1. Introduction
This manual provides essential information for the installation, operation, and maintenance of your EASUN POWER ISolar-SMH-III-4.2KW Solar Hybrid Inverter. This advanced inverter integrates a pure sine wave inverter, an MPPT solar charge controller, and a battery charger into one unit, offering uninterruptible power support in a compact size. It is designed to provide high-quality AC power with high efficiency and stable output, suitable for various household appliances.
Key features include:
- Pure sine wave solar inverter (on/off Grid)
- Output power factor 1.0
- Can run without battery
- Built-in Lithium battery automatic activation
- Dual communication ports for Battery communication and Wifi communication
- Built-in 120A MPPT Solar charge: max 6200W (for 4.2KW)
- High PV input voltage range (60~500VDC)
- Built-in anti-dust kit for harsh environments
- Smart battery charge design to optimize battery life
- WiFi & GPRS available for iOS and Android
- Dual output
2. Safety Information
Please read all instructions and cautionary markings on the unit and in this manual before installation and operation. Failure to follow these instructions may result in electric shock, fire, or severe injury.
- Only qualified personnel should install or maintain this device.
- Before installation, ensure all power sources are disconnected.
- Do not disassemble the unit. There are no user-serviceable parts inside.
- Keep the inverter away from flammable materials and liquids.
- Ensure proper ventilation to prevent overheating.
- Do not operate the inverter if it is damaged or appears to be malfunctioning.
- Wear appropriate personal protective equipment (PPE) during installation.
3. Product Overview
3.1. LCD Display, LED Indicators, and Function Keys
The inverter features an intuitive LCD display, LED indicators, and function keys for monitoring and configuration.
LED Indicators:
| LED Indicator | State | Messages |
|---|---|---|
| AC / INV | Green Solid On | Output is powered by utility in Line mode. |
| Green Flashing | Output is powered by battery or PV in battery mode. | |
| CHG | Green Solid On | Battery is charging. |
| FAULT | Red Solid On | Fault occurs in the inverter. |
| Red Flashing | Warning condition occurs in the inverter. |
Function Keys:
| Function Key | Description |
|---|---|
| ESC | To exit setting mode |
| UP | To go to previous selection |
| DOWN | To go to next selection |
| ENTER | To confirm the selection in setting mode or enter setting mode |
3.2. Physical Connections
The rear panel of the inverter provides all necessary connection ports for PV input, AC input/output, battery, and communication.
- Power on/off switch
- AC input
- Main output
- Second output
- PV input
- Battery communication/RS-485 port
- WIFI communication/RS-232 port
- Battery input
4. Installation and Setup
4.1. Mounting the Unit
Consider the following points before selecting where to install the inverter:
- Do not mount the inverter on flammable construction materials.
- Mount on a solid surface.
- Install this inverter at eye level in order to allow the LCD display to be read at all times.
- For proper air circulation to dissipate heat, allow a clearance of approx. 20 cm to the side and approx. 50 cm above and below the unit.
- The ambient temperature should be between 0°C and 55°C to ensure optimal operation.
- The recommended installation position is to be adhered to the wall vertically.
- Be sure to keep other objects and surfaces as shown in the diagram to guarantee sufficient heat dissipation and to have enough space for removing wires.
WARNING: SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.
4.2. PV Connection
When selecting proper PV modules, please be sure to consider the following parameters:
- Open circuit Voltage (Voc) of PV modules should not exceed max. PV array open circuit voltage of inverter.
- Open circuit Voltage (Voc) of PV modules should be higher than min. battery voltage.
PV Module Parameters for ISolar SMH III 4.2KW WiFi:
| Parameter | Value | Notes |
|---|---|---|
| Maximum PV output power | 6200W | |
| Maximum PV open circuit voltage | 500VDC | |
| Maximum charge current | 120A | |
| Maximum Power (Pmax) | 250W | Max.PV module numbers in series: 12 x 36V ≈60~450VDC |
| Max.Power Voltage Vmpp(V) | 36V | PV module numbers in parallel: 12 x 8.3 < 120A |
| Max.Power Current Impp(A) | 8.3A | Total PV module numbers: 12 x 2 = 24 |
| Open Circuit Voltage Voc(V) | 40V | |
| Short Circuit Current Isc(A) | 8.9A |
4.3. Battery Connection
The 4.2KW model supports a 24VDC battery system. Ensure correct polarity when connecting batteries.
