DATOUBOSS DT-1218M Hybrid Solar Inverter

User Manual

Model: DT-1218M | Output Power: 1800W | Input Voltage: 12V

1. Introduction and Safety Information

Thank you for purchasing the DATOUBOSS Hybrid Solar Inverter. Please read this manual carefully before installing and using the inverter to ensure safe and optimal operation.

1.1. Safety Instructions

This chapter contains important safety instructions. Please read and save this manual for future reference.

  • Always comply with local requirements and regulations when installing this inverter.
  • Beware of high voltage. Before and during installation, turn off the switch of each power source to avoid electric shock.
  • Select appropriate cable sizes and necessary protection devices in accordance with regulations for optimal operation.
  • Do not connect or disconnect any connections while the inverter is working.
  • Do not open the terminal cover when the inverter is working.
  • Ensure the inverter is well grounded.
  • Do not short-circuit the AC output and DC input.
  • Do not disassemble the machine. For all repairs and maintenance, send it to a professional repair center.
  • Never charge a frozen battery.

WARNING:

This is a Class A inverter. It might cause slight radio interference in daily life. Practical measures are required to take under this condition.

2. Product Overview

The DATOUBOSS Hybrid Solar Inverter is a 3-in-1 device combining a solar inverter, charger, and MPPT controller. It is designed for off-grid energy storage systems.

2.1. Key Features

  • Output Power: 1800W
  • Input Voltage: 12VDC
  • Max PV Input Power: 2500W
  • Max PV Input Current: 15A
  • MPPT Tracking Range: 30-240VDC
  • Output Voltage: AC 220V/230V/240V, 50Hz/60Hz Pure Sine Wave
  • Protection Class: IP20
  • Multi-Protection Functions: Reverse connection, Short circuit, High temperature, Overload, Overcurrent, Over-discharge.

2.2. Dimensions and Interfaces

DATOUBOSS Hybrid Solar Inverter Dimensions and Key Features
Figure 2.1: Inverter Dimensions and Key Features

Dimensions:

  • Height: 31 cm (12.2 in)
  • Width: 25 cm (9.8 in)
  • Depth: 9.1 cm (3.58 in)
DATOUBOSS Hybrid Solar Inverter Detailed Interface Diagram
Figure 2.2: Detailed Inverter Interfaces

Interface Components:

  • Front: LCD display, LED display, Function key control area (DOWN, ESC, ENTER, UP).
  • Right Side: RS485-2 communication interface (BMS communication).
  • Left Side: Power on/off switch, RS485-1 communication interface (External communication/WIFI).
  • Bottom: Fan, Battery terminal port, PV input terminal port, Earth wire, AC output, AC input (on-grid) terminal.

3. Setup and Installation

3.1. Open-Package Inspection

After opening the package, check for random accessories (user manual, conformity certificate, warranty card) and any optional function accessories. Verify that the inverter is intact and free from damage. If any components are broken or missing, do not power on the machine and contact your distributor.

NOTE:

  • Keep the packing box and material for future transport.
  • This product is heavy; handle with care.

3.2. Installation Environment and Placement

  • Install in a well-ventilated area, free from water, burning gas, and corrosive substances.
  • The machine is wall-mounted. Ensure air inlet/outlet are unobstructed.
  • Ambient temperature should be 0-40°C.
  • If operating in low temperatures, condensation may occur. Ensure the machine is thoroughly dry before use.
  • If stored for a long time, confirm it is dry and free from corrosion before installation.
Inverter Placement Guidelines
Figure 3.1: Inverter Placement Guidelines

Leave at least 100mm of space on each side of the inverter for good air circulation. Install vertically on concrete or non-combustible surfaces with adequate load-bearing capacity. Avoid direct sunlight, dust, moisture, liquids, and overheating.

3.3. Electrical Connection Precautions

DANGER:

  • Always cover PV panels or disconnect DC circuit breaker before electrical connections.
  • Photovoltaic arrays generate dangerous voltages when exposed to sunlight.
  • Confirm correct polarity for battery connections.
  • All installation operations must be performed by professional electrical engineers.
  • Read this manual completely and understand all safety matters.

3.4. Wiring Instructions

Before connecting any wiring, remove the bottom cover by unscrewing it.

