1. Product Overview
The Yieryi YG-09S is a multifunctional 9-in-1 Soil Tester designed for rapid and accurate measurement of various soil parameters. This device is essential for scientific planting, agricultural cultivation, scientific research, and soil improvement applications.

Figure 1: Yieryi YG-09S 9-in-1 Soil Tester
Key Features:
- Measures 9 vital soil parameters: Nitrogen (N), Phosphorus (P), Potassium (K), pH, Electrical Conductivity (EC), Moisture, Temperature, Salinity, and Comprehensive Fertility.
- Split-type design with a 2-meter cable for flexible testing and easy data reading.
- Supports both Manual and Automatic measurement modes.
- Stores up to 12 sets of measurement records, with a delete function.
- Automatic shutdown function (can be disabled).
- Large LCD display with switchable backlight for clear readability.
- Built-in rechargeable 3.7V/500mAh lithium battery with Type-C charging port.
- Durable 4-needle stainless steel NPK sensor probe, corrosion-resistant and bend-resistant.

Figure 2: Overview of product features and capabilities.
2. Product Components and Display
Split-Type Design:
The YG-09S features a split-type design where the main unit and the probe are separated, connected by a 2-meter cable. This allows for easier testing in various environments and comfortable reading of data.

Figure 3: Split-type design in use, showing the probe connection with a metal knob.
Main Unit and Probe Diagram:

Figure 4: Main Unit and Probe Diagram with labeled parts.
LCD Display Symbols:
- REC: Save record symbol
- 1-12: Record number
- pH, NPK, EC, st, ft, Temp, Humidity: Measurement parameter display
- °C/°F: Temperature unit symbol
- %: Humidity unit symbol
- mg/kg, us/cm, g/kg: N, P, K, EC, Salinity unit symbols
- Battery Icon: Battery level symbol
- APO: Automatic shutdown symbol
- Backlight Icon: Backlight symbol
- AUTO: Automatic measurement mode symbol
Button Functions:
- POWER Button: Power switch / Backlight switch.
- OK Button: Manual measurement, save record, view records.
- AUTO Button: Automatic measurement mode.
- APO Button: Cancel automatic shutdown / View 12 groups of records downward.
- °C/°F Button: Temperature unit conversion / Long press to delete saved records.
- Left/Right Arrow Buttons: Check parameters (left/right).
3. Setup and Initial Use
- Connect the Probe: Carefully plug the probe cable into the sensor connection socket on the main unit. Ensure the metal knob connector is securely fastened to prevent loosening.
- Power On: Press and hold the POWER button for 2 seconds to turn on the device.
- Initial Auto-Off Setting: Upon powering on, the device defaults to Automatic Power Off (APO) mode, which will shut down the device after 10 minutes of inactivity. To disable this, briefly press the APO button (the APO symbol on the screen will disappear).
- Backlight Control: The backlight automatically turns on with the device and turns off after 3 minutes. You can manually toggle the backlight by briefly pressing the POWER button.
Important Note:
Before using the product, please read this manual carefully and familiarize yourself with the operation. Keep this manual for future reference.
4. Operating Instructions
4.1 Taking a Measurement
- Prepare the Soil: If the soil is too dry, moisten it with water before testing. This prevents damage to the probe and ensures accurate readings.
- Insert the Probe: Insert the probe vertically into the soil. Avoid hitting stones or hard objects.
- Select Measurement Mode:
- Manual Mode (Default): The screen displays "0", and data does not refresh automatically. Press the OK button to initiate a single measurement. The current reading will be automatically saved (REC flashes three times). This mode is suitable for fixed-point sampling.
- Automatic Mode: Press and hold the AUTO button to enter this mode. The screen will display the "AUTO" symbol. All parameters will update automatically in real-time. Briefly press the OK button to save the current data. To exit Automatic Mode, press and hold the AUTO button again.
- Read the Data: Observe the readings on the large LCD display.

