PowMr POW-HVM12KP

Contents

PowMr 12000W 48V Hybrid Solar Inverter User Manual

Model: POW-HVM12KP

1. Introduction

This manual provides comprehensive instructions for the assembly, installation, operation, and troubleshooting of the PowMr 12000W 48V Hybrid Solar Inverter. Please read this manual carefully before installation and operation, and keep it for future reference.

The PowMr POW-HVM12KP is a multi-function inverter/charger that combines the capabilities of an inverter, solar charger, and battery charger to provide uninterrupted power support. It features a comprehensive LCD display and user-configurable button operations for settings such as battery charging current, AC/solar charger priority, and acceptable input voltage ranges for various applications.

This inverter is designed to power a wide range of home appliances, including motor-type appliances like tube lights, fans, refrigerators, and air conditioners.

Video: Unboxing and overview of the PowMr Hybrid Solar Inverter, showing included accessories and key features.

1.1 Key Features

  • Pure sine wave output.
  • Configurable input voltage range for home appliances and personal computers via LCD setting.
  • Configurable battery charging current based on applications via LCD setting.
  • Configurable AC/Solar Charger priority via LCD setting.
  • Compatible with mains voltage or generator power.
  • Auto restart while AC is recovering.
  • Overload, over temperature, and short circuit protection.
  • Smart battery charger design for optimized battery performance.
  • Cold start function.
  • Supports connection to lithium battery.
  • Built-in MPPT solar controller.
  • Maximum of 9 parallel units for expanded capacity.

2. Safety Instructions

WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.

  1. Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
  2. CAUTION - To reduce the risk of injury, charge only deep-cycle lead-acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
  3. Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
  4. To reduce the risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
  5. CAUTION - Only qualified personnel can install this device with a battery.
  6. NEVER charge a frozen battery.
  7. For optimum operation of this inverter/charger, please follow the required specifications to select the appropriate cable size. It's very important to correctly operate this inverter/charger.
  8. Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool, causing sparks or short circuits in batteries or other electrical parts, which could lead to an explosion.
  9. Please strictly follow the installation procedure when disconnecting AC or DC terminals. Refer to the Installation section of this manual for details.
  10. Two 150A fuses are provided as over-current protection for the battery supply.
  11. GROUNDING INSTRUCTIONS - This inverter/charger should be connected to a permanent grounded wiring system. Be sure to comply with local requirements and regulations for installing this inverter.
  12. NEVER cause AC output and DC input to short circuit. Do NOT connect to the mains when DC input short circuits.
  13. Warning!! Only qualified service persons are able to service this device. If errors still persist after following the troubleshooting table, please send this inverter/charger back to a local dealer or service center for maintenance.

3. Product Overview

The PowMr Hybrid Solar Inverter is an all-in-one solution for solar energy management. Below are diagrams illustrating its components and system architecture.

3.1 Basic System Architecture

The inverter/charger integrates solar charging, AC/DC load supply, grid charging, bypass, and battery discharge functions. It is compatible with 48V lead-acid or lithium batteries and features dual MPPTs for two independent PV arrays.

Hybrid Power System Diagram

Figure 1: Hybrid Power System Diagram. Shows solar panels, generator/utility, battery bank, and home appliances connected to the inverter.

48V Battery Ready Diagram

Figure 2: 48V Battery Ready. Illustrates compatibility with various 48V battery types (LiFePO4, Lithium, AGM, GEL, Lead-Acid) and smart charge control via BMS communication.

Dual PV Input Diagram

Figure 3: Dual PV Input. Shows two independent PV inputs (PV1 and PV2) with MPPT technology, maximizing solar energy harvest. Each PV input supports up to 6500W.

Dual AC Output Diagram

Figure 4: Dual AC Output. Illustrates smart load management with AC OUT1 for essential loads (lights, router, TV, refrigerator, security system) and AC OUT2 for high power loads (air conditioner, water pump, washing machine, microwave oven, electric heater).

Complete Home Energy Solution Diagram

Figure 5: Complete Home Energy Solution. Depicts the inverter's role in intelligent energy management, providing energy independence, backup power, reduced electricity bills, and smart monitoring via LCD and mobile app.

3.2 LCD Screen and Buttons

The front panel features an LCD screen and four function keys for operation and display of system status and power information.

Inverter Front Panel with LCD

Figure 6: Inverter Front Panel. Shows the LCD display and control buttons.

Function Keys:

  • **ESC**: To exit setting mode.
  • **UP**: To go to the previous selection.
  • **DOWN**: To go to the next selection.
  • **ENTER**: To confirm the selection in setting mode or enter setting mode.

