1. Introduction
The Aideepen LCR-MF10 Multi-function Tester is a versatile electronic component testing device designed for hobbyists and professionals. It features a high-definition TFT color screen display (160x128 graphic display) for intuitive visualization of measurement data. This tester supports automatic detection and measurement of a wide range of components including NPN/PNP bipolar transistors, N-channel/P-channel MOSFETs, JFETs, diodes (including double diodes and Zener diodes), N and P-IGBTs, resistors, inductors, capacitors, thyristors, triacs, and batteries (0.2-40V).
Key features include upgrade anti-burn protection, automatic calibration upon startup, portable Type-C charging with a built-in rechargeable lithium battery, and infrared decoding waveform display for Hitachi IR encoding.

2. Safety Warnings
- Always ensure to DISCHARGE capacitors before connecting them to the tester! Failure to do so may damage the tester.
- The built-in Li-ion battery is not waterproof. Do not immerse the tester in water or place it near a heat source.
- For your personal safety, strictly comply with the use of Li-ion Battery specifications and precautions.
- Battery measurement must be performed at the white terminal. Do not place the battery in the transistor area for measurement.
- Do not put components in the Transistor test area when testing Zener diodes, otherwise, the Zener diode cannot be tested.
3. Package Contents
Verify that all items are present in your package:
- 1 x LCR-MF10 Multi-function Tester
- 1 x Type-C USB Charging Cable
- 1 x Test Clip Cable Set
- 1 x SMD Test Adapter Board
- Assorted Test Components (e.g., LED, Resistor, Diode)

4. Product Overview
Familiarize yourself with the different parts of your LCR-MF10 Multi-function Tester:

- 128*160 TFT Display: High-resolution color screen for displaying measurement results.
- Zener Diode Test Area: Dedicated area for testing Zener diodes.
- Transistor Test Area: Socket for inserting and testing transistors and other components.
- LDC Voltage Test: Area for measuring DC voltage.
- Type-C Charging Port: For charging the internal battery.
- Charging Indicator Light: Indicates charging status (red for charging, green for charged).
- Power Switch: Turns the device on/off.
- OFF Button: Powers off the device at any time.
- TEST Button: Initiates a measurement.
- IR (Infrared) Sensor: For infrared remote control detection.
5. Specifications
| Component Type | Range / Parameter Description |
|---|---|
| BJT | hFE (DC Current Gain), Ube (Base-Emitter Voltage), Ic (Collector Current), Iceo (Collector Cut-off Current (IB=0)), Ices (Collector short Current), Uf (Forward Voltage of protecting diode) |
| Diode | Forward voltage <4.50V; Forward voltage drop, junction capacitance, reverse leakage current Ir |
| Double Diode | Forward voltage |
| Zener Diode | 0.01-4.50V (Transistor Test Area); 0.01-20V (Zener Diode Test Area); Forward voltage drop, reverse breakdown voltage, reverse breakdown voltage |
| JFET | Cg (Gate Capacitance), Id (Drain Current) at Vgs (Gate to Source Threshold Voltage), Uf Forw Voltage of protecting diode |
| MOSFET | Turn-on voltage Vt, gate capacitance Cg, drain resistance Rds, protection diode forward voltage drop Uf |
| IGBT | Collector current Ic under Vgs, protection diode forward voltage drop Uf |
| Thyristor / Triac | Gate trigger current <6mA; Gate turn-on voltage |
| Capacitor | 25pF-100mF; Capacitance Value, Equivalent Series Resistance ESR, D (Dissipation Factor) |
| Resistor | 0.01-50MΩ; Resistance |
| Inductor | 0.01mH-20H; Inductance, DC Resistance |
| Battery | 0.2-40V; DC Voltage Measurement area |
| Display Type | Digital Display (160x128 TFT color screen) |
| Operating Mode | Manual Range |
| Dimensions | 87*68*22mm |
| DIY Supplies | Electrical |
| Certification | CE |

6. Setup
6.1. Initial Power On
In the power-off state, short press the TEST key. The tester will turn on and automatically begin measurement. The device performs a self-check calibration upon startup.
6.2. Charging the Battery
The LCR-MF10 has a built-in rechargeable lithium battery. If the battery voltage is less than 3.1V, the device will automatically shut down, and you will need to charge it.
- Connect the Type-C charging cable to the Type-C charging port on the device.
- Connect the other end of the cable to an external 5V power supply or a USB power supply.
- The charging indicator light will be red while charging and turn green when fully charged.

