PowMr POW-M60-ULTRA

Contents

PowMr M60 ULTRA 60A MPPT Solar Charge Controller

Model: POW-M60-ULTRA | Brand: PowMr

1. Product Introduction

Welcome to the POW-M60 series solar controller. This controller represents advanced innovation in the field of solar technology and is designed to provide exceptional performance and reliability for your solar energy system. The controller is equipped with advanced CNC technology, an LCD display, automated operation, and a Maximum Power Point Tracking (MPPT) battery charging mode. Combined with advanced control technology, it significantly extends the lifespan of your batteries.

The POW-M60 series solar controller is designed to meet the diverse needs of various solar energy systems, whether in standalone systems or other application scenarios. It automatically controls the charging and discharging processes. By optimizing the controller's battery charging and discharging processes, it not only prolongs the battery's lifespan but also enhances the overall system's performance. The controller features self-diagnostic functions and electronic protection, effectively preventing damage to the controller or batteries during installation errors or system faults, ensuring system reliability and stability.

Our POW-M60 series solar controllers are suitable for a wide range of solar energy applications. We offer a user-friendly custom open-program configuration interface, making the configuration process of solar energy systems quicker and smoother. It also provides more possibilities for expanding solar energy systems. Whether you are setting up a small-scale residential standalone solar system or expanding your solar energy project, the POW-M60 series solar controller will be an indispensable partner.

By choosing the POW-M60 series solar controller, you will gain an efficient, sustainable, and secure energy management solution that provides strong support for future energy needs. We are committed to advancing solar technology and delivering outstanding products and services to you.

1.1 Features

  • Integrated Charging Presets: Adaptive charging logic suitable for most battery types (flooded, gel-sealed lead-acid, lithium). Specific parameters are detailed in Section 3.7.
  • Versatile Application: Compatible with 12V/24V/36V/48V system voltages.
  • Multi-Stage Charging Algorithm: Optimizes charging cycles and maintains battery capacity.
  • Maximum Power Point Tracking (MPPT) Technology: Tracks Vmp for maximum power collection, with up to 99.9% tracking efficiency and 98.1% peak conversion efficiency.
  • Customizable Charging Current Limit: Configurable from 2 to 60A to prevent overcharging and extend battery lifespan.
  • Supports Up to 12 Units in Parallel: Allows expansion of solar panel configuration and energy storage capacity. Refer to Section 7 for details.
  • Adaptive Boost Charging: Monitors battery response to determine boost stage duration, preventing overcharging.
  • Durable and Secure (Multiple Electronic Protections): Includes photovoltaic input overcurrent, PV array short circuit, reversed PV polarity, battery overvoltage, battery overdischarge, and over-temperature protection.
  • External Temperature Probe Configuration: Precisely monitors battery temperature to protect the battery by stopping/resuming charging based on temperature thresholds.
  • Forced Air Cooling & Heat Dissipation Backplate: Internal cooling fan and external heat dissipation plate enhance efficiency.
  • One-Click Factory Reset: Long-press the "SET" button to revert all settings to factory defaults.
  • Lithium Battery Activation: Adjusts charging for lithium batteries and activates protected lithium batteries using solar panel energy. Warning: Do not charge lithium batteries when the temperature is below 0°C.
PowMr M60 ULTRA MPPT Solar Controller with key features
PowMr M60 ULTRA MPPT Solar Controller with key features: MPPT Technology, Battery Support, Multiple Protection, Wide Application (Solar, Off-Grid, RV, Marine Systems).
User-Friendly Solar Controller
User-Friendly Solar Controller: Highlighting intuitive operating interface, upgrades, multiple safety mechanisms, and Maximum Power Point Tracking (MPPT) charging mode.
MPPT vs PWM efficiency comparison
Comparison of MPPT (99% efficiency) and PWM (52% efficiency) solar conversion technologies.
Multiple Electronic Protections
Diagram illustrating multiple electronic protections: Reverse Current, Over-Discharging, Overload, Short Circuit, Overcharging, and built-in smart fan operation.
Multi-Protection Functions
Visual representation of multi-protection functions: Photovoltaic input overcurrent, array short circuit, reversed polarity, over-temperature, overvoltage, and overdischarge protection.
Compatible Battery Types
Image showing compatibility with SLA (Sealed Lead-acid), GEL, FLD (Flooded), AGM, and LI (LiFePO4) battery types, with a connected battery and controller display.
Customizable Charging Current Limit
Customizable Charging Current Limit: Allows setting a maximum charging current between 2-60A to prevent excessive charging rates and extend battery lifespan.

