1. Introduction

The JIKONG BMS (Battery Management System) is an intelligent protection board designed for large capacity series lithium battery packs. It integrates voltage acquisition, active current balancing, overcharge, over-discharge, over-current, over-temperature protection, coulomb meter, and Bluetooth communication functionalities. This BMS is compatible with various battery types including Li-ion, LiFePO4, and LTO batteries.

Utilizing energy transfer active balancing technology, the BMS achieves a continuous balancing current of 0.6A, ensuring battery consistency, extending range, and prolonging battery life. It supports mobile APP connectivity (Android and iOS) for real-time monitoring and parameter adjustment.

JIKONG BMS JK-BD6A20S4PD Overview

Figure 1.1: JIKONG BMS JK-BD6A20S4PD with key features: BT/Display, Battery BMS, 0.6A Balancing Current, 8S-20S Battery Strings, 40A Charge/Discharge, Li-ion/Lifepo4/LTO Battery Type.

2. Safety Information

  • Always ensure correct wiring polarity. Incorrect connections can damage the BMS and battery.
  • Do not short-circuit the battery terminals.
  • Handle the BMS with care to avoid physical damage.
  • Ensure proper insulation for all connections to prevent accidental contact.
  • Keep the BMS away from water, moisture, and extreme temperatures.
  • Installation should be performed by qualified personnel if you are unsure.

3. Package Contents

Please check the package for the following items:

  • 1 x JIKONG BMS Unit
  • 1 x Sampling Line (70cm long)
  • 1 x NTC Temperature Sensor (40cm long)
  • 1 x Switch (50cm long)
JIKONG BMS Packing List

Figure 3.1: Contents of the JIKONG BMS package.

4. Setup and Installation

4.1. Physical Installation

Before powering on the protection board, ensure that the balance cable is properly connected and that the P- (load/charger negative) and B- (battery negative) terminals are correctly wired. Verify that the protection board is securely fixed to the battery pack. Incorrect connections can lead to abnormal operation or damage.

4.2. Wiring Diagram

The JIKONG BMS JK-BD6A24S-4PD series protection board is suitable for 7-24 series lithium battery packs. The specific wiring method varies depending on the number of cells in your battery pack. Always refer to the detailed wiring diagram for your specific configuration.

JIKONG BMS Wiring Diagram Example

Figure 4.1: Example of BMS wiring connections. Connect the sampling lines (B1, B2...Bn) to each cell's positive terminal, B- to the battery pack negative, and P- to the load/charger negative. The NTC sensor should be placed on a battery cell for temperature monitoring.

4.3. Device Activation

The BMS does not have a physical power-on switch. It is designed for charger activation. After the battery assembly is complete, connect a charger (with voltage 2V higher than the battery voltage) to activate the BMS. Alternatively, if you have an optional light panel, you can activate the BMS by connecting the panel and pressing its button.

4.4. Mobile APP Installation

The JIKONG BMS features a mobile application for monitoring and control. To install the APP, scan the QR code provided in the product documentation or on the device itself. The APP requires Android Version 7 or higher, or a compatible iOS version.

JIKONG BMS Mobile App Interface

Figure 4.2: Screenshot of the JIKONG BMS mobile application interface showing real-time data.

5. Operating Instructions

5.1. Real-time Monitoring

Once activated, connect to the BMS via Bluetooth using the mobile APP. The APP displays real-time battery status, including total voltage, individual cell voltages, current, temperature, State of Charge (SOC), and protection status. You can view detailed information for each cell and overall pack health.

5.2. Active Balancing

The BMS employs active balancing to equalize cell voltages. When the voltage difference between any two cells exceeds a user-defined threshold (default 0.01V), the balancing function automatically activates, transferring energy from higher voltage cells to lower voltage cells. The default balancing current is 0.6A. This feature can be enabled or disabled via the APP.

Active Balancing Diagram

Figure 5.1: Illustration of active balancing, showing energy transfer between cells to achieve voltage equilibrium.

5.3. Protection Functions

The BMS provides comprehensive protection features:

  • Overcharge Protection: Disconnects charging when any cell voltage exceeds the set limit.
  • Over-discharge Protection: Disconnects discharge when any cell voltage drops below the set limit.
  • Overcurrent Protection (Charge/Discharge): Disconnects current flow if it exceeds the set limit for a specified duration.
  • Over-temperature Protection: Disconnects charge/discharge if battery temperature exceeds the set limit.
  • Low-temperature Protection: Disconnects charging if battery temperature drops below the set limit.
  • Short Circuit Protection: Immediately disconnects output in case of a short circuit.

