1. Introduction
The XikeStor SKS3200-5E1X is a 6-port 2.5G managed Ethernet switch designed for high-speed and stable data transmission. It features 5x 2.5GbE RJ45 ports with auto-sensing capabilities (100M/1G/2.5G) and 1x 10G SFP+ uplink port, which supports 1G/2.5G/10G optical modules, DAC, and AOC cables. With a 45Gbps backplane bandwidth, this switch ensures efficient network performance for demanding applications like NAS, WiFi 6/7 APs, and 4K video streaming.
This switch offers comprehensive web management functions, including VLAN division, port aggregation, port mirroring, QoS data prioritization, and more, making it suitable for various complex network environments in home, hotel, campus, and small to medium-sized enterprise projects.
2. Package Contents
Please check the package contents carefully. If any item is missing or damaged, contact your vendor.
- XikeStor SKS3200-5E1X Switch x1
- User Manual x1
- Certificate x1
- Power Adapter x1
- Rubber Feet x4
- Grounding Screw x1
3. Product Overview
3.1 Physical Layout
The switch features a full aluminum alloy casing for durability and efficient heat dissipation. It supports both desktop and wall-mounted installation.
3.2 LED Indicators
The front panel includes LED indicators for monitoring the switch's status and for troubleshooting.
| Indicator | Status | Description |
|---|---|---|
| PWR | On | Power is on |
| Off | No power | |
| SYS | On | System normal |
| Blinking | System booting | |
| RJ45 Ports (1-5) | Green on | 2.5G link normal |
| Yellow on | 10/100/1000M link normal | |
| Off | No link | |
| Blinking | Data transfer | |
| SFP+ Port (6) | Green on | 10G/2.5G link normal |
| Yellow on | 1G link normal | |
| Off | No link | |
| Blinking | Data transfer |
4. Setup
4.1 Physical Installation
- Placement: Place the switch on a stable, flat surface or mount it to a wall using appropriate hardware (not included). Ensure adequate ventilation around the device.
- Power Connection: Connect the provided power adapter to the DC 12V port on the switch and then plug it into a power outlet. The PWR LED should illuminate.
- Network Connections:
- Connect your network devices (PCs, NAS, WiFi APs, etc.) to the RJ45 ports (1-5) using Cat5e or higher Ethernet cables.
- For 10G uplink, insert a compatible SFP+ module (1G/2.5G/10G) into the SFP+ port (6) and connect it to your fiber network or another 10G device using a DAC/AOC cable or fiber optic cable.
4.2 Initial Network Configuration for Web Management
To access the switch's web management interface for configuration:
- Connect a computer directly to one of the switch's RJ45 ports.
- Set your computer's network adapter IP address to a static IP within the
192.168.10.Xrange (e.g.,192.168.10.100), ensuringXis between 2 and 254 and not 12. Set the subnet mask to255.255.255.0. - Open a web browser and navigate to the default IP address of the switch:
192.168.10.12. - Enter the default username and password, which are typically found on a label on the product itself. (Default: Username:
admin, Password:admin). - You should now have access to the web management interface.
5. Operating the Switch (Web Management)
The XikeStor SKS3200-5E1X is a smart managed switch, offering an intuitive web user interface (UI) for advanced network control. This allows you to configure various Layer 2 functions to optimize your network.
5.1 Key Management Functions
- VLAN Configuration: Create and manage Virtual Local Area Networks (VLANs) to segment your network for improved security and performance. The switch supports VLAN IDs from 1-4094, with up to 31 active VLANs.
- QoS (Quality of Service): Prioritize network traffic to ensure critical applications (e.g., VoIP, video conferencing) receive sufficient bandwidth. Supports SP (Strict Priority) and WRR (Weighted Round Robin) scheduling with up to 8 queues per port.
- Link Aggregation (LACP): Combine multiple physical links into a single logical link to increase bandwidth and provide redundancy. Supports static aggregation and LACP, with a maximum of 2 aggregation groups and up to 4 members per group.
- Port Mirroring: Monitor network traffic by sending a copy of packets from one port to another for analysis.
- Port Security: Limit access to ports based on MAC addresses to prevent unauthorized devices from connecting.
- Storm Control: Prevent network disruptions caused by excessive broadcast, multicast, or unknown unicast traffic.
- Jumbo Frame: Support for jumbo frames up to 16356 bytes to improve efficiency for large data transfers.
- Firmware Management: The web interface allows for firmware upgrades to enhance features and improve stability.
