The MYOSLIM X3 Pro AI Skin Analyzer is a professional-grade intelligent device designed for comprehensive skin and scalp analysis. It provides personalized and accurate assessments, guiding users toward effective skincare and beauty customization solutions. This instrument features dual detection modes, balancing flexibility and comprehensiveness, making it suitable for various professional settings such as beauty institutions, skin management centers, makeup studios, and for scalp care and sun protection education.
The X3 Pro utilizes an advanced AI intelligent deep analysis algorithm to cover all dimensions of skin concerns, including acne, sensitivity, pigmentation, aging, moisture levels, sunscreen efficacy, and fluorescent agent detection. It can intelligently classify skin types and identify skin breakage. With its skin+scalp dual-mode detection, it integrates facial skin analysis and scalp hair follicle detection into one device.
Equipped with an 8-spectral professional light source, the device scans the epidermis, dermis, and subcutaneous tissue in layers, revealing hidden pigmentation, underlying inflammation, potential red blood streaks, and hair follicle blockages in high definition. Its 36 million pixel professional industrial-grade imaging lens and fully shaded professional dark box ensure realistic, accurate, and delicate imaging with impactful contrast.
The device features a simple and stylish appearance with a 15.6-inch ultra-clear touch screen for intuitive operation and parameter display. The full-face AI detection mode supports manual rotation of the camera to capture facial images from three angles, and the 8 spectral imaging methods identify surface defects, subcutaneous redness, and hidden pigmentation in layers, generating summarized skin analysis reports.
Video: Demonstration of the MYOSLIM X3 Pro AI Skin Analyzer in operation, showcasing its features and user interface.
2. Specifications
2.1 General Specifications
- Brand Name: MYOSLIM
- Model: X3 Pro
- Manufacturing Process: Hand Made
- Material: Metal
- Number of Pieces: One Unit
- Power Source: Electric (EU, AU, US, UK, Japanese, Korean compatible)
- Voltage: 110 V
- Commodity Quality Certification: CE
- Certification: RoHS, CE
- Origin: Mainland China
- Medical supervision required?: N
- High-concerned chemical: none
- Hand Instrument: Yes
2.2 Technical Parameters
| Parameter | Value |
|---|---|
| Pixel | 36 Million |
| Spectrum | 8 Spectra |
| Memory | 4GB |
| Brightness | 350NITS |
| HDMI | 1PCS |
| USB | 2PCS |
| Screen Ratio | 16:9 |
| Screen Size | 15.6-inch |
| Screen Pixels | 1920*1080 |
| Shipping Weight | 12.2KG |
| Dimensions | 51X51X56.5CM |
2.3 Package Dimensions
- Length: 20 cm
- Width: 30 cm
- Height: 20 cm
- Weight: 20.0 kg

Image: Product Configuration Display, showing components like forehead pad, light shielding film, chin rest, handheld micro-moisture detector, logo, power socket, HDMI jack, USB sockets, power switch, hair detector interface, and WIFI jack.
3. Setup
- Add Water: Ensure the water tank is filled with pure water or deionized water. Tap water or mineral water should not be used.
- Connect Power: Connect the power cord to the device. Verify the correct voltage (220V or 110V) for your region to avoid incorrect connections. The instrument must be connected to the specified power supply (AC200-240V).
- Power On: Rotate the power key. The machine will enter the power-on interface after approximately three seconds. Tap and press to proceed.
- Handheld Probe Connection: Ensure the handheld micro-moisture detector is securely connected to its interface.
4. Operating Instructions
4.1 Initial Interface and Mode Selection
Upon powering on, the device will display the main operating interface. The system offers various analysis modes:
- Full-Face AI Detection Mode: This mode captures facial images from three angles (manually rotated) using 8 different spectral imaging methods to identify surface defects, subcutaneous redness, and hidden pigmentation in layers. AI then summarizes and generates skin analysis results.
- Scalp Detection Mode: This mode analyzes scalp conditions, including oiliness, microbial flora, and sensitivity. Detection areas include the forehead, left side, right side, top of head, and nape. Shooting spectrums include White Light, Cross Polarized Light, and UV Light.
- Micro-Analysis Detection Mode: This mode examines skin conditions such as inflammation, redness (capillaries), and pigmentation from a microscopic perspective.