4.4. System Diagrams
The inverter can operate in various configurations, with or without battery storage, and with or without AC utility power.
5. Operating Instructions
Once installed and connected, the inverter will automatically detect available power sources and operate according to its configured priority. The LCD display provides real-time status and operational data.
5.1. Pure Sine Wave Output
The inverter produces a pure sine wave output, ensuring compatibility and stable operation for sensitive electronics and various household appliances.
The pure sine wave output can drive any kind of load without interference, including:
- TV
- Refrigerator
- Computer
- Wall breaking machine (blender)
- Microwave oven
- Dishwasher
6. Monitoring and Control
The inverter can be monitored and controlled remotely via the SmartESS App, available for iOS and Android devices. This requires connecting an optional GPRS/WIFI module to the communication port.
Communication interfaces include RS232 (Standard) and optional GPRS/WIFI modules.
7. Maintenance
To ensure the longevity and optimal performance of your inverter, regular maintenance is recommended:
- Keep the inverter clean and free from dust. The built-in anti-dust kit helps, but periodic external cleaning is beneficial.
- Ensure proper ventilation around the unit. Check that air vents are not blocked.
- Periodically inspect all wiring connections for tightness and signs of corrosion.
- Monitor the LCD display for any warning or fault messages and address them promptly.
- If the unit requires internal servicing, contact qualified service personnel. Do not attempt to open the inverter yourself.
8. Troubleshooting
If you encounter issues with your inverter, refer to the LED indicator messages (Figure 3) for initial diagnosis. Common issues often relate to power input, battery status, or load conditions.
- No Power Output: Check AC input, PV input, and battery connections. Ensure the power switch is ON. Verify battery voltage is within the operating range.
- Fault Indicator On: Refer to the manual's fault code section (if available in full manual) or contact support with the specific fault message displayed on the LCD.
- Overload Warning: Reduce the connected load. The inverter may temporarily shut down to protect itself.
- Battery Not Charging: Check PV input voltage and current. Ensure AC input is present if charging from utility. Verify battery connections and health.
For complex issues, it is recommended to consult the full product manual or contact technical support.
9. Specifications
Detailed technical specifications for the ISolar SMH III 4.2KW and 6.2KW models:
| Parameter | ISolar SMH III 4.2KW | ISolar SMH III 6.2KW |
|---|---|---|
| General | ||
| Rated Power | 4200VA/4200W | 6200VA/6000W |
| Input | ||
| Voltage | 230VAC | |
| Selectable Voltage Range | 170-280VAC (for personal computers) / 90-280VAC (for home appliances) | |
| Frequency Range | 50Hz/60Hz (Auto sensing) | |
| Output | ||
| AC Voltage Regulation (Batt.Mode) | 230VAC±5% | |
| Surge power | 4400VA | 6400VA |
| Transfer Time | 10ms (for personal computers) / 20ms (for home appliances) | |
| Wave Form | Pure Sine Wave | |
| Battery & AC Charger | ||
| Battery Voltage | 24VDC | 24VDC |
| Maximum Charge Current | 100A | |
| Solar Charger | ||
| MAX.PV Array Power | 6200W | 6500W |
| MPPT Range@ Operating Voltage | 90-450VDC | |
| Maximum PV Array Open Circuit Voltage | 450VDC | |
| Maximum Charging Current | 120A | |
| Maximum Efficiency | 98% | |
| Physical | ||
| Dimension.D*W*H(mm) | 420*350*110mm | |
| Net Weight (kgs) | 9kg | 10kg |
| Communication Interface | RS232 (Standard) / GPRS/WIFI (Optional) | |
| Operating Environment | ||
| Humidity | 5% to 95% Relative Humidity (Non-condensing) | |
| Operating Temperature | -10°C to 55°C | |
| Storage Temperature | -15°C to 60°C | |
10. Warranty and Support
The EASUN POWER ISolar-SMH-III-4.2KW inverter comes with a 1-year warranty from the date of purchase. Please retain your proof of purchase for warranty claims.
For technical support, troubleshooting assistance, or warranty inquiries, please contact your vendor or the manufacturer directly. Ensure you have your model number and purchase details ready.
11. User Tips
No specific user tips were available from customer reviews or Q&A for this product at the time of manual creation. Always ensure all connections are secure and follow the recommended clearances for optimal performance and safety.