FDIK 2000W

Contents

FDIK 2000W 12V Diesel Air Parking Heater User Manual

Model: 2000W | Brand: FDIK

1. Introduction

The FDIK 2000W 12V Diesel Air Parking Heater is designed to provide a continuous flow of warmth, making it ideal for heating cabins, vehicles, or small spaces during cold weather. It operates by drawing in cold air, heating it through internal combustion, and then blowing out hot air. This manual provides essential information for the safe and efficient operation of your heater.

FDIK 2000W Diesel Air Parking Heater

Figure 1: FDIK 2000W Diesel Air Parking Heater

2. Safety Information

  • Ensure adequate ventilation when operating the heater to prevent carbon monoxide buildup.
  • Use only diesel fuel as specified. Do not use gasoline or other volatile fuels.
  • Keep flammable materials away from the heater's air inlet and outlet.
  • Ensure all electrical connections are secure and correctly polarized (Red for positive, Black for negative).
  • Do not operate the heater in enclosed, unventilated spaces where exhaust fumes can accumulate.
  • Regularly inspect the fuel lines and connections for leaks or damage.
  • Do not touch hot surfaces of the heater during or immediately after operation.

3. Product Overview

Key Features

  • FDIK control panel for intuitive operation.
  • High-quality oil pump for reliable fuel delivery.
  • High-quality ignition needle for consistent starting.
  • Includes a 220V adapter for versatile power options.
  • Durable metal case for strong impact resistance.
  • Portable design for easy movement and placement.
Fully Upgraded FDIK Heater Features

Figure 2: FDIK Heater Key Features

Control Panel

The heater features an LCD control panel for direct operation and monitoring. It includes buttons for temperature adjustment (Temp-, Temp+), and power control (On/Off). The display shows current temperature, operating mode (Power Mode, Fan Mode, Temperature Mode), and other indicators.

LCD Control Panel Details

Figure 3: LCD Control Panel

Heating Principle

Cold air enters through the air inlet, passes through the heated aluminum body, and is then heated. The hot air is blown out from the air outlet. The heater has a 2.3L fuel tank and consumes approximately 0.15-0.25L/H of fuel depending on temperature and power settings.

Heating Principle Demonstration

Figure 4: Heating Principle Diagram

Control Methods

The heater can be controlled via the wired LCD panel or wirelessly using the included remote control. The remote control has a maximum effective distance of 30 meters under barrier-free conditions.

Two Types of Control: LCD Panel and Remote

Figure 5: Control Options

Remote Control in Use

Figure 6: Remote Control

Internal Components

Key internal components include the Motor Assembly, Glow Plug, Combustion Chamber, and Oil Pump, all working together to ensure efficient heating.

Internal Components of the Heater

Figure 7: Internal Components

Exploded View of Heater Components

Figure 8: Exploded View with Labeled Parts (Heating zone, Overheat protection device, Flame retardant impeller, Control box, Air fan, Glow plug, Combustion chamber, Motor assembly)

Rapid Heating

The FDIK heater is designed for fast heating, capable of raising the temperature from 0°C to 100°C in approximately 10 minutes.

Heat Faster Graph

Figure 9: Heating Speed Comparison

Physical Features

Metal Case, Portable, Power Interface Details

Figure 10: Metal Case, Portability, and Power Interface

  • Metal Case: Durable and sturdy with strong impact resistance.
  • Portable: Easy to move and position.
  • Power Interface: Clearly marked with red for the positive pole and black for the negative pole.

4. Package Contents

The FDIK 2000W Diesel Air Parking Heater package typically includes the following items:

FDIK-2000W Product and Included Accessories

Figure 11: Package Contents

  • FDIK 2000W Diesel Air Parking Heater Unit
  • Remote Control
  • Power Adapter (with 220V plug)
  • Exhaust Pipe
  • Intake Pipe
  • Muffler
  • Air Duct
  • Clamps
  • Screws
  • User Manual (this document and a physical copy)

5. Setup

  1. Placement: Choose a stable, level surface for the heater, ensuring adequate clearance from walls and flammable materials.
  2. Connect Air Ducts: Attach the intake and exhaust pipes (25mm diameter) and the air outlet duct (60mm diameter) securely using the provided clamps. Ensure proper sealing to prevent leaks.
  3. Fuel Connection: Fill the 2.3L fuel tank with clean diesel fuel. Connect the fuel line from the tank to the oil pump and then to the heater unit. Ensure all connections are tight to prevent leaks.
  4. Electrical Connection: Connect the power cables to a 12V power source. The red cable is for the positive pole, and the black cable is for the negative pole. Ensure a secure and correct connection.
  5. Initial Oil Pump Start (Priming): After connecting the fuel, it is crucial to prime the oil pump to ensure the fuel line is full and free of air bubbles. In the off state, press and hold the Power On/Off button for 5 seconds until the screen displays "Po". Release the button. The ignition plug will preheat for 1 minute before the oil pump starts. Once the oil line is full, the device will automatically ignite and enter normal combustion. If the oil line is not filled after one attempt and the fan is still running, the screen will display "Po" flashing. Press the Power On/Off button again to start a second oil pumping attempt.