Hybrid Solar Inverter Wiring Diagram
Figure 3.2: Hybrid Solar Inverter System Wiring Diagram

3.4.1. Wire Diameter Selection

Use cables with suitable wire diameters, not lower than national safety standards. General wire diameter is selected based on a current density of not more than 5A/mm², minimizing connection wire length to reduce loss.

3.4.2. Battery Connection

  1. Remove 6mm insulation from positive and negative conductors.
  2. Check correct polarity from battery modules and inverter input connectors.
  3. Connect positive (+) to positive (+) of BATTERY input connector. Connect negative (-) to negative (-) of BATTERY input connector.
  4. Ensure correct polarity, firm connection, and no short circuits.

3.4.3. AC Input/Output Connection

CAUTION:

There are two terminal blocks: "INPUT" and "OUTPUT". Do NOT mis-connect them.

  1. Install a separate AC breaker between inverter and AC input power source.
  2. Remove 10mm insulation for four conductors.
  3. Insert AC Input wires according to polarities on terminal block and tighten screws. Connect PE protective conductor first.
  4. Insert AC output wires according to polarities on terminal block and tighten screws.

3.4.4. PV Connection

  1. Remove 10mm insulation from positive and negative conductors.
  2. Check correct polarity from PV modules and PV input connectors.
  3. Connect positive (+) to positive (+) of SOLAR input connector. Connect negative (-) to negative (-) of SOLAR input connector.
  4. Ensure correct polarity and firm connection.

3.4.5. Circuit Breaker Selection

  • Battery End: DC circuit breaker, working voltage greater than battery rated voltage.
  • PV Input End: DC circuit breaker, working voltage greater than PV array voltage.
  • AC Input End: AC circuit breaker, working voltage greater than mains supply rated voltage.
  • Rated Current: Approximately 1.5 times the maximum current when the inverter is working.

3.5. Final Assembly

After connecting all wirings, replace the bottom cover and secure it with screws.

4. Operating Instructions

4.1. Display Control Panel

Inverter Control Panel Layout
Figure 4.1: Control Panel Layout

The display board consists of three functional areas:

  1. LCD display area
  2. LED display area
  3. Function key control area

4.1.1. LED Indicators

NameDescription
AC (Green)On: Inverter works in main state. Flashing: AC input detection normal, works in battery priority mode. Off: Other states.
INV (Green)On: Inverter is working in inverter state. Off: Other states.
CHG (Yellow)On: Constant voltage charging, floating charging, or fully charged. Flashing: Constant current charging. Off: Other states.
FAULT (Red)On: Inverter self-protection. Flashing: Fault occurs in inverter. Off: Works normally.

4.1.2. Button Functions

Function KeyDescription
DOWNParameter less or previous page
ESCWithout saving or Exit setup mode
ENTERConfirm selection in setup mode or enter Save and exit setup mode
UPParameter more or next page

4.2. ON/OFF Button Description

4.2.1. Switch On

Connect to battery, AC power supply (confirm reasonable input range), or PV. Then press the ON button.

  • With Battery: Inverter establishes working power supply, then turns on with AC output.
  • With AC: Inverter establishes working power supply automatically, then turns on with AC output. If AC output priority mode is set, AC charges battery and bypasses output.
  • With PV: Inverter establishes working power supply automatically, charges battery, then turns on with AC output.

4.2.2. Switch Off

Press the OFF button.

  • With Battery: Inverter switches off output and working power after a period.
  • With AC: Inverter switches off output, maintains working power in standby, disconnects AC, and turns off.
  • With PV: Inverter switches off output, maintains working power, charges battery, disconnects PV, and turns off.

4.3. Function Setting Operation

To enter the function setting page, press ENTER for 2 seconds. Use UP/DOWN keys to select functions and values. Press ENTER to confirm settings. Press ENTER for 2 seconds again to exit and save, or ESC to exit without saving.

4.3.1. Output Priority Setting (A0)

Choices: GRD (Mains priority), PV (PV priority), PBG (Battery priority). Default is GRD. Only settable in battery mode.

