1. Important Safety Instructions
! Warning: It is essential to read, understand, and adhere to all safety instructions provided in this document. Failure to comply with safety regulations may result in property damage or personal injury.
1.1 Basic Guidelines
- Before using the equipment, carefully review all relevant sections of the device, battery, and instruction manual for all guidance and warning signs.
- Caution: To reduce the risk of injury, only charge deep-cycle lead-acid rechargeable batteries. Other types of batteries may rupture, causing personal harm.
- This product does not contain user-serviceable parts. Do not disassemble the equipment. When maintenance or cleaning is required, take it to a qualified service center. Improper reassembly may pose risks of short-circuiting and fire. If any panel displays a malfunction, do not remove the front panel or operate the product. All operating procedures must be performed by trained professionals.
- To reduce the risk of electric shock, disconnect all wiring before performing any maintenance or cleaning. Simply turning off the main unit does not eliminate the risk of electric shock.
- Caution: Only qualified personnel should assemble the equipment with the battery.
- Charging frozen batteries is prohibited.
- Exercise extreme caution when using metal tools or placing them around the battery. Dropping tools can generate sparks or cause unpredictable risks such as short-circuiting the battery or other electronic components, potentially leading to explosions.
- When disconnecting AC or DC terminals, strictly follow the installation steps as outlined in the instruction manual's installation section.
- Before using this product, read the provided instructions to familiarize yourself with safety features and operating instructions. This product is designed and tested according to international standards. The equipment must be used exclusively for its intended purpose.
1.2 Installation Safety
- Do not use this product in areas where there is a risk of gas or dust explosions. Prior to use, consult with the battery manufacturer's relevant literature to ascertain the compatibility of this product with the battery. Always adhere to the safety instructions provided by the battery manufacturer.
- This is a Safety Class I product (supplied with a protective grounding terminal). Uninterruptible protective grounding must be provided at the AC input and/or output terminals. Alternatively, the grounding point located externally on the product may be used. Whenever it is likely that the grounding protection has been damaged, the product must be turned off and secured against unintended operation.
- Grounding Instructions: The inverter/charger should be connected to a permanent grounding wire system to ensure full compliance with local requirements and regulations for installing the inverter. When grounding protection may have been compromised, the product must be shut down to prevent accidental electric shock.
- Ensure that the DC and AC input cables are fused and fitted with circuit breakers. Never replace a safety component with a different type. Always consult the manual to determine the correct component.
- To ensure optimal operation of the inverter/charger, adhere to the required specifications and select appropriate cable sizes, which are crucial for the correct operation of the inverter/charger.
- Before connecting to the mains power, ensure that the available power supply meets the parameters specified in the product manual.
- Do not short-circuit the AC output and DC input. Do not connect the mains power when the DC output is short-circuited.
- Ensure that the equipment is used in conditions compliant with standards. Do not operate the product in moist or dusty environments.
- Ensure there is sufficient clearance space around the product and check that ventilation holes are not blocked.
- Ensure that the required system voltage does not exceed the capacity of the product.
1.3 Transportation and Storage Safety
- Ensure that the power and battery cables are disconnected before storing or transporting the product.
- If the equipment is not in its original packaging during transportation, any transport damage is not the responsibility of the manufacturer.
- Store the product in a dry environment, with storage temperature between -20°C to 60°C.
- Refer to the battery manufacturer's manual for information on battery transportation, storage, charging, recharging, and disposal.
- Please follow these instructions diligently to ensure safe installation, operation, transportation, and storage of the product.
2. Product Overview
2.1 Features
- The POW-RELAB-SPLIT series low frequency solar inverter-charger integrated machines from PowMr are suitable for most residential and commercial scenarios, ensuring higher output stability and reliability.
- Dual AC outputs support single-phase 110V AC output or two-phase 220V AC output from a single inverter, easily powering split-phase equipment.
