Contents

XY-S485 Industrial Isolated TTL to RS485 Converter Module

Model: XY-S485 | Brand: LIZAO

1. Introduction and Overview

The LIZAO XY-S485 is an industrial-grade isolated TTL to RS485 converter module designed for reliable long-distance serial communication in industrial control systems, including Modbus RTU applications. It features power and signal isolation, automatic flow control, and wide voltage compatibility, ensuring robust performance in challenging environments.

Key Features:

  • Industrial-grade isolated TTL to RS485 conversion.
  • Power and signal isolation for enhanced reliability and safety.
  • Automatic flow control for seamless data transmission.
  • Wide power supply range: DC 3.0V to 5.5V.
  • Compatible with both 3.3V and 5.5V TTL signals.
  • High-end isolated RS485 chip with strong anti-interference ability.
  • Isolation voltage up to 16KV.
  • Supports baud rates from 110bps to 256000bps.
  • Integrated 485 lightning protection design.
  • Equipped with RXD and TXD signal indicators for status monitoring.
  • Standard 2.54mm / 1.25mm pitch for easy integration and secondary development.
  • Includes a 120 ohm matching resistor.
  • Supports multiple communication channels, allowing one network to support up to 256 nodes.
  • Hot-swappable capability.
  • Anti-interference, anti-corrosion, and isolation to prevent signal interference.

2. Setup and Wiring

This section details the physical connections required to integrate the XY-S485 module into your system. Ensure all power is disconnected before making any wiring changes.

2.1 Module Pinout and Function Indication

The module provides clear labels for its TTL and RS485 interfaces. Refer to the diagram below for pin identification and function.

Wiring and Function Indication Diagram for XY-S485 module
Figure 1: Wiring and Function Indication. Shows VCC (3.0-5.5V), TXD, RXD, GND on the TTL side, and A+, B- on the RS485 side. Includes indicators for Transmit (TXD) and Receive (RXD), an isolated RS485 chip, thermal recovery fuse, gas discharge tube, bidirectional current TVS transient suppression diode, and 485 lightning protection design.
  • VCC (3.0V ~ 5.5V): Power supply input for the TTL side.
  • TXD: TTL transmit data output.
  • RXD: TTL receive data input.
  • GND: Ground connection for the TTL side.
  • A+: RS485 differential data line A.
  • B-: RS485 differential data line B.

2.2 Power and Signal Isolation

The module incorporates advanced isolation technology to separate the power and signal lines between the TTL and RS485 sides, preventing ground loops and protecting connected devices from voltage spikes.

Power and Signal Isolation Diagram
Figure 2: Power and Signal Isolation. Illustrates the separation of VDD/GND (TTL side) from Viso/GNDiso (isolated power) and TXD/RXD (TTL signal) from A+/B- (RS485 signal).

2.3 Typical Connection Diagram

For connecting two XY-S485 modules for long-distance communication between two MCUs, follow the diagram below. Ensure proper grounding for lightning protection.

Two Module Connection Diagram
Figure 3: Connection Diagram for two XY-S485 modules. Shows VCC, TXD, RXD, GND of one module connected to an MCU, and A+, B- connected to A+, B- of a second module. The second module's VCC, TXD, RXD, GND are connected to another MCU. Both modules' B- terminals are connected to ground.

Important: For lightning protection, connect the B- terminal of the RS485 interface to ground.

3. Operating Instructions

The XY-S485 module is designed for straightforward operation with automatic flow control.

  • Automatic Flow Control: The module automatically manages the direction of data flow, eliminating the need for external control signals (like DE/RE pins) from the MCU.
  • Baud Rate: The module supports a wide range of baud rates from 110bps to 256000bps. Ensure your MCU and the receiving RS485 device are configured to the same baud rate.
  • Signal Indicators: The onboard RXD and TXD LEDs provide visual feedback on data transmission and reception activity.
    • TXD LED: Flashes when data is being transmitted from the TTL side to the RS485 bus.
    • RXD LED: Flashes when data is being received from the RS485 bus to the TTL side.
  • Modbus RTU Communication: The module is ideal for Modbus RTU communication, facilitating reliable data exchange over long distances in industrial settings.
  • Long-Distance Communication: For optimal performance over long distances (up to 800 meters), it is recommended to use a 2*1.5 shielded twisted pair cable.

