yieryi YG-09S

Contents

YIERYI 9-in-1 Soil Tester YG-09S User Manual

Model: YG-09S | Brand: YIERYI

1. Introduction

The YIERYI YG-09S is a multifunctional soil parameter analyzer designed for precise and rapid measurement of various soil health metrics. This revolutionary 9-in-1 split-type soil detector is equipped with a high-precision 4-pin metal probe and a smart low-power chip, providing real-time, laboratory-grade data tracking for 9 critical soil health metrics. It is suitable for agricultural cultivation, scientific research, soil improvement, and other applications.

YIERYI YG-09S 9-in-1 Soil Tester with probe inserted into soil
The YIERYI YG-09S Soil Tester in use, demonstrating its split-type design.

Key Features:

  • 9-in-1 Full-Scale Detection: Measures Soil Temperature, Humidity, PH (Acidity/Alkalinity), Nitrogen (N), Phosphorus (P), Potassium (K), Electrical Conductivity (EC), Salinity (st), and Comprehensive Fertility (ft) in one single device.
  • Advanced Split-Body Design: Features a modular handheld host connected to a heavy-duty 4-pin sensor via a 2.0-meter cable. This allows for easy readings in deep soil or hard-to-reach areas without spacing limits.
  • Eco-Friendly Type-C Rechargeable: Built-in 3.7V/500mAh lithium battery with a low-power chip ensures long-lasting operation, eliminating the need for constant battery replacements.
  • Smart Data Storage (12 Sets): Press and hold the OK button to save and review up to 12 groups of historical data records, enabling monitoring of soil property changes over time.
  • Dual Measurement Modes: Switch between Manual Mode (saves current reading instantly) and Automatic Mode (updates all values in real-time on the screen).
  • Large Backlit LCD Display: Provides a clear digital readout with a switchable green backlight, making it effortless to read under direct sunlight or in dark environments.

2. Package Contents

Upon opening the package, please verify that all items listed below are present and in good condition.

YIERYI YG-09S Soil Tester, carry case, and user manual
The YG-09S Soil Tester kit, including the main unit, probe, carry case, and user manual.
YG-09S Packing List
ItemQuantity
Soil Tester (Main Unit + Probe)1
Carry Case1
User Manual1

3. Product Overview

Familiarize yourself with the components and controls of your YIERYI YG-09S Soil Tester.

Labeled diagram of the YIERYI YG-09S Soil Tester main unit and probe
Detailed diagram of the YG-09S Soil Tester with labeled parts and dimensions.

Main Components:

  • Main Unit (Host): Contains the LCD display, control buttons, and battery.
  • Probe: The sensor unit with four metal pins for insertion into the soil.
  • Sensor Connector: Connects the probe cable to the main unit.
  • LCD Display: Digital screen showing measurement parameters, battery level, and mode indicators.
  • Power Key/Backlight Key: Used to power the device on/off and control the backlight.
  • OK Button: Used to initiate manual measurements, save records, and enter record viewing mode.
  • AUTO Button: Used to switch between manual and automatic measurement modes.
  • APO Button: Used to enable/disable the automatic shutdown function.
  • °C/°F Button: Used to switch temperature units and delete saved records (long press).

4. Technical Specifications

Below are the detailed technical specifications for the YIERYI YG-09S Soil Tester.

