Mudiro 8KW Diesel Air Heater

Contents

Mudiro 8KW Diesel Air Heater User Manual

Model: M-S1/M-H1 | Brand: Mudiro

1. Introduction

This manual provides detailed instructions for the safe and efficient operation of your Mudiro Diesel Air Heater. Diesel heaters are on-board heating devices independent of the automobile engine, featuring their own fuel lines, circuits, combustion heating devices, and control systems. Originally used to preheat vehicle engines and cabs in cold environments, they now offer a wider range of applications, serving as space heating equipment in tents, indoors, RVs, trucks, campers, and garages, enhancing user comfort during living and travel.

Please read this manual carefully before use to understand the product's functions and operational requirements.

2. Safety Information

CRITICAL SAFETY WARNING

The exhaust pipe operates at extremely high temperatures (up to 400°C / 752°F). Keep away from children, pets, and flammable materials. This heater MUST be vented outdoors to prevent carbon monoxide poisoning. Always ensure the exhaust pipe is properly directed outside.

During installation, use, maintenance, and scrapping of this machine, ensure there are no flammable or explosive materials around the exhaust pipe. Take care to avoid igniting flammable materials that may cause fire.

General Safety Guidelines:

  • Ensure proper ventilation when operating the heater.
  • Do not block the air inlet or outlet.
  • Regularly inspect the fuel lines and electrical connections for damage.
  • Do not operate the heater if any part is damaged or malfunctioning.
  • Keep the heater clean and free from dust and debris.

3. Product Overview and Principles

3.1 Explanation of Principles

3.1.1 Heat Source

Upon starting, the ignition plug heats up for 1-3 minutes. The fan then activates, delivering air to the combustion chamber, while the diesel pump injects diesel. The atomized diesel mixes with air and ignites upon contact with the high-temperature ignition plug, generating significant heat. High-temperature exhaust gases are discharged from the exhaust gas outlet below.

3.1.2 Heating

The heat generated in the combustion chamber is rapidly transferred to the aluminum heat exchanger and dissipated into the warm air duct via aluminum fins. An external fan blows air around the heat exchanger, and the heated air is expelled from the warm air outlet.

3.1.3 Control

The controller is integrated into the device. Users can control the device via the connected switch panel, checking operational status, adjusting settings, and scheduling operations. Remote control is also possible using the provided remote or the dedicated Mudiro mobile application.

3.2 Internal Key Parts Terminology

Familiarize yourself with the internal components before attempting any repairs.

Diagram of internal components of the diesel air heater
Internal components diagram: Control box, Ignition plug, Safety plug, Air inlet, Air outlet, Combustion chamber, Heating zone, Air fan, Flame retardant impeller.

4. Parts List

The following items are included in your package:

Image showing all packaged components of the diesel air heater
Packaged components: Host unit, AC-DC power supply (optional), Wire harness, Exhaust Silencer, Exhaust pipe, Air Outlet Pipe, Intake pipe, User Manual, Vents, Switch extension cord, Air Filter, Fixture Accessories set.
  • 1 x Diesel Air Heater (Host)
  • 1 x Remote Control
  • 1 x AC Power Adapter (for EU/UK/USA Plug type, if chosen with adapter)
  • 1 x Silencer
  • 1 x Exhaust hose
  • 1 set Screw Accessory Kit
  • 1 x User Manual (PDF available for download)
  • Wire harness
  • Air Outlet Pipe
  • Intake pipe
  • Vents
  • Switch extension cord (1.5m)
  • Air Filter

5. Setup and Installation

5.1 Power Supply Requirements

Use a 12V or 24V DC power supply, or an AC to DC adapter. The discharge current is recommended to be greater than 15A. The device requires heating the glow plug during startup, which can draw up to 12A for 3-5 minutes.

5.2 Installation Diagram

Installation diagram showing the heater connected to power and exhaust pipe
Typical installation setup. The exhaust pipe can be placed downwards or horizontally.

5.3 Exhaust Pipe Placement

The exhaust pipe must be directed outdoors. Ensure a safe distance from pets, children, and flammable materials. Maintain a gap from the ground to prevent damage to surfaces.

