1. Product Overview
The JIKONG JK-BD6A24S20PD Smart Battery Management System (BMS) is a sophisticated protection board designed for large-capacity series lithium battery packs. It integrates essential functions such as voltage acquisition, high-current active balancing, overcharge/over-discharge/overcurrent/overtemperature protection, coulomb metering, Bluetooth communication, and optional GPS remote capabilities.
This BMS is compatible with various battery chemistries, including Lithium Iron Phosphate (LiFePO4), Ternary Lithium, and Lithium Titanate (LTO) types. It features an energy transfer active balancing technology with a continuous balancing current of 0.6A, ensuring battery consistency, extended range, and delayed aging.
A dedicated mobile application (APP) for Android and iOS allows users to monitor battery status, modify parameters, and control charge/discharge switches via Bluetooth. Its compact size, ease of operation, and comprehensive functionality make it suitable for a wide range of applications, including small sightseeing vehicles, mobility scooters, shared cars, high-power energy storage systems, base station backup power supplies, and solar power stations.
2. Functional Characteristics
The JIKONG Smart BMS offers a robust set of features to ensure optimal battery performance and safety:
- LED Bluetooth status indicator
- APP Bluetooth remote operation
- Battery capacity calculation
- High precision voltage acquisition (±3mV)
- High precision current acquisition
- Support information screen display
- Accurate time logging
- Support RS485 (Optional)
- Support CAN (Optional)
- Support ACC detection function (Optional)
- Support heating function (Optional)
- Support parallel function
- Support alarm function (Optional)
- Support concatenation function
- Support GPS communication
- Charge overcurrent protection
- Charge overvoltage protection
- Charge over temperature protection
- Low temperature protection during charge
- Discharge overcurrent protection
- Discharge undervoltage protection
- Discharge over temperature protection
- Short circuit protection
3. Unboxing and Package Contents
Upon receiving your JIKONG Smart BMS, please inspect the package for any damage. The standard package includes the following items:

- BMS Unit (JK-BD6A24S20PD) x 1
- Sampling Line (70cm) x 1
- NTC Temperature Sensor (40cm) x 1
- Switch (50cm) x 1

4. Specifications
4.1. Basic Parameters
| Parameter | Value | Unit |
|---|---|---|
| Supply Voltage | 7.5-36 | V |
| Series Withstand Voltage | 100 | V |
| Operating Power Consumption | <1300 | mW |
| Operating Temperature | -30-70 | °C |
| Maximum Number of Collection Strings | 8 | String |
| Maximum Balancing Current | 0.6 | A |
| Maximum Charging Current | 200 | A |
| Maximum Discharge Current | 200 | A |
| Maximum Instantaneous Current | 400 | A |
| Maximum Internal Loop Resistance | 0.35 | mΩ |
| Protective Plate Size | 152.25 x 127.26 x 15.6 | mm |
| Finished Weight | 424 | g |
| Supported Maximum Series Battery Pack | 12V (6 pack), 24V (3 pack) |
4.2. Default Parameters
The following table outlines the default parameter settings for different battery types. These can be adjusted via the APP.