Figure 5: Manual vs. Automatic Measurement Modes.
4.2 Viewing and Deleting Records
- View Records: Press and hold the OK button to enter record viewing mode. The latest record number will be displayed. Use the Left/Right Arrow buttons to scroll through different parameters within a record, and the APO (down arrow) button to switch between record groups (up to 12 sets).
- Delete All Records: While NOT in record viewing mode, press and hold the °C/°F button for 2 seconds. When the number "0" flashes three times, all records have been successfully deleted.
- Note: The device can store up to 12 sets of records. If there are no records, pressing and holding the OK button will not enter viewing mode.

Figure 6: Data Storage and Retrieval.
4.3 Temperature Unit Conversion
Briefly press the °C/°F button to switch the temperature display between Celsius (°C) and Fahrenheit (°F).
4.4 Power Off
Press and hold the POWER button for 2 seconds to turn off the device. Remember to remove the probe from the soil after use.
5. Measurement Recommendations
- Soil Moisture: If the soil is too dry before testing, please water it first to moisten it. This prevents damage to the probe from forcing it into dry, hard soil and ensures more accurate readings.
- Multiple Readings: For more accurate results, take multiple measurements at different spots within the testing area and calculate the average.
- pH Measurement: For pH measurements, the probe must be inserted into the soil for at least 3 minutes. Read the value only once it has stabilized.
- Avoid Hard Surfaces: Do not use the probe on stones, hard surfaces, or in extremely compact soil without prior moistening, as this can damage the probe.
6. Technical Specifications

Figure 7: Technical Specifications Table.
| Item | Parameter |
|---|---|
| Measurement Range | Temperature: -30~+80°C (-22~176°F) |
| Humidity: 0~100% | |
| Acidity and alkalinity (PH): 2.0~10.5 | |
| Nitrogen(N): 0~1005mg/kg | |
| Phosphorus(P): 0~1387mg/kg | |
| Potassium(K): 0~1999mg/kg | |
| Electrical Conductivity (EC): 0~8000us/cm | |
| Salinity(st): 0~6000mg/Kg | |
| Comprehensive fertility (ft): 0~100 | |
| Measurement Accuracy and Resolution | Temperature: Accuracy ±0.5°C, Resolution 0.1°C |
| Humidity: Accuracy ±2%, Resolution 0.1% | |
| PH: Accuracy ±0.5, Resolution 0.1 | |
| Nitrogen(N): Accuracy ±2%, Resolution 1.0 | |
| Phosphorus(P): Accuracy ±2%, Resolution 1.0 | |
| Potassium (K): Accuracy ±2%, Resolution 1.0 | |
| Electrical Conductivity (EC): Accuracy ±2%, Resolution 1.0 | |
| Salinity(st): Accuracy ±2%, Resolution 1.0 | |
| Comprehensive fertility (ft): Accuracy ±5, Resolution 1.0 | |
| Ambient Temperature | -10.0~50.0°C (14.0~122.0°F) ±1.0°C/°F |
| Operating Environment | -10~50°C, 20~90%RH |
| Storage Environment | -10~60°C, 20~90%RH |
| Battery | Rechargeable lithium battery 3.7V/500mAh |
| Host Dimensions | 155x61x31mm |
| Probe Dimensions | 165x50.5x20.5mm (including probe pin) |
| Cable Length | 2.0m |
Soil Fertility Guidelines:
Soil fertility is crucial for plant growth, encompassing physical, chemical, and biological aspects. Different crops have varying fertility requirements. Managing and adjusting soil fertility based on measurements helps meet crop needs and promotes sustainable agricultural production.