LED Indicators:

  • **AC/INV (Green)**: Solid On for utility power, Flashing for battery/PV power.
  • **CHG (Yellow)**: Solid On for fully charged battery, Flashing for charging battery.
  • **FAULT (Red)**: Solid On for fault, Flashing for warning.

3.3 Back Panel Connections

The back panel provides all necessary connection ports for the inverter system.

Inverter Back Panel

Figure 7: Inverter Back Panel. Displays the various input/output terminals and communication ports.

  1. AC Input
  2. RS232 Communication Port
  3. Main Output
  4. BMS/RS485 Communication Port
  5. Second Output
  6. Dry Contact
  7. Power ON/OFF Switch
  8. PV Input
  9. Parallel Connection
  10. Battery Port
  11. Fan
  12. Input Breaker
  13. Battery Terminal Positive (+)
  14. Battery Terminal Negative (-)

4. Installation

4.1 Unpacking and Inspection

Before installation, inspect the unit for any damage. The package should contain:

  • Inverter unit x 1
  • User manual x 1
  • Parallel communication cable x 1
  • Current sharing wires x 1
  • Expansion screws (M6*80mm) x 3
  • Battery fuses x 2
  • Male MC4 connectors & Female MC4 connectors x 2 pairs

4.2 Preparation

Before connecting any wires, remove the bottom cover by unscrewing the five retaining screws.

4.3 Mounting the Unit

Consider the following points when selecting a mounting location:

  • Do not mount on flammable materials.
  • Mount on a solid surface.
  • Install at eye level for easy LCD display reading.
  • Allow approximately 20 cm clearance to the sides and 50 cm above and below for proper air circulation and heat dissipation.
  • Ambient temperature should be between 20°C and 35°C for optimal operation.
  • Mount vertically on the wall.
  • Ensure sufficient space for wiring and heat dissipation as shown in the diagram.

SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.

Inverter Dimensions and Airflow

Figure 8: Product Overview. Shows dimensions (620mm height, 420mm width, 140mm depth) and recommended airflow direction for cooling.

Secure the unit using four screws. Use M6*80mm expansion bolts for the top suspension and M4 or M5 screws for the three lower holes. Do not use the mounting hole located at the lower left corner to avoid damaging internal components.

4.4 Battery Connection

CAUTION:

  • Install a separate DC over-current protector or disconnect device between the battery and inverter.

WARNING:

  • All wiring must be performed by qualified personnel.
  • Use appropriate cable sizes for battery connection to ensure system safety and efficient operation. Refer to the table below for recommended sizes.
  • Shock Hazard: Installation must be performed with care due to high battery voltage in series.
  • Before making the final DC connection, ensure positive (+) is connected to positive (+) and negative (-) to negative (-).

Recommended Battery Cable and Terminal Size:

Model Typical Amperage Battery Capacity Wire Size Cable (mm²) Ring Terminal Dimensions Torque Value
D(mm) L(mm)
POW-HVM12KP 228A 250Ah 1*3/0AWG 85 8.4 54 5 Nm

Battery Connection Steps:

  1. Assemble battery ring terminals based on recommended cable and terminal size.
  2. Connect all battery banks to the 48VDC battery system as shown in the diagram.
  3. Insert battery wires flatly into the inverter's battery connectors. Ensure bolts are tightened to 2 Nm in a clockwise direction. Verify correct polarity at both the battery and inverter/charger, and that conductors are tightly screwed into the battery terminals.
Battery Connection Diagram

Figure 9: Battery Connection. Shows the positive (Red) and negative (Black) battery cable connections to the inverter.

4.5 AC Input/Output Connection

CAUTION:

  • Install a separate AC breaker between the inverter and the AC input power source. The recommended breaker size is 63A for a 48V system.
  • Do NOT mis-connect input and output connectors.

WARNING:

  • All wiring must be performed by qualified personnel.
  • Use appropriate cable sizes for AC input connection. Refer to the table below for recommended sizes.
  • Ensure the AC power source is disconnected before hardwiring to the unit.

Suggested Cable Requirement for AC Wires:

Model Gauge Torque Value
POW-HVM12KP 8 AWG 1.4~1.6 Nm

AC Input/Output Connection Steps:

  1. Before making AC input/output connections, ensure the DC protector or disconnector is open.
  2. Remove 10mm of insulation sleeve for six conductors. Shorten phase L and N by 3mm.
  3. Insert AC input wires according to polarities (Ground: yellow-green; Line: brown or black; Neutral: blue) and tighten terminal screws. Connect the PE protective conductor first.
  4. Insert AC main output wires according to polarities and tighten terminal screws. Connect the PE protective conductor first.
  5. Insert AC second output wires according to polarities and tighten terminal screws. Connect the PE protective conductor first.

