Yingcai K4 K2 Electrolysis Needles User Manual

24ct Gold Plated, Sterile Hair Removal Needles

1. Introduction

The Yingcai K4 and K2 Electrolysis Needles are professional-grade, 24ct gold-plated, sterile, single-use filaments designed for effective and permanent hair removal. These needles are compatible with various professional electrolysis machines, including the Yingcai TG01, TG03, and TG09 models. This manual provides essential information for the safe and proper use, maintenance, and disposal of these electrolysis needles.

⚠️ Professional Use Only: This product is intended for use by licensed electrologists, dermatologists, and certified beauty professionals. Not intended for home use by consumers without proper training.

2. Safety Information and Warnings

  • Sterility: Each needle is individually sealed and pre-sterilized. Do not use if the individual packaging is opened, damaged, or if the sterilization date has expired.
  • Single-Use: For optimal hygiene and to prevent cross-contamination, each needle is strictly for single-use on a single client. Dispose of the needle immediately after use.
  • Storage: Store needles in a cool, dry place, away from moisture and direct sunlight.
  • Disposal: Used needles are considered sharps waste. Always dispose of them safely in a designated, puncture-resistant "SHARPS WASTE" container immediately after use.
  • Handling: Handle needles with care to prevent accidental punctures. Always use appropriate personal protective equipment (PPE), such as gloves.
Warning signs for electrolysis needles: Professional use only, do not use if packaging is opened or damaged, do not expose to moisture or direct sunlight.
Important warnings regarding professional use, packaging integrity, and storage conditions.

3. Key Features and Benefits

  • 24ct Gold-Plated Surface: Provides superior electrical conductivity, is hypoallergenic, and corrosion-resistant, ensuring stable current delivery.
  • Ultra-Fine Diameter: K4 needles feature a 0.100mm diameter, and K2 needles feature a 0.055mm diameter, ensuring minimal discomfort and precise targeting of hair follicles.
  • Pre-Sterilized & Single-Use: Guarantees optimal hygiene and safety for every client.
  • Universal 0.80mm Shank Compatibility: Designed to fit most professional electrolysis machines, including Yingcai TG01, TG03, and TG09.
  • Professional Grade: Widely used in dermatology clinics, medical spas, and beauty training schools. Electrolysis is the only FDA-approved method for permanent hair removal.
  • Convenient Packaging: Each box contains 50 filaments (5 boards of 10 needles each), ready for immediate use.
Diagram showing key features and benefits of Yingcai electrolysis needles, including 24ct gold-plated surface, ultra-fine 0.100mm diameter, pre-sterilized, single-use, and 0.80mm shank size.
Visual representation of the key features and benefits of the electrolysis needles.

4. Setup Instructions

  1. Inspect Packaging: Before opening, visually inspect the individual needle packaging to ensure it is sealed and undamaged. Verify the expiration date.
  2. Prepare Handpiece: Ensure your electrolysis machine's handpiece is clean and ready for needle insertion.
  3. Insert Needle: Carefully open the sterile packaging and insert a new needle into the compatible electrolysis handpiece. Ensure it is securely seated.
  4. Machine Compatibility: These needles are designed with a 0.80mm shank size for broad compatibility. Refer to your electrolysis machine's manual for specific needle insertion procedures. Compatible machines include Yingcai TG01, TG03, and TG09.
Diagram showing usage instructions: Check packaging, use a new needle, insert needle into handpiece, and dispose safely.
Step-by-step visual guide for preparing and using the electrolysis needles.
Images of compatible electrolysis machines: TG01, TG03, TG09.
Examples of compatible electrolysis machines (TG01, TG03, TG09).

5. Operating Instructions

Electrolysis is a precise procedure that requires professional training. The following describes the general principle of operation:

  1. Client Preparation: Prepare the client's skin according to standard electrolysis protocols.
  2. Needle Insertion: Gently insert the ultra-fine needle into the hair follicle opening, following the natural direction of hair growth. The precision tip allows for accurate targeting.
  3. Current Delivery: Activate the electrolysis machine to deliver a tiny electrical current through the gold-plated needle to the hair follicle. The gold plating ensures optimal conductivity for effective treatment.
  4. Follicle Destruction: The electrical current destroys the hair follicle's ability to regrow hair, leading to permanent hair removal.
  5. Hair Removal: Once the follicle is treated, the hair can be gently removed with tweezers.
Diagram illustrating how electrolysis works: 1. Needle inserted into follicle. 2. Electrical current applied. 3. Follicle destroyed. 4. Hair removed.
Illustration of the electrolysis process for permanent hair removal.
Images showing various treatment areas for electrolysis: armpit, face, bikini, body, leg, arm.
Common treatment areas where these electrolysis needles can be effectively used.
Before and after images demonstrating the treatment effect of electrolysis on various body parts.
Visual results of electrolysis treatment.

6. Maintenance

These electrolysis needles are single-use and require no maintenance other than proper storage and disposal.

  • Storage: Keep unused needles in their original, unopened packaging in a cool, dry environment, away from direct sunlight and moisture.
  • Disposal: After each use, immediately place the used needle into a designated sharps container. Do not attempt to recap, bend, or break used needles.
Image showing safe disposal of a used needle into a sharps waste container.
Proper disposal of used needles in a sharps waste container.

7. Troubleshooting

  • Needle appears dull or bent: Do not use. A damaged needle can cause discomfort, ineffective treatment, or skin trauma. Discard and use a new, intact needle.
  • Packaging is compromised: If the sterile packaging is torn, punctured, or opened, do not use the needle. Its sterility cannot be guaranteed.
  • Difficulty inserting needle into handpiece: Ensure the needle's shank size (0.80mm) matches the handpiece specifications. Do not force the needle; check for obstructions or compatibility issues.
  • Ineffective treatment: Ensure the needle is correctly inserted into the follicle and that the electrolysis machine is functioning properly and set to appropriate parameters.

8. Specifications

Attribute Detail
Product Type Electrolysis Needles
Models K4, K2
Needle Material 24ct Gold Plated
Needle Diameter (K4) 0.100mm (0.004")
Needle Diameter (K2) 0.055mm
Shank Size 0.80mm
Quantity per Box 50 Filaments (Needles)
Sterilization Pre-Sterilized
Usage Single-Use
Compatibility Yingcai TG01, TG03, TG09, and other professional electrolysis machines with 0.80mm shank.
Origin Mainland China
Portable Yes
Yingcai K4 G Electrolysis Needles packaging showing specifications like 0.100mm diameter and 0.80mm shank.
Product packaging detailing K4 needle specifications.
Image of K2 needles, indicating K2=0.055MM diameter.
K2 needle variant with 0.055mm diameter.

9. User Tips

  • Sharpness for Effectiveness: Users report that these needles are very sharp, contributing to effective hair removal. Ensure the needle remains sharp and undamaged for optimal results.
  • Strict Hygiene: Always adhere to the single-use policy for each needle per client to maintain the highest standards of hygiene and prevent any risk of cross-contamination.
  • Machine Compatibility Check: Confirm that the 0.80mm shank size is compatible with your specific electrolysis machine model (e.g., TG03) before use.

10. Warranty and Support

For any questions regarding the product, its performance, or for technical support, please contact your distributor or the Yingcai Beauty Machine Store directly. Please retain your purchase records for any warranty claims or support inquiries.

© 2023 Yingcai Beauty Instrument Co., Ltd. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.