MYOslim EMS Body Sculpting Electromagnetic Stimulator 6500W

Contents

MYOslim EMS Body Sculpting Electromagnetic Stimulator User Manual

Brand: MYOslim | Model: EMS Body Sculpting Electromagnetic Stimulator 6500W

1. Introduction and Overview

The MYOslim EMS Body Sculpting Electromagnetic Stimulator utilizes advanced High-Intensity Focused Electromagnetic (HI-EMT) technology. This innovative device is designed to induce powerful muscle contractions, promoting muscle growth and reshaping the internal structure of muscles. It also facilitates significant fat breakdown through intense muscle contractions, leading to the release and metabolism of fatty acids over several weeks.

Key Features:

  • Advanced HI-EMT Technology: Employs high-energy focused electromagnetic waves for intense muscle contractions, muscle growth, and deep internal structural reshaping.
  • HD Touch Screen: Simplifies operation with clear visibility, adjustable brightness, and a user-friendly interface available in 8 languages.
  • Real-time Monitoring and Guidance: Displays remaining treatment time, utilized channels, treatment methods, applied treatment types, and attachments, aiding in real-time progress monitoring.
  • Upgradeability: Offers flexible upgrade options to meet evolving therapeutic needs.
  • Pure Copper Coil: Adopts solid copper tubes with high density and powerful energy output for maximum treatment results.
  • High-speed Heat Dissipation: Features an efficient fan system for reliable performance and anti-scalding protection.
  • Stable Bracket: Equipped with a metal handle bracket for stability and drop resistance.
MYOslim EMS Body Sculpting Machine with 4 handles, highlighting 15 Tesla high intensity and 200Hz high frequency, capable of building muscle, burning fat, increasing strength, and being non-invasive. Shows application on abdomen, buttocks, and thighs.
Figure 1: MYOslim EMS Body Sculpting Machine with key features and application areas.
Diagram showing the internal components and advantages of the MYOslim machine, including a pure copper coil, PC+ABS casing, centrifugal fan for heat dissipation, and a stable bracket.
Figure 2: Internal components and advantages of the MYOslim machine.

2. General Information

2.1 Indications for Use

The EMS Body Sculpt is intended for:

  • Improvement of abdominal tone, strengthening of the abdominal muscles, and development of a fitter abdomen.
  • Strengthening, toning, and firming of buttocks, thighs, and calves.
  • Improvement of muscle tone and firmness for strengthening muscles in arms.

2.2 Operating Environment

The operating environment is crucial for the effectiveness and safety of the device.

  • Clean and Hygienic Environment: The area should be clean and hygienic to prevent contamination. Regular cleaning and disinfection of equipment and accessories are essential.
  • Appropriate Temperature and Humidity: Ensure the environment's temperature and humidity are within the manufacturer's specified range. Extreme conditions can affect performance.
  • Adequate Lighting: Sufficient lighting is needed for clear operation and precise procedures.
  • Good Ventilation: The area should have adequate air circulation to prevent accumulation of harmful gases.
  • Safety Measures: The operating environment should include safety measures like fire extinguishers and first aid equipment. Operators must be familiar with safety procedures.
  • Avoidance of Interference Sources: Keep the equipment away from electromagnetic fields or other devices that could cause interference.
  • Operator Training: All operators must undergo proper training for correct usage and safety procedures.

2.3 Patient Profile

This machine is suitable for adults seeking healthy weight loss who have no physical diseases and no metal substances in their bodies.

2.4 Description of the Device

The EMS Body Sculpt offers a simple and effective treatment process. You can easily adjust the digital energy selection treatment plan or diagnostic procedure. Treatment parameters can be manually adjusted via the touch screen. You can also create precise treatment plans by configuring the age group and gender of the person being treated.

3. Safety Precautions and Warnings

3.1 Contraindications

Do NOT use the device if any of the following apply:

  • Wounds on the skin (avoiding wounds when using).
  • Patients with heart disease (e.g., arrhythmias), especially those with pacemakers.
  • Cancer patients.
  • Patients with infectious diseases.
  • Pregnant women, lactating women, or during menstrual period.
  • Major surgery patients, diabetic patients.
  • Presence of any metal in the body.
  • People with cerebrovascular disease (stroke patients).