CAUTION:

Appliances like air conditioners require 2-3 minutes to restart. If power fluctuates rapidly, it can damage connected appliances. Check if your air conditioner has a time-delay function. Otherwise, the inverter may trigger an overload fault to protect the appliance, but internal damage can still occur.

4.6 PV Connection

CAUTION:

  • Install a separate DC circuit breaker between the inverter and PV modules.

WARNING:

  • All wiring must be performed by qualified personnel.
  • Use appropriate cable sizes for PV module connection.

Suggested Cable Requirement for PV Wires:

Model Typical Amperage Gauge Torque Value
POW-HVM12KP 30A 12 AWG 1.4~1.6 Nm

PV Module Selection:

  • The open circuit voltage (Voc) of PV modules must not exceed the inverter's maximum PV array open circuit voltage.
  • The maximum supply voltage of PV modules should be close to the optimal PV access voltage range for best performance. Connect multiple PV modules in series if a single module cannot meet this requirement.

PV Module Wire Connection Steps:

  1. Check the input voltage of PV array modules. This system uses two strings of PV array. Ensure the maximum current load of each PV input connector is 27A/27A.
  2. Disconnect the circuit breaker and switch off the DC switch.
  3. Assemble provided MC4 connectors with PV modules. Strip 10mm of cable insulation, insert into terminals, crimp, and then insert into connector housings. Use spanners to tighten for a secure, waterproof connection.
  4. Check correct polarity of wires from PV modules and PV input connectors. Connect positive (+) to positive (+) and negative (-) to negative (-).

4.7 Final Assembly

After connecting all wirings, reinstall the bottom cover by screwing in the five retaining screws.

5. Operation

5.1 Power ON/OFF

Steps to Start Up:

  1. Close the battery circuit breaker.
  2. Press the On/Off switch (located on the bottom of the case) to turn on the unit. Wait until the inverter starts up and enters normal operation (inverting).
  3. Close the PV and AC input circuit breakers.
  4. Finally, close the AC output circuit breaker.

Shutdown Steps:

To shut down the system, turn off the circuit breakers in the reverse order of startup. When the system is in battery mode or AC mode output, press the switch again to turn off the system.

5.2 LCD Setting

To enter setting mode, press and hold the ENTER button for 3 seconds. Use the "UP" or "DOWN" buttons to select settings, and "ENTER" to confirm or "ESC" to exit. Key settings include:

  • Output source priority selection (Program 01): Configure whether solar energy, utility, or battery is prioritized for loads.
  • Maximum charging current (Program 02): Set the total charging current for solar and utility chargers (10A to max, 10A increment).
  • AC input voltage range (Program 03): Select between Appliance (90-280VAC) or UPS (170-280VAC) mode.
  • AC output mode (Program 04): Configure for single or three-phase parallel operation.
  • Battery type (Program 05): Select AGM, Flooded, User-Defined, LIA-protocol, Pylontech, Techfine, Growatt, Felicity, or LIB-protocol compatible batteries.
  • Output frequency (Program 09): Set to 50Hz or 60Hz.
  • Output voltage (Program 10): Set to 220V, 230V, or 240V.
  • Battery equalization (Program 30): Enable or disable battery equalization.
  • BMS Function Switch (Program 37): Enable or disable BMS communication.
  • Solar energy feed to grid configuration (Program 44): Enable or disable feeding excess solar energy to the grid.

For a complete list of LCD settings and their descriptions, please refer to the detailed tables in the full user manual (PDF).

5.3 Operating Mode Description

The inverter operates in various modes depending on power availability and configuration. These modes are indicated on the LCD display.

  • Standby Mode: Inverter is not yet fully on but can charge the battery without AC output.
  • Line Mode: Utility power is available and provides power to the load, charges the battery, or both.
  • Battery Mode: Output power is supplied from the battery or PV.
  • Only PV Mode: Output power is supplied solely from PV.

Detailed diagrams for each operating mode are available in the full user manual (PDF).

5.4 Communication and Dry Contact Signal

The inverter supports BMS/RS485 communication for external battery management systems and features a dry contact signal (3A/250VAC) on the rear panel. This dry contact can be used to trigger external devices when the battery voltage reaches a warning level.

The RS232 communication port allows for data exchange with external systems. The BMS/RS485 communication interface is externally connected as shown in the back panel diagram.