Important: After making any configuration changes, always click the "Save" button under the "System Manage" section to ensure your settings are retained after a power cycle or firmware update.
6. Maintenance
6.1 General Care
- Keep the switch in a cool, dry environment, away from direct sunlight and heat sources.
- Ensure proper ventilation. The fanless design relies on natural airflow through its front and rear heat vents.
- Clean the device periodically with a soft, dry cloth. Do not use liquid or aerosol cleaners.
- Avoid placing heavy objects on top of the switch.
6.2 Firmware Updates
Periodically check the XikeStor official website for new firmware versions. Firmware updates can provide performance improvements, bug fixes, and new features. Refer to the firmware upgrade section within the web management interface for detailed instructions.
7. Troubleshooting
7.1 Common Issues
- No Power: Ensure the power adapter is securely connected to the switch and a working power outlet. Check the PWR LED.
- No Link: Verify that Ethernet cables are properly connected to both the switch and the network device. Check the corresponding port LED indicators. Ensure the connected device is powered on and functioning correctly.
- Slow Network Speed: Check cable types (Cat5e for 2.5G, Cat6a for 10G). Ensure network adapter drivers are up to date. Verify duplex settings in the web management interface.
- Cannot Access Web UI: Double-check your computer's IP address settings to ensure it's in the same subnet as the switch (e.g., 192.168.10.X). Verify the switch's IP address (default is 192.168.10.12). Clear browser cache or try a different browser.
7.2 Factory Reset
If you encounter persistent issues or forget your login credentials, you can restore the switch to its factory default settings:
- Locate the Reset button on the switch (refer to Figure 3).
- With the switch powered on, use a paperclip or a similar pointed object to press and hold the Reset button for approximately 6 seconds.
- Release the button. The switch will reboot with factory default settings.
Warning: Performing a factory reset will erase all custom configurations and restore the switch to its original settings.
8. Technical Specifications
| Feature | Description |
|---|---|
| Model | SKS3200-5E1X |
| Ports | 5 x 100/1000/2500M RJ45, 1 x 10G SFP+ |
| Chipset | RTL8372N |
| Backplane Bandwidth | 45Gbps |
| Packet Forwarding Rate | 44.64Mpps |
| Packet Buffer | 8Mbit |
| MAC Address Table | 4K |
| Jumbo Frame | Up to 16356 bytes |
| Forwarding Mode | Store and Forward |
| VLAN | Range 1-4094, up to 31 active VLANs (Access/Trunk/Hybrid) |
| Network Protocols | IEEE 802.3, 802.3u, 802.3ab, 802.3bz, 802.3ae, 802.3x |
| Industry Standards | EMS: EN61000-4-2 (ESD), EN61000-4-5 (Surge) |
| Cabling Requirements | 10Base-T: Cat3/4/5; 100Base-TX/1000Base-TX: Cat5; 2.5GBase-T: Cat5e; 5GBase-T: Cat6; 10GBase-T: Cat6a (all UTP/STP ≤100m) |
| Fiber Media | 1000BASE-SX/LX, 2500BASE-X, 10GBASE-SR/LR (various MMF/SMF types) |
| Certifications | CE, FCC, RoHS, PSE, UKCA |
| Dimensions (LxWxH) | 110mm x 94mm x 30.7mm |
| Operating Voltage | Adapter: AC 100-240V; Switch: DC 12V1A |
| Power Consumption | 12W |
| Operating Temperature | -10°C to 50°C |
| Storage Temperature | -40°C to 70°C |
| Operating Humidity | 10%-90%, non-condensing |
| Storage Humidity | 5%-95%, non-condensing |
9. User Tips
- Always Save Configurations: Remember to click the “Save” button under the “System Manage” section in the web interface after making any changes. This ensures your settings are preserved even after a power cycle or firmware upgrade.
- Optimal Cable Usage: For best performance, especially at 2.5G and 10G speeds, use high-quality Ethernet cables (Cat5e for 2.5G, Cat6a for 10G) that meet or exceed the specified standards.
- Fanless Operation: The fanless design ensures quiet operation. To maintain optimal performance and heat dissipation, ensure the switch is placed in an area with good airflow and its vents are not obstructed.
10. Warranty and Support
XikeStor products are designed for reliability and performance. For warranty information, technical support, or service inquiries, please refer to the official XikeStor website or contact your local distributor. Keep your purchase receipt for warranty validation.