power cable, the wire diameter should be >2mm². Using a thinner wire can lead to insufficient current and prevent the heater from working. After connecting, use insulating tape to protect the connection and prevent electrical leakage.
  • Do not disconnect the power when the diesel heater is operating at high temperatures. This can cause a backfire due to high temperatures and permanent damage. If power is cut, wait until the internal heat has completely dissipated before restarting.

5. Operating Instructions

The Sunster TP B1 heater can be controlled via its integrated LCD panel, a remote control, or a mobile application.

5.1 Controller (Model 2201B)

The TP B1 model uses the 2201B controller, which features a knob and a power button for operation.

Image showing the 2201B LCD controller with a knob and power button, along with a remote control and a smartphone displaying the app interface.

Figure 3: The 2201B controller, remote, and mobile app interface.

5.1.1 Operating Modes

  1. Temperature Control Mode: Automatically adjusts heating level based on the difference between set and ambient temperature. Range: 8-36°C. Minimum operating level is Level 1; the heater does not automatically shut down in this mode.
  2. Gear Mode: Heats according to a selected gear level (1-5).
  3. Ventilation Mode: Only the fan operates (no heating). Fan speed can be set to Gear 1-5.
  4. Boost Heating Mode: Operates at maximum output power for a maximum of 2 hours.
  5. Thermostat Mode: Automatically adjusts heating based on set and ambient temperature. Range: 8-36°C. Heating stops when ambient temperature is 1°C higher than set temp (enters standby). Heating restarts when ambient temperature is 2°C lower than set temp (enters power-on mode).

5.1.2 Basic Operations

  • Power On: In standby, press the Power Button. The display will illuminate, showing current status.
  • Power Off: In power-on mode, press the Power Button. The display will turn off after the shutdown sequence.
  • Mode Switching: In power-on mode, press the knob once to switch between modes.
  • Parameter Adjustment: Rotate the knob to adjust the target gear level or temperature.

5.1.3 Functional Settings (General System Settings)

In power-on mode, press and hold the Setting Button for 3 seconds to enter settings mode. Rotate the knob to select items. Press the Setting Button to modify, rotate the knob to change values, and press again to confirm.

Table 3: Functional Settings
ItemFunction NameParameter Adjustment Description
1Current Time SettingSet the current time.
2Timed On SettingSet a specific time for the heater to turn on.
3Timed Off SettingSet a specific time for the heater to turn off.
4Timer Function On/Off SettingEnable (ON) or disable (OF) the timer function.
5Voice Prompt Language SettingSelect language (EN for English, GE for German, rU for Russian, OF for Off).
6Ambient Temperature Compensation SettingAdjust temperature compensation (-27°C to 27°C) if there's a deviation between displayed and actual ambient temperature. Note: If a remote control is connected, its temperature is used.
7Constant Temperature Function SettingEnable (ON) or disable (OF) Constant Temperature Mode. When enabled, it replaces Temperature Control Mode.
8Temperature Unit Switch SettingSwitch between Fahrenheit (°F) and Celsius (°C).
9Altitude Unit Switch SettingSwitch between meters (m) and thousand feet (Kft).
10Unbind the controller from the appLong press the setting key in settings mode (Item 10, "CLr" displayed) to unbind.

5.1.4 Forced Fuel Priming

When installing for the first time or if the fuel pipeline is not filled, use forced fuel priming. Disconnect power for >10s, reconnect, then press and hold the Setting Button. The fuel pump will operate at a higher frequency, and a 300s countdown will begin. If ignition is successful, it returns to normal operation. If not, it exits priming mode.

5.1.5 Engineering Mode

In power-on mode, press and hold both the knob and the Setting Button to enter Engineering Mode. Rotate the knob to view operating status parameters:

Table 4: Engineering Mode Parameters
ItemParameter Meaning
1Heater Mainboard Firmware Version
2Fault Code
3Furnace Body Temperature
4Power Supply Voltage
5Current Operating Gear
6Switch Local Ambient Temperature
7Current Altitude
8SIM Card Signal (for 2602BLTE controller) / Local Bluetooth ID (for 2201B controller)
9Factory Reset

5.1.6 Remote Control

The TP B1 comes with a remote control for convenient operation from a distance.

Remote control for the diesel air heater.

Figure 4: Remote control unit.

  • Matching Remote Control: In power-on mode, press the knob three times consecutively to enter remote control matching mode ("r_tE" displayed). Press any button on the remote to start matching.
  • Clearing Remote Control Matching: Disconnect power to the switch. Long-press the power button, reconnect power while holding the button. "C L r" will appear. When "S U C" appears, clearing is successful.

5.1.7 Mobile App Control

The heater can be controlled via a mobile app (iOS/Android) connected via Bluetooth.

Smartphone displaying the Sunster app interface for heater control.

Figure 5: Multiple Smart App Control features including timing, blow mode, temperature setting, gear setting, and automatic start/stop.

