1. Product Introduction

1.1 Product Overview

The HLTNC EC1 Series bus-type open-loop stepper driver utilizes the EtherCAT bus communication interface, integrating EtherCAT slave station technology, vector control technology, built-in micro-step technology, and adaptive filtering technology. This design enables real-time control and data transmission for stepper systems, optimizing motor performance. Key benefits include excellent smoothness, ultra-low noise at medium and low speeds, enhanced high-speed torque, and reduced motor heating through smooth and precise pure sine current vector control.

The EC1 Series drivers are compatible with multiple master station control systems such as Beckhoff, Omron, Keyence, HuaChuan, and XinJie, making them suitable for various industrial applications including textiles, robotics, lithium battery equipment, 3C electronics, new energy, photovoltaic equipment, medical equipment, and testing equipment.

1.2 Product Features

  • New generation 32-bit RISC-V MCU for high cost performance, stability, and superior noise/vibration.
  • Supports EtherCAT slave technology, CIA301 and CIA402 sub-protocols, CSP, PV, PP, and HM modes.
  • User-configurable current, subdivision, and lock-in current via EtherCAT bus or serial communication.
  • Built-in single-axis controller for synchronous position, speed, position, and return-to-origin modes.
  • 3 channels of optically isolated programmable input interfaces for driver limit, origin, emergency stop, and probe functions.
  • Built-in micro-subdivision and motor parameter setting.
  • Adjustable current reduction ratio when stationary.
  • Overvoltage and undervoltage protection.
  • Excellent stability, low noise, and vibration performance.
  • Supports position control, speed control, etc. modes.
HLTNC ECA1-86E and EC1-872 EtherCAT Stepper Drivers
Figure 1.1: HLTNC ECA1-86E and EC1-872 EtherCAT Stepper Drivers. The ECA1-86E (left) is a closed-loop driver, and the EC1-872 (right) is an open-loop driver.
Product Differentiation: ECA1-86E with encoder, EC1-872 without encoder
Figure 1.2: Product Differentiation. The ECA1-86E model includes an encoder for closed-loop operation, while the EC1-872 model operates without an encoder in open-loop mode.

2. Specifications

2.1 General Specifications

Parameter ECA1-86E (Closed Loop) EC1-872 (Open Loop)
Peak current 0.1~7.0A 0.1~7.2A
Input voltage AC 20-60V / DC 24-80V DC 24-80V
Adaptive Motor 60/86 Hybrid Stepping Motor 60/86 Hybrid Stepping Motor
Digital input Home, Positive limit, Negative limit, Fast stop, Probe
Digital output Alarm output, Position output, Motor enable output, Free output
Output Power 18.65-37.5W
Certification CE
Wireless Functionality No
Battery Included No

2.2 Environmental Conditions

Parameter Value
Cooling Type Natural cooling, fan cooling
Operating Temperature 0~50°C (driver), up to 80°C (motor)
Humidity 40~90%RH
Vibration 10-55Hz/0.15mm
Storage Temperature -20°C~65°C
Operating Environment Avoid proximity to heating equipment, dust, oil mist, corrosive gases, high humidity, strong vibration, flammable gases, and conductive dust.
Product dimensions and parameters for ECA1-86E and EC1-872
Figure 2.1: Detailed product dimensions and parameters for both ECA1-86E and EC1-872 models.

3. Setup and Installation

3.1 Mechanical Installation

The reliable operating temperature for the driver is typically within 50°C, and for the motor, it is within 80°C. To ensure optimal performance and longevity:

  • **Current Mode**: It is recommended to use the automatic half-current mode. This reduces motor and driver heat when the motor is stopped.
  • **Mounting**: Install the driver on its side to promote strong air convection from the bottom surface.
  • **Cooling**: If necessary, install a fan near the driver to aid heat dissipation and maintain the operating temperature within a reliable range.
EC1-872 driver from different angles (front, side, top, bottom)
Figure 3.1: EC1-872 Driver Views. Shows the front, side, top, and bottom views of the EC1-872 driver, useful for mechanical installation planning.