Diagram showing outdoor unit with indoor control via extension cord
The 1.5m extension cord allows for outdoor unit placement and indoor control.

6. Operating Instructions

6.1 Blue LCD Bluetooth Switch Instructions

Image of the LCD Bluetooth switch with key functions labeled
The LCD Bluetooth switch provides comprehensive control and status display.

6.1.1 Key Functions

  • Power Button (⑂): Press and hold to turn on/off the heater.
  • OK Button:
    • Short press: Query working status.
    • Continuous short press: Open corresponding function.
    • Long press: Enter timing setting and parameter setting.
    • After setting, short press to confirm, long press to return to main interface.
  • Up Button (▲):
    • Short press: Increase working temperature or oil quantity.
    • Press and hold: Open remote control pairing function.
  • Down Button (▼):
    • Short press: Lower operating temperature or oil quantity.
    • Press and hold: Open manual oil pumping function.

6.1.2 Function Introduction

  1. Machine Working Status Query: Briefly press OK once to view ambient temperature, shell temperature, set temperature/gear, power supply voltage, altitude, and timed startup/shutdown status.
  2. Temperature Control Mode Switching: Press OK twice in a row.
    • Automatic Temperature Control Mode (AT): Displays AT and temperature in °C.
    • Manual Temperature Control Mode (MT): Displays MT and an L-digit representing the gear.
  3. Voice Type Switching: Press OK three times in a row to cycle through four language options for voice broadcast.
  4. Temperature Unit Switching: Press OK four times in a row to switch between Celsius (°C) and Fahrenheit (°F).
  5. Automatic Start-Stop Function: Press OK five times in a row.
    • Enable: Displays AC-1.
    • Disable: Displays AC-0.
    • Operation: Heater starts automatically if ambient temperature is 2°C or more below set temperature, and shuts down if ambient temperature is 1°C or more above set temperature.
  6. Extreme Thermal Mode Function: Press OK six times in a row.
    • Enable: Displays HO-1.
    • Disable: Displays HO-0.
    • Operation: Increases pump oil quantity and adjusts air-oil ratio for rapid heating.
  7. Voice Prompt Function: Press OK seven times in a row to toggle voice prompts on/off.
  8. Remote Pairing Function: Long press the Up button to enter pairing mode (HF-1 or HF-2 displayed). Select HF-2, then short press the remote control power key to start. The switch returns to the main interface upon successful pairing.
  9. Manual Oil Pumping Function: Long press the Down button to enter manual oil pumping (H OF displayed). Short press Up to start (H ON displayed). Short press Down to stop (H OF displayed). Short press OK to return to main interface. Note: Stop pumping once fuel reaches the inlet to avoid black smoke from excess fuel.
  10. Timing Settings: Long press OK to enter timing settings. The alarm clock icon appears. Follow on-screen prompts to set startup and shutdown times (up to 99 hours, 59 minutes).

6.2 Bluetooth App Guide

The Mudiro heater supports control via a mobile application. The app allows you to set temperature, adjust gears, schedule timing, switch altitude mode, and more, with a Bluetooth range of up to 30 meters.

App download and Bluetooth connection guide with QR codes
Scan the QR code for iOS or Android app download, or search for "AirHeater" (iOS) / "Warm Drive" (Android) in app stores.

6.2.1 Download the App

  • iOS System: Scan the QR Code with your iPhone browser or search for "AirHeater" on the App Store.
  • Android System: Scan the QR Code with your Android mobile browser or search for "Warm Drive" on Google Play.

6.2.2 Connect for the First Time

Find the corresponding device in the app, click "Confirm Connection". The connection icon will appear on the switch panel. Press OK on the switch to confirm the connection.

7. Maintenance

Regular maintenance ensures the longevity and efficient operation of your diesel air heater.