- Flexible energy deployment is achieved through three operating modes, ensuring stable operation of loads while maximizing the utilization of solar clean energy. The energy-saving mode minimizes equipment self-consumption losses.
- It combines pure sine wave inverter output with mains or generator bypass output functions, supporting solar charging and AC power charging. The output power and charging power can be prioritized according to actual application needs.
- It features a built-in AC output circuit breaker at the bottom, ensuring the safety and stability of the power supply to the load side.
- It features built-in multiple protection functions and precise alarm mechanisms, providing comprehensive protection for system safety and stability.
- External communication is supported via RS232 or RS485. BMS communication is supported to effectively monitor battery operation, optimize battery pack operation efficiency, and extend the lifespan of the entire battery pack.
2.2 System Basic Architecture
The inverter/charger can be integrated into a complete operational system with engine/mains power and photovoltaic modules. It can power various electrical appliances in residential or office environments.

Diagram: Basic system architecture showing PV panels, inverter, battery packs, and home appliances.
2.3 Product Appearance (10KW Model)
The following diagram illustrates the components and interfaces of the POW-RELAB 10KU-SPLIT model.

Image: Various views of the PowMr 10KW Inverter (front, back, angled).
| No. | Component | No. | Component |
|---|---|---|---|
| 1 | Power on/off switch | 8 | RS232 communication port |
| 2 | AC input | 9 | BMS/RS485 communication port |
| 3 | AC output | 10 | Dry contact |
| 4 | Communication port | 11 | Battery terminal negative |
| 5 | PV input | 12 | Battery terminal positive |
| 6 | Battery input | 13 | Fan |
| 7 | Input breaker |
3. Setup and Installation
3.1 Unboxing and Inspection
Before assembly, inspect the unit to ensure that the items in the packaging are undamaged. Inside the package, you will find:
- Inverter device x1
- Instruction manual x1
- Battery fuse x1
- Installation screws (1 set)
3.2 Installation Tools
Prepare the following tools before installation:
- General Tools: Multimeter, Protective gloves, Insulated safety shoes, Protective clothing, Safety goggles, Antistatic wrist strap.
- Installation Tools: Electric screwdriver, Socket wrench, Wire stripper, Phillips screwdriver (M4/M6), Electric drill, Hammer.
3.3 Equipment Installation
Consider the following points for selecting an installation location:
- Do not install the inverter on combustible building materials.
- Install on a solid surface.
- Position the inverter at eye level for easy viewing of the LCD display.
- Maintain approximately 20cm spacing on each side and approximately 50cm spacing above and below the device for proper air circulation and heat dissipation.
- Ensure ambient temperature remains between 0°C to 55°C for optimal operation.
- It is recommended to install the device vertically against the wall.
- Ensure other objects maintain sufficient distance from the inverter surface to ensure adequate heat dissipation and provide enough space for wiring removal.
! Suitable for installation on concrete or other non-combustible walls.
Secure the device in place using two screws, preferably M4 or M5 screws.
3.4 Wiring Preparation
Loosen the fixed screws of the wiring terminal cover plate and remove the cover plate.
3.5 Cable Size and Circuit Breaker Specifications
Ensure correct cable sizing and circuit breaker selection for safety and optimal performance.
PV Input
Configuration depends on actual PV array power and voltage. Wire size: PV power / PV voltage / 5. Circuit breaker: PV power / PV voltage.
AC Input
| Model | Cable Diameter (110V) | Circuit Breaker Spec (110V) |
|---|---|---|
| 10KW | 25mm² | ≥125A |
Battery
| Model | Cable Diameter | Circuit Breaker Spec |
|---|---|---|
| 10KW | 50mm²/25mm² x2 | 250A |
AC Output
| Model | Cable Diameter (220V) | Cable Diameter (110V) | Circuit Breaker Spec (220V) | Circuit Breaker Spec (110V) |
|---|---|---|---|---|
| 10KW | 10mm² | 25mm² | ≥46A | ≥91A |
3.6 AC Input & Output Connection (5KW/10KW Models)
Connect live, neutral, and ground wires to respective terminals. Install circuit breaker protection. Ensure proper grounding and secure all cables.

