1. Important Safety Instructions

Please save these instructions.

This manual contains important safety, installation, and operating instructions for the charge controller. The following symbols are used throughout the manual to indicate potentially dangerous conditions or important safety information:

  • WARNING: Indicates a potentially dangerous condition. Use extreme caution when performing this task.
  • CAUTION: Indicates a critical procedure for safe and proper operation of the controller.
  • NOTE: Indicates a procedure or function that is important to the safe and proper operation of the controller.

1.1 General Safety Information

  • Read all instructions and cautions in the manual before beginning installation.
  • There are no serviceable parts for this controller. DO NOT disassemble or attempt to repair the controller.
  • DO NOT allow water to enter the controller.
  • Make sure all connections going into and from the controller are tight.
  • When making connections, ensure there are no flammable materials or gases near the installation area.
  • Connect the red wire to the positive pole and the black wire to the negative pole of the controller.

1.2 Charge Controller Safety

  • NEVER connect the solar panel array to the controller without a battery. The battery must be connected first.
  • Ensure input voltage does not exceed 190 VDC to prevent permanent damage. Use the Open Circuit Voltage (Voc) to ensure the voltage does not exceed this value when connecting panels together.

1.3 Battery Safety

  • Use only sealed lead-acid, flooded, gel, or lithium deep cycle batteries.
  • Explosive battery gases may be present while charging. Ensure adequate ventilation to release gases.
  • Be careful when working with large lead-acid batteries. Wear eye protection and have fresh water available in case of contact with battery acid.
  • Carefully read battery manuals before operation.
  • DO NOT let the positive (+) and negative (-) terminals of the battery touch each other.
  • Recycle the battery when it is replaced.
  • Over-charging and excessive gas precipitation can damage battery plates. Too high or too long an equalizing charge may cause damage. Review specific battery requirements.
  • Equalization is carried out only for non-sealed/vented/flooded/wet cell lead-acid batteries.
  • DO NOT equalize VRLA type AGM/Gel/Lithium cell batteries UNLESS permitted by the battery manufacturer.
  • Connect battery terminals to the charge controller BEFORE connecting the solar panel(s).
  • DO NOT connect any inverters or battery chargers into the load terminal of the charge controller.
  • Once equalization is active, it will not exit this stage unless there is adequate charging current from the solar panel. There should be NO load on the batteries during equalization charging.

2. Product Overview

The PowMr MPPT series solar charge controller utilizes advanced Maximum Power Point Tracking (MPPT) technology, designed for solar systems to maximize energy harvesting. It boasts a conversion efficiency of up to 97%.

2.1 Key Features

  • HHJ-60A, HHJ-80A, HHJ-100A models available.
  • 100% MPPT technology for optimal power tracking.
  • Built-in DSP controller for high performance.
  • Automatic voltage recognition for 12V/24V/36V/48V battery banks.
  • 3-stage charging algorithm (Bulk, Absorption, Float) optimizes battery performance and prolongs lifespan.
  • Multiple electronic protections: Overcharge, PV polarity reverse, output limited current, over-temperature.
  • Troubleshooting promotion function.
  • Suitable for various battery types: Sealed lead acid, vented, gel, NiCd, AGM, Lithium (LiFePO4), and user-defined.
  • Easy to mount design.
PowMr MPPT Solar Charge Controller with key features
PowMr MPPT Solar Charge Controller highlighting MPPT technology, battery support, multiple protection, and wide application.
Three models of PowMr MPPT Solar Charge Controllers
The 60A, 80A, and 100A models of the PowMr MPPT Solar Charge Controller.
Applications of PowMr MPPT Solar Charge Controller
Diverse applications including solar systems, off-grid systems, RV systems, and marine systems.

3. Setup and Installation

3.1 Dimensions

The physical dimensions of the controllers vary by model:

  • HHJ-60A: 214 x 115 x 50 mm (8.43 x 4.53 x 1.97 in)
  • HHJ-80A: 150 x 80 x 260 mm (approx.)
  • HHJ-100A: 170 x 80 x 280 mm (approx.)
Front view of HHJ-60A MPPT Solar Charge Controller
Front view of the HHJ-60A model.
Various views of HHJ-80A MPPT Solar Charge Controller
Various views of the HHJ-80A model.
Various views of HHJ-100A MPPT Solar Charge Controller
Various views of the HHJ-100A model.