All protection parameters can be configured and adjusted via the mobile APP to suit specific battery requirements.

5.4. LED Battery Level Display (Optional)

If an optional LED display panel is connected, it will indicate the battery's State of Charge (SOC). The display typically uses multiple LEDs to represent different charge levels (e.g., 0-9%, 10-19%, 20-39%, 40-59%, 60-79%, 80-100%).

5.5. Intelligent Sleep Mode

The BMS can enter an intelligent sleep mode to reduce self-consumption. If the charge/discharge current remains below 1A for 26 consecutive hours, the BMS will enter sleep mode. It can be reactivated by pressing a button (if available) or by connecting a charger.

5.6. Emergency Switch

In case of critical issues like severe over-temperature, over-discharge, or cell imbalance, an emergency switch function can be activated via the APP. This will force the BMS to allow charge/discharge for 30 minutes, providing a temporary operational window.

6. Maintenance

  • Regularly check all wiring connections for tightness and corrosion.
  • Keep the BMS clean and free from dust and debris.
  • Avoid exposing the BMS to direct sunlight or extreme heat for prolonged periods.
  • Periodically check for APP updates to ensure optimal performance and access to new features.
  • Monitor battery cell voltages via the APP to detect any long-term imbalances.

7. Troubleshooting

7.1. BMS Not Activating

  • Ensure all wiring (balance cables, B-, P-) is correct and secure.
  • Connect a charger to activate the BMS. The charger voltage must be at least 2V higher than the battery pack voltage.
  • Check if the battery pack voltage is within the operational range of the BMS.

7.2. APP Connection Issues

  • Ensure Bluetooth is enabled on your mobile device.
  • Make sure the BMS is powered on and within Bluetooth range.
  • Restart the APP and try reconnecting.
  • Check if your mobile device's operating system meets the APP's requirements.

7.3. BMS Shutting Down Unexpectedly

  • Check the APP for any active protection alerts (overcharge, over-discharge, overcurrent, over-temperature, short circuit).
  • Verify that the load current does not exceed the continuous discharge current limit.
  • Inspect battery cell voltages for any critically low or high cells triggering protection.

7.4. Balancing Not Working

  • Ensure the balancing function is enabled in the APP settings.
  • Check the set voltage difference threshold for balancing activation. Balancing only starts if the cell voltage difference exceeds this value.
  • Verify that all balance wires are correctly connected to each cell.

8. Specifications

8.1. General Parameters (JK-BD6A20S4PD)

ParameterValueUnit
Supply Voltage20-100V
Operational Power Consumption<800mW
Operating Temperature-30 to 70°C
Max. Collection Strings24Strings
Max. Balancing Current0.6A
Max. Charging Current40A
Max. Discharge Current40A
Max. Instantaneous Current80A
Internal Loop Resistance1.6mΩ
Dimensions (L×W×H)116.8×94.8×14.6mm
Weight325g

8.2. Default Protection Parameters (Example for Li-ion)

ParameterLi-ion DefaultUnit
Balancing Start Voltage3.0V
Single Cell Overcharge Voltage4.2V
Single Cell Overcharge Recovery4.18V
Single Cell Undervoltage Protection2.82V
Single Cell Undervoltage Recovery2.85V
Auto Shutdown Voltage2.8V
Trigger Balancing Differential Pressure0.01V
Charging Overcurrent Protection Delay30s
Discharge Overcurrent Protection Delay300s
Short-circuit Protection Delay5µs

9. User Tips

  • Initial Setup: Double-check all wiring connections before applying power to avoid damage.
  • APP Customization: Take advantage of the mobile APP to fine-tune protection parameters to match your specific battery chemistry and usage patterns.
  • Monitoring: Regularly use the APP to monitor individual cell voltages, especially after initial setup and during the first few charge/discharge cycles, to ensure proper balancing.
  • Firmware Updates: Check the manufacturer's website or APP for any available firmware updates to ensure optimal performance and security.

10. Warranty and Support

For warranty information, technical support, or service inquiries, please contact your original point of purchase or the JIKONG manufacturer directly. Refer to the official JIKONG website for the most up-to-date support resources and contact details.

A detailed user manual in PDF format is available for download from the manufacturer's website, which contains additional technical details and troubleshooting guides.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.