Introduction

The TS607 is a high-precision internal resistance meter and voltmeter tester designed for lithium batteries. It features a 1.77-inch TFT color display and utilizes an AC 4-wire method for stable and accurate measurements. It supports voltage and internal resistance display fine-tuning, manual data logging for up to 99 sets of data, adjustable auto power-off, and internal resistance grading (A, B, C, D). This versatile tool is suitable for maker testing, energy storage battery testing, and power bank assembly.

TS607 Voltage & Resistance Tester with 1.77-inch TFT Color LCD and AC 4-Wire Method. Displays Voltage Test Range 0.001V~60.00V, Resistance Test Range 0.1mΩ~6.999Ω, and Manual Data Logging up to 99 sets of records.

TS607 Voltage & Resistance Tester with 1.77-inch TFT Color LCD and AC 4-Wire Method. Displays Voltage Test Range 0.001V~60.00V, Resistance Test Range 0.1mΩ~6.999Ω, and Manual Data Logging up to 99 sets of records.

A short video demonstrating the TS607 Internal Resistance Meter Tester and its included cables.

Specifications

Parameter Value
Product NameTS607 Voltage and Internal Resistance Tester
Operating VoltageDC 5V (Do not exceed this voltage)
Testing PrincipleAC 4-wire method
Voltage Testing Range0.001V ~ 60.00V
Voltage Resolution0.001V
Internal Resistance Measurement Range0.1mΩ ~ 6.999Ω
Internal Resistance Resolution0.1mΩ
Data LoggingUp to 99 sets of voltage and internal resistance data (manual record)
Voltage Display CalibrationSupported
Internal Resistance Display CalibrationSupported
Voltage Pass/Fail ReferenceSupported
Internal Resistance Grading/SortingSupported (A, B, C, D four-grade sorting)
Auto Power-OffSupported (Standby time adjustable from 1 to 9 minutes)
Backlight BrightnessAdjustable from level 1 to 9
Standby Current (screen on)30mA
Standby Current (screen off)< 1mA
Product Dimensions79.5 x 42.1 x 27.8 mm
Mounting Cutout77 x 39.3 mm
Product Weight45g
Table of TS607 product parameters including working voltage, testing principle, voltage range, resistance range, data logging, fine-tuning support, auto shutdown, backlight brightness, and accessories.

Table of TS607 product parameters.

Setup

4. Power Supply Methods

The TS607 requires a DC 5V power supply. Do not provide overvoltage power supply. The device is prohibited from testing AC voltage and voltages exceeding 60V.

4.1 DC 5V or 18650 Battery Two-Wire Power Supply Method

Connect the thin red wire to the positive (+) terminal and the thin black wire to the negative (-) terminal. The yellow wire is not used; ensure it is insulated.

Diagram showing DC 5V power supply connection to the TS607 using red (+) and black (-) wires.

Power supply connection for the TS607.

4.2 18650 Battery + Power Supply Adapter Board

Alternatively, the device can be powered using an 18650 battery with a power supply adapter board. Ensure correct polarity when connecting.

Connection of the TS607 to a power supply adapter board, showing wiring details for AD- and V-V+.

Connecting the TS607 to a power supply adapter board.

5. Clamping Test Demonstration

Before use, prepare a 5V power source or an 18650 battery. Use the XH-2.54-4P signal acquisition cable to create a custom test fixture, or purchase accessories separately (e.g., XH2.54-4P to Kelvin Clip or XH2.54-4P to Battery Test Stand).

5.1 Optional: XH2.54-4P to Kelvin Clip Testing

Connect the XH2.54-4P to the 4P terminal. Clamp the Kelvin clips onto both ends of the component under test.

Demonstration of connecting the TS607 to a component using Kelvin clips for testing.

Clamping a component for testing using Kelvin clips.

5.2 Optional: Battery Test Stand Testing

For battery testing, use an XH2.54-4P to Battery Test Stand accessory. The movable end presses against the battery negative terminal, and the fixed end presses against the battery positive terminal.

Battery test stand accessory for the TS607, showing how it connects to a battery.

Battery test stand accessory for the TS607.

Operating Instructions

6.1 Power On/Off

  • The device powers on automatically upon initial connection.
  • In standby mode, an auto-power-off countdown begins (default 2 minutes, adjustable).
  • Press and hold the "R" key to manually power off.
  • In the powered-off state, press the "R" key once to power on.
TS607 automatically enters energy-saving mode based on usage frequency.

The TS607 features an automatic energy-saving mode.

6.2 Log Internal Resistance Measurement Value

  • After measuring voltage and internal resistance, press the "M" key once to log the measured values.
  • Press and hold the "M" key for 3 seconds to quickly clear all logged internal resistance measurements.
TS607 allows manual recording of up to 99 sets of voltage and internal resistance data for local viewing.