Figure 8: Soil Parameter Ranges.
| Parameter | Optimal Range (Reference for Most Plants) |
|---|---|
| Temperature | 15~25°C (59~86°F) |
| Humidity | 50~60% |
| pH | 6.0~7.0 |
| Nitrogen (N) | 30~200mg/kg |
| Phosphorus (P) | 20-100mg/kg |
| Potassium (K) | 50~300mg/kg |
| Electrical Conductivity (EC) | 300~1500us/cm |
| Salinity | <2000mg/kg |
| Comprehensive Fertility | 55-85 |
Note: Different plants have different needs; adjust soil conditions according to the specific crop.
7. Care and Maintenance
- Probe Cleaning: After each use, clean the probe with fresh water and wipe it dry with a soft cloth. Do not submerge the probe in water for extended periods.
- Avoid Certain Materials: Do not use the probe to test liquids, flour, sawdust, or similar substances.
- Handling: Avoid dropping, crushing, or exposing the device to high temperatures or corrosive liquids.
- Storage: If the device will not be used for an extended period, fully charge it before storing. Recharge it once every 3 months to maintain battery health.
- Battery Drain: Unplug the probe cable from the main unit after testing to prevent unnecessary battery drain.

Figure 9: Durable Metal Probe.

Figure 10: Type-C Charging Port and LCD Display.
8. Troubleshooting (FAQ)
- Q1: Why does the screen display "0" after turning on the device?
- A: This is normal and indicates the device is in Manual Mode. Insert the probe into the soil and press the OK button to start measuring.
- Q2: Why are the measured values fluctuating or unstable?
- A: This often occurs when the soil is uneven or too dry. Please moisten the soil and take multiple measurements at different spots to get an average for more stable results.
- Q3: Why can't I save any new measurement records?
- A: Check if the memory has reached its maximum capacity of 12 sets. If full, long press the °C/°F button for 2 seconds (when not in viewing mode) to delete historical records, then try again.
- Q4: Why is the Automatic Power Off (APO) function not working?
- A: Check if the "APO" symbol is displayed on the screen. If it's not visible, briefly press the APO button to reactivate it.
- Q5: Why is there no response when connecting the charging cable?
- A: Ensure you are using a standard 5V/1A adapter with a Type-C cable. For safety, it is highly recommended to unplug the probe cable while charging.
- Q6: What does it mean when the battery symbol appears on the screen?
- A: This indicates a low battery level. To ensure data accuracy and continuous operation, please recharge the device promptly using the Type-C port.
- Q7: What is the difference between Manual and Automatic modes?
- A: In Manual Mode, you press the OK button to lock and save a single reading. In Automatic Mode, you press and hold the AUTO button until the "AUTO" symbol appears, providing real-time updates of all parameters.
- Q8: How should I maintain the 4-needle metal probe?
- A: The probe is made of corrosion-resistant stainless steel. Always clean it with fresh water and wipe it dry with a soft cloth after use. Never leave it inserted in the soil long-term.
9. User Tips
- Optimal Soil Preparation: Always ensure the soil is adequately moist before inserting the probe. Dry or hard soil can lead to inaccurate readings and potential probe damage.
- Consistent Readings: For critical measurements like pH, allow the probe to stabilize in the soil for the recommended 3 minutes to get the most consistent and reliable results.
- Data Tracking: Utilize the 12-set data storage feature to track changes in your soil's health over time. This can help in identifying trends and optimizing fertilization schedules.
- Charging Best Practice: When charging, always use a 5V/1A adapter and a Type-C cable. For safety and to prevent any interference, it's best to unplug the probe cable from the main unit during charging.
10. Packing List
The following items are included in your YG-09S Soil Tester package:
- 1 x YG-09S 9-in-1 Soil Tester (Main Unit)
- 1 x 2M NPK Sensor Probe
- 1 x Carry Box
- 1 x User Manual (this document)

Figure 11: Contents of the YG-09S package.
Packaging Specifications:

Figure 12: Packaging Specifications.
| Individual Packaging Specifications | Carton Packaging Specifications |
|---|---|
| Weight: 730g | Weight: 15.6kg |
| Quantity: 1pcs | Quantity: 20pcs |
| Packaging dimensions: 24*19.5*8cm | Packaging dimensions: 50.5*43.5*42cm |
11. Warranty and Support
The company reserves the right to update the product and user manual without prior notice. Please dispose of used batteries in accordance with local regulations.
For technical support, please contact your point of purchase or visit the official Yieryi website: www.yieryi.com
Manual Version: V2.0
Release Date: May 29, 2026
A PDF version of this user manual is available for download. Please refer to the seller's product page or official website for the link.