3.2 Possible Side Effects

These effects may include but are not limited to:

  • Muscle soreness.
  • Reduction in muscle fat.
  • Temporary muscle spasms.
  • Transient joint or muscle tendon pain.
  • Localized redness or skin flushing.

3.3 Precautions Before Use

  • Do not use when feeling full; wait at least one hour after meals.
  • Before using the instrument, remove any metal jewelry you are wearing.
  • Before starting the operation, touch the probe vertically to the skin, then turn on the switch of the main unit and adjust the intensity of the operation mode.
  • Start at the lowest level and gradually increase the intensity according to the user's skin tolerance.
  • It is forbidden to eat or drink during the operation. Wait at least one hour after the operation before eating.

4. Device Components and Accessories

4.1 Front and Rear Panel Overview

Front view of the MYOslim EMS Body Sculpting machine, showing the display screen and EMS handles.
Figure 3: Front View of the Instrument. Components include Display screen and EMS Handles.
Rear view of the MYOslim EMS Body Sculpting machine, showing the handle connections, power plug, switch, and fuse.
Figure 4: Rear View of the Instrument. Components include Handle connections, Switch, Fuse, and Power plug.

Note: The handle can only be used by the original machine and cannot be used interchangeably.

4.2 Handle Types

Image showing different types of handles for the MYOslim EMS Body Sculpting machine, including standard handles and an optional cushion handle.
Figure 5: Standard handles and optional cushion handle.

4.3 List of Accessories

SerialNameQuantityPicture
1Host1 setHost machine
2Handle2Standard handles
Cushion (optional accessories)1Cushion handle
3Belt7*100CM*2, 5*60CM*2Belts for securing handles
4Power cable1Power cable
5Electronic manual1 copy

5. Device Installation

  1. Install the Handle Bracket: Use a screwdriver to install the handle brackets on both sides of the machine.
  2. Apply Handle Film: Stick the black film to the working part of the handle.
  3. Install the Handle: Align the hole and fasten the clip. Lock the key ring to secure.
  4. Connect Power: Connect one end of the power cord to the machine and the other end to a power socket. Do not connect multiple machines to the same socket.
  5. Press the Back Switch: Turn on the power switch located on the back of the machine (light will turn on).
Diagram showing the steps for installing the handle bracket, applying handle film, installing the handle, connecting power, and pressing the back switch.
Figure 6: Device Installation Steps.

6. Basic Device Operation

6.1 Handle Exchange

Important: The handle must be calibrated every time it is installed or replaced. When replacing the handle, you must turn off the power of the machine. The handle cannot be replaced when the machine is powered on.

6.2 Device Start Up/Shut Down

  1. Connect one end of the power cord to the machine and plug the other end into the main socket. Do not connect multiple machines to the socket.
  2. Move the manual switch on the rear panel to the "o" position.
  3. Press the button on the front panel to start.
  4. When the treatment is finished, press and hold the power button to turn off the machine.

6.3 Navigation Controls and Unit Settings

Pre-treatment regimens can be modified via on-screen controls. The treatment interface displays various items and functions for setting up therapy parameters.

Screenshot of the MYOslim machine's touch screen interface showing language selection with 8 options including English, Chinese, Japanese, Korean, Portuguese, Spanish, French, and Russian.
Figure 7: Language settings on the HD Touch Screen.

The device offers 8 language options, covering a wide range of users.

Video 1: Overview of MYOslim machine operation, including startup, interface navigation, and a demonstration of magnetic field strength with dancing coins. It also shows the application of handles on the body.

Setting the Therapy by Controls:

The treatment interface allows modification of pre-treatment regimens. Key elements include:

  • Navigation controls (List, Pattern, Records).
  • Channels selector (A, B).
  • Stop therapy button.
  • Start/pause therapy button.
  • Setting up therapy parameters (RF, Time, Energy, Frequency).

Note: Adjust the corresponding intensity/stage frequency/time according to different customer needs. Click the start/pause button to begin. If the customer requests to pause, click start/pause. After work is completed, click the back button to return.

