The FUZRR FR15B+ and FR17B+ are new technology digital multimeters featuring a two-color protective cover design, hand-held non-slip ergonomic grip, and a large-screen LCD display. These multimeters are characterized by multi-functionality, high precision, high performance, anti-drop durability, safety, and stability.

They can accurately measure AC/DC voltage, high voltage alarm, AC/DC current, frequency, continuity, diode, resistance, capacitance, battery load, NCV (Non-Contact Voltage) and Live wire detection. Both models include misoperation circuit protection, making them suitable for professional electricians, electronic technology maintenance and repair, and essential tools for DIY electronics enthusiasts, homes, and factories.

FUZRR FR17B+ Auto-Ranging Digital Multimeter
FUZRR FR17B+ Auto-Ranging Digital Multimeter with NCV/LIVE and Continuity Buzzer features.
FUZRR FR15B+/FR17B+ Multimeter with 6000 counts True RMS
FUZRR FR15B+/FR17B+ Auto-Ranging Digital Multimeter featuring 6000 counts True RMS.

2. Safety Information

Please read and understand all safety information before using the instrument. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  1. This product strictly adheres to the safety standard of European Electrotechnical Commission EN61010-1 and the technical design standard of China GB T 13978.
  2. Always read the "safety information" thoroughly before using the instrument and operate in strict accordance with the provided instructions.
  3. Measure only within the specified range for each function. Do not rotate the dial switch during measurement to prevent damage from misoperation.
  4. To avoid potential electrical shock, do not touch live conductors exceeding 30V AC and 60V DC during measurements.
  5. When measuring AC and DC voltages over 599V, a high voltage lightning symbol will display, and the buzzer will beep. Exercise extreme caution during such measurements.
  6. Do not use the multimeter in inflammable or explosive environments to prevent danger.
  7. To avoid measurement errors, replace the battery immediately when the low battery symbol ([battery icon]) appears on the meter display.
  8. Before measuring, inspect the test leads and wires for any damage or leakage. Do not use if any damage is found.
  9. Comply with all national regulations and measurement safety standards. When measuring hazardous voltage, wear insulating gloves or flame retardant protective products.

3. General Technical Indicators

  • Safety Level: CAT II 1000V, CAT III 600V
  • Product Range: AUTO
  • Maximum Display: 6000 counts (for both FR15B+ and FR17B+)
  • Sampling Rate: 3 times/second
  • Overload Display: OL
  • Auto Power Off: Approximately 15 minutes
  • Operating Temperature: 0°C to 40°C
  • Precision: 23°C ± 5°C (18°C to 28°C; Humidity <75%); 1 year
  • Storage Temperature: -10°C to 60°C
  • Storage Humidity: ≤80%
  • Altitude: 0 to 2000m
  • Pollution Grade: 2
  • Safety Codes: CE EN61010-1-2-030
  • Electromagnetic Environment: EN61326-1-2
  • Power: AA 1.5V x 3 batteries
  • Dimensions: 183 x 91 x 45mm
  • Weight: 402g (inclusive of battery)

4. Description of Appearance

The following diagram illustrates the main components and their functions on the multimeter.

Multimeter Instrument Structure and Overall Dimensions
Instrument Structure and Overall Dimensions of the FUZRR Digital Multimeter.
Instrument Components
No.ComponentDescription
1Display LCDShows measurement readings and symbols.
2Function keyButtons for various functions like HOLD, RANGE, MAX/MIN, MODE.
3Dial switchSelects the measurement function (e.g., Voltage, Current, Resistance).
4VΩmA InputRed test lead input for Voltage, Resistance, Capacitance, Frequency, Diode, Continuity, and small current measurements.
5COM InputCommon ground black test lead input.
610A InputRed test lead input for high current (up to 10A) measurements.

5. LCD Display and Symbols

The LCD displays various symbols to indicate the current measurement mode, status, and warnings.

LCD Symbols Explanation
No.SymbolExplanationRemark
1OFFTurn off the power
2[Power icon]Auto power-off
3[Battery icon]Low battery indication
4mVDC millivolt
5VDC voltage
6TRUE RMSTrue RMS
7~VAC voltage
8HzFrequency
9= uA,mA,ADC uA,mA,A
10~ uA,mA,AAC uA,mA,A
11Ω KΩ MΩResistance Ω KΩ MΩ
12))) [Diode icon]Continuity beeper, Diode
13[Capacitance icon] nF uF mFCapacitance nF uF mF
14RELClear the relative value
15[Battery icon]Battery 1.5V, 9V
16NCV EFNon-contact sensing signal
17LIVEAC Live
18°C/°FTemperature
19[Current Clamp icon]Current Clamp
20VFDAC variable frequency measurement

6. Key Functions

Multimeter Key Functions
No.KeyDescription
1MODE/VFDMode switch (short press); Press and hold for 3 seconds for VFD function.
2MAX/MINMeasures and displays the maximum or minimum value.
3RANGEManual range selection (overrides auto-ranging).
4HOLDData hold (short press) to freeze the current reading on the display.
5[Backlight icon]Activates or deactivates the backlight.

