Gaqqee LCR-MF10

Contents

LCR-MF10 Multi-function Tester User Manual

High-Precision Component Analyzer with TFT LCD Display

1. Introduction

The LCR-MF10 Multi-function Tester is a high-precision component analyzer designed for testing various electronic components. It features a 128x160 TFT LCD graphic display for intuitive visualization of measurement data. This device is capable of testing resistors, capacitors, inductors, diodes, transistors (NPN/PNP, Darlington), MOSFETs (N-MOS/P-MOS, N-D-MOS), JFETs (N-JFET, P-JFET), thyristors, triacs, IGBTs, and performing voltage measurements and infrared remote control decoding.

LCR-MF10 Multi-function Tester, a component analyzer with LCR/MOS/IGBT testing capabilities, built-in battery, and TTT display.

Figure 1: LCR-MF10 Multi-function Tester in use.

2. Safety Information

Please read all safety instructions before using the device. Improper use may result in electric shock, fire, or damage to the device. Keep the device away from water and high temperatures. Ensure components are discharged before testing, especially capacitors.

Warning: Please discharge components, especially capacitors, before testing to prevent damage to the device or injury.

3. Product Features

  • High Definition TFT Color Screen Display: 160 × 128 graphic display screen for intuitive visualization of measurement data.
  • Upgrade Anti-Burn Protection + Automatic Calibration: Comes with anti-burn protection and performs self-check calibration upon startup, ensuring measurement safety and durability.
  • Portable Lithium Battery Type-C Charging: Built-in rechargeable lithium battery, powered by Type-C. Automatically shuts down after 59 seconds to save power.
  • Infrared Decoding Waveform Display: Supports Hitachi infrared encoding, capable of receiving remote control signals and displaying infrared waveforms.
  • Component Full Compatibility Testing: Can test surface mount components, transistors, MOSFETs, IGBTs, and various other components such as resistors, voltage regulators, and thyristors.
LCR-MF10 Multi-function Tester showing RLC, Diode, Transistor, MOSFET, IGBT, SCR, and Battery Test capabilities. Highlights: Multi-function, High Precision, Easy to Use, Safe & Reliable.

Figure 2: Key features and capabilities of the LCR-MF10.

4. Package Contents

Please check the package contents upon receipt:

  • LCR-MF10 Host: 1 unit
  • TYPE C Charging Cable: 1 unit
  • Test Hook: 3 units
  • Capacitor: 1 unit (for testing/calibration)
  • Diode: 1 unit (for testing/calibration)
  • SMT Measuring Board: 1 unit
  • Calibration Needle: 1 unit
  • Instruction Manual: 1 copy
  • User Guide: 1 copy
  • Operation Manual: 1 copy
LCR-MF10 Multi-function Tester and its accessories including Type-C charging cable, test hooks, SMT measuring board, and sample components.

Figure 3: Included accessories with the LCR-MF10.

5. Device Overview

Diagram of the LCR-MF10 Multi-function Tester with labeled parts: 128*160 TFT screen, Zener diode test area, transistor test area, LDC voltage test, Type-C charging port, charging indicator light, power switch, test button, and power off button.

Figure 4: LCR-MF10 Multi-function Tester labeled diagram.

  • 128*160 TFT Screen: High-resolution display for test results.
  • Zener Diode Test Area: Dedicated area for Zener diode measurements.
  • Transistor Test Area: Area for testing various transistors.
  • LDC Voltage Test: For voltage measurements.
  • Type-C Charging Port: For charging the internal battery.
  • Charging Indicator Light: Indicates charging status.
  • Power Switch: To turn the device on/off.
  • Test Button (Green): Initiates a test.
  • Power Off Button (Red): Turns off the device.
  • IR Receiver: For infrared remote control decoding.
  • ZIF Socket (KAA): Zero Insertion Force socket for easy component insertion.

6. Setup

6.1 Initial Charging

Before first use, fully charge the device using the provided Type-C charging cable and a compatible USB power adapter (not included). The charging indicator light will show the charging status.

Close-up of the LCR-MF10's Type-C charging port with an incorrect Micro-USB cable being shown, highlighting the importance of using the correct Type-C cable.

Figure 5: Ensure to use the correct Type-C charging cable for the device.

6.2 Power On/Off

To power on the device, press the green "TEST" button. To power off, press the red "OFF" button. The device will automatically shut down after 59 seconds of inactivity to conserve battery life.

7. Operating Instructions

Always ensure components are fully discharged before inserting them into the tester. Use the ZIF socket (KAA) or test hooks for connecting components.

