1. Introduction
The LCTC Voltage Protector is a multi-function device designed to safeguard electrical equipment from damage caused by voltage fluctuations (overvoltage and undervoltage) and overcurrent conditions. It features a digital display for real-time monitoring of voltage, current, and (for model LC-AVP-3) accumulated energy consumption (kWh). This device is designed for easy installation on a DIN rail and offers adjustable protection parameters and automatic reclosing functionality.
2. Safety Information
WARNING: Electrical shock hazard. Installation and maintenance should only be performed by qualified personnel.
- Ensure the power supply is completely disconnected before installation or wiring.
- Verify all connections are secure and correct according to the wiring diagram.
- Do not operate the device if it is damaged or malfunctioning.
- This device is designed for low voltage applications (below 50Vac or 75Vdc) in the EU LVD Voltage standard.
3. Product Components and Display
The LCTC Voltage Protector features a clear digital display and intuitive control buttons:
- Voltage Display (V): Shows the current line voltage.
- Current Display (A): Shows the current load.
- kWh Display (kWh): (LC-AVP-3 model only) Shows accumulated energy consumption.
- SET Button: Enters parameter setting mode.
- Digit "+" (Up Arrow): Increases parameter values or navigates menus.
- Digit "-" (Down Arrow): Decreases parameter values or navigates menus.
- ON/OFF Button: Manually switches the output on or off.
- IN Terminals (N, L): Power input terminals.
- OUT Terminals (N, L): Power output terminals to the load.
4. Specifications
| Parameter | Value |
|---|---|
| Operating Voltage | AC80-300V |
| Rated Supply Voltage | AC80-300V |
| Rated Frequency | 50-60Hz (or 35/75Hz) |
| Overvoltage Range (>V) | AC130-300V |
| Undervoltage Range (<V) | AC80-210V |
| Current Range | 1-40A / 1-63A (depending on model) |
| Max Rated Current | 40A / 63A (depending on model) |
| Power-off Delay Range | 1-60S |
| Power Failure Recovery Time Range | 1-60S |
| Voltage Correction Value | -99-99V |
| Current Correction Value | -9.9-9.9A |
| Overcurrent Power Failure Delay Range | 1-30S |
| Working Indicator | Green (Normal), Red (Fault) |
| Certification | CE |
Note: There may be a measurement error of 1-3mm in physical dimensions.
5. Installation and Wiring
The LCTC Voltage Protector is designed for DIN rail mounting.
5.1 Mounting
Snap the device onto a standard 35mm DIN rail in your electrical panel. Ensure it is securely fastened.
5.2 Wiring Diagram
Connect the device according to the following diagram. Ensure proper polarity (Neutral 'N' and Live 'L') for both input and output terminals.
- Connect the incoming Neutral (N) and Live (L) wires from your power source to the 'IN' terminals of the protector.
- Connect the outgoing Neutral (N) and Live (L) wires from the 'OUT' terminals of the protector to your load (e.g., light bulb, appliance).
- It is recommended to install an appropriate circuit breaker upstream of the voltage protector for additional safety and circuit protection.
6. Operating Instructions
6.1 Power On and Display
Once wired correctly and power is supplied, the device will power on and display real-time voltage and current. If you have the LC-AVP-3 model, it will also display accumulated kWh.
6.2 Setting Protection Parameters
The device offers adjustable parameters for overvoltage, undervoltage, overcurrent, and trip/recovery times. The video below demonstrates some of these functions.
- Enter Setting Mode: Press and hold the "SET" button for a few seconds until the display changes to parameter setting mode.
- Navigate Parameters: Use the "+" (Up) and "-" (Down) buttons to cycle through different parameters (e.g., overvoltage threshold, undervoltage threshold, overcurrent threshold, trip delay, recovery delay, voltage/current correction).
- Adjust Values: When the desired parameter is displayed, use the "+" and "-" buttons to adjust its value.
- Save Settings: Press the "SET" button again to confirm the value and move to the next parameter, or wait for a few seconds for the device to automatically save and exit setting mode.
6.3 Protection Functions
- Overvoltage Protection: If the voltage exceeds the set overvoltage threshold, the device will trip and cut off power to the load. The display will indicate an overvoltage fault.
- Undervoltage Protection: If the voltage drops below the set undervoltage threshold, the device will trip and cut off power to the load. The display will indicate an undervoltage fault.
- Overcurrent Protection: If the current drawn by the load exceeds the set overcurrent threshold, the device will trip and cut off power. The display will indicate an overcurrent fault.
- Automatic Reclosing: After a trip event (overvoltage, undervoltage, or overcurrent), the device will automatically attempt to reclose and restore power after a set recovery delay, provided the fault condition has cleared.
- Manual Switch: The ON/OFF button allows for manual interruption or restoration of power. If the device has tripped due to a fault, you can manually resume operation using this button once the fault is resolved.
7. Maintenance
- Keep the device clean and free from dust and moisture.
- Periodically check wiring connections for tightness and signs of wear or corrosion.
- Ensure adequate ventilation around the device to prevent overheating.
- Do not attempt to open or repair the device yourself. Refer to qualified service personnel.
8. Troubleshooting
- Device does not power on:
- Check the incoming power supply and ensure all wiring connections are correct and secure. Verify the upstream circuit breaker is not tripped.
- Device trips frequently:
- Check the display for the fault type (overvoltage, undervoltage, or overcurrent). Adjust the protection thresholds if they are set too sensitively for your application. Ensure your load does not exceed the device's maximum rated current.
- Incorrect voltage/current readings:
- You can use the voltage/current correction parameters in the setting mode to fine-tune the readings if you have a calibrated reference meter.
- Automatic reclosing does not work:
- Ensure the fault condition has cleared. Check the recovery delay setting; if it's too long, it might appear as if it's not reclosing. If the fault persists, the device will not reclose.
9. User Tips
- Before setting parameters, familiarize yourself with your local power grid's typical voltage and current draw of your connected appliances to set appropriate protection thresholds.
- For critical loads, consider setting the trip and recovery times to values that balance protection with operational continuity.
- Regularly check the kWh display (on LC-AVP-3) to monitor energy consumption for connected circuits.
10. Warranty and Support
For warranty information, technical support, or service, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.
A detailed user manual in PDF format may be available for download. Please refer to the official product page or contact customer support for access to the PDF manual.