OUKITEL EP2500

Contents

OUKITEL EP2500 Balcony Solar Storage System User Manual

All-in-One Balcony Solar Storage System Plug & Play 2048Wh LiFePO4 Battery Expandable to 16.38kWh 4000W PV Input 800W-2500W On/Off Grid Power Station Waterproof rating IP65

1. Safety Precautions

When using this product, basic safety precautions should be followed, including:

  • Read all instructions before using this product.
  • If this product is used near children, continuous supervision is required to reduce risks.
  • Using accessories not recommended or sold by the professional manufacturer may cause a risk of electric shock.
  • Turn off the product when not in use.
  • Do not disassemble the product, as this may lead to unforeseen risks such as fire, explosion, or electric shock.
  • If the cable, plug, or output cord is damaged, do not use the product to avoid electric shock.
  • Please charge the product in a well-ventilated environment.
  • The product should be placed in a ventilated and dry environment to avoid electric shock caused by rain or moisture.
  • Do not expose the product to fire sources or high-temperature environments (such as direct sunlight or inside a hot vehicle), as this may result in fire or explosion.

Warning Symbols

Symbol Meaning
DANGER High voltage inside. Do not open. Risk of electric shock.
WARNING Never touch the enclosure of an operating battery. Disposal according to local regulations!
CAUTION Keep the product stable during handling and use. Avoid tilting to prevent danger.
CAUTION Read instructions carefully before performing any operation on the battery.
Do Not Touch Heat Sink During Operation.
Li-ion This symbol indicates that the product contains a lithium-ion (Li-ion) battery and should be properly handled or recycled in accordance with relevant regulations.
This symbol indicates that this product shall not be disposed of as household waste and should be taken to a designated recycling point for recycling or disposal. Proper recycling and disposal help protect the environment. For more information on the disposal and recycling of this product, please contact your local government, waste disposal authority, or the product retailer.
Batteries and accumulators must not be disposed of with household waste. According to legal requirements, consumers are required to take all batteries and accumulators to designated collection points for disposal, regardless of whether they contain hazardous substances.

2. Packaging List

The package includes the following items:

Item Description
EP2500E Core device of the system.
AC Power Cord Used to connect EP2500E to the grid.
Solar Cable Removal Tool Tool for disconnecting MC4 connectors.
Screws *5 For securing components.
Expansion Screws *3 For securing components.
Locking Fixings *3 For securing stacked units.
User Manual This document.
Warranty Card Provides warranty information.

Diagram of OUKITEL EP2500E packaging contents Figure 2.1: Diagram of EP2500E packaging contents.

Photo of OUKITEL EP2500E and its accessories Figure 2.2: Photo of EP2500E and its accessories.

3. Device Overview

The EP2500E integrates a bidirectional inverter and a high-reliability battery system into one unit. This device is suitable for outdoor environments and various residential scenarios such as garages, balconies, courtyards, and patios, providing users with a green energy lifestyle in different home settings.

  • Bidirectional AC grid connection: This function allows the product to both supply power to the home and draw electricity from the household grid. In self-consumption mode, the device automatically manages energy flow according to the home energy plan and continuously powers household appliances. At low battery level, the product can be quickly charged in custom mode to ensure sufficient power in emergency situations.
  • PV input: This product supports a maximum solar input power of 4000 W via four independent MPPT trackers, each supporting up to 1000 W PV input. The device can be connected to common rigid or flexible solar panels via standard MC4 connectors, as well as to EP2500E portable solar panels using an adapter cable.
  • Microinverter: The device is equipped with an AC socket. Grid-connected mode: up to 2500 W. Off-grid mode: up to 2500 W. If your home already has a balcony PV system with microinverters, simply plug it into the AC socket to integrate it into the EP2500E balcony energy storage system. The power output from the AC socket will first supply the home, and any excess electricity will be stored in the battery.
  • Stackable expansion: The system supports stacking up to seven expansion batteries. Each battery tower provides energy storage capacities from 2048 kWh up to 16384 kWh.
  • Remote / local control: The device supports both remote and local control. When the device is connected to a Wi-Fi, you can monitor its operating status in real time even when not on the same local area network.
  • Operating modes: This product supports two operating modes, which can be set on the EP2500E: grid-priority mode and backup power mode.
  • Standby state: In EP2500E standby state, the screen turns off after 30 minutes, the light strip enters a breathing-light standby state, while all other functions remain normal.

