LILYTECH ZL-7802D

Contents

ZL-7802D Temperature and Humidity Controller

Model: ZL-7802D | Brand: LILYTECH

1. Introduction

The LILYTECH ZL-7802D is a versatile temperature and humidity controller designed for various applications, including incubators, climate rooms, and warehouses. It offers both PID and on/off temperature control, with an internal control resolution of 0.01°C for precise management. The unit features an integrated SSR with a 5A power driving ability, and supports optional external SSR-DA for heavier loads. With its auxiliary outputs, the controller can manage multiple environmental factors effectively.

2. Package Contents

Please check the package for the following items:

  • 1 x ZL-7802D Temperature and Humidity Controller
  • 1 x Combined Temperature and Humidity Sensor
  • 1 x USB Communication Cable
  • 1 x Fuse
  • 1 x Fuse Holder/Connectors
ZL-7802D controller with sensor, USB cable, and fuse
Figure 2.1: ZL-7802D Controller and included accessories.
ZL-7802D controller, sensor, USB cable, fuse, and product box
Figure 2.2: Complete package contents including the product box.

3. Specifications

Feature Specification
Model Number ZL-7802D
Display Type LCD Display
Temperature Sensor NTC, R25°C = 10K, B25/50°C = 3470K
Setting Range -40.0 ~ 99.9°C (Temperature), 10.0 ~ 90.0%RH (Humidity)
Temperature Resolution 0.1°C (0.18°F)
Power Supply 100-240Vac, 50/60Hz
Temperature Output (R5) Integrated SSR, 5A, 250Vac (resistance load)
External SSR Output (Y+, Y-) 4-20mA, 12Vdc
Humidity Output (R2) 10A, 250Vac (resistance load)
Output R1 7A, 250Vac (resistance load)
Output R3/R4 3A, 250Vac (resistance load)
Working Environment -10 ~ 45°C, 5 ~ 85%RH (without dew)
Protection Level IP65 (Front panel only)
Case Dimension L78 x W34.5 x D71 (mm)
Drilling Size L 71 x W29 (mm)
Communication Interface Serial Port
Weight 0.25 kg

4. Installation

Follow these steps to install the ZL-7802D controller:

  1. Insert the controller into the prepared mounting hole.
  2. Slide the provided bracket to fix the device securely in place.
Diagram showing the two-step installation process for the controller
Figure 4.1: Installation steps for the ZL-7802D controller.

5. Wiring Diagram

WARNING: Electrical wiring must be performed by a certified electrician. Ensure power is disconnected before wiring to prevent damage or injury. Incorrect wiring will damage the device.

Connect the controller according to the following diagram. Do not route the sensor bundle together with power supply bundles to avoid interference.

Detailed wiring diagram for the ZL-7802D controller, showing connections for power, sensors, and outputs (R1, R2, R3, R4, R5, EX-SSR)
Figure 5.1: ZL-7802D Wiring Diagram.

Key Connections:

  • Power Supply (7, 8, 9, 10): Connect 100~240Vac to terminals L (Live) and N (Neutral). Terminal 10 is for the R5 Heater output fuse.
  • Outputs (1-6):
    • R1 (Fan): Terminals 1 (COM) and 2 (7A 250V).
    • R2 (Humidity): Terminals 3 (COM) and 4 (10A 250V).
    • R3 (Left-turning): Terminal 5 (3A 250V).
    • R4 (Right-turning): Terminal 6 (3A 250V).
  • Humidity Sensor: Connect to the dedicated 3-pin connector.
  • Temperature Sensor (t1, DI): Terminals 13, 14, 15.
  • EX-SSR (External SSR): Terminals 11 (Y+) and 12 (Y-).

6. Display Icons

The ZL-7802D uses various icons on its LCD display to indicate status and functions:

Icon Function On Blink Off
Heating Heating SSRs on (PID controlling if U73=0) SSRs off
Humidifying Humidifying R2 on Delay protection, R2 on R2 off
Day Incubation days Has incubated for set days
A Alarming Alarming Alarming
AT PID Auto Tune Will start AT Auto tuning
✔ Set parameter Parameter setting
R1 on/off R1 on/off R1 timer on R1 over limit on R1 off
Left turning R3 Left turning R3 R3 on Start left turning, R3 on, icon blinks for 30 sec. R3 off
Right turning R4 Right turning R4 R4 on Start right turning, R4 on, icon blinks for 30 sec. R4 off

Note: Both 'Heating' and 'Humidifying' icons blink when egg turning times have reached the set times.

7. Operation

7.1. Setting Setpoints (Temperature & Humidity)

  1. Press and hold the S button for 3 seconds. The display will show the current temperature setpoint ('t' + setpoint) or humidity setpoint ('H' + setpoint).
  2. Press S to switch between temperature and humidity setpoint status.
  3. Use the ▲ or ▼ buttons to adjust the setpoint value. Holding the button will fast-set the value.
  4. Press and hold the S button for 3 seconds again to save the settings and exit.

If there is no key operation for 30 seconds, the settings will not be saved, and the unit will exit the setting status.

7.2. Parameter Code Table (Excerpt)

The controller has various configurable parameters. Here are some key ones:

Code Function Range Factory Set
U10Temperature setpoint up limitU11 ~ 99.9°C99.9
U11Temperature setpoint low limit-40.0°C ~ U10-40.0
U16Temperature hysteresis0.0 ~ 20.0°C0.2
U30Temperature calibration-20.0 ~ 20.0°C0.0
U46Output R1 working mode0-32
U50Humidity hysteresis0.1 ~ 20%RH2.0
U52Humidity calibration-20.0 ~ 20.0%RH0.0
U60Egg turn times set0 ~ 9990
U69Max incubation days set0 ~ 999 day30
U73Temperature control mode0-10
PProportion parameter: Kp0.1 ~ 99992.6
IIntegration parameter: Ti0 ~ 9999500
dDifferential parameter: Td0 ~ 999950

For a complete list of parameters and their detailed descriptions, please refer to the full PDF manual.