Table of technical specifications for YIERYI YG-09S Soil Tester
Comprehensive technical specifications including measurement ranges, accuracy, and environmental conditions.
ItemParameter
Measurement Range
Temperature-30~+80°C (-22~176°F)
Humidity0~100%
Acidity and alkalinity (PH)2.0~10.5
Nitrogen(N)0~1005mg/kg
Phosphorus(P)0~1387mg/kg
Potassium(K)0~1999mg/kg
Electrical Conductivity (EC)0~8000us/cm
Salinity(st)0~6000mg/Kg
Comprehensive fertility (ft)0~100
Measurement Accuracy and Resolution
TemperatureAccuracy ±0.5°C, Resolution 0.1°C
HumidityAccuracy ±2%, Resolution 0.1%
PHAccuracy ±0.5, Resolution 0.1
Nitrogen(N)Accuracy ±2%, Resolution 1.0
Phosphorus(P)Accuracy ±2%, Resolution 1.0
Potassium(K)Accuracy ±2%, Resolution 1.0
Electrical Conductivity (EC)Accuracy ±2%, Resolution 1.0
Salinity(st)Accuracy ±2%, Resolution 1.0
Comprehensive fertility (ft)Accuracy ±5, Resolution 1.0
Environmental Conditions
Ambient temperature-10.0~50.0°C (14.0~122.0°F) ±1.0°C/°F
Operating environment-10~50°C, 20~90%RH
Storage environment-10~60°C, 20~90%RH
Power & Dimensions
BatteryRechargeable lithium battery 3.7V/500mAh
Host Dimensions155mm x 61mm x 31mm
Probe Dimensions165mm x 50.5mm x 20.5mm (including probe pin)
Cable Length2.0m

5. Quick Setup Guide

Follow these steps to quickly get your soil tester ready for use.

  1. Connecting the Probe: Plug the probe cable securely into the sensor connector on the main unit. Ensure a firm connection.
  2. Switching On: Press and hold the POWER button for 2 seconds to turn on the device. The LCD display will light up.
  3. Initial Measurement: Insert the probe vertically into the soil. The soil should be moist; avoid inserting into hard objects or stones.
  4. Reading: In manual mode, press the OK button to start a measurement. In automatic mode, data will refresh automatically.
  5. Switching Off: Press and hold the POWER button for 2 seconds to turn off the device. Remove the probe from the soil.

6. Detailed Operation Instructions

6.1 Power On/Off

  • To switch the device on or off, press and hold the POWER button for 2 seconds.
  • Upon powering on, the device defaults to Automatic Shutdown (APO) mode. If no operation is performed for 10 minutes, the device will automatically shut down.
  • To disable automatic shutdown, briefly press the APO button. The APO symbol on the screen will disappear.

6.2 Backlight Control

  • The backlight automatically turns on when the device is switched on and turns off automatically after 3 minutes.
  • To manually switch the backlight on or off, briefly press the POWER button.

6.3 Measurement Modes

Manual and Automatic measurement modes of the YIERYI YG-09S Soil Tester
Demonstration of Manual and Automatic measurement modes.

Manual Mode (Default)

  • In this mode, the screen displays '0', and data does not refresh automatically.
  • Press the OK button to initiate a single measurement. The current reading will be automatically saved (REC flashes three times). This mode is suitable for fixed-point sampling.

Automatic Mode

  • To enter Automatic Mode, press and hold the AUTO button. The screen will display the 'AUTO' symbol.
  • In this mode, all parameters are updated automatically in real-time.
  • To save the current data, briefly press the OK button.
  • To exit Automatic Mode, press and hold the AUTO button again.

6.4 Viewing and Deleting Records

YIERYI YG-09S Soil Tester displaying stored data records
The device displaying stored measurement data, with options to scroll through parameters.

Viewing Records

  • To enter record viewing mode, press and hold the OK button. The latest record number will be displayed.
  • Use the ◀ (left arrow) and ▶ (right arrow) buttons to switch between different record groups.
  • Use the ▲ (up arrow) and ▼ (down arrow) buttons to view different parameters within a selected record.
  • The device can store up to 12 sets of records. If there are no records, pressing and holding the OK button will not enter view mode.

Deleting Records

  • To delete all stored records, ensure the device is not in record viewing mode.
  • Press and hold the °C/°F button for 2 seconds. When the number '0' flashes three times, all records have been successfully deleted.

6.5 Temperature Unit Switching

  • To switch between Celsius (°C) and Fahrenheit (°F) temperature units, briefly press the °C/°F button.