Overview of OUKITEL EP2500 features and benefits Figure 3.1: Key features of the OUKITEL EP2500.

OUKITEL EP2500 expandable battery capacity from 2.048kWh to 16.38 kWh Figure 3.2: Expandable battery capacity.

OUKITEL EP2500 use cases: Balcony Solar Storage, RV & Travel Energy, Home Backup Power, Garden & BBQ Power Figure 3.3: Versatile applications of the EP2500.

OUKITEL EP2500 safety features: LiFePo4 Battery Cells, 8-Level Vibration Tested, UL94 V-0 Fire Rating, ≤10ms Response Time Figure 3.4: Reliable protection features.

OUKITEL EP2500 power output modes: 800W On-grid Output, 3000W Bypass Power, 2500W Off-grid Backup Figure 3.5: Power output capabilities for various home needs.

OUKITEL EP2500 with mobile app monitoring energy usage Figure 3.6: Remote monitoring via mobile app.

OUKITEL EP2500 with IP65 protection in various weather conditions Figure 3.7: Built for all seasons with IP65 protection.

Graph showing solar generation and home consumption over a 24-hour period Figure 3.8: Optimizing solar power storage for peak demand.

4. Pre-Installation

General Procedures

To install and configure the complete system for home use, follow these steps:

  1. Prepare the installation location.
  2. Install the solar panels (refer to the User Manual of the purchased solar panels).
  3. (Optional) Stack expansion batteries (refer to the Installation section).
  4. Connect to Grid (refer to the Connecting to the Grid section).
  5. Connect the solar panels (refer to the Connecting Solar Panels section).
  6. Connect AC Loads or connect to an existing microinverter (refer to the Connecting AC Loads or Connecting to A Microinverter section).
  7. Turn on the EP2500E (refer to the Operation section).
  8. Configure the EP2500E (refer to the App User Manual).

Installation Site Preparation

Install the device on a dry, well-ventilated, stable, and level surface. The floor slope must not exceed 5°.

For long-term home use, ensure the device is kept away from fire sources, out of direct sunlight, and protected from rain or snow accumulation.

  • Place the device out of reach of children.
  • To ensure optimal operation and extend service life, the ambient temperature must not exceed 55°C and relative humidity must not exceed 95%.
  • Do not use this device at altitudes above 2000 m.
  • Do not place the device near flammable materials.
  • Do not place objects on top of the device or cover it.
  • Do not install the inverter near a TV antenna, other antennas, or antenna cables.

Installation Spacing

Sufficient space should be reserved to ensure good heat dissipation of the device.

Diagram showing recommended installation spacing for OUKITEL EP2500E Figure 4.1: Recommended installation spacing for proper heat dissipation.

Network Connection

To fully utilize the smart functions of the device, select a location with an internet connection so that the device can be connected to the EP2500E APP.

  • If the home WLAN signal is weak or unavailable, it is recommended to install a Wi-Fi repeater or signal extender to boost the signal.
  • Ensure the antenna is not obstructed so that the device can receive a stable signal.

5. Installation

Battery System

Up to 7 EP2000 expansion batteries can be stacked below the EP2500E to meet user demands for higher energy storage capacity. If you have purchased the EP2000 battery separately, please read this section carefully to ensure correct installation and proper operation with the EP2500E.

Expansion Battery Count Capacity Rated Charging Power Rated Discharge Power
02048Wh2500W2500W
14096Wh2500W2500W
26144Wh2500W2500W
38192Wh2500W2500W
410240Wh2500W2500W
512288Wh2500W2500W
614336Wh2500W2500W
716384Wh2500W2500W

Diagram showing OUKITEL EP2500E with various numbers of stacked EP2000 expansion batteries Figure 5.1: EP2500E with stacked expansion batteries.