2. Important Safety Instructions

WARNING: Carefully read and adhere to all safety instructions.

  • Before installing and operating the controller, please read the user manual thoroughly and keep it for future reference.
  • The installation or operation of the controller should only be performed by individuals who have received proper training and supervision.
  • Anyone lacking the necessary knowledge, experience, or capabilities for the safe installation and operation requirements should not attempt installation.
  • Individuals (including children) who may have physical, sensory, or intellectual impairments that could affect the safe installation and operation should not attempt installation.

Controller Installation and Operation Safety

  • This controller product does not have user-serviceable components; do not disassemble or attempt to repair the controller yourself.
  • Install the controller in a well-ventilated environment with adequate clearance around it.
  • Install the controller on non-combustible walls and ensure there are no flammable materials nearby; it is normal for the controller to generate heat during operation.
  • Place the controller in an environment that is protected from direct sunlight, rain, humidity, and dust, and keep it away from any flammable liquids or gases. The controller is for indoor use only.
  • Do not install or operate the controller on top of, directly above, or in an enclosed space above batteries, as batteries emit explosive gases.
  • Do not place any objects on top of the controller.

Battery Installation and Charging Safety

  • Install and charge batteries in well-ventilated or exhaust-ventilated environments.
  • Ensure there are no open flames in the vicinity of the batteries, as batteries emit explosive gases.
  • Battery acid is corrosive; if battery acid comes into contact with the skin, rinse immediately with clean water.
  • Do not charge non-rechargeable batteries. Do not charge lithium batteries when the temperature is below 0°C. Charging frozen batteries is prohibited.
  • Ensure that the equipment is properly configured for the type of battery connected to it.

DC Battery Connections Safety

  • Ensure that the DC system is fully off/powered down by disconnecting all cables and/or new ports from the battery/DC system.
  • Use flexible, multi-strand copper cables with an appropriate cross-sectional area, and connect them to matching fuses or circuit breakers.
  • Connecting the photovoltaic array to the controller is prohibited until the battery is connected first.

3. Setup: Installation and Wiring

3.1 Unpacking and Inspection

Before unpacking, inspect the packaging for any signs of damage. After unpacking, check the contents to ensure nothing is damaged or missing. Inside the package, you will find the following items:

  • Controller
  • User Manual
  • Installation Guide card
  • Installation screws
  • Parallel Communication Cable
  • Parallel Communication Terminal
  • External temperature sensor

3.2 Choosing the Installation Location

Before installation, several aspects should be considered to determine or provide a suitable and safe installation location:

  • Install the controller in a space with good natural ventilation/exhaust.
  • Avoid direct sunlight.
  • Ensure there is ample clearance around the controller. The minimum clearance at the top, bottom, and both sides of the controller is 75mm.
  • Install the controller on a non-combustible wall and ensure there are no flammable materials nearby; an increase in temperature during controller operation is a normal occurrence.
  • Install the controller in an environment that avoids direct sunlight, rain, humidity, and dust, and keep it away from any flammable liquids or gases. The controller is for indoor use only.
  • Do not install or operate the controller on top of, directly above, or in an enclosed space above batteries, as batteries emit explosive gases.
  • When running multiple controllers in parallel, ensure they are installed at the same horizontal height, with a minimum spacing of 75mm between controllers.

