DATOUBOSS DT-48628S

Contents

DATOUBOSS DT-48628S LiFePO4 Solar Battery Pack User Manual

Model: DT-48628S

1. Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of your DATOUBOSS DT-48628S LiFePO4 Solar Battery Pack. Please read all instructions and precautions carefully before installation or use to ensure safe and efficient operation. Keep this manual for future reference.

Play video
Watch video online

Video 1: DATOUBOSS Factory Overview. This video provides a brief look into the manufacturing process and facilities.

DATOUBOSS DT-48628S LiFePO4 Solar Battery Pack with key features highlighted

Figure 1: DATOUBOSS DT-48628S LiFePO4 Solar Battery Pack. This image displays the main unit with its 32.15 kWh battery capacity, 51.2V nominal operating voltage, IP20 protection level, and >8000 cycle life.

2. Safety Instructions

2.1 Safety Warnings

  • Non-safe voltages are present inside the solar battery pack. Do not disassemble the unit privately.
  • For equipment failure or maintenance needs, contact professional maintenance personnel.

2.2 Precautions for Use

  1. Avoid immersing the product in water or exposing it to moisture.
  2. Do not charge the product near fire sources or in high-temperature environments. Avoid heat sources like heaters.
  3. If leakage or abnormal odor is detected, immediately move the product to a safe, open area.
  4. Use the designated charging cable. If replacement is needed, ensure it matches the original wire gauge.
  5. Pay attention to correct polarity during installation; do not connect in reverse.
  6. Do not connect the product directly to wall sockets or car cigarette lighter sockets.
  7. Do not place the product in fire or heat it.
  8. Avoid short-circuiting product terminals with wires or other metal objects.
  9. Do not transport or store the product with metal objects like necklaces or hairpins.
  10. Do not pierce the product with nails or sharp objects, or strike/step on it.
  11. Avoid impacts, throwing, or other mechanical shocks.
  12. Do not weld directly onto the product terminals.
  13. Do not disassemble the product by any method.
  14. Do not mix this product with other battery types (e.g., dry cells) or different capacities/models.
  15. If unused for over 3 months, perform recharging.

2.3 Abnormal Situations

  1. Leakage or Odor: Move to an open, safe area. If electrolyte contacts eyes, flush with water and seek medical attention.
  2. Overheating, Deformation, Discoloration: Stop use immediately. If charging/discharging, disconnect the product.
  3. Smoke or Fire: Ensure personal safety, move the product to a fireproof, open place (e.g., sand, metal container).

2.4 Environmental Tips

Discharged batteries should be recycled according to local regulations. Do not dispose of them improperly.

3. Package Contents

Inspect the unit upon receipt. Ensure there is no damage to the packaging. Verify that all the following items are included:

Diagram showing all items included in the product package

Figure 2: Package Contents. The image illustrates the solar battery pack, L-shaped wall brackets, expansion screws, M8 and M6 screws, positive and negative leads, host computer communication cable, and user manual.

No.ItemQuantity
1Solar Battery Pack1
2L-Shaped Wall Bracket2
3Expansion Screws2
4M8 x 20 mm Screws4
5M6 x 16 mm Screws2
6Positive and Negative Leads1
7Host Computer Communication Cable1
8User Manual1

4. Setup and Installation

4.1 Installation Location Selection

  • Do not install on flammable building materials.
  • Avoid harsh environments.
  • Ensure the installation surface is solid and reliable.

4.2 Environmental Requirements

  • Ambient Temperature: 0-55°C.
  • Clearance: Maintain sufficient spacing (at least 20 cm on sides, 50 cm above) for proper ventilation, cable routing, and maintenance.

4.3 Installation Tool List

ToolPurpose
Impact drillFor drilling holes to secure wall-mounted brackets.
Flathead screwdriverFor mounting the product's back panel.
Tape measureTo measure and position installation holes and confirm height.

4.4 Installation Steps

  1. Install L-Shaped Brackets: Attach one L-shaped wall bracket to each side of the product using the provided flat-head screws.
  2. Mount the Product: Align the screw holes on the L-shaped brackets with pre-marked positions on the wall. Use anchor bolts to securely fasten the product to the wall.