7. Therapy Application

7.1 Preparing the Therapy

  1. Communicate with patients to understand their needs and comfort levels.
  2. Ensure the patient is in good health and has no contraindications.
  3. Ensure the patient is well-hydrated before the session.
  4. Patient should wear appropriate, comfortable clothing.
  5. Avoid eating large quantities before the session.
  6. Familiarize yourself with the treatment process.
  7. Avoid drinking alcohol before the session.

7.2 Placing the Handle

Proper placement of the handles is essential for effective treatment. Use the provided belts to secure the handles to the target areas.

Diagrams showing correct handle placement for various body areas: Belly, Buttock, Arm, Thigh, Calf, and Arse (pelvic floor).
Figure 8: Handle Placement for different body areas.
Before and after images showing body contouring results on the arm, belly, arse, thigh, and buttock, demonstrating multiple uses of the machine.
Figure 9: Before and After results for various body areas.
Image showing a person relaxing while receiving EMS treatment, with text 'No exercise needed slim down while lying down'.
Figure 10: Relaxed treatment experience.

7.3 Muscle Contractions and Body Shape Contouring

A typical course of treatment involves 4 sessions, each lasting 30 minutes, performed at least twice a week for two consecutive weeks.

  • Non-invasive: No surgery or injections.
  • Non-radiating: Safe electromagnetic field.
  • Non-invasive Buttock Procedure: Specific protocols for buttock enhancement.
  • Body Sculpt: Targets specific areas for contouring.
  • No Downtime: Patients can resume normal activities immediately.
  • No Pain: Generally comfortable with strong muscle contractions.
  • Operator Independent: Easy to use with minimal supervision.
  • No Consumables: No need for gels or other disposable items.
Infographic detailing the benefits of MYOslim EMS Body Sculpting, including non-invasive, non-radiating, no downtime, no pain, operator independent, and no consumables.
Figure 11: Benefits of MYOslim EMS Body Sculpting.

7.4 Operating Principle

Muscles respond through deep remodeling of their internal structure, specifically muscle fiber growth (muscle hypertrophy) and the formation of new protein chains and muscle fibers (muscle hyperplasia). This process leads to an increase in muscle density and volume.

Diagram illustrating the operating principle of high-intensity focused electromagnetic field energy technology, showing before and after effects on muscle and fat tissue.
Figure 12: Operating Principle of HI-EMT.

7.5 Treatment Data

Average effects observed in 30 candidates:

  • Fat thickness decrease: 32%
  • Fat thickness decrease: 27.5%
  • Diastasis rectus abdominis (DRA) improvement: 24.6%
  • Increase in muscle bundles: 14.3%
  • Waist circumference lost: 5.8 CM
Infographic showing average treatment data from 30 candidates, including percentage decrease in fat thickness, improvement in diastasis rectus abdominis, increase in muscle bundles, and waist circumference loss.
Figure 13: Average Treatment Data.

8. Maintenance and Repair

8.1 Daily Inspection

Regularly inspect instruments and components. Ensure the power socket has a reliable ground connection. Check the power cord for damage before use and discontinue use if damaged.

8.2 Cleaning

Instrument cleaning should be performed regularly. The device housing can be wiped with a damp cloth, soapy water, or a neutral detergent while the instrument is powered off. The logo is silk-screen printed, and other parts are spray-painted. Use cotton paper towels or ordinary toilet paper moistened with water to wipe clean; do not use alcohol-based detergents.

8.3 Cleaning of Accessories

Accessories that come into contact with the patient's skin should be cleaned and disinfected with 75% alcohol before and after use. Do not soak directly in alcohol-based detergent; wipe with pure cotton material.

8.4 Replacing the Fuse

To prevent electric shock, always turn off the power and unplug the power plug before replacing the fuse. The fuse is located below the handle junction on the back of the machine. An additional spare fuse is included.

8.5 Storage and Transportation

  • Storage: Store the instrument in its original packaging box in a well-ventilated room. The packaging box should be padded. Maintain ambient temperature between -10°C and 40°C, and relative humidity not exceeding 93%. Do not store near flammable, explosive, or corrosive gases.
  • Transportation: The instrument is suitable for road, railway, air, and water transportation. During loading and unloading, prevent severe vibration and shock. Protect from moisture and do not mix with flammable or corrosive substances. Specific requirements are detailed in the order contract.