3.2 Driver Interface Overview

The EC1 Series drivers feature various interfaces for communication, power, motor control, and input/output signals. Refer to the table below for a summary of the main interfaces.

Name Function Description
ECAT IN/OUT ETHERCAT Communication Port ECAT IN (input from previous driver), ECAT OUT (output to next driver)
IN/OUT (X0, X1, X2, XCOM, Y0, YCOM) Input/Output Ports Low-speed digital signal input/output interface. XCOM is common terminal for inputs (+24V). YCOM is common terminal for outputs (compatible with common-negative and common-positive connections).
MOTOR (A+, A-, B+, B-) Motor Port Wiring port for two-phase stepping motor.
POWER (VDC, GND) Power Port DC 20-50V (for ECA1-86E) or DC 24-80V (for EC1-872) input.

3.3 Wiring Diagrams

Proper wiring is crucial for the safe and correct operation of the EtherCAT stepper driver. The system supports a bus-type stepping network scheme, allowing multiple drives to operate in parallel.

Physical Wiring Diagram for ECA1-86E EtherCAT Stepper Driver
Figure 3.2: Physical Wiring Diagram for ECA1-86E. This diagram illustrates connecting the ECA1-86E driver to an EtherCAT main station, power supply (VDC: 24V-80V / 20V-60V), and a stepping motor. It shows a bus-type stepping network scheme supporting multiple drive parallel operation with coded line chaining.
Physical Wiring Diagram for EC1-872 EtherCAT Stepper Driver
Figure 3.3: Physical Wiring Diagram for EC1-872. This diagram illustrates connecting the EC1-872 driver to an EtherCAT main station, power supply (VDC: 24V-80V), and a stepping motor. It shows a bus-type stepping network scheme supporting multiple drive parallel operation.
ECA1-86E EtherCAT Substation Wiring Diagram
Figure 3.4: ECA1-86E Wiring Diagram. Shows how multiple ECA1-86E drivers (ECAT Substation) are connected in a chain to an ECAT main station via network ports.
EC1-872 EtherCAT Substation Wiring Diagram
Figure 3.5: EC1-872 Wiring Diagram. Shows how multiple EC1-872 drivers (ECAT Substation) are connected in a chain to an ECAT main station via network ports, similar to the ECA1-86E setup.

3.3.1 Input Signal Interface

The input interface is programmable and protected by photoelectric isolation. It uses a common anode connection method and supports NPN wiring, requiring an external +24V power supply. For reliable operation, the driving current from the controller should be at least 10mA, and the input pulse width must be greater than 10ms. The default effective level is rising edge or high level, but can be configured via the master station.

3.3.2 Output Signal Interface

The output interface is optically isolated and compatible with both common cathode and common anode connection methods, supporting NPN and PNP wiring. It can support active master controllers with high and low levels. The initial default state of the output interface is normally open, but can be configured to normally closed via the master station.

Application Scenarios for EtherCAT Stepper Drivers
Figure 3.6: Application Scenarios. Illustrates typical uses for the EtherCAT stepper drivers, including 3D printers, CNC machines, textile machines, and cutting machines.

4. Operating Instructions

4.1 Indicator Lights

The driver features recessed surface-mounted LEDs to indicate operational status. These can be observed through small circular holes on the driver. The definitions are as follows:

Name Color Description
ALM (Alarm) Red Normally off when power is on. Flashes with green light to indicate an alarm or abnormality.
PWR (Power/Status) Green Flashes slowly (1000ms) when not enabled. Remains on constantly when enabled. Flashes rapidly (250ms) during movement. Flashes with red light to indicate an alarm.

4.2 Parameter Description and Settings

The EC1 Series drivers offer extensive parameters for configuration, accessible via the EtherCAT bus or serial communication. These parameters control communication, I/O functions, motor behavior, and operational modes. For a complete list and detailed descriptions of all parameters, including their index, sub-index, name, attribute, type, range, and default values, please refer to the official PDF user manual, specifically sections 4.1 and 4.2.