Tools You May Need

During installation and wiring, you may need the following tools:

  • Level gauge
  • Marker pen
  • Tape measure
  • Phillips screwdriver
  • Electric drill & bits
  • Hammer

Stack Installation

NOTE: During installation, ensure the device is turned off.

  1. Remove the dust cap and bottom protective cover: Keep these protective covers and dust caps properly for future use when the device is stored separately.
  2. Stack the expansion batteries and EP2500E: Align the battery expansion connection ports and stack the expansion batteries with the EP2500E in sequence. Ensure that the bottom protective cover of the lowest expansion battery is installed in place.

Diagram showing removal of dust caps and stacking of OUKITEL EP2500E and expansion batteries Figure 5.2: Steps for stacking the EP2500E and expansion batteries.

  1. Install the anti-tip bracket on the wall: Install the wall mounting brackets on both sides of the expansion batteries and secure them to the wall to prevent the device from tipping over.
  2. Secure EP2500E and expansion batteries: Use the interlocking fasteners to connect and secure EP2500E with the adjacent expansion batteries.

Diagram showing installation of anti-tip brackets and securing stacked OUKITEL EP2500E units Figure 5.3: Anti-tip bracket and securing stacked units.

Installation complete.

6. Wiring

NOTE: During wiring, ensure the device is turned off.

Connecting to the Grid

This device supports a long-term connection to the building's grid access point. Use the AC power cord included in the package to connect the grid-connected interface to a wall outlet.

If higher output power is required, contact a certified electrician to inspect your electrical system to ensure compliance with local and national safety standards. After confirmation by the electrician, you can apply to increase the device's output power to 2500 W via the EP2500E App.

NOTE: When using EP2500E, ensure the device is properly grounded. Also confirm that the grounding of your home electrical system complies with regulations.

Diagram showing OUKITEL EP2500E connected to solar panels, grid, and home appliances Figure 6.1: Plug & Play Simplicity and Upgrade Existing Solar System solutions.

Disconnecting AC Power Cord

To remove the AC power cord, follow the steps below:

  1. Power off the device.
  2. Rotate the connector body to the left, then pull out the plug.
  3. Reattach the waterproof protective cap to the plug.

Connecting Solar Panels

This product is equipped with 4 MPPT trackers, each supporting up to 1000 W PV input, with a total PV input power of up to 4000 W. Each MPPT supports up to 60 V / 28 A solar input. Solar panels can be connected in series, in parallel, or directly to the device.

NOTE: When the device receives power from the solar panels, it will automatically start up and begin operation.

If you purchased EP2500E rigid or flexible solar panels, you can connect them directly to EP2500E, or first connect the solar panels in parallel before connecting to the device. Refer to the wiring diagram for detailed connection methods.

Diagrams showing series and parallel connections of solar panels to OUKITEL EP2500E Figure 6.2: Solar panel connection methods (series and parallel).

NOTE: When connecting multiple solar panels to one PV input, ensure that each string uses solar panels of the same model and quantity to avoid device damage or charging abnormalities caused by string voltage mismatch. Do not mix the positive and negative terminals of PV1, PV2, PV3, and PV4.

To ensure compatibility with third-party solar panels, verify that whether connected directly or in parallel, the open-circuit voltage (Voc) and operating current (Isc) of the solar panels do not exceed 60 V and 28 A. For connection methods, refer to the Connection Guide for EP2500E Solar Panel.

Connecting AC Loads

Plug electrical devices directly into the AC socket.

NOTE: To avoid risk of electric shock, do not use this socket in rainy weather.

This socket supports up to 2500 W AC output in grid-connected operation (bypass mode) and up to 2500 W output in off-grid operation (with at least one expansion battery connected). You can use the AC socket to power devices. In the event of a sudden power outage, EP2500E can automatically switch to battery power mode within 10 ms. As this function is not a professional UPS (uninterruptible power supply) function, the system does not support 0 ms seamless switching.