Manual data logging on the TS607.

6.3 Enter Setup Menu

Press and hold the "M" key for 3 seconds to enter the menu. Press the "M" key to cycle through menu options. Use the Up/Down arrow keys to adjust values.

TS607 supports voltage display fine-tuning function, allowing subtle adjustments to measurement results.

Accessing the setup menu and fine-tuning options.

6.4 Chinese/English Language Switch

In Menu Item 01, press the "Up" or "Down" arrow keys to switch between Chinese and English display.

6.5 Voltage Display Calibration

Press the "Up" or "Down" arrow keys to calibrate the displayed voltage value. Note that calibration only affects the displayed value, not the actual measured value.

6.6 Internal Resistance Display Calibration

Press the "Up" or "Down" arrow keys to calibrate the displayed internal resistance value. Calibration only affects the displayed value, not the actual measured resistance.

6.7 Standby Time Adjustment

Press the "Up" or "Down" arrow keys to adjust the standby time before auto power-off.

TS607 supports 1-9 minute standby time adjustment for optimal use in various lighting conditions.

Adjusting the standby time on the TS607.

6.8 Display Backlight Adjustment

Press the "Up" or "Down" arrow keys to adjust the screen brightness level.

6.9~6.10 Voltage Judgment (Upper and Lower Limits)

Voltage judgment is a reference value for battery status derived from the Upper Voltage Limit and Lower Voltage Limit. Default settings are for single-cell Li-ion (NMC/NCA) voltage limits. These can be adjusted based on testing requirements. The judgment result is for reference only.

Voltage Condition Judgment Result
V-LOW ≤ U ≤ V-TOPPASS
U < V-LOW or U > V-TOPFAIL

The voltage judgment result is displayed directly during testing with color change prompts (e.g., green for PASS, red for FAIL).

Internal Resistance Sorting

Battery internal resistance sorting differs from simple upper/lower limit voltage judgment. Simple limits are also unsuitable for internal resistance sorting. Internal resistance sorting aims to "group" individual battery cells with similar internal resistance values, screening out abnormal cells with excessively high or low resistance to ensure the cells combined in a battery pack exhibit highly consistent electrical characteristics. As internal resistance reflects the battery's internal chemical and structural condition, sorting by internal resistance essentially sorts by battery health state and microscopic consistency. Simply put, it categorizes batteries into different grades (e.g., A, B, C, D) by internal resistance. Cells of the same grade are assembled together for use in different applications, enhancing safety and maximizing battery utility.

Explanation of internal resistance sorting for batteries, detailing how it helps group cells with similar characteristics for improved safety and performance.

Internal resistance sorting for battery cells.

Condition Grade
R-A Resistance ≤ R-BA
R-B < Resistance ≤ R-CB
R-C Resistance ≤ R-DC
R-D < Resistance OR Resistance ≤ R-A DD

Note: The internal resistance sorting values (6.11~6.15) are preset reference values that can be adjusted based on actual needs. The sorting result is displayed on the test interface with corresponding color indicators.

6.16 Restore Factory Settings

Press the "Up" or "Down" arrow keys to restore factory settings. "OK" will be displayed after restoration.

6.17 Clear All Logged Records

Press the "Up" or "Down" arrow keys to clear all logged records.

6.18 Exit Settings Menu

When on the "Exit" menu item, press "Up" or "Down" arrow keys to exit the system menu.

6.19 Auto Power-Off

In standby mode, the device automatically powers off when the countdown ends.

Maintenance

No specific maintenance instructions are provided in the available documentation. Generally, keep the device clean and dry. Avoid exposing it to extreme temperatures or humidity. Do not disassemble the device as it may void any implied warranty and could damage the internal components.

Troubleshooting

No specific troubleshooting guide is provided in the available documentation. If the device is not functioning as expected, please check the following:

  • Ensure the power supply is DC 5V and correctly connected.
  • Verify that the test leads are securely connected to the device and the component being tested.
  • Check for any error messages on the display.
  • If the device is unresponsive, try powering it off and on again.
  • Refer to the User Manual (PDF) for further details.

User Tips

  • For quick checks and general functionality verification, the device performs well.
  • Always ensure the correct voltage and internal resistance ranges are selected for accurate measurements.
  • Utilize the data logging feature to keep track of multiple test results for comparison or record-keeping.

Warranty and Support

Specific warranty information is not provided in the available documentation. For warranty claims or technical support, please contact the seller or manufacturer directly. Keep your purchase receipt as proof of purchase.

A comprehensive user manual is available in PDF format: TS607 User Manual (PDF).

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.