XikeStor SKS3200-5E2X

Contents

XikeStor SKS3200-5E2X Managed 2.5G Switch User Manual

Model: SKS3200-5E2X

1. Product Overview

The XikeStor SKS3200-5E2X is a high-performance Web Managed 2.5G switch featuring 5× 2.5GbE RJ45 ports and 2× 10G SFP+ uplink ports, delivering up to 35 Gbps switching capacity. Designed for pro-grade home networks, small offices, and NAS environments, it breaks through 1G bottlenecks to provide lightning-fast connectivity.

Key Features:

  • Ultra-Fast 2.5G & Dual 10G SFP+ Connectivity: 5× 2.5GbE RJ45 + 2× 10G SFP+ uplink ports.
  • Advanced Web Management: VLAN, LACP Link Aggregation (up to 10G bonded), QoS.
  • Silent Fanless Design & Durable Metal Housing: Premium full metal enclosure for superior passive cooling.
  • Versatile Installation: Supports both desktop and wall-mount placement.
  • Broad Compatibility: NAS (Synology, QNAP), Windows/macOS PCs, WiFi 6/7 APs, PS5, Xbox.
  • Plug-and-Play: In unmanaged mode; enable web management for advanced control.
XikeStor SKS3200-5E2X Managed 2.5G Switch front view with ports and branding.
Front view of the XikeStor SKS3200-5E2X switch, highlighting its 2.5GbE RJ45 and 10GbE SFP+ ports.
Diagram showing multi-device network connectivity with the XikeStor switch.
Multi-device network connectivity diagram, illustrating how the switch connects various devices like PCs, NAS, and printers.

2. Package Contents

Upon unpacking your XikeStor SKS3200-5E2X switch, please verify that all the following items are included:

ItemQuantity
SKS3200-5E2X Managed Switch1
Power Adapter (DC)1
Quick Installation Guide1
Rubber Feet (for desktop placement)4
Wall-Mount Kit (screws + brackets)1 set

For a visual guide on unpacking, please refer to the unboxing video below:

Unboxing video for the XikeStor SKS3200-5E2X Managed 2.5G Switch, showing all included components.

3. Hardware Overview & Specifications

Front Panel:

  • 5× 2.5GbE RJ45 ports (100M/1G/2.5G auto-sensing)
  • 2× 10G SFP+ uplink ports
  • LED indicators: Power, Link/Act for each port
  • RST button: Press to restore factory defaults

Rear Panel:

  • DC power input
  • Grounding nut for enhanced safety
Top-down view of the XikeStor SKS3200-5E2X switch, showing all ports and indicators.
Top-down view of the switch, detailing the port layout and LED indicators.

Product Specifications:

ParameterSpecification
ModelSKS3200-5E2X
TypeWeb Managed Layer 2+ Switch
RJ45 Ports5× 2.5G (100M/1G/2.5G auto-negotiation)
SFP+ Ports2x 10G SFP+ uplink ports
Switching Capacity35 Gbps
Shell MaterialFull metal enclosure (1.1mm thick)
CoolingFanless, passive heatsink design
ManagementWeb GUI + Mobile App
VLAN802.1Q VLAN, port-based VLAN
Link AggregationLACP (802.3ad) & static aggregation
QoS802.1p, port-based priority, bandwidth control
MAC Address Table8K entries
Power SupplyDC adapter (included)
InstallationDesktop (rubber feet) / Wall-mount
CertificationsCE, FCC, RoHS
Product parameters table for XikeStor SKS3200-5E2X switch.
Detailed product parameters and specifications.
Side view of the XikeStor SKS3200-5E2X switch, highlighting its anodized aluminum alloy body.
Anodized Aluminum Alloy Integrated Body, emphasizing strong protection, efficient heat dissipation, and anti-interference.

4. Setup: Hardware Installation

  1. Unpack and inspect: Remove the switch from the packaging. Verify all package contents are present.
  2. Choose placement: Place the switch on a flat desktop surface using the included rubber feet, or mount on a wall using the wall-mount kit.
  3. Connect power: Connect the DC power adapter to the switch and plug it into a power outlet. The power LED will illuminate.
  4. Connect network devices: Use Cat5e or better Ethernet cables to connect your devices (PCs, NAS, APs) to the 2.5GbE RJ45 ports. For higher-speed uplinks, insert SFP+ modules into the 10G SFP+ ports.
  5. Verify connectivity: Check the port LED indicators. A solid green light indicates a successful link at 2.5G/10G speed.

Tip: The switch works out-of-the-box in unmanaged mode. For advanced features (VLAN, LACP, QoS), enable Web Management (see Section 5).

Diagram showing port connections for DC 12V power, 2.5GbE RJ45, and 10GbE SFP+ ports.
Diagram illustrating the connection points for power, 2.5GbE RJ45 ports, and 10GbE SFP+ ports.

Lightning Protection Grounding Wire Installation:

For enhanced safety, especially in environments prone to electrical surges, install a lightning protection grounding wire:

Diagram showing how to install a lightning protection grounding wire on the switch.
Remove the default screw and replace it with the specialized surge protection screw included in the accessories. Tighten the screw after connecting the ground wire to effectively prevent surges and static electricity.

5. Operating: Web Management Configuration

The XikeStor SKS3200-5E2X switch features a web-based management interface for advanced configuration.