7. International Electrical Symbols

Familiarize yourself with these international safety and compliance symbols:

Electrical Symbols Explanation
No.SymbolExplanation
1!Be careful! Indicates a dangerous operation.
2[High current/voltage warning icon]High current! Indicates a high voltage hazard warning.
3CEEuropean Union unified directive, European CE certification.
4[Grounding icon]Grounding.
5[Double insulation icon]Double insulation or enhanced insulation protection.
6[WEEE recycling icon]Compliance with WEEE recycling instructions.

8. Technical Specifications

Detailed measurement ranges and accuracies for the FR15B+ and FR17B+ models.

Model Selection and Specifications Table
Comparison of FR15B+ and FR17B+ models with their respective specifications and features.

DC Voltage

RangeFR15B+FR17B+ResolutionAccuracy
DCV Range60.00mV60.00mV0.01mV
600.0mV600.0mV0.1mV
6.000V6.000V0.001V±(0.5%+3)
60.00V60.00V0.01V
600.0V600.0V0.1V
1000V1500V1V±(0.8%+5)

Input protection: Impedance 10MΩ; DC1500V; 1000Vrms

AC Voltage

RangeFR15B+FR17B+ResolutionAccuracy
ACV Range6.000V6.000V0.001V±(0.8%+5) 400Hz;
60.00V60.00V0.01V±(1.2%+5) 1KHz
600.0V600.0V0.1V
1000V1000V1V
VFD (AC Voltage)100~600V / 400Hz100~600V / 400Hz0.1V±(4%+5)
True/RMSTrue/RMS

Input protection: Impedance 10MΩ; 1000Vrms

ACV KHz (Frequency)

RangeFR15B+FR17B+ResolutionAccuracy
Hz Range10.00Hz10.00Hz0.01Hz
100.0Hz100.0Hz0.1Hz±(0.5%+5)
1.000KHz1.000KHz0.001KHz
60KHz60KHz0.01KHz

Input protection: 1000Vrms

Resistance

RangeFR15B+FR17B+ResolutionAccuracy
Ω Range600.0Ω600.0Ω0.1Ω
6.000KΩ6.000KΩ0.001KΩ±(1%+5)
60.00KΩ60.00KΩ0.01KΩ
600.0KΩ600.0KΩ0.1KΩ
6.000MΩ6.000MΩ0.001MΩ±(2.5%+5)
60.00MΩ60.00MΩ0.01MΩ

Input protection: 1000Vrms

Continuity/Diode/NCV/LIVE

FunctionFR15B+FR17B+ResolutionAccuracy
Continuity0.1Ω~30Ω0.1Ω~30Ω0.1Ω-
Diode0.500V~0.800V0.500V~0.800V0.001V-
NCV50V~1000V50V~1000V0~5Cm Non-contact induction
LIVE50V~1000V50V~1000VMeasure the live line

Input protection: 1000Vrms

DC Current

RangeFR15B+FR17B+ResolutionAccuracy
DCA Range600.0uA600.0uA0.1uA
6.000mA6.000mA0.001mA±(0.8%+5)
60.00mA60.00mA0.01mA
600.0mA600.0mA0.1mA
6.000A6.000A0.001A±(2%+5)
10.00A10.00A0.01A

Input protection: FUSE: 500mA/1000V; 10A/1000V; Φ6.3 x 31.5mm; 10A Test time Max 10S

AC Current

RangeFR15B+FR17B+ResolutionAccuracy
ACA Range600.0uA600.0uA0.1uA±(1%+5)
6.000mA6.000mA0.001mA400Hz; ±(1.5%+5)
60.00mA60.00mA0.01mA1KHz
600.0mA600.0mA0.1mA
6.000A6.000A0.001A±(2%+5)
10.00A10.00A0.01A

Input protection: FUSE: 500mA/1000V; 10A/1000V; Φ6.3 x 31.5mm; 10A Test time Max 10S

Temperature

RangeFR15B+FR17B+ResolutionAccuracy
°C/°F Range--50°C~0°C1°C4°C
-0°C~100°C1°C±(1.5%+4)
-100°C~1000°C1°C
--58°F~32°F1°F5°F
-32°F~212°F1°F±(2%+5)
-212°F~1832°F1°F

Input protection: 1000Vrms

Capacitance

RangeFR15B+FR17B+ResolutionAccuracy
Capacitance Range6.000nF6.000nF0.001nF
60.00nF60.00nF0.01nF
600.0nF600.0nF0.01nF±(4%+5)
6.000uF6.000uF0.001uF
60.00uF60.00uF0.01uF
600.0uF600.0uF0.1uF
6000uF6000uF0.001mF±(8%+5)
60000uF60000uF0.1mF

Input protection: 1000Vrms

Current Clamp

RangeFR15B+FR17B+ResolutionAccuracy
Current Clamp6.0A (AC/DC)6.0A (AC/DC)0.1A
60.0A (AC/DC)60.0A (AC/DC)0.1A±(3%+5)
600.0A (AC/DC)600.0A (AC/DC)0.1A

