Daxtromn AGH-6.2KW-48V

Contents

Daxtromn 6.2KW Hybrid Solar Inverter User Manual

Model: AGH-6.2KW-48V | Brand: Daxtromn

Daxtromn 6.2KW Hybrid Solar Inverter Front View

Front view of the Daxtromn 6.2KW Hybrid Solar Inverter, highlighting key specifications.

1. Introduction

This manual describes the assembly, installation, operation, and troubleshooting of the Daxtromn AGH-6.2KW-48V Hybrid Solar Inverter. Please read this manual carefully before installations and operations. Keep this manual for future reference.

The Daxtromn Hybrid Solar Inverter is a multi-function inverter/charger, combining the functions of an inverter, solar charger, and battery charger to provide uninterruptible power support. It features a comprehensive LCD display for user-configurable settings such as battery charging current, AC/solar charger priority, and acceptable input voltage for various applications.

1.1 Features

  • Pure sine wave output.
  • Output power factor 1.0.
  • Built-in MPPT 120A solar charger.
  • Photovoltaic (PV) input voltage range: 60-500VDC.
  • Capable of working without a battery.
  • Optional WiFi remote monitoring.
  • Supports multiple output priorities: USB (Utility first), SUB (Solar first), SBU (Solar-Battery-Utility).
  • Removable dust cover, suitable for harsh environments.
  • Can be connected to the grid.
  • Supports PACE and PYLON communication protocols for Battery Management Systems (BMS).
  • Connects to lithium iron phosphate batteries via RS485 interface.
  • Lithium battery activation function, activatable by mains or photovoltaic system.
  • Features two load outputs.
  • One-key factory reset function.
  • Built-in RS232 (WIFI) / RS485 (BMS) port for configuring BMS battery charging protocols to extend battery life.
  • Configurable input voltage range for home appliances and personal computers via LCD setting.
  • Configurable battery charging current based on applications via LCD setting.
  • Configurable AC/Solar Charger priority via LCD setting.
  • Compatible with mains voltage or generator power.
  • Auto restart while AC is recovering.
  • Overload, over temperature, and short circuit protection.
  • Smart battery charger design for optimized battery performance.
  • Cold start function.

1.2 Basic System Architecture

The inverter integrates into a hybrid power system, connecting solar power, utility, generator, and external battery packs to power home appliances. Consult with your system integrator for specific system architectures based on your requirements.

Hybrid Power System Connection Diagram

Connection Diagram illustrating how the solar inverter connects to various power sources and loads.

2. Safety Instructions

WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.

  1. Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
  2. CAUTION: To reduce the risk of injury, charge only deep-cycle lead-acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
  3. Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
  4. To reduce the risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
  5. CAUTION: Only qualified personnel can install this device with a battery.
  6. NEVER charge a frozen battery.
  7. For optimum operation of this inverter/charger, please follow the required specifications to select appropriate cable sizes. It is very important to correctly operate this inverter/charger.
  8. Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts, which could cause an explosion.
  9. Please strictly follow the installation procedure when you want to disconnect AC or DC terminals. Refer to the INSTALLATION section of this manual for details.
  10. One piece of 150A fuse is provided as over-current protection for the battery supply.
  11. GROUNDING INSTRUCTIONS: This inverter/charger should be connected to a permanent grounded wiring system. Be sure to comply with local requirements and regulations to install this inverter.
  12. NEVER cause AC output and DC input short-circuited. Do NOT connect to the mains when DC input short circuits.
  13. Warning!! Only qualified service persons are able to service this device. If errors still persist after following the troubleshooting table, please send this inverter/charger back to a local dealer or service center for maintenance.

3. Product Overview

The inverter features an intuitive design with an LCD display and various ports for connectivity and operation.

Product Overview with Labeled Components

Diagram showing the inverter's external components and their labels.

3.1 Components

  1. LCD display
  2. Status indicator
  3. Charging indicator
  4. Fault indicator
  5. Function buttons
  6. Power on/off switch
  7. AC input
  8. Main output
  9. Second output
  10. Battery input
  11. PV input
  12. Anti dust kit
  13. WIFI communication/RS-232 port
  14. Battery communication/RS-485 port
Product Display Views

Multiple views of the inverter, highlighting its physical design and various ports.

4. Installation

4.1 Unpacking and Inspection

Before installation, inspect the unit. Ensure that nothing inside the package is damaged. You should have received the unit and this user manual.

4.2 Preparation

Before connecting any lines, remove the screws under the machine and remove the bottom cover plate.

