1. Product Overview
The JIKONG Smart Battery Management System (BMS) is a sophisticated protection board designed for large-capacity series lithium battery packs. It integrates essential functions such as voltage acquisition, high-current active balancing, overcharge/overdischarge/overcurrent/overtemperature protection, coulomb metering, Bluetooth communication, and optional GPS remote capabilities. This BMS is compatible with various battery chemistries, including Lithium Iron Phosphate (LiFePO4) and Ternary Lithium batteries.
The protection board utilizes energy transfer active balancing technology, capable of achieving a continuous balancing current of 0.6A. This high-current active equalization ensures optimal battery consistency, extends battery range, and prolongs battery life by delaying aging.
A dedicated mobile application (APP) is available for both Android and iOS operating systems. The APP connects to the BMS via Bluetooth, allowing users to monitor battery status, modify operating parameters, and control charge/discharge switches. The compact size and comprehensive functionality make this BMS suitable for a wide range of applications, including small sightseeing vehicles, mobility scooters, shared cars, high-power energy storage systems, base station backup power supplies, and solar power stations.
2. Functional Characteristics
The JIKONG BMS offers a robust set of features to ensure efficient and safe battery management:
- LED Bluetooth status indicator
- APP Bluetooth remote operation
- Battery capacity calculation
- High precision voltage acquisition (±3mV)
- High precision current acquisition
- Support information screen display
- Accurate time logging
- Support for optional communication interfaces: RS485, CAN, One-wire
- Support optional parallel function for battery packs
- Support optional alarm function
- Support optional heating function
- Support optional ACC detection function
- Support optional GPS communication
- Comprehensive protection functions: Charge overcurrent, Charge overvoltage, Charge overtemperature, Low temperature protection during charge, Discharge overcurrent, Discharge undervoltage, Discharge overtemperature, Short circuit protection.
3. Specifications
3.1 General Parameters
| Project | Argument | Unit |
|---|---|---|
| Supply voltage | 20-100 | V |
| Operating power consumption | <800 | mW |
| Operating temperature | -30-70 | °C |
| Maximum number of collection strings | 24 | String |
| Maximum balancing current | 0.6 | A |
| Maximum charging current | 80 | A |
| Maximum discharge current | 80 | A |
| Maximum instantaneous current | 150 | A |
| Maximum internal loop resistance | 0.9 | mΩ |
| Acquisition cycle | 1.5 | S |
| Differential pressure update cycle | 3 | S |
3.2 Default Parameters
| Parameter | Li-ion (Default) | LiFePO4 (Default) | LTO (Default) | Unit |
|---|---|---|---|---|
| Balancing initial voltage | 3 | 3 | 2 | V |
| Maximum balancing current | 0.6 | 0.6 | 0.6 | A |
| Unit overcharge voltage | 4.2 | 3.6 | 2.7 | V |
| Single overcharge protection recovery | 4.18 | 3.55 | 2.65 | V |
| Monomer undervoltage protection | 2.82 | 2.6 | 1.8 | V |
| Single undervoltage protection recovery | 2.85 | 2.65 | 1.85 | V |
| Automatic shutdown voltage | 2.8 | 2.5 | 1.7 | V |
| SOC-0% voltage | 2.9 | 2.6 | 1.85 | V |
| SOC-100% voltage | 4.18 | 3.5 | 2.65 | V |
| Trigger balancing differential pressure | 0.01 | 0.01 | 0.01 | V |
| Charging overcurrent protection delay | 30 | 30 | 30 | S |
| Charging overcurrent protection release time | 60 | 60 | 60 | S |
| Discharge overcurrent protection delay | 300 | 300 | 300 | S |
| Discharge overcurrent protection release time | 60 | 60 | 60 | S |
| Short-circuit protection delay | 5 | 5 | 5 | µS |
| Charging overtemperature protection temperature | 70 | 70 | 70 | °C |
| Charging overtemperature restore temperature | 60 | 60 | 60 | °C |
| Discharge overtemperature protection temperature | 70 | 70 | 70 | °C |
| Discharge overtemperature recovery temperature | 60 | 60 | 60 | °C |
| Charging low temperature protection temperature | -20 | -20 | -20 | °C |
| Charging low temperature to restore temperature | -10 | -10 | -10 | °C |
| MOS Overtemperature protection temperature | 100 | 100 | 100 | °C |
| MOS Overtemperature protection recovery temperature | 80 | 80 | 80 | °C |
| Device address | 0 | 0 | 0 | / |
3.3 Dimensions
The dimensions of the JK-BD6AxxS-8PD series protection board are approximately 119.5mm (length) × 73mm (width) × 13.6mm (thickness).