3.3 Wiring Precautions

  1. Installation and wiring work should be carried out by a certified electrician.
  2. Wiring should follow the sequence of Battery > PV Input > Load.
  3. To avoid short-circuits and polarity reversal, pay attention to connecting the positive (+) cable to the device's positive (+) terminal and the negative (-) cable to the device's negative (-) terminal.
  4. Loose and/or incomplete connections can lead to cable or terminal overheating. Therefore, tighten all cables to minimize transition resistance, using cable sizes appropriate for the specific circuit's current rating.
  5. Do not connect the inverter to the load terminal of the controller, as doing so may result in irreversible damage to the equipment. If it is necessary to connect the inverter, please follow the battery connection steps outlined in Section 3.4, as indicated in the wiring diagram.

3.4 Installation and Wiring Guidelines

Please refer to the following steps to complete the installation and wiring of the controller.

Step 1. Mount the Controller

Install the controller vertically with its ports facing downward, securing it to the wall through the four mounting holes using screws. For ease of installation, it is recommended to use two upper screws for initial "hanging" of the device, followed by the addition of two lower screws, and then fully tighten all four screws.

Built-in Dedicated Wiring Terminals & Max Input Power
Built-in Dedicated Wiring Terminals & Max Input Power: Wiring diagram showing solar panels connected to the controller, then to a battery and load, with maximum input power specifications for 12V, 24V, 36V, and 48V systems.

Step 2. Battery Wiring

Connect the battery to the controller using cables.

Attention: Do not connect the inverter to the load terminal of the controller; otherwise, it may cause irreversible damage to the equipment. If it is necessary to connect the inverter, please refer to the diagram below.

How to Install the System - Detailed Wiring Diagram
Detailed step-by-step wiring diagram for installing the solar system, including battery, inverter, solar panel, and circuit breaker connections.

Note:

  • All wiring work must be carried out by professionals.
  • For safe operation and proper application, circuit breakers of the appropriate specifications must be installed on the cables connected to the controller, and ensure that the connections are tight.
  • Ensure that all circuit breakers are in the off position before completing all wiring.
  • Connect the positive cable terminal to the positive terminal port, and the negative cable terminal to the negative terminal port.
  • The above notes also apply to the PV ports and DC output ports.

Step 3. PV Wiring

Connect the photovoltaic array to the controller using cables.

Step 4. DC Output Wiring

Connect the load to the controller using cables.

Step 5. Temperature Probe Connection

Connect the temperature probe wire to the controller and securely fix the probe end to the battery using insulation tape.

Step 6. Pre-Startup Check

Refer to the wiring diagram. If all connections are accurate, and all wiring is securely connected, close the circuit breakers in the order of Battery, PV Input, and Load terminals.

WARNING: Risk of Electric Shock! Before wiring, ensure that all power sources are turned off and follow the relevant inspection and operation procedures.

3.5 Parallel Installation and Wiring

Step 1. Install parallel devices at the same height level with a minimum distance of approximately 75mm between devices.

Parallel Operation Schematic
Parallel Operation Schematic: Showing up to 12 units of solar controllers operating in parallel, connected to multiple solar arrays and a single battery pack.

Step 2. Connect communication lines.

Step 3. Connect all parallel controllers to the same battery bank in sequence.

Step 4. Then, individually connect each controller to its respective photovoltaic array.

Step 5. Finally, connect each controller to the DC load.

Step 6. Set the parallel communication code for each controller; refer to the parallel communication code settings described in Section 4.6.

WARNING: To ensure the proper operation of the controllers, it is prohibited to use controllers of different brands or models in parallel.

4. Operation Guide

4.1 LCD Screen Icon Display

The LCD screen provides real-time information about the controller's operation. Here's a breakdown of the icons:

No.IconDescription
1Day/Night IndicatorIndicates whether photovoltaic input is currently present.
2Battery Level IconIndicates the remaining battery capacity.
3Operation Mode/Error CodeDisplays the current operation mode (see Section 4.3)/error code.
4Load Status IconIndicates the periodic operating status and alarm status of the load (see Section 5.2).
5PV Input InformationShows the photovoltaic input voltage/power/total energy generated.
6Battery InformationDisplays the current battery voltage/charging current/device temperature/battery calibration voltage/parallel communication code/battery type/equalization charging voltage/float charging voltage/DC undervoltage recovery voltage/DC undervoltage cutoff voltage.
7Load Operating ModeIndicates the load operation mode.