Diagram: AC Wiring for POW-RELAB-SPLIT Series. Connect corresponding voltage loads according to the diagram. Mode 1 (110V input/output), Mode 2 (110V input/output), Mode 3 (110V input, 220V output), Mode 4 (110V input, 110V/220V output). L=Live Wire (Red), N=Neutral Wire (Blue), Ground Wire (Green).
! DANGER: Before connecting AC input/output, open the circuit breaker. Do not operate while power is on. Use required cable sizes; thin/poor-quality cables pose a serious safety hazard.
3.7 Battery Connection (5KW/10KW Models)
Connect positive and negative battery terminals as per the diagram. Install a circuit breaker meeting specifications on the battery circuit.
! ATTENTION: POW-RELAB series inverters come standard with a fuse device for the battery circuit. Use according to actual needs.
! DANGER: Before connecting the battery, disconnect the circuit breaker. Do not operate while power is on. Ensure positive and negative terminals are correctly connected and not reversed. Use required cable sizes.
3.8 Photovoltaic Connection (5KW/10KW Models)
Connect the photovoltaic array as per the diagram. Install a circuit breaker meeting specifications.
! DANGER: Before connecting PV panels, open the circuit breaker. Do not operate while power is on. Ensure open-circuit voltage of connected PV modules in series does not exceed 245V, or the inverter may be damaged.
3.8.1 Selecting and Configuring Photovoltaic Panels
Obtain parameters from PV panel specifications (Pmax, Voc, Isc, Vpm, Ipm). Panels can be connected in series or parallel to meet inverter input range.
- Series Connection: Total voltage = sum of individual voltages; current remains the same.
- Parallel Connection: Total voltage remains the same; total current = sum of individual currents.
3.9 Communication Connection
3.9.1 BMS Communication
The BMS communication interface uses an RJ45 connector. Pin definitions:
- PIN1: 485B
- PIN2: 485A
- PIN3/4/5/6/7/8: NC (Not Connected)
3.9.2 Host Computer Communication
Use the supplied communication cable to connect to the inverter and PC. Install monitoring software on the computer.
3.9.3 Dry Contact Function
Dry contacts control the AC input switch for battery charging based on device status and battery voltage. Refer to the manual for detailed conditions and port states (NC&C, NO&C).
3.10 Final Installation
After confirming all connections are accurate and tightened, reinstall the port protective cover onto the device.
4. Operating Instructions
4.1 Starting the Inverter
After closing the circuit breaker of the battery line, start the inverter using the boat-shaped switch at the bottom. Once the inverter starts up normally, sequentially close the circuit breakers of the photovoltaic input, AC input, and AC output lines.
4.2 Operation Panel Introduction
The operation panel includes an LCD Display, LED Indicators, and Function Keys (ESC, UP, DOWN, ENTER).
LED Indicators:
- AC/INV (Green): Solid On = Utility power (Line mode); Flashing = Battery PV power (Battery mode).
- CHG (Yellow): Solid On = Battery fully charged; Flashing = Battery charging.
- FAULT (Red): Solid On = Inverter in fault warning status.
Function Keys:
- ESC: To exit setting mode.
- UP: To go to next selection.
- DOWN: To go to previous selection.
- ENTER: To confirm selection in setting mode or enter setting mode.
4.3 Display Panel Introduction
The LCD displays various information including input power (AC, PV, Battery), output information (voltage, current, load), configuration, and fault codes. Icons indicate AC input, PV input, battery status, load level, mains connection, bypass, rectifier, inverter circuits, and alarm buzzer status.
4.4 Operating Modes
- AC Mode: Product fully functional, green LED "AC In" lights up.