3.2 Installation Steps

Follow these steps carefully for proper installation:

  1. Disconnect and Shade: Disconnect all circuit breakers and shade the solar panels to prevent power generation during installation.
  2. Connect Batteries: Connect the battery connection cable with the correct polarity to the middle pair of terminals on the solar charge controller (marked with the battery symbol). If the system is 12V, ensure your battery voltage is above 12V for the controller to boot up.
  3. Connect Solar Panel: Ensure the PV modules are protected from incident light. Connect the PV modules connection cable to the correct polarity of the left pair of terminals on the solar charge controller (marked with the PV modules symbol).
  4. Connect Loads: Connect the load cable to the correct polarity of the right pair of terminals on the solar charge controller (marked with the lamp symbol). To avoid voltage on the wires, connect the wire to the load before connecting to the controller.
  5. Final Work: Tighten all cables connected to the controller and remove all debris around the controller, leaving a space of approximately 5.91 inches (15 cm) for ventilation.

NOTE: You must strictly follow the wiring sequence of “connect the battery first, then the PV array, and finally the load.” It is strictly prohibited to connect the inverter directly to the load terminals of the controller; otherwise, permanent damage to the equipment may result.

Solar System Wiring Diagram
Typical wiring diagram for a solar system with MPPT controller, solar panels, battery, and inverter.

3.3 Air Circuit Breaker Installation

We strongly recommend connecting a fuse directly to the battery to protect against short circuits at the battery wiring. Solar PV modules generate current when exposed to light. Protect solar modules from incident light during installation. Never touch uninsulated cable ends, use only insulated tools, and ensure wire diameter is appropriate for the expected currents.

Air Circuit Breaker and Wires Requirement:

ModelsCopper Wires (Recommended)PV Breaker (Recommended)Battery Breaker (Recommended)Load Breaker (Recommended)
HHJ-60A6mm² x 2PCS100A-2P100A–
HHJ-80A10mm² / 8AWG x 2100A-2P100A-2P40A-2P
HHJ-100A10mm² / 8AWG x 2125A-2P125A-2P40A-3P

Installation Sequence with Air Circuit Breakers:

  1. Install air circuit breaker between controller and batteries. Turn off the circuit breaker, then connect batteries to controller with correct polarity.
  2. Install air circuit breaker between controller and PV modules. Turn off the circuit breaker, and ensure the PV polarity is correct, then connect wires between PV modules and controller.
  3. Turn on the air circuit breaker between controller and batteries.
  4. Turn on the air circuit breaker between controller and PV modules.
  5. The controller will enter self-test mode. Its LCD will display parameters if all is correct, and the RUN lamp (under the fan inside the casing) will flash every one second. If the controller is unresponsive, please review the manual or contact support.

4. Operation

4.1 LCD Display

The controller features a backlight LCD screen that displays various parameters and working modes. The main interface shows PV voltage/output power, battery voltage/charging current, working mode/temperature, and fault codes.

MPPT Solar Charge Controller LCD Display
The LCD screen displays battery charging, working mode, production, and other parameters, with fan cooling.

Main Interface Items:

  1. PV voltage / Output power
  2. Battery voltage / Charging current
  3. Working mode / Temperature
  4. Fault code

4.2 Working Modes

The controller operates in several working modes:

  • 3.0 Night Mode: No charging.
  • 4.0 MPPT Mode: Maximum Power Point Tracking.
  • 7.0 Absorption Mode: Battery charging stage.
  • 8.0 Floating Mode: Battery maintenance stage.

4.3 Batteries Charge Voltage Reference

The controller supports various battery types with specific charging voltage parameters:

Battery TypeFloat Charging Voltage (Default/12V)Absorption Charging Voltage (Default/12V)Under-voltage Protection (Default/12V)
SEL (Sealed Lead-Acid)13.8V14.4V11.0V
GEL (Gel Lead-Acid)13.8V14.2V11.0V
FLd (Flooded Lead-Acid)13.8V14.6V11.0V
L04 (4-series LiFePO4)13.8V14.5V11.2V
L08 (8-series LiFePO4)27.6V29.0V22.4V
L15 (15-series LiFePO4)51.8V54.4V42.0V
L16 (16-series LiFePO4)55.2V58.0V44.8V
USE (User-defined)Defined by users

NOTICE: When selecting SEL, GEL, and FLd battery types, the controller automatically detects the system voltage.