4.2 Key Introduction

Function KeyActionDescription
PV/Browse ModeSwitch PV Input Parameters
BAT/▲Browse ModeShort press to toggle battery information (move to the next option)
Long pressEnter battery parameter settings
Set ModeIncrease Value
DC/▼Browse ModeShort press to toggle battery information (return to the previous option)
Long pressEnter load operation mode settings
Set ModeDecrease Value
SET/⚙Short pressConfirm and Save Settings
Long PressRestore Factory Settings

Note: When long pressing SET/⚙ and BAT/▲, please disconnect the PV input to ensure that the settings are made while the battery is not charging.

4.3 Operating Modes

The controller operates in various modes, indicated by codes on the LCD screen:

CodeDescription
3.0Night Mode, No Charging
4.0MPPT Mode
7.0Boost Charging Mode (Constant Voltage Charging)
8.0Float Charging Mode

Note: In the event of a fault, the operation mode section will display the fault code. For details, please refer to section 5.2.

4.4 PV Parameters Overview

Press the PV / button briefly to switch the data displayed on the left side of the screen:

  • PV Input Voltage
  • PV Input Power
  • Total Energy Generation

4.5 Battery Parameters Overview and Settings

In browsing mode, use the BAT/▲ and DC/▼ buttons to scroll through the battery parameters. When you reach the parameter you wish to set, press and hold the BAT/▲ button to enter the parameter setting mode. Once in the specific parameter's setting mode, adjust the values or scroll through options using the BAT/▲ and DC/▼ buttons, and press the SET / ⚙ button to confirm the settings.

Note: Before long pressing BAT/▲ to set the battery parameters, please switch off the PV input to ensure that the battery is not in a charging state.

Battery Calibration Voltage

If there is a discrepancy between the battery voltage detected by the controller and the value measured with a multimeter, this setting can be used to calibrate the battery voltage.

Communication Code for Parallel Operation

If parallel operation is not used, this setting does not need to be configured. After completing the parallel wiring, use this setting to define the master and slave units. The controller with the lowest communication code value will be the master. In a parallel operation, if the master fails, the system will automatically select the controller with the next highest communication code value as the new master. For example, if Master Unit 01 fails, the system will designate Unit 02 as the new master. Assuming 6 controllers are operating in parallel, assign communication codes from 01 to 06 to each unit (each unit's communication code should be unique).

Code010203040506
Scenario 1: Normal operationMasterSlaveSlaveSlaveSlaveSlave
Scenario 2: 01 failsFailureMasterSlaveSlaveSlaveSlave
Scenario 3: 03 failsMasterSlaveFailureSlaveSlaveSlave
Scenario 4: 01 and 02 failFailureFailureMasterSlaveSlaveSlave

Battery Type Selection

Please select the battery type according to the connected battery by referring to the table below. Press and hold the BAT/▲ button to enter the setting program, use the BAT/▲ and DC/▼ buttons to select the battery type, and press the SET / ⚙ button to save and confirm. If "User Defined" is selected, you can set the following battery parameters.

SequenceDisplayBattery Type
1SELLead-acid Battery (Default)
2GELGel Sealed Lead-acid Battery
3FLdFlooded Lead-acid Battery
4L044-Cell Lithium Iron Phosphate Battery
5L077-Cell Lithium Iron Phosphate Battery
6L088-Cell Lithium Iron Phosphate Battery
7L1515-Cell Lithium Iron Phosphate Battery
8L1616-Cell Lithium Iron Phosphate Battery
9N033-Cell Ternary Lithium Battery
10N066-Cell Ternary Lithium Battery
11N077-Cell Ternary Lithium Battery
12N1313-Cell Ternary Lithium Battery
13N1414-Cell Ternary Lithium Battery
14USECustom Battery Type