6. Operating Instructions

6.1. C24 Three-Key Digital Controller Operations

Quick Remote Matching

When the device is off, press and hold the up and down buttons simultaneously on the control panel. The screen will display a 10-second countdown, entering remote control matching mode. Within 10 seconds, press any button on the remote to successfully pair it.

Operations in Power-On State

  1. Power On/Off: Press the Power On/Off button once to turn the device on. Press it again to turn it off.
  2. Air Conditioning Mode (Temperature Mode): While the device is on, press and hold the Power On/Off button for 3 seconds to switch to Temperature Mode, with a range from 10°C to 35°C. Use the Gear Increase and Decrease buttons to set the desired temperature. The set temperature must be higher than the current ambient temperature. When the device reaches the set temperature, it will reduce to a lower combustion speed. If the temperature is not reached, the device will increase the combustion speed to meet the set temperature.
  3. Power Mode: In Air Conditioning Mode, press and hold the Power On/Off button for 3 seconds to switch back to Power Mode. Adjust the power level using the Gear Increase and Decrease buttons, with levels P1 to P5 (5 levels).

Following Functions in Power-Off State

  1. Normal Power-On: In the off state, press and hold the Power On/Off button for 5 seconds. The screen will display "ON". Release the button to power on normally.
  2. Automatic Oil Pump Start: (See Setup section for detailed instructions on priming).
  3. Ventilation Function: Press and hold the Power On/Off button until the screen displays "Fn". Release the button; it will show "F1" to "F5" which can be adjusted to provide ventilation for the cabin.
  4. Remote Control Matching: Press and hold the Power On/Off button until the screen shows "R1". Release the button, and within 10 seconds, press any button on the remote to successfully pair it.
  5. Manual Oil Pumping via Remote: Long press the 5th display icon on the screen of the power key, "rp". Release the button, and the screen will display "20", indicating the function will turn off after 20 minutes. Press the remote's power button to start oil pumping; press the remote's power button again to stop oil pumping. Note: 1. This function does not support ignition. Monitor the oil line and stop pumping once it is full. 2. After using this function, the paired remote needs to be re-matched.
  6. Language Selection and Do Not Disturb Mode: Long press the 6th display icon on the screen of the power switch, "LA". Release the button, then use the Gear Increase and Decrease buttons to select the language. The screen will display options such as "CH" (Chinese) or "BP" (Silent). Select the desired language by adjusting the knob to set it successfully.
  7. Emergency Start: If the device switch is damaged, first disconnect three switch wires (black, blue, and red). Short the black and blue wires together at a regular frequency 7 times (1-2-3-4-5-6), then do not release on the 7th time but hold for 1 minute. If the mainboard is not damaged, the device will start normally.

6.2. Setting Temperature Mode and Oil Pump Flow (Advanced)

This procedure is for advanced configuration and calibration. Disconnect the power switch wire. Then, press and hold the power switch button without releasing it. Next, reconnect the power switch wire. The screen will display "CF" followed by a number. Release the button. Multiply the displayed number by 5 and add 1. For example, if the number displayed is 2, then 2*5 + 1 equals 11. Press the up button to select the last digit (in this case, 1), then press the power switch button to enter the settings function.

  • The first screen that appears is: Power Voltage, which sequentially shows 24V Power, -12V Power, and 0A Automatic Voltage. Press the power switch button to confirm in the 0A state. The voltage will automatically match.
  • Next, the screen will show 22, which indicates a 22 oil pump. Press the up button to display 28, which indicates a 28 oil pump. Press the up button again to show 0A, which is for automatic oil pump matching. Select the desired oil pump flow rate and press the power switch button to confirm the oil pump setting.
  • Once the oil pump is set, the screen will display "15" to indicate the temperature mode shutdown function. "t----" turns off the temperature mode shutdown function. If you want to enable it, in the "t5" state, press the power switch button to confirm.
  • After all settings are completed, the screen will display "Su" after 5 seconds and then shut down, indicating that all settings are completed.

