XikeStor SKS3200-5E1X

Contents

XikeStor SKS3200-5E1X Smart Managed Switch

User Manual

1. Introduction

The XikeStor SKS3200-5E1X is a high-performance, easy-to-manage Ethernet switch designed for modern networking needs. It features versatile 2.5G and 10G hybrid connectivity, comprehensive web management capabilities, and a durable, fanless design for quiet and reliable operation.

This switch is ideal for various applications, including large data centers, cloud computing platforms, small and medium-sized enterprise networks, home offices, and campus environments, providing high-speed and stable data transmission.

XikeStor SKS3200-5E1X Smart Managed Switch with ports labeled
Figure 1: XikeStor SKS3200-5E1X Smart Managed Switch Overview

This image shows the front view of the XikeStor SKS3200-5E1X switch, highlighting its 5x 2.5G RJ45 ports and 1x 10G SFP+ port, along with the DC 12V power input and PWR indicator. Key features like Web Managed, Fanless Design, Durable Metal Casing, and Wall-Mountable are also indicated.

2. Key Features

  • Versatile 2.5G & 10G Hybrid Connectivity: Equipped with 5× 2.5GbE RJ45 ports (100M/1G/2.5G auto-sensing) and 1× 10G SFP+ uplink port. The SFP+ slot supports 1G/2.5G/10G optical modules, DAC, and AOC cables.
  • High Switching Capacity: 45Gbps backplane bandwidth ensures zero bottlenecks for high-demand applications.
  • Comprehensive Web Management: Intuitive Web UI for professional network control, supporting Layer 2 functions including VLAN (up to 32 IDs), QoS data prioritization, Link Aggregation (Static & LACP), IGMP Snooping, Loop Prevention, and Bandwidth Control.
  • Stable High-Speed & Non-Blocking Transmission: All ports support full line-rate, non-blocking switching with Auto MDI/MDIX, reducing forwarding latency and preventing packet loss.
  • Silent Fanless Design & Durable Aluminum Casing: Premium aluminum alloy casing with front and rear heat vents for efficient, noiseless cooling.
  • Enhanced Stability: Supports 6KV lightning protection and 8KV ESD shielding for durability in various environments.

3. Setup Guide

3.1 Package Contents

Before installation, please verify the contents of your package:

  • XikeStor SKS3200-5E1X Switch x1
  • User manual x1
  • Certificate x1
  • Power adapter x1
  • Rubber feet x4
  • Grounding screw x1

3.2 Physical Installation

The SKS3200-5E1X switch is designed for both desktop use and wall-mounting.

  1. Desktop Placement: Attach the included rubber feet to the bottom of the switch to prevent slipping and protect surfaces. Place the switch on a stable, flat surface.
  2. Wall-Mounting: Use the provided grounding screw and appropriate wall anchors (not included) to securely mount the switch to a wall. Ensure adequate space around the switch for ventilation and cable management.

3.3 Power Connection

  1. Connect the included power adapter to the DC 12V port on the switch.
  2. Plug the power adapter into a standard electrical outlet.
  3. The PWR LED indicator on the front panel will illuminate when the switch receives power.

3.4 Network Connections

  1. RJ45 Ports (1-5): Connect your network devices (e.g., PCs, NAS, WiFi APs, routers) to the 2.5G RJ45 ports using Cat5e or higher Ethernet cables. These ports support 100M/1G/2.5G auto-sensing.
  2. SFP+ Port (6): For high-speed uplink or fiber connections, insert a compatible 1G/2.5G/10G SFP+ optical module (not included) into the SFP+ port. Then, connect a fiber optic cable or DAC/AOC cable to the module.
Multi-device network connectivity diagram
Figure 2: Multi-Device Network Connectivity

This diagram illustrates how the XikeStor SKS3200-5E1X switch connects various network devices such as PCs, printers, NAS, and IPTV, providing high-speed seamless connectivity.

3.5 Initial Web Management Access

To configure your switch via the web interface:

  1. Ensure your computer is connected to one of the switch's RJ45 ports.
  2. Set your computer's network IP address to a static IP within the range 192.168.10.X (where X is 2-254, excluding 12). For example, 192.168.10.100.
  3. Open a web browser and navigate to the default IP address: 192.168.10.12.
  4. Enter the default credentials, which are typically found on a label on the product itself (e.g., Username: admin, Password: admin).
  5. Upon successful login, you will access the switch's web management interface.
Web management interface screenshot
Figure 3: Web Management Interface

This image displays a screenshot of the switch's web management interface, showing the default IP address (192.168.10.12), username (admin), and password (admin). It also highlights various configuration options like Switch Monitor, VLAN Configuration, QoS Configuration, and System Manage.

4. Operating the Switch

4.1 LED Indicators

The front panel LEDs provide real-time status information for the switch:

IndicatorStatusDescription
PWROnPower is on
PWROffNo power
SYSOnSystem normal
SYSBlinkingSystem booting
Ports 1-5 (RJ45)Green On2.5G link normal
Ports 1-5 (RJ45)Yellow On10/100/1000M link normal
Ports 1-5 (RJ45)OffNo link
Ports 1-5 (RJ45)BlinkingData transfer
Port 6 (SFP+)Green On10G/2.5G link normal
Port 6 (SFP+)Yellow On1G link normal
Port 6 (SFP+)OffNo link
Port 6 (SFP+)BlinkingData transfer
Visual Status Indicators and Reset Button
Figure 4: Visual Status Indicators and Reset Button

This image details the visual status indicators for PWR, RJ45 ports (2.5Gbps, 100M/1000M), and SFP+ port (Device is Connected). It also shows the location of the hidden reset button, designed to prevent accidental use.