Dry Contact Signal Conditions:

Unit Status Condition Dry Contact Port
NC & C NO & C
Power Off Unit is off and no output is powered. Close Open
Power On Normal mode: Battery voltage < Low DC warning voltage Open Close
Normal mode: Battery voltage > Float charging voltage Close Open
Solar first mode: Battery voltage < Solar to AC voltage Open Close

5.5 Battery Equalization Description

The equalization function helps to reverse the buildup of negative chemical effects like stratification and remove sulfate crystals from battery plates, which can reduce battery capacity. It is recommended to equalize batteries periodically.

How to Apply Equalization:

  1. Enable battery equalization in LCD setting program 30.
  2. Set the equalization interval in program 35, or activate equalization immediately in program 36.

The inverter will enter the Equalize stage when the set interval is reached or immediately activated. During this stage, the controller charges the battery until it reaches the equalization voltage, then maintains this voltage until the set equalization time expires.

6. Parallel Function

The PowMr 12000W 48V Hybrid Solar Inverter supports parallel operation for increased power output, up to a maximum of 9 units. This allows for a total output of up to 99kW.

6.1 Mounting the Unit for Parallel Operation

When installing multiple units, ensure proper spacing for air circulation. Allow approximately 20 cm to the sides and 50 cm above and below each unit. All units must be installed at the same level.

6.2 Wiring Connection for Parallel Operation

WARNING:

  • Do not connect the current sharing cable between inverters in different phases, as this may damage the inverters.
  • Ensure all inverters share the same battery bank. Otherwise, inverters will enter fault mode.
  • The length of all battery cables must be identical to prevent voltage differences between inverters and the battery, which can cause parallel inverters to malfunction.

CAUTION:

  • Install breakers at both the battery and AC input sides to ensure safe disconnection and over-current protection.

For detailed wiring diagrams for single-phase and three-phase parallel configurations (2 to 9 units), please refer to the full user manual (PDF).

6.3 PV Connection for Parallel Operation

NOTE:

  • Each inverter must be connected to an independent photovoltaic array. Multiple inverters must not share the same photovoltaic array, as this can cause irreversible damage.
  • Each inverter needs to be connected to two photovoltaic input terminals, with each terminal connected to a separate photovoltaic array.

Refer to the schematic diagrams in the full user manual (PDF) for detailed photovoltaic array wiring guidelines in parallel operation mode.

6.4 Commissioning Parallel Units

Parallel in Single Phase:

  1. Check requirements: Verify correct wire connections. Ensure all breakers in the Line wires of the load side are open, and Neutral wires of each unit are connected together.
  2. Set "PAL" mode: Turn on each unit and set "PAL" in LCD setting program 4. Then, shut down all units. (Note: It's necessary to turn off the switch when setting the LCD program; otherwise, the setting cannot be programmed.)
  3. Turn on units: Turn on each unit. Master and slave units are randomly defined.

7. Troubleshooting

This section provides guidance for common issues. For persistent errors, contact customer service.

7.1 Faults Descriptions

When a fault occurs, the red LED light will be continuously on, and the LCD will display a fault code. Some common fault codes include:

  • **Fault Code 01**: Fan is locked when inverter is off.
  • **Fault Code 02**: Over temperature or NTC is not connected well.
  • **Fault Code 03**: Battery voltage is too high.
  • **Fault Code 04**: Battery voltage is too low.
  • **Fault Code 05**: Output short circuited or over temperature detected.
  • **Fault Code 06**: Output voltage is too high.
  • **Fault Code 07**: Overload time out.
  • **Fault Code 08**: Bus voltage is too high.
  • **Fault Code 09**: Bus soft start failed.
  • **Fault Code 51**: Over currents or surge.
  • **Fault Code 52**: Bus voltage is too low.
  • **Fault Code 53**: Inverter soft start failed.
  • **Fault Code 55**: Over DC voltage in AC output.
  • **Fault Code 57**: Current sensor failed.
  • **Fault Code 58**: Output voltage is too low.
  • **Fault Code 59**: PV voltage is over limitation.
  • **Fault Code 60**: Power feedback protection.
  • **Fault Code 71**: Firmware version inconsistent.
  • **Fault Code 72**: Current sharing fault.
  • **Fault Code 80**: CAN fault.
  • **Fault Code 81**: Host loss.
  • **Fault Code 82**: Synchronization loss.
  • **Fault Code 83**: Battery voltage detected different.
  • **Fault Code 84**: AC input voltage and frequency detected different.
  • **Fault Code 85**: AC output current unbalance.
  • **Fault Code 86**: AC output mode setting is different.