- Inverter Mode: When electricity or generator power is disconnected, it transfers to inverter mode (<10ms). Green LED "Inverter" lights up.
- Charging Mode: When electricity or generator power recovers, green LED "AC IN" comes up, and yellow "Charge" light blinks. Solid yellow when fully charged.
- Alarm Mode: When battery discharge approaches cutoff voltage, red Alarm light starts with continuous beeping. Stays until battery reaches low voltage cut-off and shuts down.
- Bypass Mode: Product's power button is off, but electricity or generator is on, output to load while charging battery. No output if power button is off and no electricity/generator.
- Saver Mode: If no grid supply, AC output is not supplied until a load >15 watts is connected. Automatically detects connected load every 25 seconds.
4.5 LCD Screen Settings
To enter settings mode, long press ENTER for 10 seconds. Use UP/DOWN to select parameters, ENTER to confirm, then UP/DOWN to change values, and ENTER again to save. ESC to exit.
Key configurable parameters include:
- Grid Input Voltage Range (UPS/APL)
- Grid Frequency Range (LO/HI)
- Operating Mode (UTI - Grid Priority, SOL - Solar Priority, SBU - Inverter Priority)
- Charging Mode (CUT - Grid Priority, CSO - Solar Priority, OSO - Solar Charging Only)
- Grid Charging Current Percentage
- Solar Charging Current Percentage
- Boost Charging Voltage (CV)
- Float Charging Voltage
- Battery Discharge Cutoff Shutdown Voltage
- Enable/Exit Grid Charging Voltage
- Inverter Output Voltage (110V/220V)
- Grid Detection Speed (HI/IDE/LO)
- Inverter Output Frequency (50Hz/60Hz)
- Fault Restart Switch (TE - Enabled, TD - Disabled)
- Backlight Control (LON - Always On, LOF - Always Off, LOD - Delayed Off)
- Buzzer Control (AON - Enabled, AOF - Disabled)
- Battery Under Voltage Alarm Switch (ON/OFF)
- Load Limitation (ON/OFF)
- Baud Rate (2400, 4800, 9600)
- Battery Type (SEL, GEL, FLD, USER, LiCoMnNiO2, LiFePO4)
- BMS Function Switch (ON/OFF)
- Undervoltage Shutdown SOC, Switch to Utility Mode SOC, Switch to Inverter Mode SOC, Restart SOC
- Low Voltage Alarm Voltage Setting
- Lithium battery protocol type
- ECO Energy Saving Mode (ON/OFF)
5. System Maintenance
To maintain optimal and long-term performance, conduct the following checks twice a year:
- Ensure airflow around the machine is unobstructed; clear dirt/debris from the heat sink.
- Inspect all exposed wires for insulation damage (sunlight, friction, dryness, insects, rodents); repair/replace as necessary.
- Verify indicators and displays are consistent with operation; take corrective action for faults/errors.
- Inspect terminal connections for corrosion, insulation damage, high temperature, burning/discoloration; tighten terminal screws.
- Check for dirt, nesting insects, and corrosion; clean as required.
- If surge protectors have failed, promptly replace them to prevent damage from lightning strikes.
5.1 Damages Not Covered by Company's Liability
- Improper use or use in inappropriate locations.
- Open-circuit voltage of PV modules exceeding maximum allowable voltage.
- Operating environment temperatures exceeding limited range.
- Unauthorized disassembly and repair.
- Force majeure damage (transportation/handling).
6. Troubleshooting
6.1 Alarms
The inverter displays various alarm codes for different issues. Refer to the manual's detailed table for specific alarm codes (e.g., Device Communication Connection Failure, PV temperature sensor abnormal, Overload, High Battery Voltage, BMS-Communication Anomaly, etc.) and their descriptions.
6.2 Alarm Events
- Low battery: Audible alarm - Beeping for 1 second.
- Overload: Audible alarm - Continuous beeping.
- Fault: Audible alarm - Continuous beeping.