5. Operating Instructions

5.1 Function Introduction (Rear Panel)

Diagram of the rear panel connections and indicators

Figure 3: Rear Panel Connections and Indicators. This diagram labels the battery positive/negative terminals, dry contact, RS485, CAN, RS232 ports, mains switch, air switch, battery indicator, operation indicator, switch indicator lights, DIP address, reset switch, and alarm indicator.

No.FunctionalityDescription
1Switch Indicator LightsSwitch Status
2Reset switchReboot or shutdown when pressed
3DIP AddressParallel or communication address selection
4Dry contactNormally open or normally closed signal driven relay
5RS485For connecting inverters
6CANFor connecting inverters
7RS232For upper computer
8RS485-1 & RS485-2For upper computer or battery parallel
9Operation IndicatorOperational status
10Alarm IndicatorAlarms
11Battery indicatorBattery level indication
12Battery PositiveBattery Positive
13Battery NegativeBattery Negative
14Mains SwitchControl switch
15Air switchDisconnect input and output

5.2 LED Indicator Description

The unit features various LED indicators for status, SOC (State of Charge), and alarms. Refer to the detailed tables in the PDF manual (Page 8) for specific LED behaviors (ON/OFF, Flash patterns) corresponding to Power Off, Static state, Charging, and Discharging conditions.

5.3 Buzzer Action

  • Fault: 0.25S signal every 1 second.
  • Protection: 0.25S horn every 2 seconds (except overpressure/underpressure).
  • Alarm: 0.25S alarm every 3 seconds (except overpressure/underpressure).

5.4 Reset Switch

  • Sleep Mode: Press to activate protection board; LED lights for 0.5s.
  • Active Mode (Shutdown): Press for 3-6s; LED lights from min to max power for 0.5s, then system enters sleep mode.
  • Active Mode (Reset): Press for 6-10s and release to reset; LED reflects current power.

5.5 Mains Switch

  • Hibernation: Turning off the main switch energizes the protection board; LEDs light sequentially from LED1 for 0.5s.
  • Active: Turning off the main switch and waiting 1-3s puts the system into power-off state.

5.6 DIP Switch (Parallel Connection)

When connecting multiple battery packs in parallel (up to 15 units), use the DIP switch on the BMS to set unique addresses for each pack. Switches 5 and 6 are reserved and have no function. Refer to the PDF manual (Page 10) for the specific binary settings for each PACK ID (1-15).

5.7 Communication Functions & Parallel Wiring

Table of communication interface pin descriptions for RS485, CAN, RS232

Figure 4: Communication Interface Pin Descriptions. This table details the functional description and pin assignments for RS485-1, CAN1, RS232, and RS485 ports, including connections to host computers, inverters, and parallel communication.

The battery pack supports RS485, CAN, and RS232 communication protocols. Detailed pin descriptions for each interface are provided in Figure 4. For parallel wiring instructions, refer to the detailed diagrams in the PDF manual (Page 11), which illustrate how to connect multiple units (Master and Slave devices) using RS485-1 and RS485-2 ports for ADD-IN and ADD-OUT connections.

5.8 Display Description (LCD Touchscreen)

Image of the 5-inch LCD touchscreen display showing real-time battery status

Figure 5: LCD Touchscreen Display. This image shows the real-time monitoring interface, displaying voltage, current, capacity, cell voltage, cell temperature, and BMS status.

The 5-inch LCD touchscreen provides real-time monitoring and control. Upon power-on, the system initializes and displays the main interface. This interface shows key operating parameters like SOC, Voltage, Current, Capacity, Cell Volt, Cell Temp, Operating Mode, and Status Indicator Light. All function menus are accessed via buttons on this interface:

  • Button 1: Slave Setting
  • Button 2: Communication Setting: Configure CAN and RS485 parameters for inverters/computers. The system performs communication diagnosis.
  • Button 3: System Setting: Access language switching, screen parameter adjustment (brightness, backlight timeout), and view equipment version information.
  • Button 4: Login / Parameter Setting: For authorized personnel (password 666888) to view/modify core battery parameters (SOC, Rated Capacity, Full Capacity, Max Charge/Discharge Voltage/Current).

6. Specifications

Detailed product specifications table

Figure 6: Product Specifications. This table provides a comprehensive overview of the battery's electrical, protection, and physical characteristics.