4.2 Web Management Functions

The web management interface allows for advanced configuration and monitoring of your network. Key Layer 2 features include:

  • Port Configuration: Manage individual port settings.
  • Port Speed Configuration: Adjust speed and duplex settings for each port.
  • VLAN Configuration: Create and manage Virtual Local Area Networks (VLANs) for network segmentation (supports up to 31 active VLANs, range 1-4094).
  • QoS Configuration: Prioritize network traffic (Quality of Service) with up to 8 queues per port, supporting SP and WRR scheduling.
  • Link Aggregation (LACP): Combine multiple physical links into a single logical link for increased bandwidth and redundancy (supports up to 2 aggregation groups with up to 4 members per group).
  • IGMP Snooping: Optimize multicast traffic delivery.
  • Spanning Tree Protocol (STP/RSTP): Prevent network loops.
  • MAC Address Table: View and manage MAC addresses (4K entries, dynamic and static).
  • Storm Control: Suppress broadcast, unknown multicast, and unknown unicast storms.
  • Port Mirroring: Monitor network traffic by sending a copy of packets from one port to another.
  • Port Security: Limit MAC addresses on a port.
  • Port Isolation: Isolate ports to prevent direct communication between them.
  • Port Rate Limiting: Control bandwidth usage on individual ports.
  • Loop Detection: Detect and prevent network loops.
  • Jumbo Frame Support: Up to 16356 bytes.
  • EEE (Energy Efficient Ethernet): Reduce power consumption during low link utilization.

5. Maintenance

5.1 General Care

  • Keep the switch in a clean, dry environment.
  • The fanless design minimizes dust accumulation, but occasional cleaning of the exterior with a soft, dry cloth is recommended.
  • Ensure the front and rear heat vents are not obstructed to maintain efficient heat dissipation.

5.2 Firmware Management

The switch supports firmware upgrades. Refer to the manufacturer's website for the latest firmware versions and instructions. The web management interface provides options for firmware upload and backup.

5.3 Reset Button

A hidden reset button is located on the device to prevent accidental use. To restore factory settings, press and hold the reset button for 6 seconds. This will revert all configurations to their default state.

6. Troubleshooting

6.1 No Power

  • Check if the power adapter is securely connected to the switch and the electrical outlet.
  • Verify that the electrical outlet is functioning correctly.
  • Ensure the PWR LED is illuminated. If not, try a different power adapter or outlet.
  • Check the Ethernet cable connection between the switch port and the connected device.
  • Ensure the cable is not damaged and is properly seated.
  • Verify that the connected device is powered on and functioning correctly.
  • Check the corresponding RJ45 or SFP+ LED indicator. If it's off, there's no link.

6.3 Cannot Access Web Management Interface

  • Ensure your computer's IP address is configured correctly within the same subnet as the switch (e.g., 192.168.10.X).
  • Verify that you are using the correct default IP address (192.168.10.12) and credentials (admin/admin).
  • Try clearing your browser's cache or using a different browser.
  • If the issue persists, perform a factory reset (see Section 5.3) and try again.

6.4 Network Performance Issues

  • Check for high traffic on specific ports using the switch monitor in the web interface.
  • Ensure proper cable types are used for desired speeds (e.g., Cat5e for 2.5G, Cat6a for 10G).
  • Verify that QoS settings are configured correctly if traffic prioritization is desired.
  • Check for network loops; Spanning Tree Protocol should prevent these, but misconfigurations can occur.

7. Technical Specifications

ParameterValue
Model NumberSKS3200-5E1X
Switch TypeEthernet, Smart Managed
I/O Interfaces5 x 2.5G RJ45 Ports, 1 x 10G SFP+ Port
Switching Capacity45Gbps
Packet Forwarding Rate33.48Mpps
MAC Address Table4K
Packet Forwarding Cache12M
Jumbo Frame10Kbytes (up to 16356 bytes)
VLAN SupportRange 1-4094, up to 31 active VLANs
Communication ModeFull-Duplex & Half-Duplex
Network ProtocolsIEEE 802.3, 802.3u, 802.3ab, 802.3bz, 802.3ae, 802.3x, 802.1D, 802.1w, 802.1Q
Power SupplyDC 12V1A
Power Consumption12W
Dimensions (LxWxH)110 x 94 x 30.7 mm
Operating Temperature-10°C to 50°C
Storage Temperature-40°C to 70°C
Operating Humidity10%~90%, non-condensing
Storage Humidity5%-95%, non-condensing
CertificationsCE, FCC, RoHS, PSE, UKCA

8. User Tips

  • Save Configurations: After making any changes in the web management interface, always navigate to the 'System Manage' section and click the 'Save' button. This ensures your settings are retained after a power cycle or firmware update.
  • Cable Quality: For optimal performance, especially at 2.5G and 10G speeds, use high-quality Ethernet cables (Cat5e or better for 2.5G, Cat6a or better for 10G).
  • SFP+ Module Compatibility: When using the SFP+ port, ensure your optical modules or DAC/AOC cables are compatible with 1G, 2.5G, or 10G standards as required.

9. Warranty and Support

For warranty information, technical support, and the latest firmware updates, please visit the official XikeStor website or contact your vendor. The product is certified with CE, FCC, RoHS, PSE, and UKCA standards, ensuring compliance with various regulatory requirements.

A user manual in PDF format is available for download from the seller's product page: View User Manual (PDF)

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.