1. Introduction
1.1 Purpose and Scope
This manual describes the assembly, installation, operation, and troubleshooting of the Daxtromn AGH-8.2KW-48V Hybrid Solar Inverter. Please read this manual carefully before installation and operation. Keep this manual for future reference. It provides safety and installation guidelines, as well as information on tools and wiring.
1.2 Key Features
- Pure sine wave solar inverter (on/off Grid)
- Output power factor 1.0
- WIFI available for iOS and Android
- Inverter running without battery
- One-key restoration to factory settings
- Built-in Lithium battery automatic activation
- Built-in 160A MPPT solar charger
- High PV input voltage range (90~450VDC)
- Built-in anti-dust kit for harsh environments
- Smart battery charge design to optimize battery life
- Touch button interface
- Dual AC Output function
2. Safety Instructions
WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.
- Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
- CAUTION: To reduce risk of injury, charge only deep-cycle lead acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
- Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
- To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
- CAUTION: Only qualified personnel can install this device with battery.
- NEVER charge a frozen battery.
- For optimum operation, follow required specifications to select appropriate cable size.
- Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts and cause an explosion.
- Strictly follow installation procedures when disconnecting AC or DC terminals.
- One 150A fuse is provided as over-current protection for the battery supply.
- GROUNDING INSTRUCTIONS: This inverter/charger should be connected to a permanent grounded wiring system. Comply with local requirements and regulations.
- NEVER cause AC output and DC input short circuited. Do NOT connect to the mains when DC input short circuits.
- Warning: Only qualified service persons are able to service this device. If errors persist after troubleshooting, send this inverter/charger back to local dealer or service center.
3. Product Overview
The Daxtromn AGH-8.2KW-48V is a multi-function inverter/charger, combining inverter, solar charger, and battery charger functions. Its comprehensive LCD display offers user-configurable and easy-accessible button operation.
3.1 Basic System Architecture
The inverter connects solar power, a generator or utility, and external battery packs to power home appliances. The charging voltage for external battery packs is adjustable.

3.2 Product Components
The inverter features an LCD display, various indicators, touch function buttons, and multiple input/output ports.

- LCD display
- Status indicator
- Charging indicator
- Fault indicator
- Touch Function buttons
- Power on/off switch
- AC input
- Main output
- Second output
- PV1 and PV2 input
- WIFI communication/RS-232 port
- Battery communication/RS-485 port
- Battery input
- Anti dust kit
4. Setup and Installation
4.1 Unpacking and Inspection
Before installation, inspect the unit for any damage. The package should contain: The inverter unit (x1), User manual (x1), Ring terminal (x1), Mc4 terminal head (x2).
4.2 Preparation and Mounting
Before connecting any lines, remove the screws under the machine and remove the bottom cover plate.
CAUTION: Suitable for mounting on concrete or other non-combustible surface only.
- Do not mount on flammable construction materials.
- Mount on a solid surface at eye level for LCD visibility.
- Allow approx. 20 cm clearance on sides and 50 cm above/below for air circulation.
- Ambient temperature should be between 0°C and 55°C.
- Install vertically on the wall.
- Ensure enough space for heat dissipation and wire removal.
Install the unit using M4 or M5 screws.
4.3 Battery Connection
WARNING: Shock Hazard. Installation must be performed with care due to high battery voltage in series.
Install a separate DC over-current protector or disconnect device between battery and inverter. Refer to the table below for required fuse or breaker size. All wiring must be performed by qualified personnel using appropriate cables.
| Model | Wire Size | Cable (mm²) | Torque Value (max) |
|---|---|---|---|
| 8.2KW/10.2KW | 1 x 2AWG | 25 | 2 Nm |
Connection Steps:
- Remove 18 mm insulation sleeve from positive and negative conductors.
- Use bootlace ferrules on wire ends with a proper crimping tool.
- Connect all battery packs as shown in the diagram below.
- Insert battery wires into inverter connectors, tighten bolts to 2 Nm. Ensure correct polarity. Recommended tool: #2 Pozi Screwdriver.

