1. Introduction
This manual describes the assembly, installation, operation, and troubleshooting of the Daxtromn 4.2kW Hybrid Solar Inverter. Please read this manual carefully before installation and operation. Keep this manual for future reference.
1.1. Product Features
- Pure sine wave output.
- Output power factor 1.0.
- Built-in MPPT 120A solar charger.
- Photovoltaic input voltage range: 60-500VDC.
- Capable of working without a battery.
- Optional WiFi remote monitoring.
- Supports multiple output priorities: USB, SUB, SBU.
- Removable dust cover for harsh environments.
- One-key factory reset function.
- Supports PACE PYLON communication protocol BMS.
- Connects to lithium iron phosphate batteries via RS485 interface.
- Lithium battery activation function (via mains or photovoltaic system).
- Features two load outputs.
- Can be connected to the grid (on-grid/off-grid capability).
- Built-in RS232 (WIFI) / RS485 (BMS) port for configuring BMS battery charging protocols.
1.2. Basic System Architecture
The inverter integrates functions of an inverter, solar charger, and battery charger to provide uninterruptible power support. It can power various appliances in home or office environments, including motor-type appliances.

This diagram illustrates how the hybrid solar inverter connects solar power, a generator or utility grid, and external battery packs to supply power to home appliances.
2. Safety Instructions
WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.
- Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
- CAUTION: To reduce the risk of injury, charge only deep-cycle lead-acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
- Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
- To reduce the risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
- CAUTION: Only qualified personnel can install this device with a battery.
- NEVER charge a frozen battery.
- For optimum operation, follow the required specifications to select the appropriate cable size.
- Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool, spark, or short-circuit batteries or other electrical parts, which could cause an explosion.
- Strictly follow the installation procedure when disconnecting AC or DC terminals. Refer to the INSTALLATION section.
- A 150A fuse is provided for over-current protection for the battery supply.
- GROUNDING INSTRUCTIONS: This inverter/charger should be connected to a permanent grounded wiring system. Comply with local requirements and regulations.
- NEVER cause AC output and DC input short-circuited. Do NOT connect to the mains when DC input short-circuits.
- Warning! Only qualified service persons are able to service this device. If errors persist after following the troubleshooting table, send this inverter/charger back to a local dealer or service center.
3. Product Overview
The Daxtromn 4.2kW Hybrid Solar Inverter features a comprehensive LCD display and various connection ports for seamless integration into your solar power system.

This image details the front panel and connection ports of the inverter.
3.1. Front Panel and Indicators
- LCD display
- Status indicator
- Charging indicator
- Fault indicator
- Function buttons
3.2. Connection Ports
- Power on/off switch
- AC input
- Main output
- Second output
- Battery input
- PV input
- Anti-dust kit
- WIFI communication/RS-232 port
- Battery communication/RS-485 port

Various views of the inverter, showcasing its design and port layout.
4. Setup (Installation)
4.1. Unpacking and Inspection
Before installation, inspect the unit for any damage. The package should contain:
- The inverter unit x 1
- User manual x 1
4.2. Preparation
Before connecting any lines, remove the screws under the machine and remove the bottom cover plate.
4.3. Mounting the Unit
Consider the following points for installation:
- Do not mount on flammable construction materials.
- Mount on a solid surface.
- Install at eye level for easy LCD display reading.
- Allow approx. 20 cm clearance on sides and 50 cm above/below for proper air circulation.
- Ambient temperature should be between 0°C and 55°C for optimal operation.
- Adhere to vertical wall mounting.
- Ensure enough space for heat dissipation and wire removal.
SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.
Install the unit using two M6 screws.
4.4. Battery Connection
CAUTION: Install a separate DC over-current protector or disconnect device between the battery and inverter.
WARNING! All wiring must be performed by qualified personnel. Use appropriate cable sizes.

This image provides recommended battery cable sizes and diagrams for connecting 12V batteries in series for 4.2KW and 6.2KW inverters.
Recommended battery cable size:
| Model | Wire Size | Cable (mm²) | Torque value (max) |
|---|---|---|---|
| 3.6KW/4.2KW/6.2KW | 1 x 2AWG | 25 | 2 Nm |
Connection Steps:
- Remove 18 mm insulation sleeve from positive and negative conductors.
- Suggest using bootlace ferrules with a proper crimping tool.
- Connect all battery packs as per the diagram (Figure 4).
- Insert battery wires into inverter connectors, tighten bolts to 2 Nm. Ensure correct polarity.
WARNING: Shock Hazard! Installation must be performed with care due to high battery voltage in series.
CAUTION: Before final DC connection, ensure positive (+) is connected to positive (+) and negative (-) to negative (-).
4.5. AC Input/Output Connection
CAUTION: Install a separate AC breaker between the inverter and AC input power source. Recommended spec: 32A for 3.6KW/4.2KW, 50A for 6.2KW.
CAUTION: Do NOT mis-connect input and output connectors (marked "IN" and "OUT").
WARNING! All wiring must be performed by qualified personnel. Use appropriate cable sizes.

This image details the suggested cable requirements for AC wires and illustrates the connection process.
Suggested cable requirement for AC wires:
| Model | Gauge | Cable (mm²) | Torque Value |
|---|---|---|---|
| 3.6KW/4.2KW | 12 AWG | 4 | 1.2 Nm |
| 6.2KW | 10 AWG | 6 | 1.2 Nm |
Connection Steps:
- Open DC protector or disconnector first.
- Remove 10mm insulation sleeve for six conductors; shorten phase L and neutral N by 3mm.
- Insert AC input wires according to polarities (L: brown/black, N: blue) and tighten screws.
- WARNING: Disconnect AC power source before hardwiring.
- Insert AC output wires according to polarities (L: brown/black, N: blue) and tighten screws.
- Ensure wires are securely connected.
CAUTION: Appliances like air conditioners require 2-3 minutes to restart. Check if your appliance has a time-delay function to prevent damage from short power outages.
4.6. PV Connection
CAUTION: Install a separate DC circuit breaker between the inverter and PV modules.
WARNING! Use appropriate cable sizes for PV module connection.

This image shows a typical PV system setup, cable requirements, and parameters for selecting PV modules.
Recommended PV cable size:
| Model | Wire Size | Cable (mm²) | Torque value (max) |
|---|---|---|---|
| 3.6KW/4.2KW/6.2KW | 1 x 12AWG | 4 | 1.2 Nm |
PV Module Selection Parameters:
- Open circuit Voltage (Voc) of PV modules must not exceed max. PV array open circuit voltage of inverter (500Vdc).
- Open circuit Voltage (Voc) of PV modules should be higher than min. battery voltage.
- MPPT Range operation Voltage: 60-500VDC.
4.7. Final Assembly
After connecting all wirings, replace the bottom cover by screwing two screws.
4.8. Communication Connection
Wi-Fi Cloud Communication (Option): Use the supplied cable to connect to the inverter and Wi-Fi module. Download the APP and follow the