Refoss EM06P

Contents

Refoss Smart Energy Monitor EM06P User Manual

Refoss EM06P Smart Energy Monitor with CT clamps and app display

Model: EM06P

1. Important Safety Information

WARNING!

The Refoss EM06P needs to be installed in the electrical panel of a home and operates in an environment that may pose a risk of injury or electric shock. Refoss recommends that the unit be installed by a licensed professional electrician or other qualified professional in accordance with the electrical codes for the area in which it is to be used.

Incorrect installation and incorrect use of the equipment may result in electrical safety injuries. Refoss shall not be liable to any person or third party for direct or indirect injuries and damages resulting from failure to comply with the following safety guidelines.

Safety Guidelines:

  • Always wear Personal Protective Equipment (PPE) when installing the Refoss EM06P.
  • Only use the Refoss EM06P as specified in this installation guide and avoid any other usage.
  • If you suspect any damage to the Refoss EM06P equipment, do not attempt to use it.
  • Avoid installing the Refoss EM06P in humid environments and keep it away from direct sunlight.
  • Make sure the Refoss EM06P is not connected to the power supply during any manual processes, such as installation or removal.
  • The current transformer (CT) is rated at 120 A and saturated at 150 A. The current to be detected will be limited to a maximum of 150 A.

2. Package Contents

Please check the package for the following items:

  • Smart Energy Monitor (x1)
  • Current Transformers (CT) (x3 or x6, depending on variant)
  • Power Harness (x1)
  • Quick Installation Guide (x1)

For a visual representation of the package contents, please refer to the Quick Installation Guide PDF.

3. Setup and Installation

3.1. Download the Meross App

To set up your Refoss EM06P, you will need the Meross app. Scan the QR code provided in your Quick Installation Guide or search for 'Meross' in your device's app store (App Store for iOS, Google Play for Android) to download and register an account.

3.2. Preparation for Installation

Before starting the installation process, it is essential to turn off the main circuit breaker in your electrical panel. This will ensure that the panel where you plan to install the equipment is completely de-energized and safe to work with. Additionally, make sure to allocate enough space in the electrical panel for the equipment. This will allow for easy mounting on DIN rails.

3.3. Plug in Power Harness

Insert the power harness into the designated side of the monitor, ensuring a secure and proper connection. It should snap into place. The power harness is designed to support the capture of single-phase and three-phase voltages while providing power to the EM06P device.

Caution!

When connecting the current transformers (CT) later, ensure that each current transformer (CT) is correctly aligned with the corresponding voltage harness to ensure accurate data collection.

Power Harness Wire Correspondence
Wire ColorCorresponds to
Red LineA1, A2
Green LineB1, B2
Black LineC1, C2, Power
White LineNeutral
  • - The voltage captured by the red line corresponds to the current in the A1, A2 lines.
  • - The voltage collected on the green line corresponds to the current in the B1, B2 lines.
  • - The black line collects the voltage corresponding to the current in lines C1, C2 and supplies power to the EM06P.

3.4. Wire Connection

The Refoss EM06P supports single-phase, two-phase, and three-phase circuits. For detailed wiring diagrams, please consult the official user manual PDF: Refoss EM06P User Manual (PDF).

a. Single-phase circuit

In a single-phase circuit, all 6 current transformers (CTs) have the same voltage, allowing you to monitor any 6 lines in your electrical panel.

b. Two-phase circuit

When monitoring a two-phase circuit, it is crucial to ensure the correct correspondence between the voltage lines and the current ports listed in the table above. Failing to establish the correct matching relationship may result in inaccurate consumption metering results.

c. Three-phase circuit

When monitoring a three-phase circuit, it is crucial to ensure the correct correspondence between the voltage lines and the current ports listed in the table above. Failing to establish the correct matching relationship may result in inaccurate consumption metering results.

3.5. Installation of CT

Clip your current transformer (CT) to the corresponding line according to the correspondence between the voltage line and the current port listed in the power harness table.

3.6. Set up the Device (App Configuration)

  1. Launch the Meross app and log in to your account, or if you are a new user, tap Sign up to create a new account.
  2. Tap the "+" icon to select the type "Smart Energy Monitor", then follow the setup wizard to finish configuration.

NOTE:

This smart device needs to be set up via Bluetooth. Please make sure the Meross app is granted access to required system permissions and the Bluetooth of your smartphone has been enabled.

