1. Introduction
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Sumry 4KW Hybrid Solar Inverter. Please read this manual thoroughly before installation and keep it for future reference.

Figure 1: Front view of the Sumry Hybrid Solar Inverter, showing the large LCD display and control buttons.
2. Safety Precautions
- Read all instructions and cautionary markings on the unit and in this manual before operating.
- Installation must be performed by qualified personnel.
- Do not disassemble the inverter. There are no user-serviceable parts inside. Refer servicing to qualified service personnel.
- Ensure all wiring is correctly sized and properly connected to prevent overheating and electrical hazards.
- Always disconnect all power sources (PV, battery, AC input) before performing any maintenance or wiring.
- This inverter is designed for indoor use only. Do not expose it to rain, snow, or any liquids.
- Ensure adequate ventilation around the inverter to prevent overheating.
3. Setup and Installation
3.1 Unpacking
Upon unpacking, ensure all components are present and undamaged. If any damage is found, contact your supplier immediately.
3.2 Mounting
Mount the inverter vertically on a sturdy wall or surface. Ensure there is sufficient clearance around the unit for proper airflow and cooling. Avoid mounting in direct sunlight or near heat sources.
3.3 Wiring Connections
All wiring must comply with local and national electrical codes. Use appropriate wire gauges for all connections.

Figure 2: Detailed wiring diagram for the hybrid solar inverter, showing connections for solar panels, battery, AC input (generator/mains), and AC output (loads). Includes key technical specifications.
3.3.1 Circuit Breaker Recommendations
Before installing and using the solar inverter, it is recommended to install circuit breakers in the following positions:
- 200A 2-pole breaker between the battery pack and the inverter's battery input terminals.
- 20A 2-pole breaker between the solar panels and the inverter's PV input terminals.
- 63A 2-pole breaker between the inverter's AC power input terminals.
- 40A 2-pole breaker between inverter's output terminals and load.
3.3.2 Connection Order
- Connect the battery cables to the inverter's battery terminals (ensure correct polarity).
- Connect the PV array cables to the inverter's PV input terminals (ensure correct polarity).
- Connect the AC input (Grid/Generator) to the inverter's AC input terminals.
- Connect your AC loads to the inverter's AC output terminals.
- Ensure all connections are secure before powering on.
3.3.3 Important Notes
- This power inverter does NOT support parallel operation.
- This solar inverter is not waterproof. Please install it indoor with good air ventilation or under shelter to protect it from rains.
- The maximum solar input voltage that this 4000 watt inverter can accept is 350VDC. Considering that sometimes the sun is particularly good, the solar input voltage can exceed 350VDC. So it is recommended that the maximum open circuit voltage of the connected solar panel is 280VDC. PV Start-up voltage is recommended to be >90VDC for initial charging the battery.
4. Operating Instructions
4.1 Front Panel Overview

Figure 3: Multi-panel image detailing the inverter's features: LCD display, indicators, function buttons, rear communication ports, cooling fans, and MPPT controller.
4.1.1 LCD Display
The 6.25-inch LCD display provides real-time information on the inverter's status, including:
- Input Power (PV/AC)
- Battery Voltage/Charge Status
- Output Load Percentage/Power
- System Status and Warnings
4.1.2 Indicators
- AC/INV: Indicates AC input presence or inverter operation.
- CHG: Indicates battery charging status.
- FAULT: Illuminates when a system fault occurs.
4.1.3 Function Touch Buttons
- ESC: Exit current menu or return to previous screen.
- UP: Navigate up through menu options or increase values.
- DOWN: Navigate down through menu options or decrease values.
- ENTER: Confirm selection or enter a menu.
4.2 Power On/Off
- Power On: Ensure all connections are secure. Turn on the battery breaker, then the PV breaker, then the AC input breaker. Finally, press the power on/off button on the inverter.
- Power Off: Press the power on/off button to shut down the inverter. Then, turn off the AC input breaker, followed by the PV breaker, and finally the battery breaker.
5. Maintenance
- Regular Cleaning: Keep the inverter clean and free from dust. Use a dry cloth to wipe the exterior.
- Ventilation Check: Periodically check that the cooling vents are not obstructed. Ensure the three cooling fans are operating correctly.
- Connection Check: Annually, inspect all electrical connections for tightness and signs of corrosion.
- Environment: Ensure the installation environment remains within specified temperature and humidity ranges.
6. Troubleshooting
If the FAULT indicator illuminates or the inverter is not operating as expected, perform the following basic checks:
- Check Connections: Verify all battery, PV, AC input, and AC output connections are secure and correctly wired.
- Check Breakers: Ensure all circuit breakers are in the ON position and have not tripped.
- Battery Voltage: Confirm the battery voltage is within the acceptable operating range.
- PV Input: Check if the solar panels are producing sufficient voltage and current.
- Overload: Reduce the connected load if an overload warning is displayed.
- Restart: Try powering off the inverter completely (following the power-off procedure) and then restarting it.
If the issue persists after these checks, contact your supplier for further assistance.
7. Specifications
| Feature | Specification |
|---|---|
| Model Number | HGX-4KW-24V |
| Rated Power | 4000W |
| AC Input Voltage | 110V/120VAC |
| AC Input Frequency | 50Hz/60Hz |
| Output Voltage | 120Vac±5% |
| Output Current | 33A |
| Output Wave Form | Pure Sine Wave |
| Inverter Efficiency | 96% |
| Max PV Array Power | 5600W |
| MPPT Voltage Range | 55-350VDC |
| Max Charging Current | 140A (MPPT) / 110A (Battery) |
| Battery Type | 24V Lithium/Lead acid (GEL, LI, AGM, USER, FLD compatible) |
| Battery-less Operation | Supported |
| Material | Aluminum alloy |
| Operating Temperature | -10℃ to 50℃ |
| Communication Ports | RS485/RS232 |
| Cooling | Three Cooling Fans |
| Certifications | CE |
8. Warranty and Support
8.1 Warranty
This Sumry Hybrid Solar Inverter comes with a 1-year warranty from the date of purchase. The warranty covers defects in materials and workmanship under normal use. It does not cover damage caused by improper installation, misuse, accidents, or unauthorized modifications.
8.2 Technical Support
For technical assistance, troubleshooting beyond the scope of this manual, or warranty claims, please contact your original point of purchase or the manufacturer's authorized service center. Please have your product model number and purchase date available when contacting support.