1. Safety Information
1.1 Safety Brief
This manual contains important safety instructions that must be observed when operating the SPPS-D*X series linear DC regulated power supply. To ensure your personal safety and ensure that this product works in the best environment, please read this manual carefully before use.
When receiving a brand-new power supply, you need to do necessary inspections to ensure the normal operation of the instrument:
- Check for any damage during transportation.
- Check whether all accessories are complete.
- Check whether the output voltage and output current are normal after turning on the device.
If any problems are found, please contact the dealer immediately.
1.2 Safety Symbols
The following safety symbols will appear in this manual or on the machine:
| Symbol | Description |
|---|---|
| ! | Pay attention to the warning signs |
| ⚡ | High voltage danger sign |
| ⏚ or GND | Ground connection sign |
| + | Positive terminal |
| - | Negative terminal |
1.3 General Warnings
- Do not use a damaged device. Before using the device, check its casing first. Check for any cracks. Do not operate this device in an environment containing explosive gases, vapors, dust, moisture or acids.
- Use wires with appropriate rated loads. The capacity of all load wires must be able to withstand the maximum short-circuit output current of the power supply without overheating. To reduce the risk of fire and electric shock, ensure that the voltage fluctuation of the mains power supply does not exceed 10% of the working voltage range.
- If using the power supply to charge a battery, pay attention to the positive and negative polarities of the battery when connecting the wires, otherwise the power supply will be burned out!
- Do not install alternative parts on the device by yourself or perform any unauthorized modifications. Do not use this device when the detachable cover is removed or loose.
- It is strictly prohibited to use this device in life support systems or any other equipment with safety requirements.
- Risk of electric shock, please ground the device. This product has a protective grounding terminal. To minimize the risk of electric shock, the instrument must be connected to the AC power supply through a grounding power cord, and the grounding wire must be firmly connected to the grounding (safety ground) terminal of the power socket or the AC distribution box. Interrupting the protective (grounding) wire or disconnecting the connection of the grounding protection terminal will lead to a potential electric shock hazard, which may cause personal injury or death.
- Before turning on the power, confirm that all safety precautions have been taken. All connections must be made with the device power turned off, and all connections must be made by qualified personnel familiar with the relevant hazards. Incorrect operation may cause fatal injury and equipment damage.
- After turning off the device, there may still be a dangerous voltage on the positive and negative electrodes. Never touch the cables or electrodes immediately. Ensure that there is no dangerous voltage on the electrodes or sensing terminals before touching them.
- If the device is not used in the manner specified by the manufacturer, the protection provided by the device may be damaged.
- Do not clean the inside of the device.
- Never block the ventilation holes of the device.
2. Product Overview
The KUAIQU SPPS-D*X series of programmable high-precision adjustable DC regulated power supplies is specifically designed for laboratories, factories, R & D teams, and school students. The output voltage and current can be continuously adjusted between 0 and the nominal value. This series of power supplies has good stability and a low ripple coefficient, and has a perfect protection circuit. This power supply can be used as both a regulated voltage power supply and a regulated current power supply.
The main special functions and advantages of the SPPS-D*X series of power supplies are as follows:
- 2.8-inch liquid crystal display
- OCP and OVP functions, over-temperature protection.
- High precision, high resolution.
- Low ripple, low noise.
- Intelligent fan control is adopted to save energy.
- Equipped with RS232/USB/RS485 communication interfaces, and when connected to the upper computer, it can output according to the voltage and current values programmed in the program.
- The voltage and current can be adjusted by using the coding switch knob.
- With USB charging, and the voltage and current values of charging are displayed on the screen.