Custom Charging Parameters (if "USE" is selected)

  • System Voltage: Available options: 12V/24V/36V/48V.
  • Max. Charging Current: Setting range is: 2~60A, with a step size of 1A.
  • Boost Charging Voltage: Setting range is: 9.0~17.0V, with a step size of 0.1V.
  • Float Charging Voltage: Setting range is: 9.0~17.0V, with a step size of 0.1V.
  • Under-Voltage Recovery Voltage: Setting range is: 9.0~17.0V, with a step size of 0.1V.
  • Under-Voltage Cutoff Voltage: Setting range is: 9.0~17.0V, with a step size of 0.1V.

Note: The charging parameters for lead-acid batteries and user-defined batteries listed in the above table are for a 12V system voltage. For a 24V system voltage, these values should be multiplied by 2. If a lead-acid or user-defined battery with a 24V system voltage is connected, the actual charging voltage will be twice the value displayed on the screen.

4.6 Load Operation Mode Settings

To access the load operation mode settings, press and hold the DC/▼ button. Then use the BAT/▲ and DC/▼ buttons to switch between options, and press the SET / ⚙ button to save and confirm.

Mode CodeDescription
00HLight Control Mode (Load output starts after sunset and stops at sunrise).
24HImmediate Load On (Press the SET button to immediately turn off the load output).
01H~23HAdjust the duration of load activation (The value indicates the duration, e.g., 01H for 1 hour, 02H for 2 hours).

5. Maintenance

We recommend conducting the following checks and maintenance at least twice a year to ensure optimal performance:

  1. Ensure the controller is securely mounted in a clean and dry environment.
  2. Ensure proper airflow around the controller and clean any dust or debris from the heat sinks.
  3. Inspect all exposed wires for insulation damage, such as severe sun exposure, friction wear, dryness, insect or rodent damage. Repair or replace any damaged wires as necessary.
  4. Tighten all terminals and check for loose, broken, or burnt cable connections.
  5. Confirm that all system components are properly grounded.
  6. Ensure all terminals are free from corrosion, insulation damage, high temperatures, or signs of burning/discoloration, and tighten terminal screws.
  7. Check for dirt, nesting insects, and corrosion. If present, clean promptly.

WARNING: Risk of electric shock! Before performing the above operations, ensure that all power sources are turned off and then follow the relevant check and operation guidelines.

6. Troubleshooting

6.1 Protection Function Overview

ProtectionDescription
Photovoltaic Input OvercurrentThe controller limits the battery charging current to the maximum battery current rating. Consequently, an overcurrent from the photovoltaic array input will not allow it to operate at peak power.
Photovoltaic Array Short CircuitWhen a short circuit occurs in the photovoltaic array, the controller will stop charging, and operation can be restored by eliminating the short circuit fault.
Photovoltaic Polarity ReversalIf the photovoltaic input wiring polarity is reversed, the controller will not operate, and it will not damage the controller. After proper reconnection, the controller will operate normally.
Battery OvervoltageWhen the battery voltage exceeds 15.5/31.0/46.5/62.0V, the controller will stop charging to protect the battery from overcharging damage. Please note that stopping the charging means the charging current is very low.
Battery Over-dischargeWhen the battery voltage drops to the low-voltage disconnect setpoint, the controller will stop discharging to protect the battery from over-discharge damage.
Over-temperature ProtectionWhen the temperature of the controller's heat sink exceeds 65°C, the controller will automatically begin to reduce the charging current. When the temperature exceeds 80°C, the controller will automatically shut down.

6.2 Troubleshooting Guide

Fault CodeDescriptionResolution
18Photovoltaic Input Voltage Too LowIncrease the photovoltaic array voltage by changing the series-parallel connection or adding more solar panels.
60Over-temperature ProtectionIn case of over-temperature, the fan will start automatically to provide efficient forced cooling.
63Battery OvervoltageCharging will automatically stop, and it will resume when the battery voltage returns to normal levels.
65Battery UndervoltageDischarging will automatically stop, and it will resume when the battery voltage rises to normal levels.
71Photovoltaic Input Voltage Too HighReduce the photovoltaic array voltage by changing the series-parallel connection or reducing the number of solar panels.
73Overcharging CurrentReduce the photovoltaic input power by decreasing the number of solar panels.