Play video
Watch video online

Video 1: Demonstration of various component testing with the LCR-MF10.

7.1 Component Testing Steps

  1. Discharge Component: Before testing any component, especially capacitors, ensure it is fully discharged.
  2. Insert Component: Carefully insert the component leads into the appropriate slots of the ZIF socket (labeled 1, 2, 3) or connect using the test hooks. For SMT components, use the SMT measuring board.
  3. Press TEST: Press the green "TEST" button to initiate the measurement.
  4. Read Results: The measurement results and component type will be displayed on the TFT screen.

7.2 Specific Component Testing

  • Resistors: Insert the resistor leads into any two or three pins of the ZIF socket. The resistance value will be displayed.LCR-MF10 testing a resistor, showing the resistance value on the screen.

    Figure 6: Testing a resistor.

  • Adjustable Resistors: Insert the leads. The tester will display the resistance values between the pins.
  • Capacitors: Ensure the capacitor is discharged. Insert the leads. The capacitance, Vloss, and ESR (Equivalent Series Resistance) will be displayed.
  • Inductors: Insert the leads. The inductance (L) and resistance (R) will be displayed.
  • Diodes (including Double and Zener Diodes): Insert the diode leads. The forward voltage (Uf) and reverse current (Ir) will be displayed. For Zener diodes with a voltage higher than 5V, they should be placed in the KAA area for measurement.
  • Transistors (BJT-NPN, BJT-PNP, Darlington): Insert the transistor leads into the ZIF socket. The tester will identify the type (NPN/PNP), pinout (Collector, Base, Emitter), hFE, Ic, and Ube.
  • MOSFETs (N-E-MOS, P-E-MOS, N-D-MOS): Insert the MOSFET leads. The tester will identify the type, pinout (Drain, Gate, Source), threshold voltage (Vt), gate capacitance (Cg), and on-resistance (RDS).
  • JFETs (N-JFET, P-JFET): Insert the JFET leads. The tester will identify the type, pinout (Drain, Gate, Source), Idss, and Vg.
  • Thyristors and Triacs: Insert the leads. The tester will identify the component type and Uf.
  • IGBTs (N-E-IGBT): Insert the IGBT leads. The tester will identify the type, pinout (Collector, Gate, Emitter), threshold voltage (Vt), and gate capacitance (Cg).
  • Voltage Measurement: Connect the voltage source to the designated voltage test points. The voltage will be displayed.
  • Infrared Remote Control Detection: Point an infrared remote control towards the IR receiver on the tester and press a button. The tester will display the infrared encoding (UserCode and DataCode) if it supports the NEC format.LCR-MF10 displaying infrared decoding waveform from a remote control, showing UserCode and DataCode.

    Figure 7: Infrared decoding waveform display.

  • SMT Component Inspection: Use the SMT measuring board to test surface mount components.

8. Specifications

ParameterValue
Power Supply InterfaceType C
Capacitor Measurement Range25pF - 100mF
Resistor Measurement Range0.01Ω - 50MΩ
Inductor Measurement Range0.01mH - 20H
Battery Voltage Range0.2V - 40V
Zener Diode Test Area (Transistor)0.01V - 4.50V
Zener Diode Test Area (Dedicated)0.01V - 20V
Product Dimensions87mm * 68mm * 22mm
Display128*160 TFT LCD
Table of product parameters for the LCR-MF10 Multi-function Tester.

Figure 8: Detailed product specifications.

9. Maintenance

  • Cleaning: Use a soft, dry cloth to clean the device. Do not use abrasive cleaners or solvents.
  • Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures.
  • Battery Care: For long-term storage, charge the battery to about 50% every few months to prolong its lifespan.

10. Troubleshooting

  • Device not turning on: Ensure the battery is charged. Connect the Type-C charging cable and try again.
  • Incorrect readings:
    • Ensure the component is correctly inserted into the ZIF socket or connected via test hooks.
    • Verify the component is fully discharged before testing.
    • Perform a self-check calibration by restarting the device.
  • "Probes Open" message: This indicates no component is detected or there is a poor connection. Check the component insertion or test hook connections.

11. User Tips

  • Charging Cable Compatibility: Some users have reported receiving an incorrect charging cable (e.g., Micro-USB instead of Type-C). Always verify that the included cable matches the Type-C port on the device. If not, use a compatible Type-C cable for charging.
  • Capacitor Discharge: Always double-check that capacitors are fully discharged before inserting them into the tester to prevent damage.
  • SMT Testing: Utilize the provided SMT measuring board for convenient testing of surface mount components.

12. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the seller's contact information or the official product page. Keep your purchase receipt as proof of purchase.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.