Figure 2.1: Front view of the KUAIQU SPPS-D603X-R Linear DC Power Supply

Figure 2.2: Product Introduction with Labeled Front Panel Features
3. Product Dimensions
This power supply needs to be installed in a space with good ventilation and a reasonable size. Please select a suitable space for installation according to the following introduction of the power supply dimensions.
The dimensional data of the power supply structure diagram is as follows (unit: millimeter):
- Length: 240mm (312mm with handle)
- Width: 147.5mm
- Height: 125mm
- Weight: 4.4 Kg (for SPPS-D302X, D303X, D305X, D602X, D603X) or 5.5 Kg (for SPPS-D3010X, D1202X, D605X)

Figure 3.1: Product Dimensions Diagram (Unit: mm)
4. Panel Description
4.1 Front Panel

Figure 4.1: Front Panel Layout
- Voltage output display: Shows the current output voltage.
- Current output display: Shows the current output current.
- Power output display: Shows the current output power.
- Current storage call item: Indicates the active memory preset.
- Voltage and current setting values: Displays the set voltage and current.
- USB output voltage and current value display: Shows the voltage and current for the USB charging port.
- Constant voltage/constant current indication mark: Indicates CV (Constant Voltage) or CC (Constant Current) mode.
- Panel lock mark: Indicates if the panel is locked.
- Voltage and current adjustment knob: Press to move the cursor position, rotate to adjust values.
- OCP over-current protection switch: Button for Over-Current Protection.
- OVP over-voltage protection switch: Button for Over-Voltage Protection.
- Curve display/return: Button to enter/exit curve display mode.
- Voltage/current adjustment toggle switch: Switches between voltage and current adjustment modes. Long press for 5 seconds to open or lock the panel buttons.
- Storage call button: Long press for 5 seconds to turn on or off the buzzer.
- Output on/off button: Toggles power output.
- Slope output mode: Button for Slope function.
- Power switch: Main power on/off.
- USB charging socket (5V2A): For charging devices.
- -Negative pole (black): Negative output terminal.
- GND grounding terminal (green): Ground connection.
- +Positive pole (red): Positive output terminal.
4.2 Rear Panel

Figure 4.2: Rear Panel Layout with Communication Ports
- Temperature-controlled fan: For cooling.
- Power socket: AC input.
- Fuse box: Contains the fuse.
- Remote control USB + RS232 + RS485 Interface (optional): For PC communication.
5. Specifications
The KUAIQU SPPS-D*X series offers various models with different voltage, current, and power ratings. Below are the detailed specifications:
5.1 General Specifications
| Attribute | Value | |
|---|---|---|
| Semi-finished product | No | |
| Voltage | Others (Specific models vary) | |
| High-concerned chemical | None | |
| Origin | Mainland China | |
| Input Voltage | 200Vac~240Vac 50Hz (100Vac~120Vac 60Hz) | |
| Product Dimension | 240mm*147.5mm*125 mm (some models 312mm*147.5mm*125mm) | |
| Product Weight | 4.4 Kg or 5.5 Kg | |
| Operating temperature | 0°C - 40℃ | |
| Operating humidity | <80%RH | |
| Storage temperature | -10°C - 70℃ | |
| Altitude | Highest operating altitude is 2000 meters | |
| Pollution degree | Pollution degree 2 |
| Parameter | Voltage | Current |
|---|---|---|
| Load regulation rate | ≤0.01%+10mV | ≤0.01%+5mA |
| Power regulation rate | ≤0.01%+3mV | ≤0.1%+3mA |
| Set value resolution | 1mV | 1mA |
| Read back value resolution | 1mV | 1mA |
| Set value accuracy | ≤0.03%+10mV | ≤0.1%+10mA |
| Read back value accuracy | ≤0.03%+10mV | ≤0.1%+10mA |
| Ripple (20Hz~20MHz) | ≤15mV(p-p) / ≤3mV(rms) | ≤10mA(rms) |
| Rise time (No load) | ≤50ms | |
| Rise time (Full load) | ≤200ms | |
| Fall time (No load) | ≤500ms | |
| Fall time (Full load) | ≤50ms |
For specific model ratings, please refer to the table on page 9 of the PDF manual.