Key parameter categories include:

  • **Communication Parameters**: Device type, error register, save/restore parameters.
  • **I/O Function Configuration**: Input/output signal interface settings, polarity, and function selection.
  • **Motor Control Parameters**: Open-loop peak current, locking time, current reduction percentage, motor model selection, proportional gain adjustments, and frequency resonance suppression.
  • **CIA402 Parameters**: Control word, status word, target position, internal speed/location commands, and various motion control settings.

Note: When saving parameters, ensure the "red indicator light" goes out before cutting off power to confirm successful saving.

4.3 Control Word and Status Word Bit Definitions

The control word (0x6040) and status word (0x6041) are crucial for command issuance and status monitoring between the master and slave stations. These are defined by specific bits:

0x6040 Control Word

Bit Function
0Switch on
1Enable voltage
2Quick stop (logic 0 is valid)
3Enable operation
4-6Operation mode specific
7Fault reset (rising edge is valid)
8Halt
9-15Reserved

0x6041 Status Word

Bit Function
0Ready to switch on
1Switched on
2Operation enabled
3Fault
4Voltage enabled
5Quick stop
6Switch on disabled
9Remote
11Internal limit
7, 8, 10...The pattern is relevant

4.4 Control Modes and State Transitions

The drivers support various control modes, including Synchronous Positioning Mode (CSP), Position Mode (PP), Speed Mode (PV), and Return to Origin Mode (HM). Each mode involves specific state transitions and object dictionary interactions (6040H control word and 6041H status word) for command issuance and status monitoring. Detailed state transition diagrams and object dictionaries are available in sections 5.3 and 5.4 of the official PDF user manual.

4.5 Return to Origin Mode (HM)

The EC1 Series drivers support various return-to-origin modes (17-30, 35, 37), which typically require positive and negative limits and an origin signal. These modes define how the motor finds its home position, including stopping at limits, origin signals, or using the current position as zero. Detailed explanations and diagrams for each method (e.g., Methods 17 and 18 for negative/positive limit return to zero, Methods 19 and 20 for origin signal rising edge, etc.) are provided in section 5.5 of the official PDF user manual.

For example, in Method 17 ("negative limit return to zero"), the driver moves until it encounters the rising edge of a limit signal, decelerates, stops, then reverses to find the falling edge of the limit signal, decelerates, and stops again.

Video 4.1: EtherCAT Stepper Driver Demonstration. This video shows the physical connection of multiple EtherCAT stepper drivers to a controller and motors, demonstrating their parallel operation and basic functionality.

5. Maintenance

To ensure the long-term reliability and optimal performance of your HLTNC EtherCAT Stepper Driver, adhere to the following maintenance guidelines:

  • **Environmental Control**: Operate the driver within the specified temperature (0-50°C) and humidity (40-90%RH) ranges. Avoid environments with excessive dust, oil mist, corrosive gases, strong vibrations, or flammable/conductive materials.
  • **Cooling**: Ensure adequate ventilation and cooling. If using natural cooling, verify sufficient air convection. For demanding applications, consider installing a fan to assist heat dissipation.
  • **Wiring Integrity**: Regularly inspect all wiring connections for tightness and signs of wear or damage. Loose connections can lead to intermittent operation or component failure.
  • **Firmware Updates**: Keep the driver firmware updated as recommended by HLTNC to benefit from performance improvements and bug fixes.
  • **Cleaning**: Keep the driver and its surroundings clean. Dust and debris can impede cooling and potentially cause electrical issues. Use a soft, dry cloth for cleaning.

6. Troubleshooting

This section provides guidance on common issues and their resolutions. Refer to the indicator lights for initial diagnosis.

6.1 Driver Failure Codes

The driver's indicator lights (Red and Green) flash in specific patterns to indicate fault codes. The table below lists common fault codes, their implications, and whether they can be cleared.