The casing is made of aluminum alloy and adopts one-piece molding technology, providing superior heat dissipation with a high thermal conductivity of <300[W/(m-K)]. The aluminum shell surface is sprayed with a layer of graphite material for more uniform and balanced heat transfer.
4. Setup and Installation
4.1 Packing List
Before installation, please verify that all components are present in the package:
- BMS unit: 1
- NTC (Temperature Sensor) (long 400mm): 1
- Balance Wires (long 750mm): 1
- Switch (long 500mm): 1
- M6 screws: 2
- Packing box: 1
4.2 Product Appearance and Connectors
The BMS features various interfaces for connection to the battery pack, external modules, and display units. Key interfaces include:
- Balance with Acquisition Interface (P1, HY2.0-15AW): Connects to the individual cell voltage taps (B-, B1-B14).
- Balance with Acquisition Interface (P2, HY2.0-11AW): Connects to the individual cell voltage taps (B15-B24).
- Temperature Interface (P3, HY2.0-4AW): For connecting NTC temperature sensors (T1A, T1B, T2A, T2B).
- Optional Temperature Interface (P4, HY2.0-4AW): For additional external NTC temperature sensors (T3A, T3B, T4A, T4B).
- UART Interface (P5, 1.25T-4PWT): For communication (RX, TX) and optional GPS module (VGPS).
- Buzzer Interface (P6, A1254WF-2A): For optional alarm buzzer (GND, VCC).
- Communication Interface (P7, A1254WF-4A): For optional CAN communication (CAN L, CAN H).
- Display Interface (P8, A1254WF-6A): For connecting an optional display screen (GND, B, A, VCC) and RS485 communication (RS485 A, RS485 B).
- Parallel Interface (P9, A1254WF-3A): For optional battery pack parallel function (P-status, P-EN, GND).
- ACC Interface (P10, A1254WF-5A): For optional ACC detection (C_Detect-, C_Detect+, ACC-, ACC+).
- Bluetooth Connection Indicator (D1): Steady on when connected, blinking when disconnected.
- Heater Element Negative Electrode (HT-): For optional heating function.
- External Load/Charger Negative Terminal (P-)
- Negative Battery Terminal (B-)
4.3 Installation Method (Wiring)
The JK-BD6AxxS-8PD series protection board is suitable for 7-24 series lithium battery packs. The specific wiring method varies depending on the number of cells in the battery pack. Always ensure correct connections to prevent damage.
- Pre-installation Check: Before powering on the protection board, double-check that the balance cables are correctly connected and that the P- and B- terminals are properly wired. Ensure the protection board is securely fixed to the battery pack.
- Balance Cable Connection: Connect the balance wires to the corresponding cell voltage taps (B-, B1, B2, ..., B24) as per the wiring diagram.
- Main Power Connections: Connect the main negative terminal of the battery pack to B- on the BMS. Connect the main positive terminal of the battery pack to B+ (not explicitly shown on the board but implied by the wiring diagram). Connect the load/charger negative terminal to P- on the BMS.
- Optional Module Connections: Connect any optional modules (NTC sensors, display screen, communication modules, etc.) to their respective interfaces on the BMS.
4.4 Device Activation
The protection board does not have a physical power-on switch. It is designed for charging activation. After the battery assembly is complete, connect a charger (with voltage 2V higher than the battery voltage) to activate the BMS.
Alternatively, the BMS can be activated via a key switch or a display screen. If you have an optional display screen and button, simply connect the cable to the display interface and press the button to activate the device.
5. Operating Instructions
5.1 APP Installation and Operation
The mobile APP is essential for monitoring and configuring your JIKONG BMS. You can download the APP by scanning the QR code below. Android Version 7 or higher is required.
Once installed, connect the APP to the BMS via Bluetooth. The APP provides a comprehensive interface to:
- Monitor real-time battery status (voltage, current, temperature, SOC).
- Modify various operating parameters (e.g., protection thresholds, balancing settings).
- Control charge and discharge switches.
- Access detailed data logs.
5.2 Active Equalization
Active equalization transfers energy from higher-voltage cells to lower-voltage cells to maintain battery consistency. In the APP's parameter settings, you can adjust the balance trigger pressure difference (mV). When the voltage difference between any two cells exceeds this set value, balancing will automatically activate. The default continuous balance current is 0.6A, which can be adjusted based on your battery capacity. If balancing is not required, it can be turned off in the BMS control page of the APP.
5.3 Optional Functions
- UART Function: The reserved UART interface supports optional GPS modules for battery positioning.
- Display Screen Function: An optional display screen can be connected to view battery information directly without the APP.