Figure 5.1: Oscilloscope showing low ripple output (5.76mV peak-to-peak)

Figure 5.2: High-Precision Stable Output with Multimeter showing 30.00V, 10.00A, 300.0W

Figure 5.3: Internal view highlighting the Pure Copper Transformer for high efficiency and low heat.
6. Setup and Work Requirements
6.1 Environmental Conditions
The SPPS-D*X series of power supplies is only allowed to be used indoors and in low-condensation areas. The following table shows the general environmental requirements of this device.
- Operating temperature: 0°C - 40℃
- Operating humidity: <80%RH
- Storage temperature: -10°C - 70℃
- Altitude: The highest operating altitude is 2000 meters
- Pollution degree: Pollution degree 2.
6.2 AC Input
Please ensure the input voltage of this product is correct. Input Voltage: 200V~240V 50Hz (100~120V 60Hz). Incorrect AC voltage input will cause serious damage to the equipment. Please ensure the required input voltage value.
Do not use in an environment where the temperature exceeds 40 degrees Celsius. The cooling fan is located at the rear of the device, and there should be enough space to facilitate heat dissipation.
6.3 Connecting the Load
Improper connection may damage the power supply and the load connected to the power supply. When connecting the battery load, do not reverse the polarity of "+" and "-", otherwise the power supply may be damaged.
- Turn the terminal knob counterclockwise.
- Insert the load terminal.
- Turn the terminal knob clockwise.
- The banana plug can be directly inserted into the terminal hole.

Figure 6.1: Diagram illustrating how to connect the load terminals.
7. Operating Instructions
7.1 Power-on and Power-off
- Power-on: Press the "POWER" switch to turn on the power supply. The screen is initialized and will display the voltage and current values before the last shutdown.
- Power-off: Press the "POWER" switch again to turn off the power supply.
7.2 Voltage and Current Setting
Press the V/A button to switch between voltage and current adjustment. Use the "ADJUST" knob to adjust the voltage and current values. Usually, the voltage and current are in the fine-tuning mode. When entering the voltage and current setting, the currently set number is prompted by flashing; rotate clockwise to increase the value and counterclockwise to decrease the value. Press the "ADJUST" switch to enter the coarse-tuning mode, and each press moves the cursor one position to the left.

Figure 7.1: Encoder Adjustment Knob for precise voltage and current setting.
7.3 Output Switch
Press the "OUTPUT" output key, the output is turned on, and the output key light is on at this time. Press the output key again, the output is turned off, and the output key light is off.
Note: When calling other settings from the storage, that is, calling the storage parameters, the output will be automatically turned off. Long press the output "OUTPUT" key for 5 seconds, and when calling other settings from the storage, the output will not be turned off. Long press the output "OUTPUT" key for 5 seconds to switch between these two states.
7.4 Slope Function
This power supply provides a Slope output mode, that is, the starting voltage and current change and output to the set voltage and current values in the form of a diagonal line track within the set output time.
Slope mode setting: Click the "Slope" key to enter the slope function setting interface. In this interface, the following items can be set: starting voltage V, ending voltage V, starting current A, ending current A, output interval time S, number of cycles T, whether to maintain output after the cycle ends (YES/NO). At this time, click the "V/A" key, and the editing cursor will move downwards in turn. Select the item to be modified, and rotate the "ADJUST" knob (pressing the "ADJUST" knob can move the position of the editing cursor) to modify the item to be edited. After the modification is completed, long press the "ADJUST" knob for 3 seconds, and this group of values will be saved; after the modification is completed, directly press the "Slope" key to exit this interface, and this group of modified values will not be saved.
Tip: If the number of cycles T is set to 0, it means infinite cycles.
Slope output function: Click the "Slope" key to enter the Slope function interface. At this time, press the "OUTPUT" output key, and the output will be repeated in cycles according to this group of set values. At this time, the real-time voltage and current values of the output are displayed at the top of the screen. If the "Slope" key or the "OUTPUT" key is pressed again, the output can be stopped.

