MYOSLIM CL-013

Contents

MYOslim EMS Body Sculpt Machine

Model: CL-013 | Brand: MYOSLIM

When operating this product, please read this manual carefully first.

1. Introduction

The MYOslim EMS Body Sculpt machine, Model CL-013, utilizes advanced HI-EMT (High-Intensity Focused Electromagnetic) technology to induce powerful muscle contractions. This process aims to promote muscle growth, reshape internal muscle structure, and trigger fat breakdown through intense muscle activity. The device also incorporates warm physical techniques for comprehensive body sculpting benefits.

Key Technologies:

  • Advanced HI-EMT Technology: Employs high-energy focused electromagnetic waves to achieve intense muscle contractions, promoting muscle growth, and deep internal structural reshaping.
  • Touch-Controlled Display: Simplifies device operation with clear visibility and adjustable brightness, guiding users through the treatment process.
  • Real-time Monitoring and Guidance: The display shows remaining treatment time, utilized channels, treatment methods, applied treatment types, and attachments, aiding in monitoring and guidance.
  • Upgradeability: Offers flexible upgrade options to meet future therapeutic needs.

Indications for Use:

The EMS Body Sculpt machine is intended for:

  1. Improvement of abdominal tone, strengthening of abdominal muscles, and development of a fitter abdomen.
  2. Strengthening, toning, and firming of buttocks, thighs, and calves.
  3. Improvement of muscle tone and firmness, for strengthening muscles in arms.

Operating Environment:

To ensure effectiveness and safety, the operating environment should be:

  • Clean and Hygienic: Prevent external contamination and bacterial infections. Regular cleaning and disinfection of equipment and accessories are essential.
  • Appropriate Temperature and Humidity: Maintain temperature and humidity within the manufacturer's specified range to avoid impacting device performance.
  • Adequate Lighting: Ensure sufficient lighting for clear operation and correct equipment usage.
  • Good Ventilation: Provide adequate ventilation to ensure air circulation and prevent accumulation of harmful gases.

2. Important Safety Information

DANGER: Risk of Electric Shock

Do not open the device casing. No user-serviceable parts inside. Refer servicing to qualified personnel only.

CAUTION: General Safety Guidelines

  • This device is for adult use only. Do not use on minors or individuals without a health clearance certificate.
  • Remove all metal jewelry before operation. Avoid contact with open wounds.
  • Do not use on a full stomach. Allow at least 1 hour after meals and refrain from eating/drinking during and 1 hour post-treatment.
  • Never replace the treatment handle while the device is powered on. Always turn off the power and calibrate the handle before replacement.
  • Keep away from strong electromagnetic sources. Do not daisy-chain multiple devices on a single power outlet.
  • This product is intended to be used in dry areas only.

Contraindications:

Do not use this device if any of the following conditions apply:

  • Wounds on the skin (or avoid using on wounded areas).
  • Patients with heart disease (such as those with arrhythmias), especially those with pacemakers.
  • Cancer patients.
  • Patients with infectious diseases.
  • Pregnant women, lactating women, or during menstrual period.
  • Major surgery patients, diabetic patients.
  • Having any metal in the body.
  • People with cerebrovascular disease (stroke patients).

Possible Side Effects:

These effects may include but are not limited to:

  • Muscle soreness.
  • Reduction in muscle fat.
  • Temporary muscle spasms.
  • Transient joint or muscle tendon pain.
  • Localized redness or skin flushing.

European Conformity (CE)

The CE symbol indicates that this product conforms with all relevant EU health, safety, and environmental protection regulations.

3. Setup and Basic Device Operation

Device Overview:

MYOslim EMS Body Sculpt Machine with a muscular man in the background
Figure 3.1: MYOslim EMS Body Sculpt Machine (Model CL-013)
Front view of the MYOslim EMS Body Sculpt machine with two handles attached.
Figure 3.2: Front view of the MYOslim EMS Body Sculpt machine.
Rear view of the MYOslim EMS Body Sculpt machine showing power input and fan vents.
Figure 3.3: Rear view of the MYOslim EMS Body Sculpt machine.