For detailed troubleshooting steps for each fault code, refer to the full user manual (PDF).

7.2 Warning Descriptions

When a warning occurs, the red LED will flash, and the LCD will display an alarm code. The inverter does not enter failure mode during a warning.

  • **Warning Code 01**: Fan is locked when inverter is on (Audible Alarm: Beep three times every second).
  • **Warning Code 02**: Over temperature (Audible Alarm: None).
  • **Warning Code 03**: Battery is over-charged (Audible Alarm: Beep once every second).
  • **Warning Code 04**: Low battery (Audible Alarm: Beep once every second).
  • **Warning Code 07**: Overload (Audible Alarm: Beep once every 0.5 second).
  • **Warning Code 10**: Output power derating (Audible Alarm: Beep twice every 3 seconds).
  • **Warning Code 15**: PV energy is low (Audible Alarm: Beep twice every 3 seconds).
  • **Warning Code 16**: High AC input (>280VAC) during BUS soft start (Audible Alarm: None).
  • **Warning Code E9**: Battery equalization (Audible Alarm: None).
  • **Warning Code bP**: Battery is not connected (Audible Alarm: None).

For detailed troubleshooting steps for each warning code, refer to the full user manual (PDF).

8. Technical Specifications

Below are the detailed technical specifications for the PowMr POW-HVM12KP Hybrid Solar Inverter.

Category Specification
AC Input
Input SourcesL+N+PE
Rated Input Voltage220/230/240VAC
Voltage Range90-280VAC±3V (APL Mode); 170-280VAC±3V (UPS Mode)
Frequency50Hz/60Hz (Auto Adaptive)
Inverter Output
Rated Power (Battery Inverter)11000W
Rated Power (Photovoltaic Inverter)12000W (when PV input power ≥ 2000W)
Output Voltage220/230/240VAC±5%
Output Frequency50Hz/60Hz±0.1%
WaveformPure Sine Wave
Transfer Time (Adjustable)Computers (UPS Mode) 10ms, Appliance (APL Mode) 20ms
Peak Power22000VA
Overload CapacityBattery mode: 11s@105%~150%Load; 2s@150%~200%Load; 400ms@>200%Load
Grid-Connected Operation
Output Voltage220/230/240VAC±5%
Feed Into the Grid Voltage Range100-280VAC
Feed Into the Grid Frequency Range47-53±1Hz/57-62±1Hz
Nominal Output Current47.8A
Power Factor Range>0.99
Maximum Conversion Efficiency (DC/AC)98%
Battery
Battery Voltage48Vdc
Constant Charging Voltage (Adjustable)56.4Vdc
Float Charging Voltage (Adjustable)54Vdc
PV Input
PV Charging ModeDual MPPT
MAX. PV Input Power7500W/7500W
MPPT Tracking Range90-500Vdc
Operating Voltage360-430V
MAX. PV Input Voltage500Vdc
PV Max Input Current27A/27A
MAX. PV Charging Current150A
MAX. AC Charging Current150A
MAX. Charging Current150A
Display
LCD InterfaceCAN display running mode/load/input/output, etc.
Interface
RS232Baud Rate 2400
Extend the Socket Communication InterfaceLithium Battery BMS Communication Card, WiFi Card, Dry Contact
Parallel Machine InterfaceParallel Machine (network) function
General Specifications
Operating Temperature-10°C~50°C
Humidity20%~95% (Non-condensing)
Storage Temperature-15°C~60°C
AltitudeNot Over 1000m, Derating over 1000m, Max 4000m, Refer to IEC62040
Noise≤50db
Standards and certificationEN-IEC 60335-1, EN IEC 60335-2-29, IEC 62109-1

9. User Tips

  • Wi-Fi Connectivity: The inverter supports an optional WiFi module for monitoring. If you wish to connect to Wi-Fi, ensure you have the correct module installed and follow the instructions provided with the module for setup. The main manual covers RS232/RS485/CAN communication, with WiFi being an optional extension.

10. Warranty and Support

For any questions, technical support, or warranty claims, please contact PowMr directly using the information below:

  • Tel/Fax: +86 755-28219903
  • Email: support@powmr.com
  • Web: www.powmr.com
  • Address: Henggang Street, Longgang District, Shenzhen, Guangdong, China

Please have your model number (POW-HVM12KP) and any relevant fault codes ready when contacting support.

A user manual in PDF format is available for download from the manufacturer's website or can be requested via email for more detailed instructions and diagrams.