Veinasa VWT002Y

Contents

User Manual

VWT002Y 2 in 1 Ultrasonic Wind Speed and Direction Sensor Anemometer

Model: VWT002Y | Brand: Veinasa

1. Introduction

The Veinasa VWT002Y is a compact, highly integrated 2-in-1 ultrasonic sensor designed for accurate measurement of wind speed and wind direction. Utilizing advanced ultrasonic technology, this device provides reliable data for various applications. Its robust IP65-rated, corrosion-resistant engineering plastic enclosure makes it suitable for harsh outdoor environments.

Veinasa VWT002Y Ultrasonic Wind Sensor
Figure 1: Veinasa VWT002Y Ultrasonic Wind Speed and Direction Sensor.
VWT002Y Compact Weather Station in an outdoor setting
Figure 2: The VWT002Y functions as a compact weather station, measuring wind speed and direction.

This manual provides essential information for the proper installation, operation, and maintenance of your VWT002Y sensor.

2. Safety Information

Please read and understand all safety instructions before installing or operating the device. Failure to follow these instructions may result in injury or damage to the product.

  • Ensure the power supply matches the specified voltage range (DC 9-24V) to prevent electrical damage.
  • Avoid direct contact with internal components when the device is powered on.
  • Mount the sensor securely to prevent it from falling, especially in windy conditions.
  • Do not attempt to modify or repair the device yourself. Refer to qualified personnel for service.
  • Keep the device away from strong electromagnetic interference sources.

3. Package Contents

Upon receiving your VWT002Y sensor, please verify that all components are present and undamaged:

  • VWT002Y Ultrasonic Wind Speed and Direction Sensor
  • Standard Cable (3 meters)
  • Mounting Accessories (Sleeve-type standard, other options may be purchased separately)
  • User Manual (PDF version available online)

4. Product Overview

The VWT002Y sensor uses ultrasonic pulses to measure wind speed and direction without moving parts, ensuring high reliability and minimal maintenance. It features an all-in-one highly integrated design to minimize equipment count and wiring complexity. A layered protection structure ensures optimal airflow for accurate readings.

VWT002Y sensor showing wind speed and direction ranges, RS485 output, and power supply
Figure 3: Key features of the VWT002Y sensor, including measurement ranges and output.
Diagram illustrating ultrasonic wind measurement technology and multiple output interfaces
Figure 4: Ultrasonic Wind Measurement Technology and Multiple Output/Expansion Interfaces.

The sensor offers standard RS485 + Modbus RTU output, with optional SDI-12, CAN, NMEA, and ASCII (Vaisala compatible) interfaces available.

Video 1: Product overview of the VWT002Y Ultrasonic Wind Sensor.

5. Specifications

The following table details the technical specifications of the VWT002Y sensor:

Table of Technical Specifications for VWT002Y sensor
Figure 5: Technical Specifications of the VWT002Y.
VWT002Y Technical Specifications
Parameter Range Accuracy Resolution Sampling Frequency
Air Temperature -40~85°C ±0.3°C (@25°C) 0.01°C 1 Hz
Air Humidity 0-100%RH ±3%RH (10%~80%RH, no condensation) 0.01%RH 1 Hz
Wind Speed 0-60 m/s ±(0.5 + 0.05V) m/s 0.01 m/s 4 Hz
Wind Direction 0-359.9° V is the calibrated wind tunnel speed value (m/s) 0.1° 4 Hz
Atmospheric Pressure 500-1100 hPa ±5° (@10 m/s) 0.1 hPa 1 Hz
Precipitation 0-200 mm/h ±0.5 hPa (@25°C, 950~1100 hPa) 0.01 mm 1 Hz
Illumination 0-100 Klux ±3% F.S 10 Lux 1 Hz
Total Radiation 0-1500 W/m² ±5% 1 W/m² 1 Hz
Complete Machine Parameters
Operating Temperature -20°C ~ 60°C
Output Interface RS485, Modbus RTU
Maximum Output Frequency Passive mode: 1 time/second; Active mode: 1 time/minute
Power Supply Voltage DC 9~24V (recommended DC 12V)
Protection Level IP65
Mounting Method Sleeve type (standard); flange type, bent plate type (optional)
Standard Cables 3 meters (optionally available with 10 meters)
Optional Protocols NMEA, ASCII (compatible with Vaisala), CAN (ASCII)

Dimensions

Product dimensions diagram showing height and width
Figure 6: Product Dimensions Diagram (Height: 108.30 mm, Width: 83.03 mm).
Product dimensions diagram with hands for scale
Figure 7: Product Dimensions Diagram with additional measurements (61.0mm, 49.0mm, 41.0mm) and hands for scale.