4.3 Mounting the Unit

Consider the following points when selecting where to install the inverter:

  • Do not mount the inverter on flammable construction materials.
  • Mount on a solid surface.
  • Install this inverter at eye level to allow the LCD display to be read at all times.
  • For proper air circulation to dissipate heat, allow a clearance of approximately 20 cm to the sides and 50 cm above and below the unit.
  • The ambient temperature should be between 0°C and 55°C to ensure optimal operation.
  • The recommended installation position is vertically on the wall.
  • Ensure sufficient space around the machine for adequate heat dissipation and wire access.

SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.

Install the unit by screwing two M6 screws.

4.4 Battery Connection

CAUTION:

  • For safety and regulation compliance, install a separate DC over-current protector or disconnect device between the battery and inverter.
  • WARNING! All wiring must be performed by qualified personnel.
  • WARNING! Use appropriate cable for battery connection to reduce risk of injury.
Model Wire Size Cable (mm²) Torque Value (max)
3.6KW/4.2KW/6.2KW 1 x 2AWG 25 2 Nm

Battery Connection Steps:

  1. Remove 18 mm of insulation sleeve for positive and negative conductors.
  2. Put bootlace ferrules on the end of positive and negative wires with a proper crimping tool.
  3. Connect all battery packs as shown in the diagram below.
  4. Insert the battery wires flatly into the inverter's battery connectors and ensure bolts are tightened with a torque of 2 Nm in a clockwise direction. Ensure correct polarity.
Battery Connection Diagram

Diagram showing battery connections for 3.6KW/4.2KW and 6.2KW models.

Battery Wire Preparation and Connection

Visual guide for preparing and connecting battery wires.

WARNING: Shock Hazard! Installation must be performed with care due to high battery voltage in series.

CAUTION!! Before making the final DC connection or closing the DC breaker/disconnector, ensure positive (+) is connected to positive (+) and negative (-) to negative (-).

4.5 AC Input/Output Connection

CAUTION!!

  • Install a separate AC breaker between the inverter and AC input power source. Recommended spec: 32A for 3.6KW/4.2KW and 50A for 6.2KW.
  • Do NOT mis-connect input and output connectors.
  • WARNING! All wiring must be performed by qualified personnel.
  • WARNING! Use appropriate cable for AC input connection.

Suggested Cable Requirement for AC Wires:

Model Gauge Cable (mm²) Torque Value
3.6KW/4.2KW 12 AWG 4 1.2 Nm
6.2KW 10 AWG 6 1.2 Nm

AC Input/Output Connection Steps:

  1. Before making AC input/output connection, open the DC protector or disconnector first.
  2. Remove 10mm of insulation sleeve for six conductors. Shorten phase L and neutral conductor N by 3 mm.
  3. Insert AC input wires according to polarities indicated on the terminal block and tighten the terminal screws (L=LINE (brown or black), N=Neutral (blue)).
  4. WARNING: Ensure AC power source is disconnected before hardwiring.
  5. Insert AC output wires according to polarities indicated on the terminal block and tighten terminal screws (L=LINE (brown or black), N=Neutral (blue)).
  6. Make sure the wires are securely connected.
AC Input/Output Connection Diagram

Diagram illustrating the process of preparing and connecting AC wires.

CAUTION: Appliances like air conditioners require 2-3 minutes to restart. If power fluctuates rapidly, it can damage appliances. Check if your appliance has a time-delay function.

4.6 PV Connection

CAUTION: Before connecting to PV modules, install a separate DC circuit breaker between the inverter and PV modules.

WARNING! Use appropriate cable for PV module connection.

Model Wire Size Cable (mm²) Torque Value (max)
3.6KW/4.2KW/6.2KW 1 x 12AWG 4 1.2 Nm

PV Module Selection:

When selecting PV modules, consider the following parameters:

  • Open circuit Voltage (Voc) of PV modules must not exceed the max. PV array open circuit voltage of the inverter.
  • Open circuit Voltage (Voc) of PV modules should be higher than the min. battery voltage.
INVERTER MODEL 3.6KW/4.2KW 6.2KW
Max. PV Array Open Circuit Voltage 500Vdc
PV Array MPPT Voltage Range 60Vdc~450Vdc

PV Module Wire Connection Steps:

  1. Remove 10 mm of insulation sleeve for positive and negative conductors.
  2. Put bootlace ferrules on the end of positive and negative wires with a proper crimping tool.
  3. Check correct polarity of wire connection from PV modules and PV input connectors. Connect positive pole (+) to positive pole (+) and negative pole (-) to negative pole (-). Recommended tool: 4mm blade screwdriver.
PV Connection Diagram

Diagram showing the preparation of PV module wires and their connection.

4.7 Final Assembly

After connecting all wirings, put the bottom cover back by screwing two screws.