4.3.2. Battery Type and Parameter Settings (A1-A7, A19-A23)

Set A17 to 'Pb' for lead-acid batteries or to 'GRD/VLO/PYL/PAC' for lithium batteries with BMS communication. Adjust parameters like average charge voltage (A1), float voltage (A2), low voltage protection (A3), low voltage alarm (A4, A5), mains to battery mode voltage (A6), and battery to mains voltage (A7).

4.3.3. Other Settings

  • Frequency Setting (A8): 50Hz or 60Hz.
  • Output Voltage Setting (A9): 220V, 230V, or 240V.
  • Charging Priority Setting (A10): SNU (PV & mains), OSO (Only PV), CSO (PV priority).
  • Non-Battery Mode Settings (A11): bC (connect battery) or bNC (disconnect battery).
  • Mains Charging Current (A12): 5A-65A.
  • Maximum Charging Current (A13): 5A-100A.
  • Mains Input Voltage Range (A14): UPS (165V-280V) or APL (120V-280V).
  • Working Mode Setting (A15): GRD (hybrid), GRE (grid-connected feed), DIS (off-grid).
  • Grid-Connected Current Setting (A16): 0A to max current (e.g., 8A for 1800W/220V).

4.4. Output Priority and Working Mode

The inverter continuously detects power grid fluctuations. If stable, it connects to mains; otherwise, it prevents frequent switching.

4.4.1. Grid-Tie Mode

  • Mains Power Priority: Mains and PV power load simultaneously. Battery powers load only when mains unavailable. PV charges battery, excess feeds grid.
  • PV Power Priority: PV power loads first, excess charges battery, then feeds grid.
  • Battery Priority (Off-Grid Operation): PV powers load first. If insufficient, batteries supplement. Switches to mains when battery discharge voltage reached.

4.4.2. Hybrid Mode

Similar priority options as Grid-Tie mode, managing power flow between PV, battery, mains, and load.

4.4.3. Off-Grid Mode

  • Mains Power Priority: Mains supplies load (bypass), PV charges battery. If mains unavailable, battery inverter works (PV + battery powers load).
  • Photovoltaic Priority: PV powers load first, excess charges battery. If insufficient, battery supplements. Switches to mains when battery discharge voltage reached.

4.4.4. No Battery Operation Mode

If no battery is configured, set A11 to 'bNC'. Output priority cannot be set to battery priority; inverter operates in grid-connected or hybrid mode.

5. Maintenance

The inverter requires minimal maintenance. Regular battery charging and dust filter cleaning are essential for longevity.

5.1. Battery Maintenance

  • Charge batteries every three months if the inverter is unused long-term.
  • Replace batteries if found in poor state; replacement should be done by professionals.
  • Discharge (until inverter shuts down) and recharge batteries every three months (or two months in high-temperature areas). Each charge should last at least 12 hours.

WARNING:

  • Battery must not be put in fire (explosion risk).
  • Do not open or damage the battery. Electrolyte can cause harm.

5.2. Dust Filter Assembly

Regularly clean the dust filter, especially in dusty environments, to prevent blockage and ensure proper airflow. This prevents overheating and extends the inverter's service life.

  1. Remove the two screws fixing the dust filter cover on the left and right sides.
  2. Take off the dust filter cover and dust filter.
  3. Clean the dust filter.
  4. Reinstall the dust filter and its cover in the reverse order.

6. Troubleshooting

When the inverter has a fault alarm, the red LED fault indicator flashes. If there is fault protection, the LED is on, and the LCD displays a fault code. Refer to the table below for descriptions and solutions.