7.3. Temperature Control (R5 & EX-SSR)

The ZL-7802D supports two temperature control modes, configured by parameter U73:

  • PID Control (U73 = 0): Provides precise temperature regulation.
  • ON/OFF Control (U73 = 1): Uses hysteresis for simpler control.
    • If Room temp. ≥ Temp. setpoint, R5 and external SSR de-energize.
    • If Room temp. ≤ Temp. setpoint - [Temperature hysteresis U16], R5 and external SSR fully energize.

7.4. Humidity Control (R2)

  • If Room humidity ≥ Humidity setpoint, R2 de-energizes.
  • If Room humidity ≤ Humidity setpoint - [Humidity hysteresis U50], and R2 has stopped for [R2 delay protection time U51], R2 energizes.

7.5. Egg Turning Control (R3/R4)

Outputs R3 and R4 are universal timer outputs, primarily designed for incubator egg turning.

  • Timer Function:
    • During [Left turn R3 time U62], R3 energizes, R4 de-energizes.
    • During [Right turn R4 time U64], R4 energizes, R3 de-energizes.
  • One full egg turn = one left turn + one right turn. The egg turn counter tracks the number of full egg turns.
  • Manual Egg Turning:
    • Hold ▲ for 3 seconds to start right egg turning (R4 energized, R3 de-energized).
    • Hold ▼ for 3 seconds to start left egg turning (R3 energized, R4 de-energized).
  • Reset Egg Turn Counter: Hold S and ▼ simultaneously for 5 seconds. Display shows "cnt" + "Clr", then resets.

7.6. Incubation Days

  • Check Incubation Days: Press S and ▲ simultaneously to display "day" + "value" for 2 seconds.
  • Reset Incubation Days Counter: Hold S and ▲ simultaneously for 5 seconds. Display shows "day" + "Clr", then resets.

7.7. PID Auto Tuning (AT)

Auto-tuning helps optimize PID parameters for the best temperature control. Refer to the full PDF manual for detailed steps.

8. Error Codes and Alarms

The controller displays specific codes to indicate issues:

Display Remark
E1NTC sensor failure
E2Humidity sensor failure
tHiHigh temperature warning
tLoLow temperature warning
HHiHigh humidity warning
HLoLow humidity warning
AExternal digital input alarming
At1-At4PID auto tuning fails (various reasons)
SUc*PID auto tuning success
UnLRestore to factory settings

When an alarm occurs, the buzzer will sound (if U71=1), and relevant outputs may de-energize. Press P to stop beeping.

9. Maintenance

  • Sensor Calibration: The temperature and humidity sensors can be calibrated using parameters U30 and U52 respectively.
  • Cleaning: Keep the controller and sensors clean and free from dust or debris.
  • Environment: Avoid operating the device in corrosive, wet, or strong electrical-magnetic field environments.
  • Restore to Factory Settings: Hold P and ▲ simultaneously for 3 seconds until "UnL" displays. Then press S 3 times to restore all parameters to factory defaults, including the password.

10. Troubleshooting

If you encounter issues, refer to the error codes section (Section 8) and the following common troubleshooting tips:

  • Display shows E1 or E2: Indicates a sensor failure. Check the sensor connection or replace the sensor.
  • Temperature/Humidity readings are inaccurate: Consider calibrating the sensors (U30 for temperature, U52 for humidity).
  • Outputs not switching: Check wiring according to the diagram. Verify setpoints and hysteresis settings. Ensure the working mode (U46) is correctly configured.
  • Controller not responding: Ensure the power supply is stable (100-240Vac). Check for any overload conditions.
  • PID Auto Tuning fails (At1-At4): This can be due to temperature interference, abnormal oscillation, or timeout. Ensure the heater power rate (U74) is appropriate and there are no external disturbances during tuning.

11. User Tips

No specific user tips from reviews or Q&A were provided for this product. However, general advice for similar controllers includes:

  • Always double-check wiring before applying power.
  • For critical applications, consider using an external SSR-DA for heating elements with higher current draw or inductive loads.
  • Regularly clean the sensor to maintain accuracy, especially in dusty or humid environments.

12. Safety Warnings

  • Electrical Safety: All wiring must be performed by a qualified electrician. Disconnect power before any installation or maintenance.
  • Overload Protection: If the temperature heater power rate is high, or if there are inductive loads (e.g., coil wired heaters), use an external SSR-DA instead of the integrated SSR. For other large loads or capacitive/inductive loads (e.g., many humidifiers), consider using an intermediate relay, SSR-AA, or magnetic contactor.
  • Environmental Conditions: Avoid working in corrosive, wet, and strong electrical-magnetic field environments.
  • Warranty: Overload damage or damage due to wrong usage/connection is not covered under warranty.

13. Warranty and Support

This device has been thoroughly checked before shipment. A warranty period of one year is provided from the date of purchase. The warranty does not cover damage caused by incorrect usage, improper wiring, or other user-induced faults.

For detailed warranty terms, technical support, or further inquiries, please refer to the official product manual PDF:

Official PDF Manual: https://www.suzhoulily.com/pdf/ZL-7802D_V1.0b_en.pdf

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.