6.3 Common Issues and Solutions
| Issue | Possible Causes | Solution |
|---|---|---|
| Inverter fails to operate properly after startup | Battery terminals not tightened | Tighten the battery terminals. |
| Sparking observed at inverter terminals | Reverse polarity connection | Inspect the polarity of the terminals and reconnect them correctly. |
| No output from the inverter | Output terminal rows not tightened | Remove the port cover and tighten the corresponding terminal rows. |
| Inverter unable to charge | Input voltage less than 150Vac | Increase the voltage using a stabilizer. |
| Continuous alarm from inverter buzzer during load operation | Inverter overload | Check the load and reduce high-power loads. |
7. Specifications
7.1 Utility Mode Parameters
| Parameter | Specification |
|---|---|
| Input Voltage Waveform | Pure Sine Wave |
| Nominal Input Voltage | 110Vac |
| AC Input Voltage Range | 77~132Vac |
| Nominal Input Frequency | 50Hz / 60Hz (Auto Detection) |
| Transfer Time | <8ms |
| Input Protection | Circuit Breaker |
| Output Protection | Circuit Breaker |
7.2 Inverter Mode Parameters
| Parameter | Specification |
|---|---|
| Rated Output Power | 10000W |
| Output Voltage Waveform | Pure Sine Wave |
| Nominal Output Voltage | 110Vac(N-L1/N-L2) / 220Vac(L1-L2) |
| Output Frequency | 50Hz / 60Hz |
| Peak Power | 30000W |
| Efficiency | >98% |
| Bypass Mode | Integrated |
| Eco Mode | Integrated |
| Nominal DC Input Voltage | 48Vdc |
7.3 Charging Mode Parameters
| Parameter | Specification |
|---|---|
| Battery Type | SEL, GEL, FLD, AGM, LiCoMnNiO2, LiFePO4 |
| Battery Capacity | Up to 500Ah |
| Max. AC Charging Current | 105A |
| Max. PV Charging Current | 100A |
| Battery Charging Voltage | 54.8VDC |
| Battery Undervoltage Cutoff Voltage | 40V/42V |
| Battery Undervoltage Warning Voltage | Mild discharge: 46V; Loaded discharge: 46V @load < 20% / 44V @load < 50% / 42V @load ≥ 50% |
| Battery Undervoltage Recovery Voltage | Mild discharge: 48V; Loaded discharge: 48V @load < 20% / 46V @load < 50% / 44V @load ≥ 50% |
| Battery Undervoltage Shutdown Voltage | Mild discharge: 44V; Loaded discharge: 44V @load < 20% / 42V @load < 50% / 40V @load ≥ 50% |
| Battery Overvoltage Warning Voltage | 62.4V |
| Battery Overvoltage Recovery Voltage | 60V |
| Max. PV Array Power | 5400W |
| MPPT Input Voltage Range | 60~245Vdc |
| Max. PV Array Open Circuit Voltage | 245Vdc |
7.4 General Parameters
| Parameter | Specification |
|---|---|
| Operating temperature | -10°C to 50°C |
| Storage temperature | -20°C to 60°C |
| Humidity | Relative humidity from 0% to 95% (non-condensing) |
| Noise | < 45dB |
| Dimensions (LxWxH) | 545*400*200mm |
| Net weight | 50.7kg |
8. User Tips
- Ensure all wiring connections are tight and secure to prevent intermittent operation or faults.
- When setting up, double-check battery polarity to avoid damage to the inverter.
- For optimal performance, ensure the inverter is installed in a well-ventilated area with adequate clearance.
- Regularly monitor the LCD display for any alarm codes or unusual readings to address potential issues promptly.
9. Warranty and Support
9.1 Situations Not Covered by Warranty
- User-configured batteries.
- Equipment damage caused by operation not in accordance with the user manual.
- Machine damage caused by natural disasters such as fire, flood, etc.
- Products beyond the warranty period are subject to paid repair services.