Fault Code (0x603F/0x2707) Implication Clearable? Red Light Flashing Green Light Flashing
0x2211Over currentNo11
0x4211Over voltageNo12
0x5110Phase A of the motor is missingNo13
0x5120Phase B of the motor is missingNo14
0x7329Position limit errorYes15
0x8401Position deviationNo16
0x8402Command over speedYes17
0x8403PWM cycle pulse increment too largeYes18
0x5530-0x5534EEPROM Parameter/Communication/Manufacturer/Motion Save FailureYes31-5 (respectively)

To clear current alarms, write '1' to 0x2708. To clear the fault record (0x2707), write '1' to 0x2709.

Reason (Alarm Code) Confirmation Method Treatment Measure
Bus Voltage over/under voltage (0x3211) Measure voltage between VDC and GND terminals. Ensure drive operates within specified voltage range. If pump lift voltage is too high, reduce acceleration/deceleration. Check power cord wiring.
Driver is overheating (0x4211) Check if driver is overloaded. Use thermometer for ambient temperature. Confirm load size. Ensure ambient temperature is within range.
Motor phase A or B missing (0x5110, 0x5120) Confirm motor wiring. Ensure motor wiring is correct and normal.
Position limit error (0x7329) View 0x60FD bits 0 and 1 via upper computer/main station. Check 0x6064 against 0x607D:01/02. Ensure IO input polarity matches external switch type. Modify IO drive input polarity or change switch type if inconsistent. Software limit protection operates normally.
Command over speed (0x8402) Determine single-turn pulses of master station and driver subdivision. Check synchronous cycle settings. Modify driver or master station software to match pulse counts. Adjust synchronous cycle to be less than or equal to drive cycle.
PWM cycle pulse increment too large (0x8403) Driver acceleration is too large. Reduce driver acceleration.
EEPROM Save parameter failure (0x5530-0x5534) Software anomaly or damaged driver. Restore factory parameters (0x1011). If persistent, replace driver.
ECAT communication/alarm (0x82xx) Check ESC main station operation, control shaft number, cable connection, XML file version, PDO channel set, and environment interference. Switch to ESC main station, verify control shaft number, use screened cable, ensure XML file version and PDO channel set are correct, and optimize environment.

7. User Tips

  • **Initial Setup**: Always double-check all wiring connections before powering on the device to prevent damage.
  • **Parameter Saving**: After making any parameter changes, ensure they are properly saved. Wait for the red indicator light to go out before disconnecting power to confirm the save operation.
  • **Environmental Monitoring**: Pay close attention to the operating environment. High temperatures, humidity, or the presence of contaminants can significantly impact driver performance and lifespan.
  • **Troubleshooting**: When encountering issues, first consult the indicator lights for fault codes. These provide valuable initial diagnostic information.
  • **PDF Manual**: For in-depth technical details, parameter configurations, and advanced operating modes, always refer to the comprehensive PDF user manual. View User Manual (PDF)

8. Warranty and Support

8.1 Warranty Information

HLTNC provides a one-year free repair service for products purchased from us, covering damages due to the product's own fault during normal use. This warranty does not cover damages resulting from:

  • Customer's own wiring errors.
  • Exceeding the rated working voltage.
  • Connecting DC power supply to AC power supply.
  • Operation in extremely harsh environments (damp, cold, hot) without prior notification to the company.
  • Disassembly of the driver's casing or torn sequence labels.
  • Damage occurring more than 15 days after customer receipt, or due to unforeseen natural disasters.

For issues not covered by warranty, repair costs will be charged. For product malfunctions within three months of purchase, a free replacement service is offered after technical staff confirm the product's fault. The customer is responsible for sending the faulty product to HLTNC, and HLTNC will send a new product back.

When returning products for replacement, ensure complete packaging and intact accessories to prevent further damage.

8.2 After-Sales Service

If you encounter any technical problems while using this product, please contact HLTNC for support.

National Toll-Free Service Hotline: 0755-23206995

© 2023 HLTNC. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.