1. Introduction and Overview
The ZIBOO Digital Clamp Meter (Models 376 & 393) is a new technology, hand-held, non-slip ergonomic device designed for professional electricians and industrial use. It offers multi-functionality, high precision, high performance, anti-drop capabilities, safety, and stability. This meter accurately measures AC/DC current, AC/DC voltage, provides high voltage alarms, frequency, continuity, diode, resistance, capacitance, NCV (Non-Contact Voltage) detection, and Live wire detection. It also features misoperation circuit protection, making it an essential tool for electrical maintenance, repair, factory production, and distribution control system maintenance.
The ZIBOO 393 model is specifically designed for high voltage applications, capable of measuring DC voltage up to 1700V and AC voltage up to 1000V, making it suitable for photovoltaic (PV) solar devices, high-voltage automotive systems (EV), HVAC maintenance, and industrial troubleshooting.

Figure 1: ZIBOO 393 Digital Clamp Meter

Figure 2: ZIBOO 376 Digital Clamp Meter
2. Safety Information
Please read all safety information carefully before use to prevent electric shock, injury, or damage to the meter.
- This product strictly follows the safety standard of European Electrotechnical Commission EN61010-1 and the technical design standard of China GB T 13978.
- Please read the "safety information" before using the instrument and operate in strict accordance with the provisions.
- Please measure according to the range specified by the product and do not rotate the gear during the measurement process to avoid damage caused by misoperation of the instrument.
- To avoid possible electrical shock, please do not touch the live conductor exceeding 30V AC and 60V DC during measurement.
- When measuring AC and DC over 599V, there will be high voltage lightning symbol display and buzzer beeps; please pay attention to the safety of measurement.
- To avoid danger, do not use in inflammable and explosive environments.
- To avoid measurement error, when the meter displays the battery symbol (🔋), the battery should be replaced immediately.
- Please check the test pen and wire before measuring whether there is damage and leakage; if found, do not use.
- Please comply with national regulations and measurement safety standards. Wear insulating gloves or flame retardant products when measuring hazardous voltage.
International Electrical Symbols
- ⚠ Be careful! Indicates a dangerous operation
- ⚡ High current! Indicates a high voltage hazard warning
- CE European Union unified directive, European CE certification
- ⊥ Grounding
- □ Double insulation or enhanced insulation protection
- ♻ Compliance with WEEE recycling instructions
3. Product Features
The ZIBOO Digital Clamp Meter series offers a robust set of features for various electrical measurement tasks:
- True RMS: Provides accurate readings for non-sinusoidal waveforms.
- NCV (Non-Contact Voltage) Detection: Red LED flashing for live wire detection without physical contact.
- High Display Counts: 6000 display counts for precise readings.
- Auto Range: Automatically selects the correct measurement range.
- Backlight: For clear visibility in dimly lit environments.
- Diode Test: For checking diode functionality.
- Continuity Buzzer: Audible indication for circuit continuity.
- Data Hold: Freezes the current reading on the display.
- AC/DC Current: Measures up to 1000A.
- AC/DC Voltage: Measures up to 1000V AC and 1000V DC (376) or 1700V DC (393).
- LowZ (Low Impedance) Measurement: For ghost voltage detection.
- VFD (Variable Frequency Drive) Measurement: For accurate readings on VFD circuits.
- Capacitance and Resistance Measurement: Comprehensive electrical testing.
- Temperature Measurement: (Model 393 only) Measures temperature in Celsius and Fahrenheit.

Figure 3: Key Features of ZIBOO 376

Figure 4: General Features Overview
4. Setup
Battery Installation
The ZIBOO Digital Clamp Meter requires three AAA 1.5V batteries (LR03). Batteries are typically not included due to shipping regulations.
- Ensure the meter is turned OFF and disconnect any test leads from the circuit and the meter.
- Locate the battery compartment on the back of the meter.
- Unscrew the battery cover using a suitable screwdriver.
- Insert three AAA 1.5V batteries, observing the correct polarity (+/-) as indicated inside the compartment.
- Replace the battery cover and securely tighten the screw.
Warning: Do not operate the meter with the battery cover removed.