3.1 Handle Exchange

The handle must be calibrated every time it is installed or replaced. When replacing the handle, you must turn off the power of the machine. The handle cannot be replaced when the machine is powered on.

3.2 Device Start-Up/Shut-Down

  1. Connect one end of the power cord to the machine and plug the other end into the main socket. Do not connect multiple machines to the same socket.
  2. Move the manual switch on the rear panel to the "o" position (ON).
  3. Press the power button on the front panel to turn on the device.
  4. When the treatment is finished, press and hold the power button to turn off the machine.
Video 3.1: Demonstration of device power-on, handle attachment, and basic interface navigation.

3.3 Navigation Controls & Unit Settings

The device features a touch-controlled display for easy navigation and setting adjustments. Pre-treatment regimens can be modified via on-screen controls. The treatment interface displays various items and functions, including:

  • Language Settings: Supports English, Spanish, French, German, Chinese, Russian, Arabic, etc.
  • Sound Adjustment: Control device audio feedback.
  • Brightness Adjustment: Adjust screen brightness for optimal visibility.
  • Set Date & Time: Configure the device's internal clock.
  • System Information: View device serial number, software version, and operating time.
  • Technician Access: Password-protected access for technical adjustments.
Touchscreen interface showing language selection options.
Figure 3.4: Touchscreen interface for language settings.
Touchscreen interface showing date and time settings.
Figure 3.5: Touchscreen interface for date and time settings.

Note: Adjust the corresponding intensity according to different customer needs. If the customer requests to pause, you can click start/pause. The work button suspends the work, and you can directly click the back button to return after the work is completed.

4. Therapy Operation

4.1 Preparing for Therapy

  1. Communicate with patients to understand their needs and comfort levels.
  2. Ensure the patient is in good health and has no contraindications.
  3. Advise the patient to stay hydrated before and after treatment.
  4. Ensure the patient wears appropriate, comfortable clothing.
  5. Advise the patient to avoid eating in large quantities before treatment.
  6. Familiarize yourself with the treatment process and device settings.
  7. Advise the patient to avoid drinking alcohol before treatment.

4.2 Placing the Handle

Proper placement of the treatment handles is crucial for effective therapy. Secure the handles using the provided straps to the target area.

Diagram showing handle placement on the abdomen.
Figure 4.1: Handle placement for abdominal treatment.
Diagram showing handle placement on the buttocks.
Figure 4.2: Handle placement for buttock treatment.
Diagram showing handle placement on the arm.
Figure 4.3: Handle placement for arm treatment.
Diagram showing handle placement on the thigh.
Figure 4.4: Handle placement for thigh treatment.
Diagram showing handle placement on the calf.
Figure 4.5: Handle placement for calf treatment.
Image of the pelvic cushion attachment.
Figure 4.6: Pelvic cushion attachment for pelvic floor training.

Please operate according to the controller model you purchased and follow the manufacturer's official documentation to ensure the best experience. If you have any questions, please contact customer service for support.

5. Maintenance

5.1 Daily Inspection

Regularly inspect the instrument and its components. Ensure the power socket has a reliable connection to the ground. Check for any damage to the power cord before use; discontinue use if damaged.

5.2 Cleaning

  • Surface Cleaning: The device housing can be wiped with a damp cloth, soapy water, or a neutral detergent while the instrument is powered off. Do not use alcohol-based detergents on painted surfaces.
  • Accessory Cleaning: Parts that come into contact with the skin should be cleaned and disinfected with 75% alcohol before and after each use. Do not soak accessories directly in alcohol-based detergent; wipe with pure cotton material.

5.3 Fuse Replacement

To prevent electric shock, always turn off the power and unplug the power plug before replacing the fuse. The fuse is located below the handle junction on the back of the machine. An additional spare fuse is included with the device.

6. Troubleshooting

This table outlines common faults, their potential causes, and recommended workarounds.