  • App Download: Scan the QR code in the manual to download the Sunster App for Android (Google Play) or iOS (App Store).
  • Bluetooth Connection and APP Binding: Open the app and add the device. For scanning, scan the IMEI code on the back of the controller. For manual addition, enter the 15-digit IMEI number. Put the controller into settings mode (Item 12, "-E1-" interface), press the setting key to query. The binding is complete after successful input. The icon in the upper right corner of the controller being constantly on indicates successful network access.
  • Modify Bluetooth Connection Password: After binding, enter the app's operation interface, go to More Settings > Property Settings > Password. The switch needs to be in matching mode (Engineering Mode, Item 8 to display local Bluetooth ID). Long-press the button on this screen to display the local Bluetooth connection password. Enter the password in the app to modify.

6. Maintenance

Regular maintenance ensures the longevity and efficient operation of your Sunster diesel air heater.

  • Carbon Accumulation: If black smoke is observed during operation or in the second year of use, it indicates carbon accumulation in the combustion chamber. This requires cleaning.
  • Filter Replacement: If carbon accumulation occurs, or if the air filter or fuel filter are clogged, replace them in a timely manner.
  • Fuel Type: Always use high-grade diesel fuel. Do not use kerosene, vegetable oil, gasoline, waste oil, etc., as this can cause unpleasant odors and malfunction.

6.1 Factory Reset

In power-on mode, press and hold both the knob and the power button simultaneously to enter engineering mode. Then, rotate to Item 9. The interface will display "r s t". Long-press the knob. When the screen performs a self-test, it indicates that the factory reset was successful.

7. Troubleshooting (Fault Code Table)

If your heater encounters an issue, a fault code may be displayed on the LCD screen. Refer to the table below for common fault codes and their solutions.

Table 5: Fault Code Table
Fault CodeDescriptionSolution
E01Voltage Abnormality
  • Check if heater supply voltage matches vehicle voltage.
  • For 24V: Check if voltage is >32V or <18V.
  • For 12V: Check if voltage is >18V or <9V.
  • Check if main wiring harness connector is loose or has poor contact.
E03Glow Plug Abnormality
  • Check if glow plug connector has poor contact.
  • Glow plug is faulty, replace the glow plug.
  • Main control board is faulty, replace the main control board.
E04Fuel Pump Abnormality
  • Check if fuel pump connector is loose or has poor contact.
  • Check if main wiring harness is open-circuited.
  • Fuel pump is faulty, replace the fuel pump.
E05Overheat Protection
  • Check if heater air inlet is blocked.
  • Check if heater air outlet is blocked.
E06Fan Abnormality
  • Check if fan impeller is stuck.
  • Check if fan connector is loose or has poor contact.
  • Fan is faulty, replace the fan.
  • Check if the fan wheel induction magnet is missing or has wrong polarity.
  • Main control board is faulty, replace the main control board.
E07Air Intake Sensor AbnormalityMain control board is faulty, replace the main control board.
E08Fuel Shortage and FlameoutFuel tank is out of fuel.
E09Overheat Sensor Abnormality
  • Check if the temperature sensor connector is loose or poorly connected.
  • Sensor fault, replace the sensor.
  • Mainboard fault, replace the mainboard.
E10Startup Failure
  • Check if the fuel pump is working.
  • Check if each oil circuit interface is waxed or blocked.
E11Carbon Monoxide Exceeding StandardThe environmental CO concentration exceeds the standard. Open windows for ventilation immediately and evacuate the area.

8. Warranty & Support

Sunster is not responsible for issues arising from non-compliance with these instructions or from repairs conducted without professional maintenance or the use of original spare parts/accessories. Such unauthorized maintenance will invalidate the heater's type approval and its ECE type approval certificate.

If you encounter any issues, please contact the store's customer service team directly via the sales platform or reach out to us via email:

Certifications

The Sunster TP B1 heater is fully compliant with CE, RoHS, UKCA, ETL, ECE R122 & R10 international standards, ensuring quality and safety.

Certifications including RoHS, UKCA, E57, R10, R122, CE.

Figure 6: Product certifications for safety and quality.

9. User Tips

  • Fuel Quality: Always use high-grade diesel fuel to prevent unpleasant odors and ensure optimal performance. Avoid using alternative fuels like kerosene or gasoline.
  • Ventilation is Key: Ensure adequate ventilation, especially when operating indoors, and always route exhaust gases outside to prevent carbon monoxide buildup.
  • Gradual Shutdown: Never abruptly disconnect power during operation. Allow the heater to complete its shutdown cycle (3-5 minutes) to prevent damage and backfire.
  • App Connectivity: If you experience issues with the mobile app connection, double-check the Bluetooth password and ensure the controller is in the correct binding mode.
  • Regular Checks: Periodically inspect the air and fuel filters, and clean the combustion chamber if you notice black smoke, indicating carbon accumulation.

© 2024 Sunster. All rights reserved. Product appearance and specifications are subject to change without prior notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.