Figure 5: Battery Replacement Diagram
5. Operating Instructions
Description of Appearance
- Current Clamp Wire Measurement Center Point: The area where current is measured by clamping around a conductor.
- Dial Switch: Used to select the desired measurement function.
- LCD Display: Shows measurement readings, symbols, and indicators.
- VΩ (Voltage/Resistance) Red Test Pen Input Port: For connecting the red test lead.
- COM (Common) Black Test Pen Input Port: For connecting the black test lead.

Figure 6: Meter Components
LCD Display and Symbols
The LCD display provides various symbols to indicate the current measurement mode, status, and readings. Refer to the table below for common symbols:
| Symbol | Explanation |
|---|---|
| OFF | Turn off the power |
| ⏻ | Auto power-off |
| 🔋 | Low battery indication |
| --- (mV) | DC millivolt |
| --- V | DC voltage |
| TRUE RMS | True RMS measurement |
| ~ V | AC voltage |
| Hz | Frequency |
| % | Duty cycle measurement |
| VFD | AC voltage frequency conversion measurement |
| --- A | DC current |
| ~ A | AC current |
| Ω KΩ MΩ | Resistance |
| ♫ →|→ | Continuity beeper, Diode |
| |⊢ nF uF mF | Capacitance |
| °C | Centigrade scale |
| °F | Fahrenheit temperature |
| NCV EF | Non-contact sensing signal |
| LIVE | Live wire |
Key Functions
| Button | Function |
|---|---|
| FUNC/VFD | Function/Frequency conversion measurement |
| INRUSH/PEAK | Inrush Current/Peak Current |
| ZERO/RANGE | Zero clearance/Measurement range |
| MAX/MIN | Max/Min value display |
| HOLD ☀ | Data hold/Backlight toggle |
Quick Tutorial / Measurement Examples
Always ensure the meter is set to the correct function before making any measurements.
| Measurement Range | Test Pen Link Hole | Measurement Example |
|---|---|---|
| ACA 0/1000A | Clamp line induction | Measure AC current, distribution box load |
| DCA 0/1000A | Clamp line induction | Measure DC current, electric vehicle DC |
| ACV/Hz/% | Black(COM), Red(VΩ) | AC voltage 220V/50HZ, duty cycle measurement |
| ACV (VFD Frequency) | Black(COM), Red(VΩ) | VFD frequency conversion measurement (e.g., variable frequency air conditioning voltage) |
| LowZ ACV/Hz | Black(COM), Red(VΩ) | ACV instability and interference signal measurement |
| DCV | Black(COM), Red(VΩ) | Electric vehicle battery voltage 36V, 48V |
| Resistance /Continuity/Diode | Black(COM), Red(VΩ) | Chip resistance, power resistance |
| Capacitance | Black(COM), Red(VΩ) | SMD capacitance, Electrolytic capacitor |
| Temperature | Black(COM), Red(VΩ) | Insert the temperature test pen into the cooling port of the air conditioner |
| NCV/LIVE | - , Red(VΩ) | Contactless sensing and AC Live wire detection |
Product Demonstration Video
Video 1: ZIBOO Digital Clamp Meter features and application demonstration, including short circuit buzzing, resistance test, capacitance test, NCV, backlight, AC current test, and DC voltage test.