4. Maintenance and Care

The XY-S485 module is built for industrial environments and requires minimal maintenance.

  • Operating Environment: Ensure the module operates within its specified temperature range of -40℃ to +85℃.
  • Physical Protection: While robust, avoid exposing the module to excessive moisture, dust, or mechanical stress.
  • Cleaning: If necessary, gently clean the module with a dry, soft cloth. Do not use liquid cleaners or solvents.
  • Connection Integrity: Periodically check all wiring connections to ensure they are secure and free from corrosion.

5. Troubleshooting

If you encounter issues with your XY-S485 module, consider the following common troubleshooting steps:

  • No Communication:
    • Verify power supply (3.0V-5.5V) to the VCC and GND pins.
    • Check all wiring connections for correctness and secure contact.
    • Ensure TXD and RXD lines are correctly connected (TXD of MCU to RXD of module, RXD of MCU to TXD of module).
    • Confirm that the A+ and B- lines of the RS485 bus are correctly connected and not swapped.
    • Verify that all devices on the RS485 bus are configured to the same baud rate.
    • Check if the RXD/TXD indicator LEDs are flashing during data transmission/reception. If not, there might be an issue with the MCU's serial output or the module's power.
  • Intermittent Communication/Data Errors:
    • Ensure proper termination resistors (120 ohm) are used at both ends of a long RS485 bus. The module includes one, but external ones might be needed for the bus.
    • Check for excessive cable length or poor quality cabling. Use shielded twisted pair for long runs.
    • Verify that the B- terminal of the RS485 interface is properly grounded, especially in noisy environments or for lightning protection.
    • Ensure the operating temperature is within the specified range.
  • Module Not Responding:
    • Disconnect and reconnect power.
    • Inspect the module for any visible damage.

If problems persist, consult the seller for further assistance.

6. Specifications

Feature Specification
Model XY-S485 Industrial Isolated TTL to RS485 Converter Module
Supply Voltage (TTL Side) DC 3.0V ~ 5.5V
Dissipation Power Typical 60mW
Operating Temperature -40℃ ~ +85℃
Baud Rate 110bps ~ 256000bps
Isolation Voltage Up to 16KV
Communication Distance Up to 800 meters (with 2*1.5 shielded twisted pair)
Number of Nodes Up to 256
Dimensions (L x W) 50mm x 22.8mm (approx. 46.4mm PCB length)
Application Industrial control system, Modbus RTU communication
Features Power and signal isolation, auto flow control, lightning protection, hot-swappable
Product Dimensions and Back Wiring Diagram
Figure 4: Product Dimensions (50mm x 22.8mm) and Back Wiring Diagram. Shows the layout of components and the wiring diagram printed on the back of the module.

7. User Tips

  • Double-Check Wiring: Always verify your connections, especially VCC, GND, TXD, RXD, A+, and B-, before applying power to prevent damage.
  • Grounding is Key: For stable and protected communication, ensure the B- terminal of the RS485 side is properly grounded, particularly in environments prone to electrical noise or lightning.
  • Cable Quality: Invest in good quality shielded twisted pair cables for long-distance RS485 communication to minimize signal degradation and interference.
  • Power Supply Stability: Use a stable DC 3.0V to 5.5V power supply. Fluctuations can affect module performance.
  • Compatibility: The module is compatible with both 3.3V and 5.5V TTL signals, making it versatile for various microcontrollers.

8. Warranty and Support

The XY-S485 Industrial Isolated TTL to RS485 Converter Module comes with a One-Year Quality Guarantee from the date of purchase.

For technical support, troubleshooting assistance beyond this manual, or warranty claims, please contact the seller directly through the platform where the product was purchased. Provide your order details and a clear description of the issue to facilitate a quicker resolution.

Ask a question about this manual