AIFEN AIFEN-F4

Contents

AIFEN F4 Hot Air Gun Rework Station

Model: AIFEN-F4

1. Safety Attention

Please read the following safety precautions carefully before using this de-soldering station.

  1. Follow the manual to use this de-soldering station. DO NOT use it for unspecified purposes.
  2. The air outlet and its nearby areas are extremely hot. Be careful so as not to be burnt.
  3. In the idle state, the handle must be placed on the handle rack in a correct manner. DO NOT place it on the working station or another place. After the job is done, allow the de-soldering station to cool down below 100°C (entering into the sleeping mode) before turning off the power switch.
  4. Keep the air outlet unblocked. Any blockage must be cleared.
  5. DO NOT place a sharp object on the air outlet hose as the latter may be damaged.
  6. When using this de-soldering station, maintain at least 2mm between the air outlet and the target item.
  7. Different wind nozzles with slightly different temperatures can be selected for different applications.
  8. If this de-soldering station will not be used for a long time, pull out the power plug.
  9. Handle the de-soldering station with care. DO NOT tap on the handle or violently shake the station.
  10. Regularly check and maintain this station. DO NOT use it when it has damages, especially when the power cable or air gun handle wire is damaged.
  11. DO NOT use this station when it is wet or when your hands are wet; otherwise you may risk a short circuit or electric shock.
  12. DO NOT use this station near inflammable gases or other combustible substances. After using this station, DO NOT place it around inflammable gases or other combustible substances immediately.
  13. Children are unaware of how dangerous electric products can be. DO NOT use or store this station in a place accessible to a child. DO NOT allow a child to get near or touch this station.

2. Product Overview

The AIFEN F4 Hot Air Gun Rework Station is a high-power, intelligent, stable, and precise tool designed for various soldering and welding tasks. It features a digital display for easy monitoring and control.

AIFEN F4 Hot Air Gun Rework Station with 'Intelligent', 'Stable', 'Precise' labels
The AIFEN F4 Rework Station is designed for intelligent, stable, and precise operation.

Key Features:

  • Four Working Channels: CH1, CH2, CH3, and CH4, each with settable and storable airflow and temperature.
  • Multiple Protection Functions: Ensures safe and reliable operation.
  • Magnetic Control Switch: Handle placed on the rack immediately enters hibernation for real-time operation.
  • Automatic Sleep Function: Parameters can be set in dormant state.
  • Sensor Closed Loop Control: Microcomputer zero trigger temperature control for rapid heating, stable temperature adjustment, unaffected by airflow.
  • Brushless Vortex Fan: Adjustable air volume (1-160 levels) for a wide range of applications.
  • Automatic Cooling Function: Extends heating element life and protects the hot air handle.
  • Durable Heating Core: Designed for long-lasting performance.
  • Easy Nozzle Installation: Quick and simple attachment of various nozzles.
AIFEN F4 Hot Air Gun Rework Station highlighting features like 6 nozzles, sleep stand, instant heating, and constant temperature technology.
Equipped with 6 nozzles, integrated sleep stand, instant heating, and constant temperature technology.
AIFEN F4 Hot Air Gun Rework Station with text 'Long Lifespan 1000W High Power Hot Air Gun'
The AIFEN F4 features a long lifespan and 1000W high power.
Demonstration of AIFEN F4 Hot Air Gun features including rapid heating, quick cooling, memory storage keys, air volume regulation, temperature range, and easy nozzle installation.

3. Specifications

ParameterValue
Power1000W
VoltageAC 230V 50/60HZ, AC 110V 50/60 HZ
Temperature Range100-500°C (212-932°F)
Airflow Levels1-160
Fuse220V 10A, 110V 20A
Inner Box Dimensions35 x 28 x 21 CM
Gross Weight (Inner Box with Unit)2.4 KG
Main Unit Weight1.56 KG
Unit Dimensions (approx.)15.5cm (W) x 13cm (H) x 21.5cm (D)
AIFEN F4 Hot Air Gun Rework Station with dimensions labeled: 15.5cm width, 13cm height, 21.5cm depth.
Product dimensions and weight specifications.