Image: Full Face AI Detection Mode interface, showing the process of capturing facial images from different angles and the resulting spectral images.

Image: Scalp Detection Mode interface, illustrating detection areas and shooting spectrums for scalp analysis.

Image: Micro-Analysis Detection Mode interface, showing microscopic detection images and science popularization interpretation.
4.2 Parameter Adjustment and Operation
- Select Skin Type/Area: In the working interface, select the appropriate skin type (I-VI) based on the client's skin color. For body hair analysis, select the corresponding body part (S, M, L, XL) as needed.
- Cooling Activation: Before starting any analysis that involves light emission, turn on the freezing switch to allow the handheld probe to cool. The snowflake icon will turn blue when active.
- Initiate Analysis: Press the key on the device. The handheld probe's TEC (Thermoelectric Cooler) will begin cooling, indicated by a red light.
- Perform Analysis: Hold the handheld probe perpendicular to the skin and in contact with it. Gently press the probe against the skin to ensure good contact. Perform the analysis by pressing the button on the handle.
- Pause/Standby: To pause the operation, press the button to stop working and enter standby mode.
4.3 Post-Analysis Care
- Immediately after the procedure, use cold (but not frozen) ice packs or cooled 10x10cm soaked gauze to cool the treated area to minimize edema and discomfort.
- For 4-5 days after the operation, prevent trauma by avoiding hot water baths, strenuous exercise, and massages.
- Advise patients to wear high-index sunscreen (SPF>30) and avoid direct sunlight on the treated area for at least one month after the procedure to prevent melanin regeneration and pigmentation.
- Makeup can be worn during the day unless blisters or hard nodules appear. Exercise caution when removing makeup due to skin sensitivity.
- If the treated area comes into contact with dirt, apply a topical dressing for 10 days.
5. Safety Information and Warnings
5.1 General Precautions
- Always read and understand the entire instruction manual before operating the system.
- Treatment should be conducted in an isolated, separate room.
- Keep the touch screen away from water. Do not use alcohol or other substances to clean the plastic case or display.
- Do not place additional objects on the instrument.
- Prior to any procedure, clean the treatment area and apply cold gel if necessary.
- Always check handheld probe cooling before use to avoid abnormal cooling circulation.
- Do not use your eyes to look directly at the light outlet of the handheld probe when the READY button is lit, and never point the light at eyes.
- During operation, the probe must be held close to the client's skin for compression sliding; do not operate with the skin empty.
- Do not allow the probe to hit black objects, including clothing.
5.2 Eye Protection
- All personnel in the treatment room, including the client and operator, must wear appropriate protective eyewear.
- Eyes should be optically dense (OD>5).
- Clients should close their eyes during treatment, even when wearing glasses.
- If the client cannot wear eyeglasses, use eye patches to completely block light.
- If the area to be treated is very close to the eye (e.g., the eyelid), a corneal plate should be used.
- Never look directly into the laser beam or reflective surface of the handheld probe.
- Set the system to standby mode during any pause in operations to prevent accidental light emission.
5.3 Fire Safety
- Remove any hair from the treatment area.
- Place only sterilized water-soaked gauze near the treatment area if needed.
- Ensure fire extinguishers are always available and accessible.
- Avoid flammable paper products and ensure they have evaporated before light exposure.
- Do not use the system in the presence of flammable materials or anesthetics.
- Oxygen tubing must be laser-safe.
5.4 Contraindications (General)
The following conditions may contraindicate the use of this device or require special consideration by a qualified professional:
- Cancer, especially skin cancer
- Pregnancy (including IVF)
- Use of photosensitizing drugs and herbs
- Active inflammation or herpes simplex infection in the treatment area
- History of scarring tumors
- Diabetes (insulin-dependent)
- Dry and Sensitive Skin
- Endocrine disruption (bright light can cause irritation)
- Use of anticoagulants
- Epilepsy
- History of blood coagulation
- Conditions susceptible to irritation from light exposure or artificial tanning within 3 to 4 weeks prior to treatment.
5.5 Potential Side Effects
Similar to other light-based technologies, improper use can lead to tissue damage. Potential side effects include:
- Discomfort: Some clients may experience a sensation similar to a rubber band snap or burning during light emission.
- Erythema and Edema: Redness and swelling may occur for 2-24 hours after the procedure, potentially lasting several weeks.
- Allergy/Itching/Burning/Pain: These symptoms may occur in the treated area for up to 48 hours.
- Blisters/Epidermal Necrolysis/Pigmentation: In some cases, blisters, epidermal necrolysis, or pigmentation changes may appear, lasting days to weeks.
- Pigmentation Changes: Hyperpigmentation or hypopigmentation may occur, especially in skin types IV-VI or if the skin was exposed to sunlight before, during, or within 3 weeks of treatment. These changes may fade over 3-6 months, but can be permanent in rare cases.
- Scarring: Rare, but hyperplastic hypertrophic scars or keloid tumors can occur.
- Fragile Skin: The skin in and around the treated area may become fragile. Avoid makeup and rubbing.
- Bruising: A purple bruise may appear, fading over 1-3 months.