Fault CodeFault MessageRecommended Action
40EEPROM Read and write faultContact the supplier.
41Communication failure with main controllerContact the supplier.
42Abnormal parameter settingCheck/restore factory settings.
43Abnormal reference voltageInternal power supply unstable; restart machine.
44BUS soft start faultCheck battery/input voltage (too low).
45Hardware over flowOutput overloaded or excessively large non-linear load.
46Short circuit faultCheck output for short circuit.
47Inverter faultInductive load impact; turn off/on inverter. If persists, contact supplier.
48, 49Battery over voltage alarm/protectionCheck battery voltage (too high), cell count, cell voltage.
50, 51Battery low voltage protection/alarmCheck battery voltage (too low), cell count, cell voltage.
52, 53BUS high/low voltage faultCheck battery or input voltage (too high/low).
54Overload alarmReduce output load.
55, 56, 57High temperature of inverter radiator/DC-DC/MPPT radiatorCheck cooling fan, ambient temperature, inverter vent blockage.
58, 59PV1/PV2 high voltageCheck PV input voltage exceeds operating range.
60Mains high voltageCheck input mains voltage (too high).
61Abnormal frequencyCheck mains frequency.
62Remote shutdownDetermine if remote shutdown command was sent.
63Abnormal communication with lithium batteryCheck inverter/battery protocol, connection line.
64, 65Lithium battery single cell or total voltage too high/lowCheck lithium battery cell/total voltage.
66Lithium battery discharge overcurrentLoad power too large.
67Lithium battery charge overcurrentReduce max charging current.
68Lithium battery temperature abnormalCheck if battery is overheated; shut down and wait for recovery.

7. Specifications

Detailed technical specifications for the DATOUBOSS DT-1218M Hybrid Solar Inverter.

DATOUBOSS DT-1218M Detailed Parameters
Figure 7.1: Detailed Product Parameters (Model DT-1218M)
ParameterSpecification
PV InputMax PV Input Power2500W
MPPT Tracking Voltage Range30VDC-240VDC
Rated Voltage180VDC
Max PV Input Voltage Voc (at lowest temp)300VDC
Max PV Input Current15A
MPPT Tracking Channels1
Battery & ChargingBattery TypeLead-acid Battery/Lithium Battery (Customizable)
Rated Battery Voltage12VDC
Battery Voltage Range10.5-15VDC (default)
Max PV Charging Current100A
Max AC Charging Current65A
Max Charging Current100A
Protection DegreeIP20
On-Grid Output (AC)Rated Output Power1800W
Rated Output Voltage220VAC/230VAC/240VAC
Grid Voltage Range187VAC-264VAC
Rated Output Frequency50Hz/60Hz
Frequency Range47Hz-52Hz(50Hz), 57Hz-62Hz(60Hz)
Rated Output Current8.1A/7.8A/7.5A
Power Factor>0.98 (Rated Power)
AC Input (Off-Grid)Rated Input Voltage220V/230V/240V
Mains Input Voltage Range165VAC-280VAC/120VAC-280VAC (Can be set)
Rated Input Frequency50Hz/60Hz
Input Frequency Range45Hz-55Hz(50Hz), 55Hz-65Hz(60Hz)
AC Output (Off-Grid)Rated Output Power1800W
Rated Output Voltage220V/230V/240V
Output Voltage Accuracy±2%
Rated Input Frequency50Hz/60Hz
Output Frequency Accuracy±1%
Output WavePure Sine Wave
Operating Temperature-10°C to 50°C
Storage Temperature-15°C to 60°C
Humidity0% to 95% (No condensation)
Noise≤55dB
InstallationWall-Mounted

8. User Tips

  • Understanding Port Directionality: The AC IN port is for connecting to the mains power grid, and the AC OUT port is for connecting to your household appliances. These ports are not bi-directional in terms of power flow for general operation; they have specific input and output roles as described in the wiring section.
  • Optimal Performance: Ensure proper ventilation around the inverter to prevent overheating, which can impact efficiency and lifespan.
  • Battery Compatibility: When using lithium batteries, ensure the BMS communication protocol is correctly configured in the inverter settings (A17) for proper battery management.

9. Warranty and Support

9.1. Warranty Information

The warranty period for this product is typically 1 year from the date of purchase. Please retain your warranty card as proof of maintenance. The warranty covers damages caused by product quality under normal use and maintenance. Free repair and replacement parts will be provided after verification.

9.1.1. Conditions that Void Warranty

  • Damage caused by manipulation not following manual instructions.
  • Product repaired or modified by unauthorized technicians, or internal parts replaced by users.
  • Product number altered or inconsistent with warranty card.
  • Damage due to careless use, water penetration, or other substances.
  • Damage caused by accident or natural disaster.

9.2. Further Support

For detailed instructions on RS485 communication ports, WIFI communication port setup (if WIFI module is installed), and other advanced topics, please refer to the complete PDF user manual available at this link.