- Heating Function: For low-temperature environments, an optional heating function (using a resistance heater or heating film) can be enabled to maintain battery activity. A temperature control switch (45°C to 65°C normally closed type) is recommended in series for secondary protection.
- Battery Parallel Function: This optional function supports parallel connection of battery packs. It requires synchronous use with parallel modules and disabling the "charging current limiting" function in the APP.
- ACC Detection Function: This function enables discharge. It can be activated by applying 12V-70V between ACC+ and ACC-, or by short-circuiting them. A charger detection interface (C_detect+/C_detect-) is also reserved for enabling charging.
- Communication Functions (CAN, RS485, One-Wire): These optional interfaces allow for advanced communication with other systems. Refer to the JIKONG Protection Board communication protocol document for specific details on setting addresses and protocols.
6. Maintenance and Protection
The JIKONG BMS is equipped with various protection mechanisms to ensure the longevity and safety of your battery pack. These protections automatically trigger and recover under specific conditions:
- Charge Overvoltage Protection & Recovery: If any cell voltage exceeds the set overvoltage protection, charging will stop. It resumes when all cell voltages drop below the recovery voltage.
- Discharge Undervoltage Protection & Recovery: If any cell voltage drops below the set undervoltage protection, discharge will stop. It resumes when all cell voltages rise above the recovery voltage. The BMS will automatically shut down if any cell voltage falls below the automatic shutdown voltage.
- Charge Overcurrent Protection & Recovery: If charging current exceeds the continuous charging current for a set delay, charging stops. It resumes after the overcurrent release time.
- Discharge Overcurrent Protection & Recovery: If discharge current exceeds the continuous discharge current for a set delay, discharge stops. It resumes after the overcurrent release time. (Note: Max continuous discharge current cannot exceed 80A).
- Overtemperature Protection & Recovery: If the BMS detects temperatures above the set charge or discharge overtemperature thresholds, the respective operation (charging or discharging) will stop. It resumes when temperatures fall below the recovery thresholds.
- Low Temperature Protection & Recovery: If the BMS detects temperatures below the set charging low temperature threshold, charging will stop. It resumes when temperatures rise above the recovery threshold. For extremely cold regions, using the optional heating function is recommended.
- Short Circuit Protection & Recovery: The BMS features standard short circuit protection. While the trigger current is not user-adjustable, the short circuit protection delay (µS) and recovery time (S) can be set in the APP. If a short circuit occurs, the BMS will stop the operation and resume after the recovery time. Increasing the delay can help prevent false triggers from high instantaneous currents during startup with capacitive loads.
6.1 Intelligent Sleep
The intelligent sleep function, enabled or disabled via the APP, reduces the BMS's self-consumption when in standby (charging/discharging current less than 1A for 26 consecutive hours). The BMS can be reactivated by pressing a button (if equipped) or by connecting a charger.
7. Troubleshooting
- Alarm Function: The BMS supports an optional alarm function. When security risks such as overtemperature, overcharge, or overdischarge are detected, the BMS will provide an external alarm alert.
- Emergency Switch: In case of issues like overtemperature, overdischarge, overcharge, or a dropped cell string during normal use, activating the emergency switch in the APP's BMS control page will enable both charging and discharging for 30 minutes. This provides a temporary operational window, even if a single cell reaches the automatic shutdown voltage, to prevent critical situations.
- Protection Triggers: If the BMS triggers any of the protection mechanisms (e.g., overvoltage, overcurrent), refer to the specific protection section in this manual (Section 6) for details on the conditions that trigger the protection and how it recovers. Adjusting parameters in the APP may be necessary for persistent issues.
- Connection Issues: If the BMS does not power on or behaves abnormally, re-check all balance cable connections and the P-/B- main power connections. Ensure the board is securely mounted.
8. User Tips
- Initial Setup Verification: Always ensure all balance cable connections and main power connections (P- and B-) are correct and secure before applying power to the BMS. Incorrect wiring can lead to severe damage.
- APP Utilization: Make full use of the mobile APP for real-time monitoring of battery parameters and for fine-tuning protection thresholds and balancing settings to match your specific battery pack and application.
- Cold Weather Operation: If operating in extremely cold environments, consider installing and enabling the optional heating function to maintain optimal battery performance and prevent low-temperature charging issues.
- Parameter Adjustment: When adjusting parameters in the APP, proceed with caution and understand the implications of each setting to avoid unintended behavior or damage to the battery.
9. Warranty and Support
For detailed warranty information, technical support, or service inquiries, please refer to the official JIKONG documentation or contact your vendor. A comprehensive user manual in PDF format is available for download, providing in-depth instructions and specifications.
You can access the official user manual PDF here: JIKONG BMS User Manual (PDF)