9. Troubleshooting

Fault PhenomenonCausesExclusions and Workarounds
Device not working
  • The power plug is not inserted into the socket.
  • Power switch not on.
  • Power fuse failure.
  • Check the power.
  • Check the power switch.
  • Replace the fuse.
Handle not workingCheck the handle for loose connection.Reseat the handle.

10. Specifications

NameValue
ModelE-04
Input Power SupplyAC110V-220V 50/60Hz
Output Maximum Power0-6500W
Frequency5-200HZ
Screen Size8.0 inches
Machine ColorBlack

10.1 Electromagnetic Compatibility (EMC)

Radiated Electromagnetic Field Immunity Test:

  • Port: Enclosure
  • Basic Standard: IEC 61000-4-3:2020
  • Test Level: 30V/m with 80% AM, 1kHz Modulation.
  • Standard Requirement: A
  • Tester: Sam Liu
  • Temperature: 25°C
  • Humidity: 54%

10.2 Test Equipment

DescriptionManufacturerModelIdentifierCal. DateCal. Due
Signal GeneratorIFA2023BN/A15/03/202214/03/2023
Power AmplifierAR150W1000N/A15/03/202214/03/2023
Power AntennaAR25S1G4AN/A15/03/202214/03/2023

10.3 Block Diagram of Test Setup

Block diagram of the electromagnetic compatibility test setup, showing a 7x4x3 meter chamber, EUT & Support, Power Amp, Signal Generator, EUT Monitoring using a camera, PC Controller, and Contro Room.
Figure 14: Block Diagram of Test Setup.

11. User Tips

  • Visible Results: Many users report noticing firming results in the stomach area after just a few uses.
  • Treatment Duration: For muscle tightening, expect to see results in 2-4 weeks with 3-5 sessions per week. For fat burning, 1-2 months may show waist circumference reduction, especially when combined with diet. For muscle building, combine with strength training for more significant results.
  • Usage Frequency: Beginners are recommended 15-20 minutes per session, 3 times a week. Advanced users can do 30 minutes per session, 5 times a week. Avoid overuse to prevent muscle fatigue.
  • Safety First: The device is safe for healthy individuals without contraindications like pacemakers or epilepsy. Avoid use on the abdomen during pregnancy or menstruation.
  • Initial Sensation: Some users may experience a slight stinging sensation during the first use. Always start with low intensity and gradually increase it to adapt to your skin tolerance.
  • No Conductive Gel Needed: This device does not require the use of conductive gel.
  • Cleaning: After each use, wipe the electrode with a damp cloth. Avoid using alcohol for cleaning to prevent corrosion.

12. Warranty and Support

12.1 Warranty Card Information

  • Replacement Policy: The machine can be replaced with a new one within 7 days from the date of purchase (with receipt) if it has an intact appearance.
  • Warranty Period: The main machine is guaranteed for one year. Accessories have a warranty period of 3 months.
  • Exclusions: The warranty does not cover man-made damage, faults caused by unauthorized disassembly or modification, accidental falls, lack of reasonable maintenance, or failure to operate according to the instructions in this manual.
  • Maintenance: After the warranty period, paid after-sales service is available. Do not repair the machine without authorization; unauthorized unpacking voids the warranty.

12.2 Maintenance Record Sheet

A maintenance record sheet is provided in the original manual to track product name, purchase date, dealer information, customer details, and any maintenance performed.

12.3 Support

For any questions or support, please contact customer service. Experienced engineers provide online diagnostics and local repair support.

Image highlighting dual repair centers in Mexico and Europe, professional technical team, fast delivery, and local warranty for worry-free service.
Figure 15: Support and Repair Services.

13. Manufacturer Information

Guangzhou Xinwei Electronic Technology Co., Ltd.

The manufacturer, established in 2014, is a professional beauty equipment manufacturer integrating R&D, production, sales, and service. They have over 10 years of experience and a global footprint with warehouses in various countries to ensure fast delivery and local support.

Image detailing the manufacturer's company introduction, highlighting 10 years of experience, strict quality requirements, global sales, and a commitment to customer satisfaction.
Figure 16: Manufacturer Company Introduction.
Image showing various quality assurance certificates for the MYOslim EMS Body Sculpting machine.
Figure 17: Quality Assurance Certificates.

© 2023 MYOslim. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.