  • Cleaning: Keep the exterior of the heater clean. Ensure air inlets and outlets are free from dust and obstructions.
  • Fuel System: Periodically check fuel lines for leaks or damage. Use clean, high-quality diesel fuel.
  • Electrical Connections: Inspect all electrical connections for tightness and corrosion.
  • Exhaust System: Ensure the exhaust pipe is clear and free from blockages.
  • Storage: If storing the heater for an extended period, ensure the fuel tank is empty or filled with fresh fuel and a fuel stabilizer.

8. Troubleshooting

The intelligent self-diagnosis system displays specific error codes (E-01 to E-13) for quick troubleshooting.

Diagram illustrating 4 major safety features: Overvoltage, Overheating, Reverse Connection, Short Circuit Protection
The heater is equipped with 4 major safety features for comprehensive protection.
Fault Code Machine Failure Treatment Method
E-01 Power supply undervoltage Insufficient supply voltage. Increase power supply voltage.
E-02 Power supply overvoltage Supply voltage too high. Reduce power supply voltage.
E-03 Glow plug fault Check if the glow plug is open circuit or short circuit.
E-04 Oil pump fault Check the oil pump and harness for wire breakage or short circuit.
E-05 Machine is overheating Check the temperature sensor on the housing. Check if fan speed is abnormal.
E-06 Motor failure Check magnet polarity, hall sensor position, or loose motor terminal.
E-07 Disconnection fault Check panel connection plug, blue wire harness for loose or broken connections.
E-08 Flame went out Check for air or oil in the oil circuit. Blockage due to wax deposition resulting in poor oil supply.
E-09 Faulty sensor Check if the sensor plug is loose, moved, or broken wire, short circuit.
E-10 Ignition failed Check whether the oil circuit is blocked, or the oil inlet is not smooth, the oil pump is stuck, and the secondary ignition fails due to blockage of the volatile screen caused by the problem.
E-11 Altitude sensor failure Altitude sensor failure, please check.
E-12 Faulty inlet air temperature sensor Air inlet temperature sensor failure, please check.
E-13 Outlet air temperature sensor fault Air outlet temperature sensor failure, please check.

9. Specifications

Feature Specification
Brand Name Mudiro
Model M-S1/M-H1
Input Voltage 12V / 24V DC / 100~240V AC (with adapter)
Power 5-8KW
Shell Colour Black & Red
Fuel Consumption 0.12 L/h - 0.46 L/h
Fuel Tank Capacity 5L
Remote Control Distance ≤30m (Bluetooth APP)
Working Ambient Temperature -40℃ to 40℃
Switch Type LCD Switch
Fuel Type Diesel
Item Height 25cm
Item Width 26cm
Item Length 38cm
External Testing Certification CE
Origin Mainland China
Power (W) <10W
Item Type Heating & Fans

10. User Tips

  • For garage use, many users report excellent performance, quickly heating spaces up to 55 sq meters.
  • Consider purchasing an additional 3-meter exhaust pipe for extended reach and better ventilation.
  • If experiencing issues with Bluetooth connectivity, try pressing the OK button on the controller quickly when "BLE" appears during pairing.
  • The heater is reported to start reliably on the first try after filling with fuel.
  • The unit can produce significant heat, with outlet temperatures exceeding 70 degrees Celsius.

11. Frequently Asked Questions (FAQ)

Q: Is there a CO monoxide alarm safety feature?
A: No, there is no built-in CO monoxide alarm safety feature. Always ensure proper outdoor ventilation to prevent carbon monoxide poisoning.
Q: What is the diameter of the air outlet?
A: The air outlet diameter is 75mm.
Q: Is this 5kW or 8kW?
A: This model is 8kW.

12. Support and Contact

Thank you for your support and trust in our product. Diesel heaters are complex, and you may encounter unexpected situations due to their use in various outdoor or indoor environments. If you face difficulties that you cannot resolve, please contact us for assistance with adjustments or repairs.

If you require technical support or have questions about our products, you can send an email to mudiromarketing@gmail.com or contact our after-sales personnel via the sales platform where you purchased the product. We will provide detailed instructions or operational videos to assist you.

A PDF user manual is available for download from the product page for additional guidance.

13. FCC Statement

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Note:

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

MADE IN CHINA

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.