Figure 7: Application Examples
6. Maintenance
Battery Replacement
Refer to the "Setup" section for detailed instructions on battery replacement. Always ensure the meter is OFF and test leads are disconnected before opening the battery compartment.
General Care and Cleaning
- Keep the meter dry. If it gets wet, wipe it dry immediately.
- Use a soft, dry cloth to clean the case. Do not use abrasives or solvents.
- Store the meter in a cool, dry place away from direct sunlight and extreme temperatures.
- If the meter is not used for a long period, remove the batteries to prevent leakage.
Repair
Warning: Do not attempt to repair the meter yourself.
Please have the cover open for repairs by an approved and professionally experienced technician. If the fault cannot be solved, please contact the official after-sales service in time. Non-professionals please do not operate to avoid damage to the instrument or risk of electric shock caused by improper maintenance.
7. Troubleshooting
If the meter does not function correctly, try the following basic troubleshooting steps:
- No Display or Faint Display: Check battery level. Replace batteries if low.
- Incorrect Readings: Ensure the correct function is selected on the dial. Check test leads for damage or poor connection. Verify the circuit is within the meter's specified range.
- Meter Does Not Respond: Turn the meter off and then on again. If the issue persists, replace the batteries.
- "OL" Display: Indicates an overload (measurement exceeds the selected range). Switch to a higher range or ensure the input is within the meter's maximum capabilities.
If these steps do not resolve the issue, please contact customer support.
8. Specifications
General Technical Indicators
- Safety Level: CATII 600V, CATIII 300V
- Product Range: Automatic
- Maximum Display: 6000 counts
- Sampling Rate: 3 times/second
- Overload Display: "OL"
- Auto Power Off: Approximately 15 minutes
- Operating Temperature: 0°C to 40°C
- Storage Temperature: -10°C to 60°C
- Pollution Grade: 2
- Altitude: 0 to 2000m
- Power: 3 x AAA 1.5V batteries
- Dimensions: 263H x 83W x 48D mm
- Weight: 350g (inclusive of battery)
Measurement Specifications
| Function | Range | Resolution | Accuracy |
|---|---|---|---|
| AC Current | 60A | 0.01A | ±(2%+5)/100Hz |
| 600A | 0.1A | ||
| 1000A | 1A | ||
| DC Current | 60A | 0.01A | ±(2%+5) |
| 600A | 0.1A | ||
| 1000A | 1A | ||
| High Voltage Detection | DC1700V | 1V | ±(2%+10) |
| AC1000V | 1V | ||
| AC Voltage | 6V | 0.001V | ±(0.8%+3)/400Hz |
| 60V | 0.01V | ±(1.3%+5)/1KHz | |
| 600V | 0.1V | ±(1.5%+5)/1KHz | |
| 1000V | 1V | ||
| VFD (AC Voltage) | 100V-600V | 0.1V | ±(4%+5)/400Hz |
| DC Voltage | 600mV | 0.1mV | ±(0.5%+3) |
| 6V | 0.001V | ||
| 60V | 0.01V | ||
| 600V/1000V (376) / 1700V (393) | 0.1V/1V | ||
| Resistance | 600Ω | 0.1Ω | ±(1%+5) |
| 6KΩ | 0.001KΩ | ||
| 60KΩ | 0.01KΩ | ||
| 600KΩ | 0.1KΩ | ||
| 6MΩ | 0.001MΩ | ±(2%+5) | |
| 60MΩ | 0.01MΩ | ||
| Capacitance | 60nF | 0.01nF | ±(4%+5) |
| 600nF | 0.1nF | ||
| 600uF | 0.1uF | ||
| 6000uF | 0.01mF | ±(8%+5) | |
| 60mF | 0.01mF | ||
| Temperature (393 only) | -40°C to 10°C | 1°C | ±4°C |
| 10°C to 1000°C | 1°C | ±(1.5%+4°C) | |
| Frequency (Hz) | 10.00Hz | 0.01Hz | ±(0.5%+5) |
| 100.0Hz | 0.1Hz | ||
| 1.000KHz | 0.001KHz | ||
| 10.00KHz | 0.01KHz | ||
| 100.0KHz | 0.1KHz | ||
| 1.000MHz | 0.001MHz | ||
| 20.00MHz | 0.01MHz | ||
| Duty Cycle | 10~90% | 0.1% | ±(1%+5) |
Note: Overload protection for most functions is PTC Thermistor; 1000Vrms.
9. User Tips
- Verify Model: Upon receiving your meter, double-check the model number (376 or 393) to ensure it matches your order and intended use, especially if specific high-voltage capabilities (like 1700V DC on the 393) are critical for your tasks.
- Test Leads Check: Always inspect your test leads for any signs of wear, cracks, or damage before each use. Damaged leads can lead to inaccurate readings or safety hazards.
- Backlight Usage: Utilize the backlight function in poorly lit areas for clear display readings, but remember that continuous use can drain batteries faster.
- Auto-Ranging Convenience: The auto-ranging feature simplifies operation, but for very precise measurements or specific troubleshooting, understanding the manual range selection (if available) can be beneficial.
10. Warranty and Support
For technical support, warranty claims, or service inquiries, please contact ZIBOO customer support:
- Telephone: +86-532-88900998
- E-Mail: sales-support@ziboo.online
Please have your product model and purchase information ready when contacting support.
User Manual Version: REV01-202603
For the most up-to-date information, please refer to the official ZIBOO Digital Clamp Meter Quick Guide (User Manual) PDF: View PDF Manual