4.8 Communication Connection

  1. Wi-Fi Cloud Communication (Option): Use the supplied communication cable to connect to the inverter and Wi-Fi module. Download the APP and refer to the "Wi-Fi Plug Quick Installation Guideline" for setup.
  2. GPRS Cloud Communication (Option): Use the supplied communication cable to connect to the inverter and GPRS module, then apply external power to the GPRS module. Download the APP and refer to the "GPRS RTU Quick Installation Guideline" for setup.
  3. Battery Communication: Communication between the battery and the inverter is realized through the battery communication interface (Baud rate: 9600).
  4. Lithium Battery and Inverter Connection: Use power cables and communication cables for lithium batteries. Ensure correct polarity. The RJ45 connector of the communication cable connects to the BMS port of the inverter, and the other RJ45 connector connects to the RS485 port of the lithium battery. Turn off both before connecting.
Lithium Battery Communication Cable Interface

Diagram detailing the pinout for RJ45 connectors and their connection for lithium battery communication.

5. Operation

5.1 Power ON/OFF

Once the unit is properly installed and batteries are connected, simply press the On/Off switch (located on the side of the case) to turn on the unit.

5.2 Operation and Display Panel

The front panel includes three indicators, four function keys, and an LCD display, showing operating status and input/output power information.

LED Indicator Messages:

LED Indicator State Message
INV/AC (Green)Solid OnOutput is powered by utility in Line mode.
INV/AC (Green)FlashingOutput is powered by battery or PV in battery mode.
CHG (Green)Solid OnBattery is fully charged.
CHG (Green)FlashingBattery is charging.
FAULT (Red)Solid OnFault occurs in the inverter.
FAULT (Red)FlashingWarning condition occurs in the inverter.

Function Key Descriptions:

Function Key Description
ESCTo exit setting mode
UPTo go to previous selection
DOWNTo go to next selection
ENTERTo confirm the selection in setting mode or enter setting mode

The LCD display icons provide information on input source, configuration, faults, output, battery, load, and operating mode. Refer to pages 12-14 of the PDF manual for detailed icon descriptions.

5.3 LCD Setting

To enter setting mode, press and hold the ENTER button for 3 seconds. Use UP/DOWN to select programs and ENTER to confirm, or ESC to exit. Detailed setting programs are available on pages 15-24 of the PDF manual, covering:

  • Output source priority (Utility first, Solar first, SBU priority)
  • Maximum charging current
  • AC input voltage range
  • Battery type (AGM, Flooded, User-Defined, LIB for Lithium)
  • Auto restart settings
  • Output frequency and voltage
  • Battery equalization settings
  • GRID-tie current
  • LED pattern light
  • Dual output functional voltage point
  • BMS communication address settings

5.4 Operating Mode Description

The inverter supports various operating modes including Standby, Line, Grid-Tie, and Battery modes. The LCD display will show different information depending on the current mode. Refer to pages 25-32 of the PDF manual for detailed descriptions and LCD examples for each mode, including LIC (Lithium battery communication PACE 232 BMS) and LIL (Lithium battery communication PYLON 485 BMS) modes.

5.5 Battery Equalization Description

The equalization function reverses the buildup of negative chemical effects like stratification and removes sulfate crystals, which can reduce battery capacity. It is recommended to equalize the battery periodically.

Battery Equalization Charging Curve

Diagram illustrating the BULK, ABSORPTION, FLOAT, and EQUALIZE stages of battery charging.

How to Apply Equalization Function:

  1. Enable battery equalization in LCD setting program 30.
  2. Set the equalization interval in program 35, or activate equalization immediately in program 36.

When to Equalize:

In the float stage, when the set equalization interval is reached or equalization is actively initiated, the controller will enter the Equalize stage.

5.6 Mains and Lithium Battery Activation Function

  1. After 90 seconds of mains power connection, the inverter connects to the mains and starts operation.
  2. If the inverter is in lithium battery mode (item 05 is LIP or LIL) and the battery is not connected, the mains activation function is automatically enabled upon mains connection.

6. Maintenance

6.1 Clearance and Maintenance for Anti-Dust Kit

The inverter comes with a pre-installed anti-dust kit to protect internal components and enhance reliability. The inverter automatically detects this kit and adjusts its internal thermal sensor.

Cleaning Steps:

  1. Loosen the screw in a counterclockwise direction on the top of the inverter.
  2. Remove the dustproof case and take out the air filter foam.
  3. Clean the air filter foam and dustproof case.
  4. After cleaning, re-assemble the dust-kit back into the inverter.

NOTICE: The anti-dust kit should be cleaned from dust every one month.

7. Troubleshooting

7.1 Fault Reference Code

The inverter displays specific fault codes to indicate issues. Refer to page 34 of the PDF manual for a comprehensive list of fault codes, their events, and corresponding icons.