6.3. Clear Current Remote Configuration

Disconnect the switch wires, press and hold the Power On/Off button, and reconnect the switch wires. The screen will display "CF". Release the button, then press the Power On/Off button to clear the configuration.

7. Maintenance

  • Regular Cleaning: Keep the heater's exterior clean. Ensure the air inlet and outlet are free from dust and debris.
  • Duct Inspection: Periodically check all air ducts for obstructions or damage. A clear air path is crucial for efficient operation and to prevent overheating.
  • Fuel System Check: Inspect fuel lines and connections for any signs of leaks or blockages. Ensure the fuel quality is good to prevent issues with the oil pump and ignition.
  • Electrical Connections: Verify that all electrical connections remain secure and free from corrosion.
  • Ignition Plug: If experiencing starting issues, the ignition plug may need inspection or replacement. Refer to the troubleshooting section for error codes.

8. Troubleshooting (FDIK C3 Fault Code Manual)

If your heater encounters an issue, the control panel may display an error code. Refer to the table below for common fault codes and their solutions.

Error CodeProblemSolution
0Panel failureReplace the panel
1Ignition failure failed
  • Whether the fuel tank is short of oil, fuel exhausted.
  • Whether the oil pump is stuck, abnormal.
  • Whether the oil circuit is correct, bubbles inside and the oil supply is not continuous.
  • Poor power supply, oil quality problem.
2Flame out
  • Oil path leaks or there are bubbles inside, the oil supply is not continuous.
  • The fuel tank is short of oil, the oil pump abnormal, oil quality problem.
3The power supply voltage is incorrect, Under-voltage or over-voltage
  • The power cord is incorrectly connected, please make sure that the power voltage is consistent with the voltage marked on the machine.
  • The connector is not securely inserted, and the power cord is installed with poor contact.
  • Poor touch inside the fuse box.
  • The panel's configuration does not match the vehicle's voltage.
  • Substandard electrical cables connected with extra ones.
  • The power converter cannot supply enough current.
  • The output voltage of converter is unstable.
6Intake air over-temperature
  • The room temperature is too high.
  • Cycle of the machine's air outlet and inlet.
  • Installation space is too narrow.
7Oil pump problem
  • The oil pump is not connected properly, the connection line is open or short-circuited.
  • The 5-pin socket panel is not plugged in properly.
  • There is a disconnection in the oil pump circuit, the oil pump fault.
8Fan (motor) Problem
  • Fan blades of the motor are stuck.
  • Incorrect speed check (the motor repeats 3 times to report fault).
  • The internal fault of the motor.
  • The motor socket is not plugged in properly.
9Ignition shorted plug
  • The ignition pin is short-circuited or the connection wire is reversed.
  • Insulation damage at the end of the ignition plug causes a short circuit.
  • Ignition plug leakage.
10Overheat
  • Obstacles to the circulation of the machine, obstructed air duct.
  • Installation space is too narrow.
  • Wrongly connected to an oil pump with a large flow rate.
  • Oil pump check valve leakage.
  • The sensor is damaged.
11Overheating sensor failureReplace the overheat sensor
12Ignition plug open circuit
  • Poor contact of ignition plug connector.
  • The ignition plug is burned out and replaced.

9. Specifications

AttributeValue
Brand NameFDIK
Item TypeHeating & Fans
Power (W)2000W
Voltage12V
Fuel TypeDiesel
Switch TypeLCD Switch
Special FeaturesAir heating
OriginMainland China
High-concerned chemicalNone
Product Length30 cm
Product Width20 cm
Product Height18 cm
Product Weight6.0 kg
Fuel Tank Capacity2.3 L
Fuel Consumption0.15-0.25 L/H
Air Outlet Duct Diameter60 mm
Intake/Exhaust Duct Diameter25 mm
Remote Control DistanceUp to 30 meters (barrier-free)

10. User Tips

  • When installing, ensure the air outlet duct has a diameter of 60mm, and the intake and exhaust ducts are 25mm for proper fitment and operation.
  • The heater is primarily available with a white housing, as depicted in product images.

11. Frequently Asked Questions (FAQ)

Q: Is the heater only available in red?
A: No, the heater has a white housing, as shown in the product pictures.
Q: What are the dimensions of the outlet and intake/exhaust pipes?
A: The diameter of the air outlet duct is 60mm, and the dimensions of the intake and exhaust ducts are 25mm.

12. Warranty and Support

For detailed warranty information, service, and additional support, please refer to the comprehensive user manual provided in PDF format. This document contains specific terms and conditions regarding product warranty and contact information for technical assistance.

You can access the PDF user manual here: FDIK 2000W Diesel Heater User Manual (PDF)

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.