Input protection: 1000Vrms; Current clamp output: 1A/1mV AC

KHz (Frequency)

RangeFR15B+FR17B+ResolutionAccuracy
Hz Range10.00Hz10.00Hz0.01Hz
100.0Hz100.0Hz0.1Hz±(0.5%+5)
1.000KHz1.000KHz0.001KHz
10.00KHz10.00KHz0.01KHz
100.0KHz100.0KHz0.1KHz
1.000MHz1.000MHz0.001MHz
20.00MHz20.00MHz0.01MHz
Duty cycle10~90%10~90%0.1%±(1%+5)

Input protection: 1000Vrms; 10Hz~100KHz/ ≤200mVrms; 100KHz~10MKHz/ ≤500mVrms

9. Quick Application Guide

This section provides a quick reference for common measurement applications.

Measurement Application Examples
Measurement RangeTest Pen Link HoleIllustration of Measurement Examples
ACV/HzBlack COM Red VΩACV 220V, 380V/50HZ
DCVBlack COM Red VΩElectric Vehicle Lithium 36V, 48V, Vehicle charging systems
Continuity/DiodeBlack COM Red VΩContinuity buzzer beeps, Diode forward
ResistanceBlack COM Red VΩSMD Resistors, Plug-In Resistors, On-Circuit Impedance
CapacitanceBlack COM Red VΩChip Capacitors, Electrolytic Capacitors
NCV/LIVERed VΩMeasurement AC voltage, LIVE firewire alarm
DCA uAmABlack COM Red uAmAVΩMeter pen series circuit measurement, prohibited input AC220V
DCA 10ABlack COM Red AMeter pen series circuit measurement, prohibited input AC220V
ACA uAmABlack COM Red uAmAVΩMeter pen series circuit measurement, prohibited input AC220V
ACA 10ABlack COM Red AMeter pen series circuit measurement, prohibited input AC220V
Current clamp 600A (AC/DC)Black COM Red VΩSelect using Current clamp can measure AC/DC600A
Temperature °C/°FBlack COM Red VΩTesting of air-conditioning systems, refrigeration systems
KHzBlack COM Red VΩFrequency signal measurement

10. Maintenance

10.1. Replace Fuse

WARNING: Disconnect the test leads from the circuit before replacing the fuse to avoid electric shock.

Fuse Specification:

  • FR15B+ / FR17B+:
    • F1: 500mA/1000V Φ6.3x31.5mm
    • F2: 10A/1000V Φ6.3x31.5mm

10.2. Replace Battery

WARNING: Disconnect the test leads from the circuit before replacing the battery to avoid electric shock.

Battery Specification: LR06 AA 1.5V x 3

To replace the battery:

  1. Unscrew the battery cover.
  2. Replace the old batteries with new ones, ensuring correct polarity.
  3. After replacing the battery, ensure the battery cover is tightly screwed back before using the meter normally.
Battery replacement diagram for multimeter
Diagram showing how to open the battery compartment for replacement.

10.3. Repair

WARNING: Repairs should only be performed by an approved and professionally experienced technician.

If a fault cannot be resolved, please contact the official after-sales service. Non-professionals should not attempt repairs to avoid damaging the instrument or risking electric shock due to improper maintenance.

11. Troubleshooting

This section provides general troubleshooting tips. For specific issues not covered here, please refer to the contact information for support.

  • No Display / Faint Display: Check battery level and replace if low. Ensure batteries are inserted with correct polarity.
  • Incorrect Readings: Verify the correct function and range are selected. Ensure test leads are properly connected and not damaged. Check for external interference.
  • No Continuity Beep: Ensure the continuity function is selected and test leads are making good contact.
  • Overload Indication (OL): The measurement exceeds the selected range. Switch to a higher range or a different function if applicable.

12. User Tips

Based on common user experiences, here are some tips for optimal use:

  • Always start with the highest range when measuring an unknown voltage or current to prevent damage to the multimeter.
  • For precise measurements, ensure the test leads are clean and free from corrosion.
  • Utilize the HOLD function to freeze readings in hard-to-reach or poorly lit areas.
  • The auto-ranging feature simplifies operation, but manual range can be useful for specific diagnostic tasks.

13. Package Contents

Upon opening the package, please verify that all the following items are included:

  • 1 × FUZRR Digital Multimeter (FR15B+ or FR17B+ model)
  • 2 × Test Leads (Red and Black)
  • 1 × User Manual (this document)
  • (Note: Batteries are not included and must be purchased separately.)
Product accessories for FUZRR FR15B+ and FR17B+ multimeters
Included accessories for both FR15B+ and FR17B+ models, showing multimeter, test leads, and manual.

14. Support and Contact Information

For technical support, service, or inquiries, please contact:

GuangZhou ZhengNeng Electronics Technology Co.LTD
Address: 4F, Bldg. 6, Hongjie Ind. Park, Baiyun Dist., Guangzhou, Guangdong, China
Tel: 020-37319325, 020-36544171, 020-36544172
Fax: 020-37319075
Post: 510540
Website: www.znele.com

Manual Revision: REV01-202511

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.