7. Operating Instructions
To test a component, ensure the device is powered on. Place the component into the appropriate test area (transistor test area, Zener diode test area, or use test clips), then press the TEST button. The tester will automatically identify the component and display the measurement results on the TFT screen.
Video Demonstration:
This video demonstrates the testing process for various components including resistors, adjustable resistors, capacitors, inductors, diodes, Zener diodes, different types of transistors (BJT-NPN, BJT-PNP, NPN Darlington, P Darlington), MOSFETs (N-E-MOS, P-E-MOS, N-D-MOS), JFETs (N-JFET, P-JFET), Thyristors, Triacs, IGBTs (N-E-IGBT), voltage measurement, and SMT component inspection.
7.1. Component Testing
The tester automatically identifies the component type and pinout. Ensure components are correctly inserted into the ZIF socket or connected via test clips.
- Resistors: Insert the resistor leads into the transistor test area.
- Adjustable Resistors: Insert the leads into the transistor test area.
- Capacitors: IMPORTANT: Discharge capacitors before testing to prevent damage to the tester. Insert the capacitor leads into the transistor test area.
- Inductors: Insert the inductor leads into the transistor test area.
- Diodes (Single/Double): Insert the diode leads into the transistor test area.
- Zener Diodes: For Zener diodes with a voltage higher than 5V, they should be placed in the KAA area for measurement. For lower voltage Zener diodes, use the transistor test area.
- Transistors (BJT-NPN, BJT-PNP, Darlington): Insert the transistor leads into the transistor test area. The tester will identify the type and pinout (Base, Collector, Emitter).
- MOSFETs (N-E-MOS, P-E-MOS, N-D-MOS): Insert the MOSFET leads into the transistor test area. The tester will identify the type and pinout (Gate, Drain, Source).
- JFETs (N-JFET, P-JFET): Insert the JFET leads into the transistor test area.
- Thyristors / Triacs: Insert the leads into the transistor test area.
- IGBTs (N-E-IGBT): Insert the leads into the transistor test area.
- Voltage Measurement: Connect the battery or voltage source to the designated voltage measurement terminals (U+ and U-).
- SMT Component Inspection: Use the dedicated SMT test pads on the adapter board for surface mount components.
7.2. Infrared (IR) Remote Control Detection
The tester can decode Hitachi infrared encoding. Other formats are not supported.
- After a component test is completed, point an infrared remote control at the "IR" test hole of the tester.
- Press a button on the remote control.
- The tester will display the user code and data code upon successful decoding, and show the corresponding infrared waveform.
- If decoding fails, the user code and data code cannot be displayed. If you are in the tester interface, you cannot enter the infrared decoding interface. If you are in the infrared decoding interface, the last successful decoding information will still be displayed.

8. Automatic Calibration
To perform automatic calibration:
- Short-circuit the three test sockets (pins 1, 2, and 3) of the transistor test area.
- Short press the multi-function button (TEST button). The tester will automatically calibrate.
- During the calibration process, there is no need to perform other operations except to disconnect the short wire according to the prompts on the screen.
9. Maintenance
- Keep the device clean and dry. Avoid exposure to dust, dirt, and moisture.
- Store the device in a cool, dry place when not in use.
- Do not attempt to disassemble or modify the device, as this will void the warranty and may cause damage.
- The device has an auto power-off feature (default 59 seconds) to save power. It also has a standby power consumption of 0 uA after shutdown.
10. Troubleshooting
| Problem | Cause | Solution |
|---|---|---|
| Cannot power on | Lithium battery is low | Charge until the light turns green |
| Inaccurate measurements | Possible calibration issue or component damage | Re-calibrate the device (see Section 8) or check component integrity. |
10.1. Known Errors and Unsolved Problems
- The current amplification factor of germanium transistors can be measured too high due to high residual current, resulting in a very low base-emitter voltage.
- Capacitance value in reverse direction for Power Schottky Diodes (e.g., MBR3045PT) cannot be measured if only one diode is connected, due to excessively high leakage current. Cooling the device may sometimes enable measurement.
- The diode function of a triac gate cannot be examined.
- Source and Drain pins cannot be detected correctly with JFETs due to their symmetrical structure. The display may show the same layout and parameters if Source and Drain pins are swapped.
- The output current of this tester is 6 mA. High-power thyristors with a starting current greater than 6 mA will display a resistance value instead of thyristor parameters.
- The working voltage is less than 5 V.
- The turn-on voltage of high-power IGBTs exceeds 5 V, so the test result will be displayed as a diode.
- High-power IGBTs, thyristors, and Darlington transistors requiring high-current and high-voltage drive may not be measured correctly.
- Air-core coils and power inductors cannot be directly tested for inductance; series connection is recommended for measurement. It is suitable for testing color-ring inductors.
- For capacitors smaller than 20 pF, it is recommended to connect an external 20 pF capacitor for auxiliary testing.
11. User Tips
- Always double-check component polarity before insertion, especially for diodes and electrolytic capacitors.
- For small SMD components, use the provided adapter board for easier and more stable testing.
- If you encounter inconsistent readings, try re-calibrating the device.
- Keep the firmware updated if new versions become available, as this may improve accuracy and add features.
12. Warranty and Support
This product is covered by a standard manufacturer's warranty against defects in materials and workmanship. For detailed warranty information and technical support, please refer to the official product documentation or contact the seller directly.
A comprehensive user manual in PDF format is available for download: LCR-MF10 User Manual (PDF).
13. Environmental Disposal
This product contains electronic components and a lithium-ion battery. Do not dispose of it with general household waste. Please follow local regulations for the proper disposal of electronic waste and batteries to prevent potential harm to the environment and human health.