4.4 Manual Setting

The controller will work fine under default settings, except for lithium batteries, which may require manual adjustment.

CAUTION: All steps for manual setting must be carried out when the PV modules are disconnected from the controller.

  1. Step 1: D00 (Load Working Time)
    Press the PRG button until D00 is displayed. This sets the load working time (default is 24-hour). Press ENT until numbers flash, then use UP/DOWN to set the desired time. Long-press ENT to confirm. The output voltage is the same as the battery. This load setting is for small DC loads less than 5A. If no load, leave it.
  2. Step 2: D01 (Float Charging Voltage)
    Press UP, LCD shows 13.8V (default float charging voltage for 12V). Press ENT until numbers flash, then use UP/DOWN to set the desired voltage. Long-press ENT to confirm.
    CAUTION: This value is for one 12V battery. If multiple batteries are in series, the controller will automatically multiply this value proportionally. The LCD will only display the voltage for one battery (e.g., for 4x12V, setting 14.1V will result in 4x14.1V charge, but the LCD shows 14.1V).
  3. Step 3: D02 (Absorption Charging Voltage)
    Continue to press UP, LCD shows 14.5V (default absorption charging voltage for 12V). Press ENT until numbers flash, then use UP/DOWN to set the desired voltage. Long-press ENT to confirm.
    CAUTION: This value is for one 12V battery. If multiple batteries are in series, the controller will automatically multiply this value proportionally. The LCD will only display the voltage for one battery.
  4. Step 4: D03 (Battery Discharge Protection)
    Continue to press UP, LCD shows 10.0V (default discharge protection for 12V). Press ENT until numbers flash, then use UP/DOWN to set the desired voltage. Long-press ENT to confirm. This means the output power from OU+ and OU- will be cut off if the 12V battery voltage drops below this value.
  5. Step 5: D04 (Battery Voltage Calibration)
    Continue to press UP, LCD shows C12.2. This setting allows you to calibrate the battery voltage to ensure the controller's reading matches the actual battery voltage.
  6. Step 6: D05 (Battery Type Setting)
    Continue to press UP, LCD shows the battery type setting program. The default option is USE. Select from the available battery types (SEL, GEL, FLd, L04, L08, L15, L16) or choose USE for user-defined settings.
    CAUTION: When selecting SEL, GEL, and FLd battery types, the controller automatically detects the system voltage.
  7. Step 7: D06 (User-defined System Voltage)
    If you selected the USE option in D05, you will need to manually configure the system voltage in the D06 setup program. The configuration range is 12V/24V/36V/48V.

To exit the setting menu: Press ESC.

Reminder: After setting all steps, please disconnect the battery. Reconnect the controller to verify successful settings. Once confirmed, connect the PV modules to the controller.

5. Maintenance

The PowMr MPPT Solar Charge Controller is designed for reliable operation with minimal maintenance. To ensure optimal performance and longevity:

  • Regular Inspection: Periodically check all wiring connections to ensure they are tight and free from corrosion.
  • Ventilation: Ensure the area around the controller is clear of debris and has adequate airflow to allow the fan to operate effectively, especially in hot environments.
  • Cleaning: Keep the controller's exterior clean and free of dust. Do not use harsh chemicals or allow liquids to enter the device.
  • No User Serviceable Parts: The controller contains no user-serviceable parts. Do not attempt to disassemble or repair the unit, as this will void the warranty and may cause damage or injury.