Examples of Fault Codes:

  • 01: Fan is locked when inverter is off.
  • 02: Over temperature.
  • 03: Battery voltage is too high.
  • 04: Battery voltage is too low.
  • 05: Output short circuited or over temperature detected by internal converter components.
  • 51: Over current or surge.

Specific battery fault codes are also provided for lithium battery mode, such as high/low battery temperature or voltage.

7.2 Warning Indicator

The inverter uses warning indicators to alert users to potential issues. Refer to page 35 of the PDF manual for a comprehensive list of warning codes, their events, audible alarms, and icon flashing patterns.

Examples of Warning Codes:

  • 01: Fan is locked when inverter is on.
  • 03: Battery is over-charged.
  • 04: Low battery.
  • 07: Overload.
  • 6P: Battery is not connected.

7.3 General Troubleshooting Table

For common problems and their solutions, refer to the detailed troubleshooting table on page 40 of the PDF manual. This table outlines the problem, LCD/LED/Buzzer indications, possible causes, and recommended actions.

Common Issues and Solutions:

  • Unit shuts down automatically during startup: Battery voltage too low. Recharge or replace battery.
  • No response after power on: Battery voltage too low or internal fuse tripped. Contact repair center or recharge battery.
  • Mains exist but unit works in battery mode: Insufficient AC power quality or incorrect input voltage range setting. Check AC wires/generator or adjust settings.
  • Buzzer beeps continuously and red LED is on: Indicates various faults like over-charged battery, fan fault, or internal component failure. Refer to the table for specific actions.

8. Specifications

Detailed technical specifications for the Daxtromn Hybrid Solar Inverter are provided in the tables below. For full details, refer to pages 37-39 of the PDF manual.

8.1 Line Mode Specifications

Refer to page 37 of the PDF manual for a table detailing Input Voltage Waveform, Nominal Input Voltage, Low Loss Voltage, High Loss Voltage, Max AC Input Voltage, Nominal Input Frequency, Output Short Circuit Protection, Efficiency, and Transfer Time.

8.2 Inverter Mode Specifications

Refer to page 38 of the PDF manual for a table detailing Rated Output Power, Output Voltage Waveform, Output Voltage Regulation, Output Frequency, Peak Efficiency, Overload Protection, Surge Capacity, Nominal DC Input Voltage, Cold Start Voltage, Low DC Warning Voltage, Low DC Cut-off Voltage, High DC Recovery Voltage, High DC Cut-off Voltage, and No Load Power Consumption.

8.3 Two Load Output Power

Refer to page 38 of the PDF manual for a table detailing Full Load, Maximum Main Load, Second Load Range, Main Load Cut Off Voltage, and Main Load Return Voltage.

8.4 Charge Mode Specifications

Refer to page 39 of the PDF manual for a table detailing Charging Algorithm, AC Charging Current (Max), Bulk Charging Voltage (Flooded Battery, AGM/Gel Battery), Floating Charging Voltage, MPPT Solar Charging Mode (Max. PV Array Power, Nominal PV Voltage, PV Array MPPT Voltage Range, Max. PV Array Open Circuit Voltage, Max Charging Current).

8.5 Grid-Tie Operation

Refer to page 39 of the PDF manual for a table detailing Nominal Output Voltage, Feed-in Grid Voltage Range, Feed-in Grid Frequency Range, Nominal Output Current, Power Factor Range, and Maximum Conversion Efficiency (DC/AC).

8.6 General Specifications

Refer to page 39 of the PDF manual for a table detailing Safety Certification, Operating Temperature Range, Storage temperature, Humidity, Dimension (D*W*H), and Net Weight.

8.7 Approximate Back-up Time Table

Refer to page 41 of the PDF manual for tables providing approximate backup times based on load and battery configuration (24Vdc 100Ah/200Ah and 48Vdc 100Ah/200Ah). Note that backup time depends on battery quality, age, and type.

9. User Tips

  • Fan Behavior: The inverter's fans may not always run, even when the unit's internal temperature (e.g., LCD showing up to 50°C in USB/UPS mode) is elevated. This appears to be a common characteristic. Despite this, the device generally performs well in power switching and offers a good power reserve.
  • PV Input Voltage Requirement: When operating the solar inverter without an external battery, ensure the voltage from the solar panels is above 90VDC for normal operation. If an external battery is connected, a PV input voltage of 60VDC is sufficient.

10. Warranty and Support

This product comes with a 1-year warranty.

For further detailed instructions, specifications, and diagrams, you can download the complete user manual in PDF format:

Download User Manual (PDF)

If you encounter persistent issues after consulting the troubleshooting section, please contact your local dealer or service center for maintenance.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.