  • Do not connect devices that require extremely high uninterrupted power supply, such as data servers or workstation computers.
  • Test the compatibility of connected devices multiple times before use.
  • To avoid triggering overload protection, connect only one device at a time.

Failure to comply with the above instructions may result in device damage or data loss, for which OUKITEL assumes no responsibility.

7. Operation

Power On

If the device is not connected to any power source, press and hold the POWER button for more than 3 seconds; the device will start when the indicator lights up. The device will also automatically start when it receives power from solar panels or the utility grid.

After startup, EP2500E operates in grid-priority mode by default (when first power-on).

Power Off

Press and hold the POWER button for more than 3 seconds until the display goes off and the indicator flashes three times; the device then powers off.

During operation, if there is no operation for 30 minutes, the display will enter screen-off (sleep) mode and the indicator will enter breathing light mode.

NOTE: If the device is not to be used for an extended period, turn it off and disconnect the AC cable and PV cable.

Button Control

Button Operation Function
Power Press and hold it for 3 seconds Turn system on/off
Power Single click (when the device is on) Turn LCD on/off
Power Press it 4 times consecutively to enter Wi-Fi configuration Wi-Fi icon flashes

LED Indicators

LED Status Product Status
Power Off Press Power button to turn off the screen and the LED
Power Normally on Device enters sleep mode after 30 min, screen off, LED breathes

LCD Display Overview

Diagram of OUKITEL EP2500E product details and interfaces Figure 7.1: Product Details / Specs showing WLAN Antenna, DC Input Interface, Status LED Bar, LCD, Power Button, RS485/CAN, Release Valve, AC I/O Socket (grid-connected), AC Output Interface, Ground Terminal, Battery Expansion Interface.

Indicator No. Description Meaning
1On GridGrid-connected status: Icon on indicates system connected to mains.
2ON GRIDGrid status: Icon on indicates charging/discharging between system and grid.
3OFF GRIDGrid status: Icon on indicates no charging/discharging between system and grid.
4PVSolar input status: Displaying external solar input to PV.
5Parallel operation statusNumber indicates how many battery packs are connected.
6HOMESystem discharge status: Icon on indicates system is powering home appliances.
7Battery statusIcon on during both battery charging and discharging.
8High temperature iconIcon on indicates high battery temperature.
9WIFI1Normally on: WLAN connected. Flashing: Waiting for WLAN connection.
10WIFI2Normally on: WLAN connected. Flashing: Waiting for WLAN connection.
11ALMError Messages: Device detects a system fault. See "Troubleshooting" section for details.
12Low temperature iconIcon on indicates low battery temperature.
13Output powerDisplays output power (unit: W).
14Battery percentageDisplays current remaining battery percentage.
15Input powerDisplays input power (unit: W).
16AC OutputIndicates that the device is supplying power externally from the off-grid port.

8. Periodic Maintenance

NOTE: Before performing maintenance, disconnect the device from external power sources and turn off the device.

Heat Dissipation Inspection

If the device frequently reduces grid-connected output power due to excessive temperature, improve the heat dissipation conditions of the device.

  • Check whether objects are blocking the front or rear of the device.
  • Clean the heat sink of the device.

Inspection of Cables and Connectors

Inspect connectors and cables for externally visible damage once a year. If finding obvious damage on connectors or cables, replace them promptly.

Periodic Full Charging

If the battery has not been fully charged for a long time, it is recommended to perform a complete charge once a month to extend battery service life.

9. Storage

Store the device in a dry, clean, and well-ventilated environment. Storage temperature and humidity requirements are as follows:

  • 1 month: -20°C to 45°C (0-65%) RH
  • 3 months: 0°C to 45°C (0-65%) RH
  • 12 months: 0°C to 45°C (0-65%) RH

If the device needs to be stored for 3 to 6 months, perform the following routine maintenance steps:

  1. Open the EP2500E App and enable Custom Mode. Fully charge the battery, then let it stand for 30 minutes.
  2. Set Grid-Priority mode, set the discharge power to 800W, and discharge the battery until the battery SOC reaches 60%.
  3. Turn off the device, disconnect all cables, and store the device under the recommended environmental conditions.