6. Setup

6.1 Mounting

The VWT002Y offers flexible installation methods. The standard mounting is sleeve-type, but flange type and bent plate type options are also available (may require separate purchase).

Images showing flexible installation methods for the sensor
Figure 8: Examples of flexible installation methods, including sleeve-type and flange mounting.
Images demonstrating sleeve-type and flange mounting options
Figure 9: Detailed views of sleeve-type (standard) and flange mounting options.

Ensure the sensor is mounted in an open area, free from obstructions that could interfere with wind flow, to obtain accurate readings.

6.2 Wiring

The VWT002Y sensor uses an RS485 interface for data output and requires a DC 9-24V power supply. It supports solar power supply, making it suitable for remote areas.

VWT002Y sensor showing RS485 signal output
Figure 10: The sensor provides RS485 signal output.
Diagram showing DC 9-24V power supply mode, compatible with solar power
Figure 11: Power supply mode DC 9-24V, supporting solar power for remote installations.

Connect the sensor to your data acquisition system or controller using the provided cable. Refer to the detailed wiring diagram in the official PDF user manual for specific pin assignments and connection instructions.

7. Operation

Once properly installed and powered, the VWT002Y sensor will begin measuring wind speed and direction. Data is output via the configured interface (RS485 Modbus RTU by default).

  • Data Acquisition: Use a compatible data logger, PLC, or computer system with an RS485 interface to read the sensor data.
  • Modbus Protocol: The sensor communicates using the Modbus RTU protocol. Refer to the official PDF user manual for the Modbus register map and communication parameters.
  • Sampling Frequency: The sensor provides wind speed and direction data at a sampling frequency of 4 Hz in active mode.

For detailed information on communication protocols and data interpretation, please consult the comprehensive user manual available in PDF format.

8. Maintenance

The VWT002Y sensor is designed for low maintenance due to its non-moving parts and robust construction.

  • Cleaning: Periodically inspect the sensor for any accumulation of dirt, dust, or debris on its surface. Gently clean with a soft, damp cloth. Do not use abrasive cleaners or solvents.
  • Environmental Protection: The sensor has an IP65 high protection rating, making it dustproof and waterproof. Its corrosion-resistant engineering plastic enclosure ensures extended service life in harsh outdoor environments.
VWT002Y sensor with IP65 High Protection Rating, dustproof and waterproof
Figure 12: The VWT002Y features an IP65 rating for dust and water resistance.
VWT002Y sensor showing IP65 rating and corrosion-resistant enclosure
Figure 13: IP65 High Protection Rating and corrosion-resistant engineering plastic enclosure for durability.

Regular visual inspections are recommended to ensure the sensor remains free from physical damage or obstructions.

9. Troubleshooting

If you encounter issues with your VWT002Y sensor, consider the following common troubleshooting steps:

  • No Data Output:
    • Check power supply connections and ensure the voltage is within DC 9-24V.
    • Verify wiring connections for RS485 (A/B lines, GND).
    • Confirm communication parameters (baud rate, parity, data bits, stop bits) match between the sensor and your data acquisition system.
    • Ensure the sensor is not obstructed or damaged.
  • Inaccurate Readings:
    • Check for any physical obstructions around the sensor that might be affecting wind flow.
    • Ensure the sensor is mounted level and securely.
    • Clean the sensor surface if there is any dirt or debris accumulation.
  • Intermittent Data:
    • Check cable integrity for any breaks or loose connections.
    • Ensure proper grounding to minimize electrical noise.
    • Verify the stability of the power supply.

For more complex issues or if troubleshooting steps do not resolve the problem, please refer to the official PDF user manual or contact customer support.

10. User Tips

No specific user tips were available from customer reviews or Q&A for this product at this time. General best practices for environmental sensors include:

  • Regularly check the mounting stability, especially after severe weather.
  • Keep the sensor's measurement area clear of new obstructions (e.g., growing vegetation, new structures).
  • Consider using a surge protector for the power supply in areas prone to lightning.

11. Warranty and Support

For detailed warranty information, technical support, or service inquiries, please refer to the official product documentation or contact Veinasa customer service. The official user manual in PDF format provides comprehensive details on all aspects of the product.

You can view the official user manual (PDF) here.

12. Applications

The VWT002Y sensor is versatile and can be used in a wide range of applications, including:

Images showing various applications for the wind sensor: Scenic Environment Monitoring, Smart Street Lights, Agricultural Meteorology, Highway, Smart City, New Energy Monitoring
Figure 14: Diverse applications of the VWT002Y sensor.
  • Scenic Environment Monitoring
  • Smart Street Lights
  • Agricultural Meteorology
  • Highway Weather Monitoring
  • Smart City Infrastructure
  • New Energy Monitoring (e.g., wind farms)

Ask a question about this manual