Figure 7.2: Slope Function Setting Interface
Video 7.1: Demonstration of the slope function and linear output on an oscilloscope.
7.5 Curve Display Function
Press the "Curve" key to enter the real-time regulation output curve interface of voltage and current. The voltage and current curves will only be displayed when the "OUTPUT" output key is turned on. When entering the curve graph interface, the time of power output will be displayed at the bottom of the screen, and the regulated and set voltage and current values will be displayed at the top of the screen. In this interface, the voltage and current will update and keep the curve graph within 5 seconds. Press the "Curve" key again to exit the voltage and current curve interface.

Figure 7.3: Dual Output Curve Display showing real-time voltage and current graphs.
7.6 Storage and Call Settings (Memory Presets)
Press the "Memory" key to enter the storage and call settings interface. This power supply has 99 groups of internal voltage and current storage from M1 to M99.
Setting a group: Press the "Memory" key and rotate the "ADJUST" knob. The gray voltage and current group cursor will move up and down. Select the voltage and current group that needs to be edited. Click the "V/A" button, and the editing cursor will stay at the voltage value of this group. Rotate the "ADJUST" knob (or press the "ADJUST" knob to move the position of the editing cursor) to modify the voltage value of this group. Click the "V/A" button again, and the editing cursor will switch to the current value of this group. Rotate the "ADJUST" knob (or press the "ADJUST" knob to move the position of the editing cursor) to modify the current value of this group. After the editing of the voltage and current values of this group is completed, click the "V/A" button again, and the new voltage and current values of this group will be saved. After the editing of the voltage and current values of this group is completed, directly press the "Memory" key, and then exit the storage interface and the new voltage and current values of this group will not be saved.
Calling a group: Press the "Memory" key and rotate the "ADJUST" knob. The gray voltage and current group cursor will move up and down. Select the voltage and current group that needs to be called. Press the "ADJUST" knob again. At this time, this voltage and current group turns purple, and the voltage and current values of this group are called. Press the "Memory" key to exit the storage interface, and the M symbol of the called voltage and current group is displayed on the main interface screen.
The temporarily set voltage and current values are displayed as M0. M0 changes at any time according to the temporarily set voltage and current values. The M symbol at the bottom of the screen represents the group of voltage and current values that are being called.
Note: When the "OUTPUT" is turned on and during the power output process, when a storage is called, the output will be automatically turned off to avoid damage to the load caused by excessive voltage due to misoperation. If you want to change and call a new voltage and current group during the power output process without turning off the output, just long press the output "OUTPUT" key for 5 seconds to switch.

Figure 7.4: Memory Presets for quick recall of settings.
7.7 USB Charging Function
The power supply is equipped with a 5V2A USB charging port, and the charging voltage and charging current are displayed on the screen during charging.
7.8 Host Computer Operation Mode
Connect the power supply to the PC and use the host computer software to perform relevant operations on the power supply on the PC. This power supply is standard with three communication interfaces: RS232, USB, and RS485, and the user can choose any one to achieve communication with the computer. When programming and operating on the host computer, the buttons on the power supply panel are locked. For the connection method between the power supply and the host computer, see the host computer operation instruction page.
8. Protection Functions
8.1 Over-Current Protection Function (OCP)
Press the "OCP" key to turn on or off the short-circuit protection alarm function (OCP). Hold the "OCP" button for 3 seconds to enter the OCP setting state, and rotate the ADJUST knob to set the OCP current value. After the OCP over-current protection function is turned on, when the machine detects that the external load is short-circuited or over-current, the machine will stop outputting and give an alarm prompt to effectively protect the external load.

Figure 8.1: OCP (Over-Current Protection) warning display.
8.2 Over-Voltage Protection Function (OVP)
Press the "OVP" button to enable or disable the OVP over-voltage protection function. Hold the "OVP" button for 3 seconds to enter the OVP setting state, and rotate the ADJUST knob to set the OVP voltage value. When OVP is enabled, when the load voltage exceeds the set voltage, the machine will stop outputting and give an alarm to effectively protect the external load. Short-press the OVP button to clear the OVP alarm.