6. Troubleshooting and Protections

6.1 Troubleshooting Guide

If you encounter issues, refer to the following table:

CodeDescriptionHow to Solve
18Input PV voltage is lowIncrease the PV voltage
60Over-temperature protectionFan will work and temperature reduction automatically
63Battery voltage is highBattery high voltage protection and wait for recovery
65Battery voltage is lowBattery over-discharge and wait for recovery
71Input PV voltage is highDecrease the PV voltage
73Over-charging currentDecrease the PV power

6.2 Built-in Protections

The controller incorporates several protection mechanisms to ensure safe and reliable operation:

  1. PV Over Current: The controller limits charging power to its rated capacity. An oversized PV array will not operate at maximum power point but will not damage the controller.
  2. PV Short Circuit: If a PV short circuit occurs, the controller stops charging. Remove the short circuit to resume normal operation.
  3. PV Reverse Polarity: Full protection against PV reverse polarity ensures no damage to the controller. Correct the connection to start normal operation.
  4. Battery Over Voltage: If the battery voltage exceeds 15.5V (for 12V systems, proportionally higher for 24V/36V/48V), the controller will stop charging to protect the battery from overcharging.
  5. Battery Over Discharge: When battery voltage drops to the low voltage disconnect point, the controller stops discharging to protect the battery from over-discharging.
  6. Load Over Current Protection: If the load current exceeds 1.25 times the maximum rated load current, the controller will disconnect the load.
  7. Load Short Circuit Protection: If a load short circuit occurs, the load short circuit protection will activate automatically.
  8. Over Temperature Protection: A built-in smart thermostatic fan activates at 45°C (113°F) and above for forced cooling. The fan turns off below 40°C (104°F).

7. Technical Specifications

ParameterHHJ-60AHHJ-80AHHJ-100A
Charging Mode3-stage (Bulk/Absorption/Float)
Solar InputRated Charging Current60A80A100A
Max. PV Input Power (12V)720W960W1200W
Max. PV Input Power (24V)1440W1920W2400W
Max. PV Input Power (36V)2100W2880W3600W
Max. PV Input Power (48V)2800W3840W4800W
Input Specification DCPV Input Voltage Range (12V)20V ~ 80V
PV Input Voltage Range (24V)37V ~ 105V
PV Input Voltage Range (36V)50V ~ 160V50V ~ 150V
PV Input Voltage Range (48V)72V ~ 160V72V ~ 150V
Battery Voltage Auto Recognition12V SystemDC9V ~ DC15V
24V SystemDC18V ~ DC29V
36V SystemDC30V ~ DC39V
48V SystemDC40V ~ DC60V
Overcharging Protection Voltage60V
Limited Current Protection61A
Max Efficiency≥98.1%
PV Utilization≥99%
Protection Function
Temperature Protection75°C / 167°F
Fan-on Temperature>45°C / 113°F
Fan-off Temperature<40°C / 104°F
Physical Properties
Size (L x W x H)214x115x50mm / 8.43x4.53x1.97in~150x80x260mm~170x80x280mm
Net Weight1.1 kg / 2.43 lb2.1 kg2.7 kg
Gross Weight1.2 kg / 2.65 lb~2.2 kg~2.8 kg
Electromagnetic CompatibilityEN61000, EN55022, EN55024
Enclosure RatingIP21
Environmental Temperature-20°C ~ +55°C (-4°F ~ +131°F)
Storage Temperature-40°C ~ +75°C (-40°F ~ +167°F)

8. Warranty and Support

8.1 Warranty Regulations

  1. 30-Day Replacement: Within 30 days from the date of purchase, a faulty controller will be replaced free of charge under normal use (by authorized technical personnel).
  2. 2-Year Repair: Within 2 years from the date of purchase, a faulty controller will be repaired free of charge.

Note: Disassembling the unit privately voids the warranty.

8.2 Contact Information

For any questions or support, please contact us:

  • Tel/Fax: +86 755-28219903
  • Email: support@powmr.com
  • Web: www.powmr.com
  • Address: Henggang Street, Longgang District, Shenzhen, Guangdong, China

User Manual (PDF):

A detailed user manual in PDF format is available for download. This document provides comprehensive guides and specifications. View User Manual (PDF)

9. Content Included

The product package includes:

  • 1x MPPT Solar Charge Controller
  • 4x Corner connections
  • 4x Screws for controller casing
  • 1x English manual

10. User Tips

  • Initial Check: Upon receiving the product, verify the build quality. While robust, it's good practice to inspect for any transit damage before installation.
  • Wiring Sequence: Always adhere strictly to the wiring sequence: battery first, then PV array, then load. This is crucial for preventing damage.
  • Polarity: Double-check all positive and negative polarities during connection to avoid issues.
  • Documentation: Keep the user manual handy for reference, especially during initial setup and if troubleshooting is needed.

© 2024 PowMr. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.