ParameterValue
Total Energy32.15 kWh
Internal Resistance≤13.9mΩ
Single Battery Capacity628Ah
Nominal Operating Voltage51.2V
Standard Input Current300A
Standard Output Current300A
Overpressure Protection58.4V
Overcharge Protection Recovery54.0V
Over-discharge Protection43.2V
Over-discharge Protection Recovery46.4V
High-temperature Charging Protection55°C
High-temperature Charging Recovery50°C
Low-temperature Charging Protection0°C
Low-temperature Charging Recovery5°C
High-temperature Discharge Protection55°C
High-temperature Discharge Recovery50°C
Low-temperature Discharge Protection-20°C
Low-temperature Discharge Recovery-15°C
Charge Overcurrent Protection325A/2000ms
Discharge Overcurrent Protection 1325A/2000ms
Discharge Overcurrent Protection 2360A/200ms
Short Circuit Protection2000A/400us (via load removal and charge disconnection)
Power Delivery Rate40% to 60%
EqualizationPassive balancing
Power Consumption when Off≤300μΑ
Cycle Life≥8000 Cycle, 70% SOH 25°C; ≥3000 Cycle, 70% SOH 45°C
Protection LevelIP20
Communication ProtocolsRS232, RS485, CAN
Dimensions (L×W×H)500×480×1005 mm
Weight≤240 kg

7. Maintenance

To ensure optimal performance and longevity of your DATOUBOSS solar battery pack, regular maintenance is recommended:

  • Visual Inspection: Periodically inspect the unit for any signs of physical damage, loose connections, or corrosion.
  • Ventilation: Ensure that the area around the battery pack remains clear and free from obstructions to allow for proper airflow and heat dissipation.
  • Cleaning: Keep the exterior of the unit clean and free of dust. Use a dry, soft cloth for cleaning. Do not use abrasive cleaners or solvents.
  • Firmware Updates: If available, follow manufacturer guidelines for any firmware updates to ensure the system operates with the latest features and optimizations.

8. Troubleshooting

For most operational issues, refer to the LED Indicator Description (Section 5.2) and the Buzzer Action (Section 5.3) for fault codes and their meanings. This will help identify the nature of the problem.

  • No Power: Check the mains switch and air switch. Ensure all connections are secure.
  • Communication Issues: Verify wiring for RS485, CAN, and RS232. Check baud rates and address configurations in the display settings (Section 5.8, Button 2).
  • Over-temperature/Under-temperature: Ensure the unit is operating within the specified ambient temperature range (0-55°C) and that ventilation is not obstructed.
  • Persistent Issues: If problems persist after consulting the LED indicators and performing basic checks, contact professional maintenance personnel.

9. User Tips

Based on general usage patterns for similar energy storage systems:

  • Optimal Placement: Choose a cool, dry, and well-ventilated area for installation to maximize battery life and efficiency.
  • Regular Monitoring: Periodically check the LCD touchscreen for system status and performance metrics to ensure everything is operating as expected.
  • Parallel Expansion: If you plan to expand your energy storage capacity, ensure proper DIP switch configuration for each additional battery pack to avoid communication conflicts.

10. Warranty and Support

10.1 Warranty Description

Please read the instructions carefully and keep them in a safe place. This product will be repaired if it malfunctions during the warranty period for normal use in accordance with the operating instructions. Replaced parts become the property of DATOUBOSS.

Conditions Not Covered by Free Repair:

  • Damage due to non-compliance with manual instructions, maintenance, or use of non-original parts.
  • Failure/damage from improper storage (e.g., not recharging for long periods).
  • Failure/damage from using power supply/load equipment outside specified voltage range.
  • Failure/damage from private repair, dismantling, or modification.
  • Damage to surface coating and exterior.
  • Damage to product outer packaging and accessories.
  • Torn, altered, or unrecognizable product labels, seals, and serial numbers (SN).
  • Failure/damage due to force majeure (natural disasters, social events).

This manual is for use only in the specified sales area; final interpretation rights belong to DATOUBOSS. Keep this manual safe. If the distributor's name is not on the warranty card, provide proof of purchase (receipt, invoice, order number, screenshot) from your dealer or online store.

10.2 Reimbursable Service Warranty

If the product does not meet warranty conditions, repair costs will be charged based on parts and labor. A repair quote will be provided for your approval and payment before services are rendered.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.