Fault Phenomenon Causes Exclusions and Workarounds
Device not working
  • Power plug not inserted into socket
  • Power switch not on
  • Power fuse failure
  • Check the power connection
  • Check the power switch position
  • Replace the fuse
Handle not working
  • Handle is loose
  • Reseat the handle securely

7. Specifications

Attribute Name Attribute Value
High-concerned chemicalnone
Training SiteBODY
Brand Nameemszero
OriginMainland China
Type of sportsMuscle Relexation
Product NameMYOSLIM High-Intensity Electromagnetic Muscle Stimulation System
BrandMYOSLIM
Core TechnologyEMT (Electromagnetic Therapy) + EMS (Electrical Muscle Stimulation) Dual-Mode System
Treatment TypeNon-invasive body sculpting, muscle building, fat reduction, and skin tightening
Primary FunctionSupramaximal muscle contractions for toning, lifting, and shaping
Target AreasAbdomen, buttocks, thighs, arms, back customizable treatment zones
Technology UsedHigh-intensity focused electromagnetic field
Frequency Range20-200 Hz adjustable for optimal muscle stimulation
Muscle ResponseInduces supramaximal contractions (up to 200+ contractions per session)
Energy DeliveryAlternating magnetic field generates induced current in muscle tissue
Nerve ActivationDepolarizes nerve membranes and excites motor units for natural muscle contraction
Skin EffectImproves skin elasticity and reduces sagging through combined EMF + thermal effects
Session Duration20-30 minutes per treatment
Multilingual SupportSupports English, Spanish, French, German, Chinese, Russian, Arabic, etc.
CertificationsCE Certified
Warranty3 years+lifetime technical support

Electromagnetic Compatibility (EMC) Test Setup

The device has undergone Radiated Electromagnetic Field Immunity testing according to IEC 61000-4-3:2020 standards. The test level was 30V/m with 80% AM, 1kHz Modulation, conducted at 25°C and 54% humidity.

Block diagram of the EMC test setup for the EMS Body Sculpt machine.
Figure 7.1: Block Diagram of EMC Test Setup.

8. Warranty & Support

Warranty Information

  • The main machine is guaranteed for one year from the date of purchase (excluding man-made damage, fragile parts, and expired warranty periods).
  • The warranty period for accessories is 3 months (excluding man-made damage).
  • Maintenance and updates are available, with appropriate fees charged for services outside the free warranty scope.
  • If the instrument requires repair and needs to be sent back, the buyer bears the return shipping cost within six months of purchase. After six months, the buyer bears all shipping costs.
  • Free warranty service is not provided for user failures caused by personal reasons, including:
    1. Faults caused by unauthorized disassembly and modification of the product.
    2. Faults caused by accidental fall.
    3. Failure caused by lack of reasonable maintenance.
    4. Failure to operate according to the correct instructions in this instruction manual.

Manufacturer

Guangzhou Xinwei Electronic Technology Co., Ltd.

For detailed instructions and further technical specifications, please refer to the User Manual (PDF).

9. User Tips

  • The machine is generally easy to use, with a clear interface.
  • Multiple handles allow for targeting different body parts effectively.
  • The combination of RF heating and electrical muscle stimulation can make workouts comfortable.
  • The device is quiet, making it suitable for home use.
  • Consistent usage is key for achieving ideal body shape results.
  • Results are progressive and natural, not instant fat loss.
  • The pelvic floor training function is particularly useful for postpartum recovery.

10. Frequently Asked Questions (FAQ)

Q: Do you have any results photos?
A: Yes, the product description includes images demonstrating before and after results from using the EMS Body Sculpt machine for body contouring and fat reduction.
Q: What is the actual maximum intensity of the electromagnetic field (Tesla or mT)? What is the working frequency? Can all 4 handles operate simultaneously at maximum intensity?
A: The technical specifications indicate a frequency range of 20-200 Hz adjustable for optimal muscle stimulation. The device is designed to induce supramaximal muscle contractions. For precise maximum intensity in Tesla or mT and simultaneous operation capabilities of all 4 handles at maximum intensity, please refer to the detailed technical specifications in the full User Manual (PDF) or contact customer support.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.