Figure 8.2: OVP (Over-Voltage Protection) warning display.
9. Maintenance
9.1 Product Maintenance
- Disconnect the power supply when the machine is not in use.
- Unplug the power plug before cleaning the machine.
- Do not use hydrocarbons, chlorides or similar solvents, nor use abrasive cleaners when cleaning the machine.
9.2 Replace the Fuse
If the fuse blows, the power supply will stop working. To find and correct the cause of the blown fuse, replace the fuse with one of the same specification.
Method of replacing the fuse:
- First, remove the power plug.
- Then open the fuse holder according to the view (located on the power socket).
- After replacing with a fuse of the same model, reinstall the fuse holder.
For effective safety protection, only fuses of specific specifications are allowed to be replaced. Before replacing the fuse, the power must be turned off and the power cord must be pulled out from the power socket.

Figure 9.1: Diagram showing fuse holder location and replacement steps.
10. Troubleshooting
This section provides guidance for common issues. For more complex problems, please refer to the full user manual or contact support.
- No Power: Check the power cord connection and the fuse. If the fuse is blown, replace it as per the maintenance section. Ensure the power switch is ON.
- No Output Voltage/Current: Ensure the output switch is ON. Check if OCP or OVP is triggered (indicated by screen alerts and alarms). Clear any OCP/OVP alarms by short-pressing the OVP button. Verify load connections.
- Unstable Output: Ensure the input AC voltage is stable and within the specified range. Check for proper grounding.
- Overheating: Ensure adequate ventilation around the device. The cooling fan should have enough space to operate effectively. Do not block the ventilation holes.
- Inaccurate Readings: Allow the device to preheat for 30 minutes for optimal accuracy. Ensure the load is connected correctly.
11. User Tips
- Precision Control: Utilize the encoder knob for fine-tuning voltage and current. A quick press changes digit position, while rotation adjusts the value.
- Automate Tests: Leverage the 'Slope' function for controlled power-up/down sequences and programmable 'Memory' presets for repetitive tasks, saving time and preventing errors.
- Monitor Performance: Use the 'Curve' display function to visualize real-time voltage and current waveforms, which is invaluable for debugging and understanding circuit behavior without needing an external oscilloscope.
- Protect Your Devices: Always set appropriate OCP (Over-Current Protection) and OVP (Over-Voltage Protection) limits before connecting sensitive components to prevent damage from unexpected surges or shorts.
- Remote Control: For advanced applications and data logging, connect the power supply to a PC via USB, RS232, or RS485 using the host computer software.
12. Warranty and Support
12.1 Product Warranty
This product provides free maintenance services within one year from the date of purchase, except in the following cases:
- The warranty card of this product is missing.
- Malfunctions caused by improper use, such as improper operation, maintenance, modification or adjustment of the equipment.
- Consumables are not covered by the warranty.
- Use in an environment other than the working environment conditions required by the product and in a humid, acidic and polluted environment. (Product environment conditions: working temperature: 0℃ -40℃, working humidity: <80%RH, storage temperature: -10℃ - 70℃).
- Natural irresistible disasters such as floods, fires, earthquakes, etc.
Maintenance beyond the warranty period requires maintenance fees, and the maintenance fees are borne by the user.
12.2 Packing List
- 1* Power Supply
- 1* Power Cord
- 1* Output load line
- 1* USB cable (Depending on the model)
- 1* User's Manual
- 1* Warranty Card
12.3 Manufacturer Information
Company: Shenzhen Kuaiqu Electronic Co., Ltd
Address: Room 303, Building 7, Kangli City, No. 66 Pingji Avenue, Shanglilang Community, Nanwan Street, Longgang District, Shenzhen, China
For further assistance, please refer to the official user manual PDF: View User Manual (PDF)
Documents and downloads
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.