| Parameter | Li-ion | LiFePO4 | LTO | Unit |
|---|---|---|---|---|
| Balancing Initial Voltage | 3 | 3 | 2 | V |
| Maximum Balancing Current | 2 | 2 | 2 | A |
| Unit Overcharge Voltage | 4.2 | 3.6 | 2.7 | V |
| Single Overcharge Protection Recovery | 4.18 | 3.55 | 2.65 | V |
| Monomer Undervoltage Protection | 2.82 | 2.6 | 1.8 | V |
| Single Undervoltage Protection Recovery | 2.85 | 2.65 | 1.85 | V |
| Automatic Shutdown Voltage | 2.8 | 2.5 | 1.7 | V |
| SOC-0% Voltage | 2.9 | 2.6 | 1.85 | V |
| SOC-100% Voltage | 4.18 | 3.5 | 2.65 | V |
| Trigger Balancing Differential Pressure | 0.01 | 0.01 | 0.01 | V |
| Charging Overcurrent Protection Delay | 30 | 30 | 30 | S |
| Charge Overcurrent Protection Release Time | 60 | 60 | 60 | S |
| Discharge Overcurrent Protection Delay | 300 | 300 | 300 | S |
| Discharge Overcurrent Protection Release Time | 60 | 60 | 60 | S |
| Short-circuit Protection Delay | 5 | 5 | 5 | uS |
| Charging Overtemperature Protection | 70 | 70 | 70 | °C |
| Charging Overtemperature Restore | 60 | 60 | 60 | °C |
| Discharge Overtemperature Protection | 70 | 70 | 70 | °C |
| Discharge Overtemperature Recovery | 60 | 60 | 60 | °C |
| Charging Low Temperature Protection | -20 | -20 | -20 | °C |
| Charging Low Temperature Restore | -10 | -10 | -10 | °C |
| MOS Overtemperature Protection | 100 | 100 | 100 | °C |
| MOS Overtemperature Recovery | 80 | 80 | 80 | °C |
| Device Address | 0 | 0 | 0 | / |
4.3. Product Dimensions
The dimensions of the JK-BD6A24S20PD protection board are 152.25mm x 127.26mm x 15.6mm.


5. Setup and Installation
5.1. Interface Definition
Understanding the various interfaces is crucial for correct installation. The BMS features multiple ports for balancing, communication, temperature sensing, and more.

P1: Balancing and Acquisition Interface (XH-10AW-2.54)
| Pin | Name | Definition |
|---|---|---|
| 1 | B- | Total negative battery terminal |
| 2 | B1 | First battery positive terminal |
| ... | ... | ... (Up to B8 for 8S) |
| 10 | B+ | Protection board power supply, connected to the battery total positive |
P2: Buzzer Interface (Optional, A1254WF-2A)
| Pin | Name | Definition |
|---|---|---|
| 1 | GND | Buzzer power negative |
| 2 | VCC | Buzzer power supply positive |
P3: Communication Interface (Optional, A1254WF-4A)
| Pin | Name | Definition |
|---|---|---|
| 1 | CAN L | CAN signal negative terminal |
| 2 | CAN H | CAN signal positive terminal |
| 3 | RS485 A | RS485 signal positive terminal |
| 4 | RS485 B | RS485 signal negative terminal |
P4: UART Interface (1.25T-4PWT)
| Pin | Name | Definition |
|---|---|---|
| 1 | GND | Power/signal ground |
| 2 | RX | UART RX, 3.3V |
| 3 | TX | UART TX, 3.3V |
| 4 | VGPS | Power output, voltage close to B+ |
P5: 4-Way External Temperature Interface (Optional, HY2.0-4P)
| Pin | Name | Definition |
|---|---|---|
| 1 | T3A | Third temperature sensor pin A |
| 2 | T3B | Third temperature sensor pin B |
| 3 | T4A | Fourth temperature sensor pin A |
| 4 | T4B | Fourth temperature sensor pin B |
P6: Temperature Interface (HY2.0-4P)
| Pin | Name | Definition |
|---|---|---|
| 1 | T1A | First temperature sensor pin A |
| 2 | T1B | First temperature sensor pin B |
| 3 | T2A | Second temperature sensor pin A |
| 4 | T2B | Second temperature sensor pin B |
P7: Display Interface (A1254WF-6A)
| Pin | Name | Definition |
|---|---|---|
| 1 | K- | Activation signal negative electrode |
| 2 | K+ | Activation signal positive electrode |
| 3 | GND | Power negative terminal |
| 4 | B | Display RS485 signal negative |
| 5 | A | Display RS485 signal positive |
| 6 | VCC | Display power output |
P8: Parallel Interface (A1254WF-3A)
| Pin | Name | Definition |
|---|---|---|
| 1 | P-status | Parallel module status signal |
| 2 | P-EN | Parallel module enable signal, output low level to enable parallel module |
| 3 | GND | Signal ground |
P9: ACC Interface (Optional, A1254WF-5A)
| Pin | Name | Definition |
|---|---|---|
| 1 | C_Detect- | Charger output 12V negative |
| 2 | C_Detect+ | Charger output 12V positive |
| 3 | NC | Not connected (Empty) |
| 4 | ACC- | ACC Negative |
| 5 | ACC+ | ACC Positive |
Heating Wire (16AWG-Orange-15CM)
| Pin | Name | Definition |
|---|---|---|
| 1 | HT- | Heater element negative electrode |
D1: Bluetooth Connection Indicator
- When Bluetooth is connected to the protection board, the indicator is steady on.