7. Measurement Recommendations

For optimal accuracy and to ensure the longevity of your device, please follow these recommendations:

  • Soil Preparation: If the soil is too dry before testing, please water it first to moisten it. This prevents damage to the probe from forcing it into hard, dry soil.
  • Multiple Readings: Take multiple readings from different spots and calculate the average for more accurate results, especially if the soil composition is uneven.
  • pH Measurements: For accurate pH measurements, the probe must be inserted into the soil for at least 3 minutes. Read the value only once it has stabilized.
  • Probe Usage: Avoid using the probe on stones, hard surfaces, or in highly compacted soil to prevent bending or damage to the pins.

7.1 Soil Fertility Guidelines

Soil fertility refers to the soil's ability to continuously and simultaneously supply and balance the water, nutrients, air, heat, and other environmental conditions required by plants. It comprises three aspects: physical fertility, chemical fertility, and biological fertility, which are closely interrelated and indispensable.

Different crops have different requirements for soil fertility. By managing and adjusting soil fertility, you can better meet the needs of crop growth and achieve sustainable agricultural production.

Comprehensive Fertility Range Guidelines
Comprehensive Fertility Range (ft)Level
0~20Very Poor
20~50Poor
50~75Average
75~90Good
90~100Excellent

7.2 Optimal Parameter Ranges for Most Plants (Reference)

The table below provides general reference ranges for various soil parameters suitable for most plants. Remember that different plants have specific needs, so adjust your soil management according to the particular crop you are growing.

Optimal Soil Parameter Ranges
ParametersRange
Temperature15~25°C (59~86°F)
Humidity50~60%
PH6.0~7.0
Nitrogen (N)30~200mg/kg
Phosphorus (P)20-100mg/kg
Potassium (K)50~300mg/kg
Electrical Conductivity (EC)300~1500us/cm
Salinity<2000mg/kg
Comprehensive fertility55-85

8. Precautions and Maintenance

  • Probe Care: Do not submerge the probe in water for extended periods. Do not use it to test liquids, flour, sawdust, or similar substances.
  • Cleaning: Always wipe the probe with a dry cloth after each use to keep it clean and prevent residue buildup.
  • Handling: Avoid dropping, crushing, or exposing the device to high temperatures or corrosive liquids.
  • Long-Term Storage: If the device will not be used for an extended period, fully charge it before storing. Recharge it once every 3 months to maintain battery health.
  • Battery Drain: Unplug the probe after testing to prevent unnecessary battery drain.

9. Frequently Asked Questions (FAQ)

Q: Why does it show '0' after switching on?
A: In manual mode, you need to press the OK button to start measuring.
Q: Why are the readings fluctuating so much?
A: This can happen if the soil is uneven or not sufficiently moist. Take several measurements and calculate the average for more stable results.
Q: I am unable to save the record.
A: Check whether the 12-entry limit for records has been reached. If so, delete historical records and try again.
Q: The automatic shutdown is not working.
A: Check whether the APO symbol is displayed on the screen. If not, briefly press the APO button to re-enable the function.
Q: There is no response when charging.
A: Ensure you are using a 5V/1A adapter and a Type-C cable. It is recommended to disconnect the probe while charging.
Q: The screen displays a battery symbol.
A: This indicates that the battery is low. Please charge the device as soon as possible.

10. After-Sales Service and Support

The company reserves the right to update the product and user manual without prior notice. Please refer to the latest version for the most accurate information.

  • Battery Disposal: Please dispose of used batteries in accordance with local regulations.
  • Technical Support: For technical assistance, please contact your point of purchase or visit our official website: www.yieryi.com
  • Manual Version: V2.0
  • Release Date: May 29, 2026

For a comprehensive guide and additional details, you may refer to the official User Manual PDF: YIERYI YG-09S User Manual (PDF)

© 2024 YIERYI. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.