Plug Types and Compatible Regions:

Table showing different plug types (US, EU, UK, AU) and their suitable countries.
Refer to this table for plug type compatibility. Note: Power and plug are for reference. Please refer to the socket in your home for accuracy.
  • US Plug: China Taiwan, Japan, United States, Canada, Mexico, etc.
  • EU Plug: Germany, France, Netherlands, Denmark, Finland, Norway, Poland, Spain, Sweden, Korea, Russian Federation, etc.
  • UK Plug: Hong Kong, UK, Saudi Arabia, Pakistan, Singapore, Malaysia, UAE, Nigeria, Maldives, Qatar, etc.
  • AU Plug: Australia, New Zealand, Argentina, etc.

4. Setup

4.1 Unpacking and Inspection

Upon receiving your AIFEN F4 Rework Station, carefully unpack all components. Verify that all parts are present and undamaged. The package should include the main unit, hot air gun handle, power cord, and a set of nozzles.

4.2 Nozzle Installation

The hot air gun comes with 6 nozzles of different specifications. To install a nozzle:

  1. Ensure the hot air gun is cool and powered off.
  2. Select the appropriate nozzle for your application.
  3. Gently push the nozzle onto the end of the hot air gun handle until it is securely in place.
  4. To remove, simply pull the nozzle off.

4.3 Power Connection

Connect the power cord to the main unit and then to a suitable power outlet according to your region's voltage requirements (110V or 220V). Ensure the power switch on the unit is in the 'OFF' position before connecting to power.

5. Operating Instructions

5.1 Control Panel Overview

Diagram of AIFEN F4 control panel with labels for Temp Display, Air Flow Display, Temp Adjust, Temperature Unit Display, Power Switch, Hot Air, Air Flow Adjust, Handle, Memory / Preset Buttons.
Detailed view of the AIFEN F4 control panel.
  • Temp Display: Shows the current or set temperature.
  • Air Flow Display: Shows the current or set airflow level.
  • Temp Adjust (▲/▼): Buttons to increase or decrease temperature.
  • Air Flow Adjust (▲/▼): Buttons to increase or decrease airflow.
  • Power Switch: Turns the unit on/off.
  • CH1-CH4 Buttons: Memory/Preset buttons for storing and recalling settings.

5.2 Temperature Setting

The temperature range is 100-500°C (212-932°F).

  • Heating: Press the "TEMP ▲" button once to increase the set temperature by 1°C. The temperature display will show the set temperature. To rapidly increase the temperature, press and hold the "TEMP ▲" button until the desired temperature is reached, then release.
  • Cooling: Press the "TEMP ▼" button once to lower the set temperature by 1°C. The temperature display will show the set temperature. To rapidly decrease the temperature, press and hold the "TEMP ▼" button until the desired temperature is reached, then release.

5.3 Airflow Setting

The airflow range is 1-160 levels.

  • Increase Airflow: Press the "AIR ▲" button once to increase the airflow by one level. The airflow display will show the set airflow level. To rapidly increase the airflow, press and hold the "AIR ▲" button until the desired level is reached, then release.
  • Decrease Airflow: Press the "AIR ▼" button once to decrease the airflow by one level. The airflow display will show the set airflow level. To rapidly decrease the airflow, press and hold the "AIR ▼" button until the desired level is reached, then release.

5.4 Memory/Storage Keys (CH1-CH4)

  • Storing Settings: After setting the desired temperature and airflow, select the channel (CH1, CH2, CH3, or CH4) where you want to save the settings. Press and hold the corresponding CH button for at least one second to save the current parameters to that channel.
  • Recalling Settings: To recall saved settings, briefly press the desired CH button (less than 1 second). The unit will load the stored temperature and airflow settings for that channel.

