ANENG M126

Contents

ANENG M126 Digital Multimeter User Manual

High Precision Contactless Sensing AC/DC Voltage Multimeter

1. Introduction

The ANENG M126 is a professional digital multimeter designed for accurate and safe electrical measurements. Featuring auto-ranging capabilities and non-contact voltage (NCV) sensing, it is suitable for both beginners and experienced users for various applications including experimental measurement, electric box maintenance, DIY learning, and automotive inspection.

This manual provides essential information for the safe and effective operation, maintenance, and troubleshooting of your ANENG M126 Digital Multimeter.

2. Safety Information

Always observe safety precautions when using electrical testing equipment to prevent personal injury or damage to the instrument.

  • Do not touch the probes directly with your hands during testing to avoid electric shock.
  • Before each use, inspect the test probes for any damaged insulation or exposed metal. Replace damaged probes immediately.
  • Do not use the current and voltage ranges interchangeably. Incorrect range selection can damage the instrument.
  • If the magnitude of the voltage or current to be measured is unknown, always start with the highest available range and then adjust to an appropriate lower range based on the measured value.
  • Remove batteries if the instrument will not be used for an extended period to prevent battery leakage and corrosion.

3. Product Overview

3.1 Components and Features

The ANENG M126 Digital Multimeter is designed with user-friendly features and a durable build.

ANENG M126 Digital Multimeter front view with features
Figure 1: Front view of the ANENG M126 Digital Multimeter highlighting key features like non-contact sensing, auto shutdown, automatic range, and 6000 count display.
ANENG M126 Product Parameters Diagram
Figure 2: Product parameters diagram showing dimensions and labeled parts of the multimeter.
  1. LCD Backlit Screen: Displays measurements clearly, even in low-light conditions.
  2. Data Retention / Screen Backlighting: Press the 'HOLD' button to freeze the current reading on the display.
  3. Function Switching / Shutdown: The 'SEL' button cycles through functions, and a long press powers the device on/off.
  4. Switch NCV/Zero Live Wire / Turn on Flashlight: The 'N/L' button activates NCV mode and also controls the built-in flashlight.
  5. COM Input Jack: Common terminal for test leads (black probe).
  6. INPUT Jack: Input terminal for measurements (red probe).
  7. Flashlight: Built-in light for illuminating dark work areas.
  8. Silicone Sheath: Provides anti-drop protection and enhances durability.
  9. Battery Compartment: Located on the back for battery installation.

3.2 Package Contents

Upon opening your ANENG M126 package, you should find the following items:

ANENG M126 Accessories List
Figure 3: Visual representation of the ANENG M126 Multimeter and its accessories.
  • 1 x ANENG M126 Digital Multimeter
  • 1 x Packing Box
  • 1 x Pair of Test Leads (Pen Line)
  • 1 x Instruction Manual (this document)

Note: Batteries are not included in the package.

4. Setup

4.1 Battery Installation

The ANENG M126 Multimeter requires two 1.5V AAA batteries for operation.

ANENG M126 Battery Compartment
Figure 4: View of the battery compartment on the back of the multimeter.
  1. Locate the battery compartment cover on the back of the multimeter.
  2. Use a screwdriver to open the battery compartment.
  3. Insert two 1.5V AAA batteries, ensuring correct polarity (+ and -).
  4. Close the battery compartment cover and secure it with the screw.

5. Operating Instructions

5.1 Power On/Off

Press and hold the 'SEL' button to power on or power off the multimeter.

5.2 Automatic Identification (Auto Range)

The M126 features full auto-identification, meaning it automatically detects the measurement type (AC/DC voltage, resistance, capacitance, diode, continuity) and selects the appropriate range. This simplifies operation, especially for beginners.

5.3 AC Voltage Measurement

ANENG M126 AC Voltage Test
Figure 5: Measuring AC voltage with the ANENG M126 Multimeter.

To measure AC voltage:

  1. Insert the red test lead into the 'INPUT' jack and the black test lead into the 'COM' jack.
  2. Touch the probes to the points where you want to measure AC voltage. The multimeter will automatically identify the AC voltage and display the reading.

5.4 DC Voltage Measurement

ANENG M126 DC Voltage Measurement
Figure 6: Measuring DC voltage, typically across a battery.

To measure DC voltage:

  1. Insert the red test lead into the 'INPUT' jack and the black test lead into the 'COM' jack.
  2. Touch the probes to the positive and negative terminals of the DC source. The multimeter will automatically identify the DC voltage and display the reading.

5.5 Resistance Measurement

ANENG M126 Resistance Measurement
Figure 7: Measuring resistance of a component.

To measure resistance:

  1. Insert the red test lead into the 'INPUT' jack and the black test lead into the 'COM' jack.
  2. Touch the probes to the two ends of the resistor or circuit component. The multimeter will automatically identify the resistance and display the reading.

5.6 Capacitance Measurement

ANENG M126 Capacitance Measurement
Figure 8: Measuring capacitance. Ensure capacitors are discharged before testing for safety.

To measure capacitance:

  1. Insert the red test lead into the 'INPUT' jack and the black test lead into the 'COM' jack.
  2. For safety reasons, ensure the capacitor is fully discharged before measurement.
  3. Touch the probes to the terminals of the capacitor. The multimeter will automatically identify the capacitance and display the reading.

5.7 Diode Test

ANENG M126 Diode Test
Figure 9: Performing a diode test to check its functionality and polarity.

To perform a diode test:

  1. Insert the red test lead into the 'INPUT' jack and the black test lead into the 'COM' jack.
  2. Touch the probes to the anode and cathode of the diode. The multimeter will automatically recognize the diode gear and display the forward voltage drop. Reverse the probes to check for open circuit.