4.4 AC Input/Output Connection
CAUTION: Install a separate AC breaker between inverter and AC input power source. Do NOT mis-connect input and output connectors.
Recommended AC breaker spec is 63A for 8.2KW/10.2KW. All wiring must be performed by qualified personnel using appropriate cables.
| Model | Gauge | Cable (mm²) | Torque Value |
|---|---|---|---|
| 8.2KW/10.2KW | 10 AWG | 6 | 1.2 Nm |
Connection Steps:
- Before connecting, open DC protector or disconnector.
- Remove 10mm insulation sleeve for six conductors. Shorten phase L and neutral N by 3mm.
- Insert AC input wires according to polarities (Ground: yellow-green, L: brown/black, N: blue) and tighten screws.
- Insert AC output wires according to polarities (L: brown/black, N: blue) and tighten screws.
- Ensure all wires are securely connected.
4.5 PV Connection
CAUTION: Install a separate DC circuit breaker between inverter and PV modules.
All wiring must be performed by qualified personnel using appropriate cables.
| Model | Wire Size | Cable (mm²) | Torque Value (max) |
|---|---|---|---|
| 8.2KW/10.2KW | 1 x 10AWG | 6 | 1.2 Nm |
PV Module Selection: Consider the following parameters:
- Open circuit Voltage (Voc) of PV modules must not exceed max. PV array open circuit voltage of inverter (500Vdc).
- Open circuit Voltage (Voc) of PV modules should be higher than min. battery voltage.
| INVERTER MODEL | 8.2KW/10.2KW |
|---|---|
| Max. PV Array Open Circuit Voltage | 500Vdc |
| PV Array MPPT Voltage Range | 90Vdc~450Vdc |

PV Module Wire Connection Steps:
- Check PV array input voltage (120VDC - 500VDC). Max current load per PV input connector is 10A.
- Disconnect the DC circuit breaker.
- Assemble provided PV connectors with PV modules (strip 8mm cable, crimp terminals, assemble housings).
- Check correct polarity and connect positive (+) to positive (+) and negative (-) to negative (-) of PV input connector.
4.6 Communication Connection
The inverter supports Wi-Fi, GPRS, and battery communication.
- Wi-Fi/GPRS Cloud Communication: Use supplied communication cable to connect to inverter and module. Download APP, set up network, and register. Inverter status will be shown on mobile APP or webpage.
- Battery Communication: Communication between battery and inverter is via the battery communication interface (Baud rate: 9600). Use power and communication cables. Ensure correct polarity. Connect RJ45 to BMS port on inverter and RS485 port on lithium battery. Turn off battery and inverter before connecting.
5. Operation
5.1 Power ON/OFF
Once the unit is properly installed and batteries are connected, simply press the On/Off switch (located on the button of the case) to turn on the unit.
5.2 Operation and Display Panel
The front panel includes three indicators, four function keys, and an LCD display showing operating status and power information.
| Indicator | Color | Status | Message |
|---|---|---|---|
| INV/AC | Green | Solid On Flashing | Output powered by utility (Line mode) Output powered by battery or PV (Battery mode) |
| CHG | Green | Solid On Flashing | Battery fully charged Battery is charging |
| FAULT | Red | Solid On Flashing | Fault occurs in inverter Warning condition occurs in inverter |
| Function Key | Description |
|---|---|
| ESC | To exit setting mode |
| UP | To go to previous selection |
| DOWN | To go to next selection |
| ENTER | To confirm selection or enter setting mode |
5.3 LCD Settings
Press and hold the ENTER button for 3 seconds to enter setting mode. Use UP/DOWN to select programs, then ENTER to confirm or ESC to exit.