5.5 Sleep Mode Airflow Setting

In working mode, press and hold CH1 and CH2 simultaneously to enter the sleep airflow setting. Use the airflow buttons (AIR ▲/▼) to set the sleep airflow (range: 60-160MAX). After setting, press and hold CH1 and CH2 simultaneously for three seconds to confirm and exit.

5.6 Sound Switch

In working mode, press and hold CH1 and CH3 simultaneously to toggle the buzzer sound on or off.

5.7 Temperature Unit Conversion

In working mode, press and hold CH2 and CH3 simultaneously to switch the temperature display between Celsius (°C) and Fahrenheit (°F).

5.8 Temperature Calibration

In working mode, press and hold the temperature rise (TEMP ▲) and temperature fall (TEMP ▼) buttons simultaneously to enter the temperature calibration interface. Use the temperature buttons to adjust the desired temperature (±99 degrees). After setting, briefly press CH3 to confirm, exit, and save the calibration.

5.9 Sleep Function

  • Entering Sleep: Place the hot air gun handle correctly on the handle frame. The system will automatically initiate large air volume cooling. When the display shows the temperature is less than 100°C, the system will enter sleep state, and the window will display "-----".
  • Waking from Sleep: If the handle is correctly placed on the handle frame, it cannot be awakened by pressing buttons. When the handle is removed from the handle frame, the system immediately enters the working state.

6. Maintenance

6.1 Regular Checks

Regularly check and maintain the station. DO NOT use it if it has damages, especially if the power cable or air gun handle wire is damaged.

6.2 Heating Element Replacement

Note: The replacement heating element should be replaced only after the unit has cooled down completely and is powered off.

  1. Loosen the handle anti-scalding sheath on the hot air gun handle and remove it from the handle.
  2. Unscrew the three screws that fix the steel pipe (which contains the heater element).
  3. Carefully remove the old heating element.
  4. Install the new heating element and reassemble the components in reverse order.

Important Note: The steel pipe of this product may show slight yellowing after aging at 500 degrees high temperature. This is a normal phenomenon due to aging color; please rest assured to use.

7. Troubleshooting

This section provides general troubleshooting tips. For complex issues, please contact customer support.

  • No Power: Ensure the power cord is securely connected and the power switch is on. Check the fuse.
  • No Heat/Insufficient Heat: Verify the temperature setting. Check if the heating element needs replacement (refer to Maintenance section). Ensure the air outlet is not blocked.
  • No Airflow/Weak Airflow: Check for blockages in the air outlet or hose. Verify the airflow setting.
  • Unit Not Entering Sleep Mode: Ensure the handle is correctly placed on the handle rack. The unit will only enter sleep mode when the temperature drops below 100°C.
  • Unit Not Waking Up: Remove the handle from the handle rack. If it's already off the rack and not working, check power and connections.

8. User Tips

  • Voltage Compatibility: The AIFEN F4 is available in both 110V and 220V versions. Always ensure you have the correct voltage model for your region to prevent damage and ensure proper operation. Check the product label or your order details for the specific voltage.
  • Nozzle Selection: Experiment with different nozzle sizes and shapes to find the most effective one for your specific soldering or desoldering task.
  • Pre-setting Channels: Utilize the CH1-CH4 memory functions to save frequently used temperature and airflow settings for different components or tasks, improving efficiency.

9. Frequently Asked Questions (FAQ)

Q: Is the AIFEN F4 Hot Air Gun 110V or 220V?
A: The AIFEN F4 Hot Air Gun is available in both 110V and 220V versions. Please check the product specifications or your order details to confirm the voltage of your specific unit. It is crucial to use the correct voltage for your region.

10. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the documentation provided at the time of purchase or contact the seller/manufacturer directly. Specific warranty terms and support channels may vary.

A PDF version of the user manual is available for download: User Manual (PDF)

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.