- When the connection is disconnected, the indicator is blinking.
5.2. Installation Method
The JK-BD6A24S20PD series protection board is suitable for 3-8 series lithium battery packs. The wiring method varies depending on the number of cells. Refer to the diagram below for specific wiring instructions.




Pre-installation Checklist:
- Ensure the balance cable is properly connected.
- Verify that P- and B- terminals are correctly connected.
- Confirm that the protection board is securely fixed to the battery pack.
- Failure to follow these steps may lead to abnormal operation or damage to the BMS.
Powering On and Activation:
- The BMS does not have a power-on control switch. It is designed for charging activation.
- After the battery assembly is complete, connect the charger. The charger voltage must be 2V higher than the battery voltage for the BMS to activate.
- Alternatively, if you have an optional display screen and button, connect them to the display interface and press the button to activate the BMS.
6. Operation and Functions
6.1. Active Equalization
The BMS uses active equalization technology to transfer energy from high-voltage cells to low-voltage cells. Before using this function, set basic battery parameters (number of cells, battery capacity, trigger equalization differential pressure, voltage calibration, current calibration) in the APP. The default balance current is 0.6A. Users can adjust the balance current based on their battery capacity. The equalization function automatically activates when the voltage difference between any two battery strings exceeds the set value and turns off when it falls below the set value. This function can also be manually disabled via the APP.6.2. UART and Display Interface
The BMS includes a UART port for optional GPS connectivity, allowing for battery location tracking. It also has a dedicated display interface for connecting an optional display screen to view real-time battery information. Users can select these options based on their specific needs.6.3. Heating Function (Optional)
For low-temperature environments, the BMS supports an optional heating function using a resistance heater or heating film. This prevents reduced battery activity and ensures proper charging/discharging. The designed heating current is 20A. Users can control this function via the APP. It is recommended to install a temperature control switch (45°C to 65°C normally closed) in series with the heating circuit as a secondary safety measure.6.4. Alarm Function (Optional)
The BMS can be configured with an alarm function to provide external alerts when safety risks such as overtemperature, overcharge, or over-discharge are detected.6.5. Battery Parallel Function
The BMS supports parallel battery pack functionality, which requires a parallel module for synchronization. This function can be enabled by disabling the 'disable charging current limiting' option in the APP.6.6. ACC Detection Function (Optional)
This function enables discharge. It can be activated by applying a voltage (20V-100V) between ACC+ and ACC- or by short-circuiting ACC+ and ACC-. Additionally, the BMS has C_detect+ and C_detect- interfaces for charger detection, which connect to the charger's 12V voltage signal to enable charging.6.7. Protection Functions
The BMS incorporates several critical protection features:
- Charge Overvoltage Protection: Prevents battery overcharging by shutting off charging when any cell exceeds the set overvoltage protection voltage. Charging resumes when all cells recover to the set recovery voltage.
- Discharge Undervoltage Protection: Prevents over-discharge by stopping discharge when any cell falls below the set undervoltage protection voltage. Discharge resumes when all cells recover to the set recovery voltage. If any cell falls below the automatic shutdown voltage, the BMS will shut down completely.
- Charge Overcurrent Protection: Protects against excessive charging current. If the charging current exceeds the set continuous charging current for a specified delay, charging is stopped. It resumes after a set release time.
- Discharge Overcurrent Protection: Protects against excessive discharging current. If the discharge current exceeds the set continuous discharge current for a specified delay, discharge is stopped. It resumes after a set release time. (Maximum continuous discharge current should not exceed 200A).
- Overtemperature Protection: Monitors battery temperature during charge and discharge. If the temperature exceeds the set overtemperature protection value, the respective operation (charge or discharge) is halted. It resumes when the temperature falls below the recovery value.