5.8 Continuity (On-Off Beep) Test

ANENG M126 Continuity Test
Figure 10: Performing a continuity test, indicated by an audible beep.

To perform a continuity test:

  1. Insert the red test lead into the 'INPUT' jack and the black test lead into the 'COM' jack.
  2. Touch the probes to the two points of the circuit you want to test for continuity. An audible beep indicates a continuous circuit (low resistance).

5.9 NCV (Non-Contact Voltage) Measurement

ANENG M126 NCV Measurement
Figure 11: Using the NCV feature to detect AC voltage without direct contact.

To use NCV mode:

  1. Press the 'N/L' button to switch to NCV mode.
  2. Bring the top of the multimeter close to the wire or outlet. When AC voltage is detected, a beep alarm will sound, and the display will show a signal strength indicator. This provides a safer way to detect live wires.

5.10 Naught FireWire (Live/Neutral Wire) Measurement

ANENG M126 Naught FireWire Measurement
Figure 12: Detecting live and neutral lines using the Naught FireWire feature.

In Live mode (activated by pressing 'N/L' button):

  1. Touch the red probe to the wire. If it's a live line, the screen will show 'LIVE' and beep.
  2. If it's a neutral line, there will be no beep and the screen will show 'NAUGHT'.

5.11 Current Measurement (Important Safety Warning)

Incorrect Current Measurement
Figure 13: WARNING: Incorrect method of current measurement. Direct contact with voltage sources will burn out the instrument.
Correct Current Measurement
Figure 14: Correct method of current measurement. The multimeter must be connected in series with the circuit.

Current measurements require the multimeter to be connected in series with the circuit. DO NOT directly contact the probes to a voltage source (like an outlet) when measuring current, as this will damage the instrument and pose a safety risk.

5.12 Other Functions

  • Data Hold: Press the 'HOLD' button to freeze the current reading on the display. Press again to release.
  • Flashlight: Press the 'N/L' button briefly to turn the flashlight on or off.
  • Automatic Shutdown: The multimeter will automatically shut down after approximately 15 minutes of inactivity to conserve battery life.
  • Low Power Prompt: An icon on the display will indicate when the batteries are low and need replacement.

6. Maintenance

6.1 Cleaning

Wipe the multimeter casing with a soft, damp cloth. Do not use abrasive cleaners or solvents. Ensure the device is powered off and disconnected from any circuits before cleaning.

6.2 Battery Replacement

When the low power indicator appears on the display, replace the batteries as described in Section 4.1. Always use two new 1.5V AAA batteries.

6.3 Storage

If the multimeter is not used for a long period, remove the batteries to prevent leakage. Store the device in a cool, dry place, away from direct sunlight and extreme temperatures.

7. Troubleshooting

  • No Display/Faint Display: Check battery installation and charge level. Replace batteries if necessary.
  • Incorrect Readings: Ensure test leads are properly connected and not damaged. Verify the correct measurement mode is selected (though auto-ranging should handle most cases). Ensure good contact with the circuit.
  • No Beep in Continuity Mode: Check if the circuit is truly continuous. Ensure probes are making good contact.
  • NCV Not Detecting: Ensure NCV mode is active. The sensor needs to be close to the AC voltage source.

For persistent issues, refer to the detailed user manual PDF or contact customer support.

8. Specifications

8.1 General Specifications

  • Brand Name: ANENG
  • Model Number: M126
  • DIY Supplies: Electrical
  • Display Type: Digital Display
  • Operating Mode: Auto Range
  • Operating Temperature: 0 - 40 ℃
  • Maximum Count: 6000 Count
  • Material: ABS+Silicone
  • Net Weight: 112g
  • Battery: 2 x 1.5V AAA batteries (not included)
  • Certification: CE
  • Origin: Mainland China
  • Data Record: No
  • Is Smart Device: No
  • Semi-finished product: No
  • High-concerned chemical: None

8.2 Measurement Ranges and Precision

ANENG M126 Function and Range Table
Figure 15: Detailed table of M126 function, range, resolution, and precision.
FunctionRangeResolutionPrecision
DC Voltage0.2V~600V0.8V±(0.8%+5word)
AC Voltage0.2V~600V0.8V±(1.0%+5word)
Capacitor0.1μF~200μF0.1μF±(4.0%+5word)
Resistance0Ω~40MΩ1Ω±(0.8%+5word)
On-Off Beep√Automatic shutdownAfter 15 minutes
Diode√Battery model1.5V AAA battery*2
NCV Voltage Sensing√Automatic identification√
Naught FireWire√Data retention√
LCD Backlit Screen√
Flashlight Lighting√
Low Power Prompt√

8.3 Manual Mode Indicator Range

ANENG M126 Manual Mode Indicator Range Table
Figure 16: Table showing manual mode indicator ranges for DC and AC voltage.
FunctionRangeResolutionPrecision
DC Voltage0.010V~600V0.01V±(0.8%+5)
AC Voltage0.1V~600V0.1V±(1.0%+5)

Note: The parameters are for reference only, and the actual measurement of the specific equipment shall prevail.

9. User Tips

Based on user feedback, the ANENG M126 Multimeter is generally regarded as a reliable and good quality product. Its ease of use, particularly the auto-ranging feature, makes it a convenient tool for various electrical tasks.

  • Take advantage of the auto-ranging feature for quick and hassle-free measurements.
  • The NCV function is highly useful for initial safety checks before touching wires.
  • Remember to connect the multimeter in series for current measurements to avoid damage.

10. Warranty & Support

For detailed warranty information and customer support, please refer to the official ANENG website or the seller's terms and conditions. A comprehensive user manual in PDF format is available for download: ANENG M126 User Manual (PDF).

11. Product Video

Play video
Watch video online

Video: ANENG M126 Smart Multimeter product demonstration, showcasing its features and use cases.


Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.