5.4 Various Working Modes
The inverter supports various working modes, including operation without battery connected and operation with battery connected, adapting to different power supply scenarios.

6. Maintenance
6.1 Clearance and Maintenance for Anti-Dust Kit
The inverter comes with a factory-installed anti-dust kit to protect against dust and increase reliability. This kit should be cleaned regularly.
Maintenance Steps:
- Loosen the screw on the top of the inverter in a counterclockwise direction.
- Remove the dustproof case and take out the air filter foam.
- Clean the air filter foam and dustproof case.
- Re-assemble the dust-kit back to the inverter.
NOTICE: The anti-dust kit should be cleaned from dust every one month.
7. Troubleshooting
This section provides guidance for common issues and fault codes.
7.1 Fault Reference Codes
The inverter displays specific codes for various faults. Refer to the manual for a comprehensive list of fault codes and their corresponding events and solutions.
7.2 Warning Indicators
Warning codes indicate non-critical conditions that may require attention. These are typically accompanied by audible alarms or flashing icons.
7.3 Common Troubleshooting Scenarios
| Problem | Explanation / Possible Cause | What to Do |
|---|---|---|
| Unit shuts down automatically during startup | Battery voltage too low (<1.91V/Cell) | 1. Re-charge battery. 2. Replace battery. |
| No response after power on | 1. Battery voltage too low (<1.4V/Cell) 2. Internal fuse tripped | 1. Contact repair center for fuse replacement. 2. Re-charge battery. 3. Replace battery. |
| Mains exist but unit works in battery mode | Insufficient quality of AC power (Shore or Generator) | 1. Check if AC wires are too thin/long. 2. Check generator/input voltage range setting. |
| Buzzer beeps continuously and red LED is on | Overload error, Battery over-charged, Fan fault, Output abnormal, Internal components failed, Over current/surge, Bus voltage too low, Output voltage unbalanced | Reduce load, Return to repair center, Replace fan, Restart unit. |
8. Specifications
Detailed technical specifications for the Daxtromn AGH-8.2KW-48V Hybrid Solar Inverter are provided below.

8.1 General Specifications
- Model Number: AGH-8.2KW-48V
- Rated Power: 8200W
- Max. PV Array Power: 5400W x 2
- Max Charge Current: 160A
- PV Working Voltage: 90-500Vdc
- Output Voltage: 220-240V AC
- Output Frequency: 50Hz
- Output Type: DUAL
- Output Voltage Waveform: Pure Sine Wave
- Battery Voltage: 48V
- Dimensions (D*W*H): 500*390*136mm
- Net Weight: 14.5kg
- Operating Temperature: -10°C to 50°C
- Certification: CE
9. User Tips
- When operating without an external battery, ensure the solar panel voltage is above 120V for normal inverter operation. If an external battery is connected, 90V is sufficient.
- The inverter supports connecting two strings of solar panels with different specifications.
- For battery communication, the inverter supports PACE and PYLON BMS protocols.
- This model does not support parallel or series connection with other inverters.
10. Warranty and Support
The Daxtromn AGH-8.2KW-48V Hybrid Solar Inverter comes with a 1-year warranty. For technical support, service, or warranty claims, please contact your authorized dealer or the manufacturer directly.
11. Frequently Asked Questions (FAQ)
- Q: What is the Rated output power?
A: It is 8200W. - Q: What is the max charge current for the battery?
A: It is 160A. - Q: What is the MAX DC PV Input?
A: It is 500VDC. - Q: How many volts of external battery does it use?
A: 48V. - Q: Can I connect two strings of solar panels of different specifications?
A: Yes. - Q: What BMS protocols are supported?
A: PACE and PYLON. - Q: Can it support parallel or series connection?
A: No, it cannot support parallel or series connection. - Q: Does it have a Wifi Model?
A: Yes. - Q: Does it feed power to the grid?
A: Yes, it is an on/off grid solar inverter, a real hybrid inverter.