- Low Temperature Protection: Protects against charging at dangerously low temperatures. If the temperature falls below the set low temperature protection value, charging is stopped. It resumes when the temperature rises above the recovery value. For extremely cold regions, the optional heating function is recommended.
- Short Circuit Protection: Automatically protects against short circuits. Users can set the short circuit protection delay and recovery time via the APP. If a short circuit occurs during charging or discharging, the BMS will temporarily halt the operation and resume after the recovery time. Adjusting the delay can help prevent false triggers from high peak currents during charger startup or large load capacitance.
6.8. Emergency Switch
In situations like overtemperature, over-discharge, overcharge, or cell string drops, activating the emergency switch in the APP will force the BMS to enable both charge and discharge for 30 minutes. This provides a critical window for emergency use, even if a single cell reaches its automatic shutdown voltage, preventing unexpected power loss.6.9. Intelligent Sleep
The intelligent sleep function helps reduce the BMS's self-consumption. If the charge/discharge current is less than 1A for 26 consecutive hours, the BMS enters a standby state. It can be reactivated by pressing a button or connecting a charger.6.10. Communication Function
The BMS supports optional CAN and RS485 communication. Users can select between CAN or RS485 via the APP's BMS control page. Address and communication protocols can be configured based on specific application requirements. Refer to the JIKONG Protection Board communication protocol document for detailed information.
7. APP Operation Instructions
7.1. APP Installation
To download the mobile APP compatible with your JIKONG Smart BMS, scan the QR code below. An Android device with version 7 or higher is required.

7.2. Parameter Setting
Detailed instructions for setting parameters within the APP can be found in the "Instructions for Setting Protection Board Parameters" document. This document provides comprehensive guidance on configuring various operational and protection settings to match your specific battery setup and application needs.
8. Maintenance
Regular maintenance of your JIKONG Smart BMS involves monitoring its performance through the mobile APP and ensuring all connections remain secure. Periodically check for any loose wires or signs of wear on the balance cables and main power connections. Keep the BMS unit clean and free from dust or moisture. Ensure the NTC temperature sensors are properly placed to accurately monitor battery temperatures.
For optimal performance and longevity, ensure that the battery pack is operated within the specified voltage, current, and temperature ranges as defined in the specifications and default parameters. Any significant deviations should be investigated and corrected promptly.
9. Troubleshooting
If you encounter issues with your JIKONG Smart BMS, refer to the following general troubleshooting steps:
- BMS Not Activating: Ensure the charger voltage is at least 2V higher than the battery pack voltage. Check all connections, especially P- and B-, and balance cables. If using an optional display, try activating via the button.
- Protection Triggered (Overvoltage, Undervoltage, Overcurrent, Overtemperature): Check the APP for specific fault codes or alerts. Verify individual cell voltages and temperatures. Ensure the load or charger is within the BMS's current limits. Allow sufficient recovery time as per default parameters.
- Short Circuit Protection: If triggered, disconnect the load/charger and inspect for actual short circuits in the wiring. If no physical short is found, consider increasing the short circuit protection delay in the APP, especially if using loads with high inrush current.
- Balancing Issues: Confirm that active balancing is enabled in the APP and that the trigger differential pressure is set appropriately. Check balance cable connections for integrity.
- Communication Problems (Bluetooth/UART/CAN/RS485): Ensure the APP is correctly installed and Bluetooth is enabled on your mobile device. Check physical connections for UART/CAN/RS485 modules. Verify communication protocol settings in the APP.
- Heating Function Not Working: Check if the heating function is enabled in the APP. Inspect the heating element and the temperature control switch for proper connection and functionality.
For more detailed troubleshooting, consult the comprehensive PDF manual referenced in the Additional Resources section.
10. User Tips
No specific user tips are available at this time. For best performance, always ensure proper installation and configuration according to the manual.
11. Warranty and Support
For warranty information and technical support, please refer to the official JIKONG documentation or contact the seller directly. Keep your purchase records for any warranty claims.
12. Additional Resources
A comprehensive user manual in PDF format is available for detailed instructions and technical specifications. You can access it here: JIKONG Smart BMS User Manual (PDF).