Image: Multi-angle product display, showing the device from various perspectives including front, side, and rear views.
6. Maintenance
- Water Tank: Keep the water tank sufficiently filled with clean, pure, or deionized water. It is recommended to change the water once a month.
- Cleaning: Keep the touch screen away from water. Do not use alcohol or other harsh chemicals to clean the plastic case and display of the instrument.
- Environmental Conditions: Maintain room temperature between 5°C and 28°C. In summer, operate in an air-conditioned room to prevent high water temperature. In winter, prevent water from freezing.
- Handle Care: Use a handle collar to prevent the handheld probe from falling.
7. Troubleshooting
| Error# | Safeguard | Possible Causes and Troubleshooting |
|---|---|---|
| Temp1 error | Control board temperature alarm | 1. The temperature is too high. 2. The control board fan does not work. 3. The temperature sensor is bad or broken wire (note that the control board fan only turns when the light). |
| Temp2 error | Room temperature alarm | 1. Room temperature is too high; need to control the room temperature below 28°C. 2. The machine has poor heat dissipation, the internal temperature of the machine is too high. 3. Temperature sensor damage (soaked in water is easy to bad). (If the temperature sensor is in the water tank, that is the water temperature alarm). |
| Flow error | Water flow alarm | 1. The water flow is not enough, mainly due to small pump pressure, thin water pipe, connector water resistance, or unreasonable water circuit. 2. There is a leakage of air in the water circuit. 3. The flow sensor is damaged. 4. Check the wiring. |
| Level error | Tank water level alarm | 1. The water is not added enough. 2. The water level is stuck without floating up. 3. Check whether there is a false welding. 4. Control board problems. |
| The handle doesn't light up | Macro channel Non channel | 1. (a) Handle does not light: visual inspection of the laser appearance, there is a buckle broken phenomenon, send back to the original factory maintenance. (b) If there are no alarms on the machine interface and the READY changes color normally, either the hitch bar in the handle is loose or the power cord supplying power to the handle is loose. 2. Weak light out of the handle, laser or control board problems. |
| Blue screen | Monitor | 1. The handle button did not pop up. 2. The terminal wires on the control board are stuck together. 3. If there is a foot pedal, test whether the foot pedal wire connection is twisted together, or directly cut the wire. 4. The foot pedal dripped into the water, wait for the water to dry out. |
| Black screen | Monitor | 1. The screen is into the water. 2. Heavy objects crushed the screen. 3. Control board problems. 4. Control board and screen wires loose. |
| TEC does not cool | TEC | 1. TEC refrigerator is bad. 2. Test the relay in the chassis whether all bright, may be one of the relay is bad. |
8. User Tips
No specific user tips were available from provided reviews or Q&A content.
9. Warranty and Support
The main unit of the MYOSLIM X3 Pro AI Skin Analyzer comes with a one-year warranty, and accessories are covered for three months.
For support, the manufacturer provides:
- Online support
- Free spare parts
- Video technical support
For any inquiries or assistance, please contact customer service.