4. Operating the Device

4.1. LED Rules

  • Green light blinking:

    • The device is in pairing mode. To connect, ensure Bluetooth is turned on and use the Meross app to discover your device.
    • Firmware upgrade is currently in progress.
  • Red light continuously on:

    • The device is connected to the router, but the router does not currently have an available network connection.
  • Red light blinking:

    • Your device is disconnected from the router. Please check the router connection and ensure it is properly connected.

4.2. Button Function

Press and hold the button for 10 seconds and then release it. The device will reset. The device will enter pairing mode after completing the reset, and the green light will blink.

4.3. Home Assistant Integration

The Refoss EM06P supports integration into the Home Assistant platform. For the full setup guide and documentation, please refer to the official Meross-Tech GitHub repository: https://github.com/Meross-Tech/meross_rpc.

Home Assistant version required: 2025.2.5 or above.

Home Assistant and Web Portal integration

Home Assistant integration for advanced energy management.

Official product video demonstrating features and integration.

5. Maintenance

The Refoss EM06P is designed for long-term, maintenance-free operation once installed correctly. To ensure optimal performance and longevity:

  • Keep the device and its surrounding area in the electrical panel clean and free from dust and debris.
  • Ensure the electrical panel remains dry and free from moisture.
  • Do not attempt to open or repair the device yourself. Refer to qualified professionals for any service needs.

6. Troubleshooting (FAQ)

Why can't the Meross app find my device after I installed EM06P?

  • Check that the main circuit breaker is on.
  • Check that the circuit breaker supplying power to the EM06P is turned on.
  • Check if the device LED is blinking slowly in green (once every 0.5s). If not, press and hold the button for 10s to reset and try again.
  • Make sure that your phone is authorized for the Meross app and has Bluetooth turned on.

Why is the Meross app unable to obtain real-time current and consumption data from the EM06P?

  • Check that the current transformer is securely plugged into the monitor.
  • Check that the cable with the transformer clipped to it is not working with a load device.

Why is the reading of the sales volume in the Meross app showing as a negative number?

It may be due to the CT sensor's direction being reversed. Reversing the direction of the CT sensor should resolve the issue. The correct wiring direction is when the current direction matches the direction indicated on the CT sensor (K->L). In the correct wiring configuration, a positive value indicates power consumption by appliances, while a negative value indicates generation (such as monitoring home power generation devices, etc.).

7. Technical Specifications

SpecificationDetail
Power Supply100-240V~
CT RangeMaximum 120A for single line
Dimensions (W x D x H)7.3 x 5.2 x 2.45 cm (Monitor size)
CT Line Length90 cm
Operating Frequency2400MHz~2483.5MHz/20dBm
Wireless CommunicationWiFi
Control Channels6 channels

Voltage-current Correspondence:

  • Red -> A1, A2
  • Green -> B1, B2
  • Black -> C1, C2, Power

8. User Tips

Based on general feedback for smart energy monitors, users often find the following tips helpful:

  • Verify CT Direction: Always double-check the direction of your CT clamps. Incorrect orientation is a common cause for negative readings or inaccurate data.
  • Network Stability: Ensure your Wi-Fi network is stable and within range of the EM06P for consistent data reporting and remote access.
  • Data Interpretation: Take time to understand the app's charts and data exports. This will help you identify energy consumption patterns and potential areas for savings.
  • Home Assistant Integration: For advanced users, leveraging Home Assistant can unlock powerful automation scenarios, such as optimizing appliance usage based on solar generation.

9. Warranty and Support

Warranty

Refoss products are covered by a 24-month limited warranty from the date of its original purchase. If any problems occur, please contact Refoss support.

Need Help?

If you have any questions during hardware installation or setup process, or require technical support, please contact us at: https://www.meross.com/support.

Disclaimer

  1. The function of this smart device is tested under typical circumstances described in our specifications. Refoss does NOT guarantee that the smart device shall perform exactly the same as described under all circumstances.
  2. Refoss's total liability is limited to what is expressly covered in its Privacy Policy.
  3. Damages arising from ignorance of the SAFETY INFORMATION shall not be covered by Refoss aftersales service, nor does Refoss take any legal responsibility therefrom.

Customers acknowledge understanding of these articles clearly by reading this manual.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.