  1. Check Default IP: The switch default IP is 192.168.1.1 (or check the label on the device).
  2. Set Your PC IP: Configure your computer to a static IP in the same subnet, e.g., 192.168.1.100 (subnet mask 255.255.255.0).
  3. Access Web GUI: Open a web browser and enter the switch IP address.
  4. Login: Enter the default username and password (printed on the device label or quick guide).
  5. Configure: Navigate through the menu to configure VLAN, LACP, QoS, and other settings.
  6. Save & Reboot: After making changes, save the configuration. The switch will apply settings on reboot.

The web management interface also supports mobile APP access. Download the XikeStor management app to configure the switch conveniently from your phone.

Screenshot of the web management interface for the XikeStor switch.
Screenshot of the Web GUI, showing port settings and management options.

6. VLAN Configuration

VLAN (Virtual Local Area Network) allows you to segment your network into isolated broadcast domains, improving security and traffic efficiency.

Supported VLAN types:

  • 802.1Q VLAN (Tagged): VLAN tagging for trunk links
  • Port-based VLAN: Assign ports to specific VLANs

Common use cases:

  • Isolate guest WiFi traffic from the main corporate network
  • Separate IoT devices (cameras, smart home) from your primary data network
  • Create a dedicated VLAN for NAS storage traffic for optimized throughput

To configure VLANs, log into the Web GUI and navigate to VLAN Settings. Create VLAN groups and assign ports with the desired tagging mode.

8. QoS Configuration

Quality of Service (QoS) prioritizes network traffic to ensure critical applications receive the bandwidth they need.

QoS features:

  • 802.1p Priority: Classifies traffic based on 802.1p priority tags.
  • Port-based Priority: Assign high/low priority to specific ports.
  • Bandwidth Control: Set ingress/egress rate limits per port.

Use cases:

  • Prioritize VoIP and video conferencing traffic over file downloads.
  • Ensure low-latency for gaming consoles and streaming devices.
  • Limit bandwidth for guest networks to preserve bandwidth for critical devices.
  • Prioritize NAS backup traffic during business hours.

9. Maintenance

To ensure optimal performance and longevity of your XikeStor SKS3200-5E2X switch, consider the following maintenance guidelines:

  • Environment: The switch is designed for indoor use only. Keep it in a well-ventilated, dry environment.
  • Ventilation: Do not block the ventilation slots on the sides of the switch. Although it features a silent fanless design for passive cooling, proper airflow is crucial.
  • Temperature: The metal housing may become warm during full-load operation. This is normal and indicates effective passive heat dissipation. Ensure it's not placed in an enclosed space without adequate air circulation.
  • Cleaning: Periodically clean the exterior of the switch with a soft, dry cloth to prevent dust buildup, especially around ventilation areas.

10. Troubleshooting

If you encounter issues with your XikeStor SKS3200-5E2X switch, refer to the table below for common problems and their solutions.

ProblemSolution
Power LED not onCheck the power adapter connection. Try a different power outlet. Replace with the included adapter only.
Port LED not litCheck the Ethernet cable connection. Ensure the connected device is powered on. Try a different cable or port.
Cannot access Web GUIVerify PC is in the same subnet (192.168.1.x). Check the default IP on the device label. Press RST to reset if needed.
Speed only 1G on 2.5G portCheck cable quality (Cat5e+). Verify the connected device supports 2.5G. Try a different cable.
VLAN not workingVerify PVID is set correctly for untagged ports. Check that trunk ports include the correct tagged VLAN IDs.
LACP not formingEnsure both switch and peer device have matching LACP settings. Verify ports are in the same aggregation group.
Switch runs warmNormal operation. Ensure ventilation slots are not blocked. Keep in a well-ventilated area.

11. User Tips

To maximize your experience with the XikeStor SKS3200-5E2X switch, consider these important notes:

  • Cable Quality: Always use Cat5e or Cat6 Ethernet cables for reliable 2.5G operation. For 10G SFP+ ports, use compatible SFP+ modules or DAC cables to ensure optimal performance.
  • Network Path Consistency: To achieve full 2.5G/10G speeds, ensure all devices in your network path (cables, routers, Network Interface Cards) support the same speed.
  • Factory Reset: If the switch becomes unresponsive after configuration changes, press the RST button to restore factory defaults. This can often resolve unexpected behavior.
  • MAC Users & Link Speed: Be aware that certain USB network adapters on macOS may display lower link speeds in System Information due to driver limitations. Actual throughput may still reach expected speeds.

12. Frequently Asked Questions (FAQ)

Q: Is this switch plug-and-play?
A: Yes, the switch works out-of-the-box in unmanaged mode for basic connectivity. Advanced features like VLAN, LACP, and QoS require web management configuration.
Q: Can I manage the switch from my phone?
A: Yes, the web management interface supports mobile APP access. You can download the XikeStor management app to configure the switch conveniently from your phone.
Q: What is the default IP address for the web management interface?
A: The default IP address is 192.168.1.1. You can also find it on the device label or in the quick guide.
Q: Does this switch require a fan for cooling?
A: No, the SKS3200-5E2X features a silent fanless design with a full metal enclosure for passive heatsink cooling.

13. Warranty & Support

Warranty:

This XikeStor product is covered by a limited hardware warranty. Please contact your reseller or our support team for warranty terms.

Technical Support:

Our professional technical support team is ready to assist you with:

  • Installation and setup guidance
  • VLAN / LACP / QoS configuration
  • NAS compatibility and optimization
  • Network performance troubleshooting

Contact Information:

  • Website: www.seekswan.com
  • Brand: XikeStor by Anhui Xike Electronic Technology Co., Ltd.

We don't just sell products — we stand behind them. Your satisfaction is our priority.

For a complete and detailed user manual, please refer to the official PDF document available at: XikeStor SKS3200-5E2X User Manual (PDF)

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.