10. Troubleshooting

Error Messages

If the following error codes are displayed, take the corresponding corrective actions. If the problem persists, contact the manufacturer's customer service personnel.

Error Code Cause Solution Hardware Related
F001BMS communication lostCheck if communication cable is looseMain control error
F002Microinverter communication lostCheck if communication cable is loose
F003Wi-Fi communication lostCheck if antenna is disconnected
F004Meter communication lostCheck if antenna is disconnected
F101Low discharge temperatureFault clears when temperature returns to recovery pointBMS protection info
F102Low charging temperatureFault clears when temperature returns to recovery point
F103High discharge temperatureFault clears when temperature returns to recovery point
F104High charging temperatureFault clears when temperature returns to recovery point
F105Cell or module overvoltageCheck if fault clears after restart
F106Cell or module undervoltageCheck if fault clears after restart
F107Discharge overcurrentCheck if fault clears after restart
F108Charging overcurrentCheck if fault clears after restart
F109Battery high voltage faultCheck if fault clears after restart
F110Battery low voltage faultCheck if fault clears after restart
F111System abnormalityCheck if fault clears after restart
FE01Battery overvoltageCheck if fault clears after restartInverter fault
FE02Battery undervoltageCheck if fault clears after restart
FE03Inverter overtemperatureFault clears when temperature returns to recovery point
FE04Abnormal grid voltageFault clears when voltage returns to normal
FE05Abnormal grid frequencyFault clears when frequency returns to normal
FE06Abnormal output voltageCheck if fault clears after restart
FE07Output short circuitFault clears after restart
FE08Output overloadFault clears after restart
FE09Inverter faultCheck if fault clears after restart
FE10PV overvoltageFault clears when voltage returns to normal
F111PV faultCheck if fault clears after restart

11. User Tips

  • Smart Meter Integration: For advanced energy management, such as achieving zero export, consider integrating with a compatible smart meter. Check the official website for available models and installation instructions.
  • App Configuration: Ensure you follow the app setup guide carefully for proper device configuration and to access all smart functionalities. If you encounter issues, try restarting your router and checking your home network's internet access.
  • Off-Grid Capability: The EP2500E is suitable for isolated homes without a grid connection, as it supports off-grid operation.
  • Environmental Conditions: For optimal performance and extended service life, operate the device within the recommended ambient temperature (not exceeding 55°C) and relative humidity (not exceeding 95%).
  • WLAN Signal Strength: If your home Wi-Fi signal is weak, use a Wi-Fi repeater or signal extender. Always ensure the device's antenna is unobstructed for a stable connection.
  • Solar Panel Compatibility: When connecting third-party solar panels, verify that their open-circuit voltage (Voc) and operating current (Isc) do not exceed 60 V and 28 A, respectively, to prevent damage.
  • AC Load Management: Avoid connecting devices that require extremely high uninterrupted power supply (e.g., data servers). To prevent overload, connect only one device at a time to the AC socket.

12. Frequently Asked Questions (FAQ)

The following table lists common problems you may encounter while using this product. For the latest FAQ information, please visit our official website.