7. Specifications

CategoryItemPOW-M60-ULTRA
Solar Input Parameters
Maximum Input PowerFor 12V System720W
For 24V System1440W
For 36V System2100W
For 48V System2800W
Input Voltage RangeFor 12V System20V~80V
For 24V System37V~105V
For 36V System50V~160V
For 48V System72V~160V
Battery Charging Parameters
Charging TechnologyMPPT
Charging Algorithm3 stages
Battery Voltage Range9~60V
Rated Charging Current60A
Maximum Efficiency≥98.1%
Solar Utilization Rate≥99%
Self-consumption0.7W-1.2W
Load Terminal Output
Rated Output Current25A
Max. Capacitive Load Capacity10000μF
Environmental Parameters
Operating Temperature Range-35°C~+45°C
Humidity Range≤95%, non-condensing
Altitude<3000m
General Specification
Protection LevelIP32
Dimensions (L×W×H)221x163x77mm / 8.7x6.42x3.03in
Net Weight1442g / 3.18lb

8. Warranty and Support

8.1 Warranty Services

Thank you for choosing the POW-M60 series solar controller. Please carefully read this manual as it will help you maximize the many advantages the controller offers for your solar system. This manual provides important recommendations regarding installation and usage. For your own benefit, please read and pay close attention to the safety advice within.

In accordance with the instructions, repair services may be provided to users for any damaged units resulting from incorrect installation, disassembly, or improper use of this product.

Warranty Terms:

  • Within 30 days from the date of purchase, a malfunctioning controller will be replaced at no charge, provided that it has been used under normal circumstances and authorized by the company's technical personnel.
  • Within 2 years from the date of purchase, a malfunctioning controller will be repaired at no charge.

NOTE: Unauthorized disassembly voids the warranty.

8.2 Declaration (Warranty Exclusions)

Under the following circumstances, our company reserves the right not to assume any quality warranty responsibilities:

  • Damage caused by improper transportation.
  • Damage resulting from incorrect storage, installation, or usage.
  • Damage caused by non-professionals or untrained personnel installing and operating the equipment.
  • Damage resulting from non-compliance with the instructions and safety warnings in this document.
  • Damage caused by operation in environments that do not meet the requirements specified in this document.
  • Damage due to operation beyond the parameter ranges specified in applicable technical specifications.
  • Damage resulting from unauthorized disassembly, product alteration, or software code modification.
  • Damage caused by abnormal natural conditions (force majeure), such as lightning, earthquakes, fires, storms, etc.
  • Any damage resulting from failure to adhere to local standards and regulations during the installation and operation processes.
  • Products outside the warranty period.

9. User Tips

  • Optimal Placement: Always ensure the controller is installed in a well-ventilated area, away from direct sunlight and moisture, to prevent overheating and ensure longevity.
  • Wiring Sequence is Crucial: Strictly follow the wiring order: Battery first, then PV array, and finally the load. Incorrect sequence can damage the unit.
  • Battery Compatibility: Double-check that the selected battery type in the controller settings matches your actual battery to ensure proper charging and prevent damage.
  • Parallel Operation: When using multiple controllers in parallel, ensure they are of the same model and brand, and assign unique communication codes as per the manual.
  • Regular Checks: Perform periodic maintenance checks on wiring connections, heat sinks, and overall cleanliness to maintain optimal performance and safety.
  • Inverter Connection: Always connect inverters directly to the battery bank, not to the controller's load terminals, to avoid irreversible damage.

For further assistance, please contact PowMr support.

SHENZHEN HEHEJIN INDUSTRIAL CO.,LTD
Tel/Fax: +86755-28219903
Email: support@powmr.com
Web: www.powmr.com
Add: Henggang Street, Longgang District, Shenzhen, Guangdong, China

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.