Problem Solution
EP2500E App network connection failed
  • Confirm that the router is a 2.4 GHz network, as the device only supports 2.4 GHz Wi-Fi.
  • Check whether the device has already been paired with another network. If so, cancel the pairing first, then reconnect.
EP2500E App shows the device offline
  • Check whether the home network is abnormal; if so, restart the router.
  • Check whether the home network has internet access.
  • If the home network is normal, but the App still does not display device information, please contact the dealer or the technical support personnel.
Parallel operation fault (failed connection between main unit and battery pack)
  • After parallel connection, the power icon on indicates successful communication; after a moment, it indicates successful parallel connection. The device can only be used normally after successful parallel connection.
  • In case of parallel connection failed, verify that the connections are secure and reinstall the main unit and battery pack. Hardware problems are generally unlikely.
Device disconnected from the grid and discharge failed
  • Check the stop-discharge SOC set in the App. When the SOC is below the setting, the device cannot discharge.
  • Check whether the device has a fault such as overload or overtemperature. If a fault exists, the device cannot discharge.
Ground fault indicated after device startup Check whether the grid-connected interface is properly grounded and verify that the ground connection is in good condition. If grounding is poor, the device may not function correctly.
Low device grid output power
  • Check whether the device is overheating. Overheating causes the system to automatically limit output power.
  • If none of the above conditions exist, contact the dealer or the technical support personnel.
PV voltage exceeding allowable input range
  • Check whether the actual output voltage of the solar panels exceeds the device's PV input range.
  • If the voltage is within the allowable range but the problem persists, contact the dealer or technical support personnel.
Expansion battery fault and SOC below 5%
  1. Power off the device.
  2. Wait 5 minutes, then restart the device. The system will automatically charge the expansion battery at the minimum power.
  3. If the problem persists after restarting, contact the dealer or technical support personnel.

13. Technical Specifications

General Information

Item Specification
ModelEP2500E
Weight27.2 kg
Dimensions490 × 276 × 287 mm
IP RatingIP65
Pollution DegreeIII
Protection LevelI
Overvoltage CategoryII (DC); III (AC)
Inverter TopologyIsolated
Communication ModeWi-Fi

Battery Information

Item Specification
IEC CodeEP2000
Battery Chemical SystemLiFePO4
Rated Energy2048 Wh
Total Capacity40 Ah
Rated Voltage51.2 V d.c.
Voltage Range40-58.4 V d.c.
Charge and Discharge Current58 A/70 A Max.
Service Life4000 Cycles, 90% DOD, ≥70% SOH

DC Input (PV1/2/3/4)

Item Specification
Maximum Input Power1000 W *4
Maximum Input Voltage60 V d.c.
Maximum Input Current28 A *4
Voltage Range12-60 V d.c.

AC Input/Output (grid-connected)

Item Specification
Maximum AC Input Power2500 W
Maximum AC Input Apparent Power2500 VA
Maximum AC Input Current16 A
Maximum AC Output Power2500 W
Maximum AC Output Apparent Power2500 VA
Maximum AC Output Current16 A
Grid VoltageL+N+PE, 230 Va.c., 50 Hz
Power Factor Range0.8 leading...0.8 lagging
Maximum AC Output Power (bypass)2500 W
Maximum AC Output Current (bypass)16 A

Environmental Requirements

Item Specification
Environmental Temperature-20°C - 40°C
Ambient Humidity5%-95% RH

14. Warranty & Support

For detailed warranty information and support, please visit the official OUKITEL website: https://oukitel.com/pages/oukitel-power

15. APP Control

The OUKITEL EP2500 can be controlled and monitored via a dedicated mobile application. Follow the instructions below to set up and use the app.

App Installation

Search for "Smart Life - Smart Home" in the Google Play Store or Apple App Store to download and install the App. After installation, you can register and log in.

Available on the App Store Get it on Google Play

Alternatively, scan the QR code below to download and install the App:

QR code for Smart Life - Smart Home app download Figure 15.1: QR Code for App Download.

App Setup Guide

Watch this video for a step-by-step guide on installing the OUKITEL EP2500 and setting up the mobile application.

Video 15.1: OUKITEL EP2500 Installation & App Setup Guide.

Key steps from the video:

  1. Preparation Before Installation: Remove top and bottom connector covers from the main unit and battery packs.
  2. Stacking: Align and connect the battery packs in sequence, then secure them with curved and flat fixing plates.
  3. App Pairing: Press the power button on the EP2500E more than 4 times quickly until the light flashes, indicating pairing mode.
  4. Connect to Wi-Fi: Open the Smart Life app, click the '+' icon to add a device, select 'Balcony Energy Storage', and connect to your Wi-Fi network by entering the password.
  5. Monitoring & Settings: Once connected, the indicator light will flash slowly. You can then view real-time energy data and customize settings within the app.
Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.